Search NASASearch

SEARCH · Search NASA

Results for “High-resolution electron microscopy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

851 records · Page 4

Polarized target nuclear magnetic resonance measurements with deep neural networks

Continuous-wave Nuclear Magnetic Resonance (CW-NMR) operated in constant-current mode has served as a foundational technique for polarization measurement in solid-state dynamically polarized targets within nuclear and high-energy physics experiments for several decades, and it remains an essential tool. Conventional Q-meter-based phase-sensitive detection is critical for precise real-time determination of target polarization during scattering runs. However, the accuracy and reliability of these measurements are frequently compromised by elevated noise levels, baseline drift, and systematic uncertainties arising from signal isolation and fitting, ultimately degrading the overall experimental figure of merit. In this work, we report the first successful application of neural network architectures to continuous-wave NMR polarization metrology. By leveraging advanced machine learning techniques for signal extraction and denoising, we achieve a substantial reduction of fitting uncertainties under a variety of realistic simulated and experimental conditions. These improvements translate directly into more robust real-time (online) polarization monitoring and higher precision in subsequent offline analysis. By reducing analysis-induced uncertainty, the resulting methodology can improve the effective figure of merit for scattering experiments employing dynamically polarized targets and provides a new toolset for NMR-based polarimetry in high-energy and nuclear physics.

Metrology

Superconducting Material Growth for Radio-Frequency (RF) Cavities

Superconducting radio-frequency (SRF) cavities, usually manufactured from Niobium (Nb), are vital components of modern particle accelerators because of their ability to achieve high acceleration gradients with little power dissipation. Naturally forming Nb surface oxides significantly alter cavity performance by changing surface resistance. A nondestructive characterization of oxide thickness is helpful for relating surface processing treatments to cavity performance. This work develops a protocol to measure Nb oxide thickness using Angle-Resolved X-ray Photoelectron Spectroscopy (ARXPS) while correcting instrumental errors. Using uniform bulk standard samples (Silver, Aluminum oxide, and Germanium), we determined a baseline correction factor to account for analyzer-related intensity evolution as the measurement angle increases. The correction factor was then applied to Nb 3d ARXPS data. Applying the Strohmeier equation to the corrected data yielded a Nb2O5 thickness of 6.04 nm, closely matching the 5.5 (±.05) nm value obtained from cross-sectional transmission electron microscopy. Our approach will bring a method to incorporate inherent errors in the thickness measurements using ARXPS and can be broadly applied to improve the accuracy of thickness measurements in a wide range of heterostructures.

Lambert, Nathan [Fermilab]

Automated scanning probe microscopy of combinatorial ferroelectric libraries: Gaussian-process-guided exploration and noise-aware experiment planning

Combinatorial materials libraries provide an efficient route for mapping composition–property relationships, but their broader impact depends on rapid, quantitative, and functionally relevant characterization. Scanning Probe Microscopy (SPM), including piezoresponse force microscopy (PFM), offers significant potential for quantitative, functionally relevant combi-library readouts. Here, we implement a fully automated SPM workflow for ferroelectric combinatorial libraries and benchmark Gaussian-process-based Bayesian optimization strategies for autonomous experiment planning. The workflow integrates automated probe motion, contact optimization, imaging, and dual amplitude resonance tracking-PFM spectroscopy, and uses scalarized spectroscopic observables to guide subsequent measurements. Stage motion, probe engagement, in-contact tuning, imaging, spectroscopy, and the choice of the next measurement location all proceed without human input. We demonstrate the approach on Sm-doped BiFeO 3 and Zn x Mg 1−x O libraries. By comparing vanilla Bayesian optimization with a measured-noise variant, we show that explicit treatment of local reproducibility can improve modeling of composition-dependent response when the measured variance is physically meaningful, but can also reduce robustness when variability is dominated by outliers or topographic artifacts. Furthermore, these results establish automated SPM as a bridge between combinatorial synthesis and quantitative functional characterization.

