Long-Term field testing of the accuracy and HVAC energy savings potential of occupancy presence sensors in A Single-Family home

The energy-saving potential of occupancy-centric smart thermostats has been extensively explored in simulations but lacked field testing for energy savings quantification and sensor performance assessment in real buildings. This paper presents a long-term field study conducted in a single-family home in Texas, U.S. to evaluate the performance of occupancy-centric controls (OCC) of HVAC (heating, ventilation, and air-conditioning) system in terms of energy savings, sensor accuracy, and impact on electric peak demand. The test site was equipped with a commercial off-the-shelf (COTS) smart thermostat and multiple occupancy presence sensors for OCC implementation. Additionally, a sub-metering system was installed to monitor electricity consumption of various end-use equipment, including the HVAC system. A supplementary device was installed to track the ground-truth occupancy for the accuracy evaluation of the occupancy presence sensor. Scenarios of baseline and OCC controls were alternated weekly over the 20-month testing period. The results indicated an effective OCC execution, as evidenced by indoor temperature profiles. During the 2023 cooling season, OCC achieved total energy savings of 1,958 kWh, corresponding to a 17.6% energy savings ratio. Under certain conditions, daily HVAC energy savings reached as high as 17 kWh, with a savings ratio of 35%. Sensor performance showed an overall accuracy of 83.8%, a False Positive Rate (FPR) of 12.8%, and a False Negative Rate (FNR) of 47.4%. A key limitation was the sensor’s inability to detect stationary occupants during sleep, leading to a midnight FNR of nearly 100% and significantly compromising thermal comfort. Additionally, the implementation of OCC resulted in extended periods of high electricity demand on summer afternoons, affecting occupant’s thermal comfort and posing potential challenges to community-level grid operations if OCC were widely adopted. Furthermore, this study addresses a critical research gap by empirically investigating energy-saving potential and occupancy sensor performance in residential buildings. Through a comprehensive field-testing study, the research examines the interrelationship between sensor accuracy, energy savings, and thermal comfort, an area that has received limited attention in the current literature.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Potential impact of work from home jobs on residential energy bills: A case study in phoenix, AZ, USA

Nearly one-third of U.S. households face challenges paying energy bills. During the day, many residents have routine access to cooled environments provided by others—employers, shopping centers, and other public buildings. The COVID-19 pandemic, however, has significantly shifted the cost burden of air conditioning in hot cities. Specifically, during the pandemic, many companies either laid off employees or put them in work-from-home (WFH) assignments. Large tech companies are already promoting WFH as a long-term option for their employees, even after the pandemic. This change in the nature of the workforce might reduce daily travel expenses for workers, but could also significantly increase residential energy bills, particularly during summer in very hot climates. Here, this study uses building energy simulations to quantify the potential residential energy bill penalties resulting from WFH for typical residences in Phoenix. Four building archetypes are used in this study to represent variations in building vintage, occupancy, and characteristics. The results show that, for some single-family residences in Phoenix, WFH can increase annual energy bills by more than $1100 (up to a 70% increase). The study also demonstrates that building performance enhancement retrofit measures have the potential to reduce this WFH energy bill penalty for the existing buildings substantially.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Multiple emission components in the Cygnus cocoon detected from Fermi -LAT observations