Liu, Yu [University of Tennessee, Knoxville, TN (U

Comparing Thermal Neutron Scintillators for Use With SiPM-Readout Detectors

Scintillator-based thermal neutron detectors for scientific scattering facilities offer an effective combination of large-area coverage and good spatial resolution. At Oak Ridge National Laboratory, silicon photomultiplier (SiPM)-readout Anger cameras using 6 Li glass scintillators have been developed, but the spatial resolution of these detectors is limited by the relatively low light yield of the glass. Recently, several brighter scintillator compositions with sufficient 6 Li concentration have emerged as promising candidates for higher-resolution imaging. Here, in this work, we evaluate five scintillator materials: GS20, LiF/ZnS:Ag, LiF/ZnO:Zn, LiI:Eu, and Cs 2 LiYCl 6 :Ce, each mounted on a SiPM Anger camera. For each scintillator, the neutron detection efficiency, spatial resolution, and count rate capabilities were measured and compared. Each of the new compositions achieved a spatial resolution better than 0.5 mm, compared to 0.66 mm for GS20, with LiI:Eu reaching the best value of 0.32 mm. Although these compositions improve the spatial resolution of the Anger camera, their longer pulse decay times limit their use in high count rate applications, and the camera’s hardware must be optimized for the different properties of the new scintillators.

Neutron detectors

Multi-Resolution UAV Path Replanning for Inspection of Tailings Dams

Autonomous inspection of large and complex structures with a commercial unmanned aerial vehicle (UAV) is a challenging problem that has been addressed in recent years. In this paper, we address the global motion planning problem of creating autonomous inspection missions for UAVs considering photogrammetry constraints. We focus on the inspection of large tailings dams, which are dam structures used to store waste byproducts of mining. Our method uses a prior sparse point cloud of the dam to generate a voxel grid, where paths satisfying photogrammetry constraints are tested for collisions. We then apply the A* algorithm as a local planner to avoid obstacles within the global mission. Moreover, we address the problem of changing routes online by using octree-based multi-resolution grids for efficient and fast pathfinding. Our results, obtained using tridimensional maps of an actual coal mine tailings dam, show that using octrees for multi-resolution motion planning is faster than using a fixed voxel grid in online missions while inspecting large structures.

42 ENGINEERING

3D Printing of Polyelectrolyte Complex-Integrated Photocurable Hydrogel Resins

In this study, we developed a photocurable hydrogel resin incorporating a polyelectrolyte complex (PEC) for 3D printing. Acrylamide-based monomers were formulated with varying PEC contents (0–15 wt %) in an aqueous KBr medium to fabricate patterned porous hydrogel structures. The morphology of printed hydrogels was characterized by field-emission scanning electron microscopy and energy-dispersive X-ray spectroscopy. Notably, the PEC5 and PEC10 formulations exhibited optimal thermal stability and compressive properties, attributed to the homogeneous distribution of PEC domains within the hydrogel matrix. Furthermore, dye adsorption experiments demonstrated excellent removal efficiency, highlighting the potential of PEC-containing hydrogels for environmental remediation applications, particularly in the treatment of dye-contaminated wastewater.

Yang, Jinchul [University of Tennesse Knoxville]

Analysis of an irradiated uranium sample for source attribution without chemical separation using microplasma ionization and ultrahigh resolution mass spectrometry

The use of element isotope ratios has great potential in not only determining the reactor type used to produce plutonium (Pu) but also in determining the burnup and the time since irradiation. While a powerful nuclear forensic technique, determining element isotope ratios is complicated by severe isobaric interferences when performed on typical inductively coupled plasma mass spectrometers. Such analyses require extensive chemical separations prior to analysis to alleviate the inter-elemental isobars. Ultrahigh mass resolution spectrometry provides a potential alternative, greatly reducing the complexity of sample preparation and turnaround times for these critical measurements. To demonstrate the power of the approach, a sample of irradiated, depleted uranium was analyzed with the liquid sampling—atmospheric pressure glow discharge ion source coupled to an Orbitrap mass spectrometer. The Orbitrap is augmented with an external data acquisition system, Spectroswiss’s FTMS-Booster X2T, allowing collection of extended ion transients, providing higher mass resolution. In using this approach, the 150 Sm/ 149 Sm and 152 Sm/ 149 Sm isotope ratios were found to be within 20% of predicted values without any chemical separations and without mass bias corrections. In addition, the 240 Pu/ 239 Pu isotope ratio was determined, free from the 238 UH + interferences common to the ICP-MS platforms, while at the same time allowing for the determination of U isotopic signatures. While these demonstrative results are from a single sample, the advantages of the microplasma/ultrahigh mass resolution approach to intra-element isotope ratio determinations are clear.

Fuel burnup

Dynamic sparse x-ray nanotomography reveals ionomer hydration mechanism in polymer electrolyte fuel-cell catalyst

Tomographic imaging of time-evolving samples is a challenging yet important task for various research fields. At the nanoscale, current approaches face limitations of measurement speed or resolution due to lengthy acquisitions. We developed a dynamic nanotomography technique based on sparse dynamic imaging and 4D tomography modeling. We demonstrated the technique, using ptychographic x-ray computed tomography as its imaging modality, on resolving the in situ hydration process of polymer electrolyte fuel cell (PEFC) catalyst. The technique provides a 40-time increase in temporal resolution compared to conventional approaches, yielding 28 nm half-period spatial and 12 min temporal resolution. The results allow a quantitative characterization of the water intake process inside PEFC catalysts with nanoscale resolution, which is crucial for understanding their electrochemical mechanisms and optimizing their performance. Our technique enables high-speed operando nanotomography studies and paves the way for wider application of dynamic tomography at the nanoscale.

Science & Technology - Other Topics

Strain and Defect-Tailored Magnetotransport in NiCo 2 O 4 Thin Films and Freestanding Membranes

Magnetic spinel NiCo 2 O 4 is promising for developing spintronic applications due to its high magnetic Curie temperature, high spin polarization, fast spin dynamics, and strain-tunable magnetic anisotropy, while its electronic and magnetic properties depend sensitively on epitaxial strain and disorder. Here, in this study, we use epitaxial NiCo 2 O 4 thin films and freestanding NiCo 2 O 4 membranes as model systems to reveal the complex interplay of strain and defects in determining the metallicity and magnetotransport properties of the ferrimagnetic spinel. NiCo 2 O 4 on perovskite substrates and NiCo 2 O 4 membranes exhibit insulating behaviors and spin canting, in sharp contrast to the metallic NiCo 2 O 4 films on spinel substrates that possess strong perpendicular magnetic anisotropy. Anisotropic magnetoresistance studies provide critical information about disorder-induced spin scattering and strain-induced tetragonal magnetocrystalline anisotropy, which is corroborated by comprehensive electron microscopy characterizations. Our study presents a promising venue for designing flexible magnetic memory, sensor, and spintronic applications.

36 MATERIALS SCIENCE

Super-resolution imaging reveals resistance to mass transfer in functionalized stationary phases

Chemical separations are costly in terms of energy, time, and money. Separation methods are optimized with inefficient trial-and-error approaches that lack insight into the molecular dynamics that lead to the success or failure of a separation and, hence, ways to improve the process. We perform super-resolution imaging of fluorescent analytes in five different commercial liquid chromatography materials. Unexpectedly, we observe that chemical functionalization can block more than 50% of the material’s porous interior, rendering it inaccessible to small-molecule analytes. Only in situ imaging unveils the inaccessibility when compared to the industry-accepted ex situ characterization methods. Selectively removing some of the functionalization with solvent restores pore access without substantially altering the single-molecule kinetics that underlie the separation and agree with bulk chromatography measurements. Our molecular results determine that commercial “fully porous” stationary phases are over-functionalized and provide an alternative avenue to characterize and direct separation material design from the bottom-up.