Star-forming regions may play an important role in the life cycle of Galactic cosmic rays (CRs), notably as home to specific acceleration mechanisms and transport conditions. Gamma-ray observations of Cygnus X have revealed the presence of an excess of hard-spectrum gamma-ray emission, possibly related to a cocoon of freshly accelerated particles. We seek an improved description of the gamma-ray emission from the cocoon using ~13 yr of observations with the Fermi-Large Area Telescope (LAT) and use it to further constrain the processes and objects responsible for the young CR population. We developed an emission model for a large region of interest, including a description of interstellar emission from the background population of CRs and recent models for other gamma-ray sources in the field. Thus, we performed an improved spectro-morphological characterisation of the residual emission including the cocoon. The best-fit model for the cocoon includes two main emission components: an extended component FCES G78.74+1.56, described by a 2D Gaussian of extension r 68 = 4.4° ± 0.1° -0.1° +0.1° and a smooth broken power law spectrum with spectral indices 1.67 ± 0.05 -0.01 +0.02 and 2.12 ± 0.02 -0.01 +0.00 below and above 3.0 ± 0.6 -0.2 +0.0 GeV, respectively; and a central component FCES G80.00+0.50, traced by the distribution of ionised gas within the borders of the photo-dissociation regions and with a power law spectrum of index 2.19 ± 0.03 -0.01 +0.00 that is significantly different from the spectrum of FCES G78.74+1.56. An additional extended emission component FCES G78.83+3.57, located on the edge of the central cavities in Cygnus X and with a spectrum compatible with that of FCES G80.00+0.50, is likely related to the cocoon. For the two brightest components FCES G80.00+0.50 and FCES G78.74+1.56, spectra and radial-azimuthal profiles of the emission can be accounted for in a diffusion-loss framework involving one single population of non-thermal particles with a flat injection spectrum. Particles span the full extent of FCES G78.74+1.56 as a result of diffusion from a central source, and give rise to source FCES G80.00+0.50 by interacting with ionised gas in the innermost region. For this simple diffusion-loss model, viable setups can be very different in terms of energetics, transport conditions, and timescales involved, and both hadronic and leptonic scenarios are possible. The solutions range from long-lasting particle acceleration, possibly in prominent star clusters such as Cyg OB2 and NGC 6910, to a more recent and short-lived release of particles within the last 10–100 kyr, likely from a supernova remnant. The observables extracted from our analysis can be used to perform detailed comparisons with advanced models of particle acceleration and transport in star-forming regions.

79 ASTRONOMY AND ASTROPHYSICS↗

Computational and Experimental Investigation of Thermal-Mechanical- Chemical Mechanisms of High-burnup Spent Nuclear Fuel (SNF) Processes at Elevated Temperatures and Degradation Behavior in Geologic Repositories

The overarching goal of the combined computational and experimental R&D activities proposed in this project is to enhance understanding of the mechanisms and thermal-mechanical-chemical (TMC) parameters controlling the instant release fraction (IRF) and matrix dissolution of high-burnup (HB; burnup) spent nuclear fuels (SNFs) and the subsequent formation, stability, and phase transformations of SNF alteration products under long-term storage and geological disposal conditions. Uranium dioxide may undergo oxidative corrosion/alteration, and the IRF may be increased for HB SNF, both of which may affect environmental systems associated with SNF long-term storage and disposal. The oxidative matrix dissolution may form various complex uranyl-based phases, including a rich variety of oxides, silicates, carbonates and other secondary minerals in varied geological environments (e.g., studtite, metastudtite, amorphous uranyl peroxide, uranium trioxide, triuranium octoxide, schoepite, dehydrated schoepite, metaschoepite, becquerelite, soddyite, rutherfordine,...). These uranyl phases generally have higher mobility UO 2 +2 species than less soluble U 4+ phases. However, limited information on the thermodynamic properties and formation kinetics of these uranyl-bearing phases is available to predict explicitly paragenesis under the conditions relevant to long-term storage or disposal. The proposed project draws on complementary expertise and research backgrounds from the team members: (i) to apply a combined ab initio modeling (UNLV/UTEP and SNL) and experimental (UNLV) strategy investigating the high-temperature TMC mechanisms of alteration of SNF under α-radiolysis conditions; (ii) to investigate the mechanistic of phase transformations in UNF degradation products under various conditions expected in long-term storage systems (e.g. (UO 2 )O 2 (H 2 O) 4 → (UO 2 )O 2 (H 2 O) 2 → U 2 O 7 → UO 3 → U 3 O 8 ); (iii) to determine high-accuracy TMC parameters for complex uranyl-based phases formed in storage or geological disposal environments (e.g. UO 3 (H 2 O) 2 , Ca[(UO 2 ) 6 O 4 (OH) 8 ] 8 H 2 O, (UO 2 ) 2 (SiO 4 ) 3 2H 2 O,…). The unforeseen COVID-19 pandemic led to the laboratory/campus closure since March 2020, that resulted in a significant delay in reaching milestones in a satisfactory manner, due to (i) the statewide recommendation from stop-working to later limited work in the lab and work-from-home (WFH), (ii) no in-person interactions, and (iii) a hiring freeze at UNLV. Therefore, a no cost extension (10/01/2021- 9/30/2022) was requested to help make up the time we lost during the global pandemic in 2020-2021, leading to paradigm shifts in the focus of the project in the following three main tasks: Task 1 (Computational), Task 2 (Experimental), and Task 3 (Final report, due on 12/29/2022).