Science & Technology - Other Topics

Eliminating chemo-mechanical degradation of lithium solid-state battery cathodes during >4.5 V cycling using amorphous Nb2O5 coatings

Abstract Lithium solid-state batteries offer improved safety and energy density. However, the limited stability of solid electrolytes (SEs), as well as irreversible structural and chemical changes in the cathode active material, can result in inferior electrochemical performance, particularly during high-voltage cycling (>4.3 V vs Li/Li + ). Therefore, new materials and strategies are needed to stabilize the cathode/SE interface and preserve the cathode material structure during high-voltage cycling. Here, we introduce a thin (~5 nm) conformal coating of amorphous Nb 2 O 5 on single-crystal LiNi 0.5 Mn 0.3 Co 0.2 O 2 cathode particles using rotary-bed atomic layer deposition (ALD). Full cells with Li 4 Ti 5 O 12 anodes and Nb 2 O 5 -coated cathodes demonstrate a higher initial Coulombic efficiency of 91.6% ± 0.5% compared to 82.2% ± 0.3% for the uncoated samples, along with improved rate capability (10x higher accessible capacity at 2C rate) and remarkable capacity retention during extended cycling (99.4% after 500 cycles at 4.7 V vs Li/Li + ). These improvements are associated with reduced cell polarization and interfacial impedance for the coated samples. Post-cycling electron microscopy analysis reveals that the Nb 2 O 5 coating remains intact and prevents the formation of spinel and rock-salt phases, which eliminates intra-particle cracking of the single-crystal cathode material. These findings demonstrate a potential pathway towards stable and high-performance solid-state batteries during high-voltage operation.

Science & Technology - Other Topics

Qualifying LaBr3:Ce+Sr detector performance for the Mu2e experiment at Fermilab Using the ELBE Accelerator

A LaBr3:Ce+Sr detector will be used to measure the stopped muon captures at the Mu2e experiment at Fermilab. It has been benchmarked in a test beam experiment performed at the ELBE electron accelerator located at the Helmholtz-Zentrum Dresden-Rossendorf, Germany. ELBE’s pulsed bremsstrahlung beam line was set to deliver an average γ -ray energy of between 4–5 MeV. The detector response was mapped to match Mu2e beam conditions, including rates up to 1 Mcps, energy flux, and time structure. A radioactive calibration source was used to mimic the characteristic 1808.7 keV γ -ray, emitted during the atomic muon nuclear capture in the Mu2e aluminum stopping target. The detector energy resolution was measured as a function of the average energy flux: up to 1 TeV/s for 0.34 s, the steady-operation beam-on time and up to 4 TeV/s for 5 ms to get a conservative estimate of the effect of high intensity Mu2e beam fluctuations. The PMT gain variation as a function of the beam spill length and average intensity has been parametrized and corrected for. When a PMT gain correction corresponding to the average beam-spill intensity is applied, the residual effect of beam intensity fluctuations around the average degrades the energy resolution, σ E γ /E γ , at 1808.7 keV from 0.66% to 0.83%.

Huang, Shihua [Purdue U., West Lafayette]