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

FRMAC Laboratory Analysis Manual Volume 1, Revision 0

The Federal Radiological Monitoring and Assessment Center (FRMAC) is an operational center, available on request by the Department of Homeland Security (DHS) to respond to nuclear and radiological incidents as described in the National Response Framework (NRF). Under the Federal Interagency Operational Plan for Response and Recovery’s Nuclear/Radiological Annex, the U.S. Department of Energy (DOE) has the responsibility to maintain the operational readiness of the FRMAC during the emergency phase of an event. FRMAC is initially established and managed by the Nuclear Emergency Support Team (NEST) and serves as an interagency operations center with representatives from various federal, state, and local radiological response organizations. The purpose of the FRMAC is to assist state, local, tribal, and territorial governments (SLTT) in their mission to protect the health and well-being of their citizens with: • Verified radiation measurements. • Interpretations of radiation distributions based on Environmental Protection Agency (EPA), Food and Drug Administration (FDA), or local Protective Action Guidelines (PAGs). • Characterization of overall radiological conditions. Once a declaration to respond to a radiological emergency has been made, the National Nuclear Security Administration (NNSA) Headquarters will coordinate the response in consultation with the cognizant NNSA Regional Coordinating Office (RCO). Each of the eight RCOs maintain a 24-hour response capability for radiological emergencies that may occur in states served by its region. When a FRMAC is established, it operates under the parameters of the Incident Command System (ICS), as defined in the National Incident Management Systems (NIMS) construct. The Consequence Management Home Team (CMHT) will be activated immediately during normal business hours (Pacific Time Zone), and within two hours otherwise. The Consequence Management Response Team (CMRT) is prepared for deployment within six hours after activation. Along with the assets, FRMAC provides an operational framework for coordinating of all federal off-site radiological monitoring and assessment activities during a response to a radiological emergency to support the coordinating agency and SLTT governments. Potential radiological emergencies that fall within FRMAC vary widely in terms of the area affected, the nature of the contamination, and the scope of the government’s response. Detonation of a nuclear device, accidental release of radiation from a nuclear power plant, and a terrorist threat are just a few of the many possible scenarios FRMAC must be prepared to address. Through all this, supporting the state, local, and tribal organizations in the protection of the public remains the primary goal of the federal response.

54 ENVIRONMENTAL SCIENCES↗

Reducing Exposures to Airborne Particles Through Improved Filtration: A High-Level Modeling Analysis

Indoor airborne particulates are well-known health hazards and filtration is one common method of reducing exposures. Based on our previously developed Regional Shelter Analysis methodology and parameters that characterize the existing US building stock, we perform a high-level assessment of the potential benefits of upgrading existing filters in furnace and in heating, ventilation, and air conditioning systems using off-the-shelf filters. We use three metrics to assess the improvement: Building Transmission Factor (a measure of protection against outdoor airborne particles), Indoor Normalized Time and Space Integrated Air Concentration (a measure of indoor exposure to indoor-origin airborne particles), and Building Exit Fraction (fraction of indoor airborne particles that are released to the outdoor atmosphere). We also discuss the potential reduction in regional exposures due to particles exiting the building and exposing downwind building occupants. Our modeling indicates that while buildings provide their occupants passive protection against airborne particulate hazards, including but not limited to PM 2.5 , PM 10 , and wildfire smoke; improving particle filtration efficiency may further improve this protection. The degree of improvement varies with particle size and building type. Of the building types studied, apartments are predicted to benefit most, with greater than a factor of 2 improvement (≥50% reduction in exposures) for 1 µm particle exposures when using MERV 7 to 12 rated filters. Non-residential buildings were notably less responsive to improved filtration but had the highest Building Exit Fractions with 30% to 40% of indoor airborne particles released to the outdoor atmosphere (apartment buildings only released 6% to 9%). Improvements predicted for single family homes were intermediate between apartments and non-residential buildings. Improvements in the Regional Exposure metric are larger, ranging from a factor of 2.5x to 10x for residences (when using MERV 7 to 12 rated filters) and up to 25x for large apartments with MERV 14 or 15 rated filters. The results of our modeling analysis are broadly consistent with the limited experimental data and modeling results available in the literature.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Radial Clearance Found To Play a Key Role in the Performance of Compliant Foil Air Bearings

Compliant foil air bearings are at the forefront of the Oil-Free turbomachinery revolution, which supports gas turbine engines with hydrodynamic bearings that use air instead of oil as the working fluid. These types of bearings have been around for almost 50 years and have found a home in several commercial applications, such as in air cycle machines, turbocompressors, and microturbines, but are now being aggressively pursued for use in small and midrange aircraft gas turbine engines. Benefits include higher operating speeds and temperatures, lower maintenance costs, and greater reliability. The Oil-Free Turbomachinery team at the NASA Glenn Research Center is working to foster the transition of Oil-Free technology into gas turbine engines by performing in-house experiments on foil air bearings in order to gain a greater insight into their complex operating principles. A research program recently undertaken at Glenn focused on the concept of radial clearance and its influence on bearing performance. The tests were conducted on foil bearings with different radial clearances. As defined for a foil bearing, radial clearance is a measure of the small amount of shaft radial motion that is present from play that exists in the elastic support structure, such as between the top and bump foils and the bump foils and bearing shell (see the drawing). With an insufficient amount of radial clearance, the bearing imparts a high preload on the shaft, which when excessive, can reduce the loadcarrying capability of the bearing. On the other hand, systems using foil bearings with excessive radial clearance may experience rotordynamic instabilities because of low bearing preload. Therefore, without a more thorough understanding of radial clearance, it is difficult to accurately predict the performance of a given bearing design. The test program demonstrated that there is a direct correlation between radial clearance and the performance of foil air bearings. As shown in the graph, an optimum radial clearance exists that will maximize the amount of load that the bearing is capable of supporting. With respect to this optimum, two different performance regimes were observed that are a function of the amount of radial clearance. Tests showed that bearings with radial clearances below the optimum in regime I were susceptible to sudden seizure, a failure mode indicative of thermal runaway caused by high preload. The high preload is in response to an insufficient amount of radial clearance available to accommodate the thermal growth of the bearing and shaft. However, radial clearances greater than the optimum in regime II resulted in low bearing preloads that did not cause any heat-related problems, and the failure mode was due to fluid-film breakdown. In fact, bearings operating with radial clearances twice as much as the optimum suffered a decrease in the maximum load capacity of only about 20 percent. Therefore, special attention has to be given to the range of operating conditions expected in the bearing/shaft system since changes in temperature, centrifugal, and hydrodynamic effects can all affect radial clearance. This enhanced understanding of foil air bearing behavior will greatly aid our efforts to transition Oil-Free technology to future aircraft engines.

Radil, Kevin C.↗