In‐Plane Anisotropy in van der Waals NiTeSe Ternary Alloy

Abstract The anisotropic properties of materials profoundly influence their electronic, magnetic, optical, and mechanical behaviors and are critical for a wide range of applications. In this study, the anisotropic characteristics of Ni‐based van der Waals materials, specifically NiTe 2 and its alloy NiTeSe, utilizing a combination of comprehensive scanning tunneling microscopy (STM), angle‐resolved photoemission spectroscopy (ARPES), and density functional theory (DFT) calculations, are explored. Unlike 1T‐NiTe 2 , which exhibits trigonal in‐plane symmetry, the substitution of Te with Se in NiTe 2 (resulting in the NiTeSe alloy) induces a pronounced in‐plane anisotropy. This anisotropy is clear in the STM topographs, which reveal a distinct linear order of charge distribution. Corroborating these observations, ARPES measurements and DFT calculations reveal an anisotropic Fermi surface centered at the point, which is notably elongated along the k y direction, leading to directional variations in in‐plane carrier velocities. Consequently, the Fermi velocity is highest along the k x direction where the linear charge distribution aligns in real space and is lowest along the k y direction. These findings offer valuable insights into the tunability of anisotropic properties in ternary transition metal dichalcogenide systems, highlighting their potential applications in the development of anisotropic electronic and optoelectronic devices.

Chemistry

Revealing Hidden Quinones Through Diagnostic MS² Fragmentation of Peptide–Quinone Adducts

Quinones are redox-active components of natural organic matter that mediate electron transfer and influence biogeochemical processes, but many quinones in pyrogenic organic matter (PyOM) remain unresolved because they ionize poorly by mass spectrometry. Here, we present a peptide-tagging approach to improve detection of cysteine-reactive electrophiles in PyOM, with quinones expected to be a dominant subset based on reaction chemistry and selectivity experiments. A cysteine-containing peptide was used to form Michael-addition adducts, enhancing electrospray ionization and enabling untargeted screening by high-performance liquid chromatography-high-resolution tandem mass spectrometry. The method was benchmarked with five quinone standards and applied to extracts from charred plant material as a discovery-level screen for cysteine-reactive targets. We identified 98 quinone-candidate adducts (mean neutral mass ~603 Da), of which more than 70% were not detectable in native MS1 data. Among formula-assigned features, hidden quinone candidates had median (O+N)/C of 0.391 and normalized oxidation state of carbon of -0.281, consistent with relatively low polarity and low oxidation state. These results reveal a previously inaccessible pool of hidden redox-active compounds in PyOM and provide a framework for prioritizing quinone-like electrophiles for confirmation and incorporation into models of fire-driven biogeochemical cycling.

LC-MS/MS

Passive Confirmation of the Presence Of High-Explosive Material Via Neutron Transmission Spectroscopy

The goal of this project was to explore a novel approach for identifying presence and potential types of high explosives (HE) in treaty-controlled items with passive neutron sources by using passive neutron transmission spectroscopy. We predominantly look to measure relative elemental abundance of Carbon, Hydrogen, Oxygen, and Nitrogen (CHON) since most relevant materials are certain mix of these elements, as shown in Table 1. Previously, most studies exploring potential identification of CHON elemental content of targets in the vicinity of passive neutron source were focused solely on gamma spectroscopy using high resolution gamma detectors. Using neutron transmission spectroscopy with pulse-shape discrimination (PSD) capable organic scintillators is not only a novel idea in of itself, but arguably necessary for accurate identification of the CHON elemental content of an interrogated target. While high resolution gamma spectroscopy in principle can determine a presence of hydrogen and nitrogen, it is effectively blind to a quantitatively measuring areal densities of C, O. The initially proposed approach, described in detail in the project proposal, was to leverage previous Monte Carlo study on neutron transmission spectroscopy using slab shaped target interrogated with well-collimated (“pencil”) neutron beam. In this study, a simulated test CO 2 target was interrogated by a pencil neutron beam and transmitted neutron spectra were measured using PSD capable organic scintillator using MLEM based unfolding technique. To establish relative elemental content of carbon and oxygen, the unfolded neutron spectrum was fit with a parametrized combination of their respective elemental spectral templates. The individual spectral template was calculated by convoluting ENDF neutron crosssection with the known resolution of the PSD detector used in the study. This approach in the studied configuration successfully quantitatively established relative elemental composition of carbon and oxygen.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND