Search NASA⌕ Search

SEARCH · Search NASA

Results for “Home thermal model”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

A Robust Hierarchical Dispatch Scheme for Active Distribution Networks Considering Home Thermal Flexibility

Distribution networks are changing from passive absorbers of electric energy to active distribution networks (ADNs) capable of operating and participating in electricity markets. In the context of residential microgrids, which is a type of ADNs, aggregated home heating, ventilation and air-conditioning (HVAC) loads present a key opportunity to drive operational and economic objectives, facilitate high renewable energy penetration, and enhance both system resiliency and flexibility. A robust, hierarchical dispatch scheme is developed and presented in this paper, which connects an upper level multi-phase distribution optimal power flow (DOPF) to a lower level model predictive control (MPC)-based HVAC fleet controller. The approach is tested and verified on a modified IEEE 13 bus system in an intraday market application. The results demonstrate that the proposed hierarchical dispatch scheme is able to drive both economic and operational objectives for the ADN operator.

Rooks, Cody D.↗

Co-Simulation of Electric Power Distribution Systems and Buildings including Ultra-Fast HVAC Models and Optimal DER Control

Smart homes and virtual power plant (VPP) controls are growing fields of research with potential for improved electric power grid operation. A novel testbed for the co-simulation of electric power distribution systems and distributed energy resources (DERs) is employed to evaluate VPP scenarios and propose an optimization procedure. DERs of specific interest include behind-the-meter (BTM) solar photovoltaic (PV) systems as well as heating, ventilation, and air-conditioning (HVAC) systems. The simulation of HVAC systems is enabled by a machine learning procedure that produces ultra-fast models for electric power and indoor temperature of associated buildings that are up to 133 times faster than typical white-box implementations. Hundreds of these models, each with different properties, are randomly populated into a modified IEEE 123-bus test system to represent a typical U.S. community. Advanced VPP controls are developed based on the Consumer Technology Association (CTA) 2045 standard to leverage HVAC systems as generalized energy storage (GES) such that BTM solar PV is better utilized locally and occurrences of distribution system power peaks are reduced, while also maintaining occupant thermal comfort. An optimization is performed to determine the best control settings for targeted peak power and total daily energy increase minimization with example peak load reductions of 25+%.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Low-energy excitations in type-II Weyl semimetal T d - MoTe 2 evidenced through optical conductivity

Molybdenum ditelluride, MoTe 2 , is a versatile material where the topological phase can be readily tuned by manipulating the associated structural phase transition. The fine details of the band structure of MoTe 2 , key to understanding its topological properties, have proven difficult to disentangle experientially due to the multiband character of the material. Through experimental optical conductivity spectra, we detect two strong low-energy interband transitions. Both are linked to excitations between spin-orbit split bands. The lowest interband transition shows a strong thermal shift, pointing to a chemical potential that dramatically decreases with temperature. Finally, with the help of ab initio calculations and a simple two-band model, we give qualitative and quantitative explanations of the main features in the temperature-dependent optical spectra up to 400 meV.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

IoT-Based Comfort Control and Fault Diagnostics System for Energy-Efficient Homes

This project studies an Internet of Things (IoT)-based comfort control and fault diagnostics system (referred as iComfort in this report) for energy-efficient homes. The system delivers an occupant-comfort-oriented thermal environment adaptive to fault scenarios and achieves HVAC energy savings in a cost-effective and straightforward way. This smart iComfort home system consists of the following key features. 1) Cost-effectiveness and scalability of the entire hardware and software system: The system includes low-cost temperature, humidity, and airflow sensors, and a Raspberry Pi-based local hub that interfaces with the cloud and IoT-enabled devices. The cost is low, not only for sensors, but also the costs associated with sensor installation, system setup and commissioning, data communication and storage, and data analytics (e.g., the development of automated fault detection and diagnosis (AFDD), as well as adaptive control strategies that are both computationally efficient and practical to implement). 2) Energy performance and user satisfaction: The system delivers user satisfaction and energy savings. This includes a) ease of use, b) optimal occupant thermal comfort, and c) accurate system feedback (e.g., low false alarm of AFDD strategies). 3) Favorable demonstrated prototype performance: The prototype tested at the Pacific Northwest National Laboratory (PNNL) Lab Homes demonstrates the accuracy of fault detections and diagnoses and shows thermal comfort improvement and energy savings through adaptive and optimal HVAC operations.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Housing-Performance Atlas of Baltimore Row Homes: Archetype-Based Multi-Hazard Baseline of Energy, Heat, Survivability, and Durability

Baltimore’s historic row-home neighborhoods face escalating risks to energy, heat, and durability under intensifying climate stress. This study develops a Housing-Performance Atlas that quantifies multi-hazard performance for eight representative archetypes using DesignBuilder/EnergyPlus Version 7.3.1.003, under Baltimore TMY3 boundary conditions. Performance is evaluated across the following four adaptation domains: energy use intensity, passive survivability during 72 h outage events, roof overheating exposure (>150 °F exceedance hours), and material service life derived from ISO 15686 and synthesized into Lean and Full Deficit Indices for comparative resilience ranking. Results show that EUI ranged from 46.7 to 67.6 kBtu ft −2 ·yr −1 , survivability from 0 to 23 h, and roof temperatures exceeded 150 °F for 150–210 h, shortening roof service life by up to 10 years. Composite Lean and Full Deficit Indices ranged 7.8–92.4, ranking Model 5 (end-unit, flat roof, two-story with basement) as the most resilient configuration and Model 8 (end-unit, pitched roof, three-story above-grade) as the least resilient due to compounded overheating and energy losses. Heat-related domains accounted for nearly 70% of overall resilience deficits, confirming thermal safety and roof reflectivity as retrofit priorities. The Housing-Performance Atlas establishes a reproducible diagnostic framework linking simulation, service life, and resilience metrics to guide cost-effective, climate-responsive retrofits in Baltimore’s aging urban housing stock.

Housing-Performance atlas↗

Spinoff 2013

Topics covered include: Innovative Software Tools Measure Behavioral Alertness; Miniaturized, Portable Sensors Monitor Metabolic Health; Patient Simulators Train Emergency Caregivers; Solar Refrigerators Store Life-Saving Vaccines; Monitors Enable Medication Management in Patients' Homes; Handheld Diagnostic Device Delivers Quick Medical Readings; Experiments Result in Safer, Spin-Resistant Aircraft; Interfaces Visualize Data for Airline Safety, Efficiency; Data Mining Tools Make Flights Safer, More Efficient; NASA Standards Inform Comfortable Car Seats; Heat Shield Paves the Way for Commercial Space; Air Systems Provide Life Support to Miners; Coatings Preserve Metal, Stone, Tile, and Concrete; Robots Spur Software That Lends a Hand; Cloud-Based Data Sharing Connects Emergency Managers; Catalytic Converters Maintain Air Quality in Mines; NASA-Enhanced Water Bottles Filter Water on the Go; Brainwave Monitoring Software Improves Distracted Minds; Thermal Materials Protect Priceless, Personal Keepsakes; Home Air Purifiers Eradicate Harmful Pathogens; Thermal Materials Drive Professional Apparel Line; Radiant Barriers Save Energy in Buildings; Open Source Initiative Powers Real-Time Data Streams; Shuttle Engine Designs Revolutionize Solar Power; Procedure-Authoring Tool Improves Safety on Oil Rigs; Satellite Data Aid Monitoring of Nation's Forests; Mars Technologies Spawn Durable Wind Turbines; Programs Visualize Earth and Space for Interactive Education; Processor Units Reduce Satellite Construction Costs; Software Accelerates Computing Time for Complex Math; Simulation Tools Prevent Signal Interference on Spacecraft; Software Simplifies the Sharing of Numerical Models; Virtual Machine Language Controls Remote Devices; Micro-Accelerometers Monitor Equipment Health; Reactors Save Energy, Costs for Hydrogen Production; Cameras Monitor Spacecraft Integrity to Prevent Failures; Testing Devices Garner Data on Insulation Performance; Smart Sensors Gather Information for Machine Diagnostics; Oxygen Sensors Monitor Bioreactors and Ensure Health and Safety; Vision Algorithms Catch Defects in Screen Displays; and Deformable Mirrors Capture Exoplanet Data, Reflect Lasers.

Source record↗

The Hydrothermal System at Home Plate in Gusev Crater, Mars: Formation of High Silica Material by Acid-Sulfate Alteration of Basalt

The Alpha Particle X-ray Spectrometer (APXS) instrument on the Mars Exploration Rover (MER) Spirit measured three targets on or adjacent to Home Plate in Gusev Crater that have unusually high SiO2 concentrations (68% to 91%), unusually low FeO concentrations (1% to 7%, with total Fe as FeO), and unusually high TiO2/FeO ratios (0.2 to 1.2 by weight) [1]. Two targets (Kenosha Comets and Lefty Ganote) are located on high albedo soil (Gertrude Weise) that was exposed by the rover wheels, and one target is a float rock called Fuzzy Smith. Kenosha Comets has the highest SiO2 concentration, lowest FeO concentration, and highest TiO2/FeO ratio. Mineralogical evidence from the MER Miniature Thermal Emission Spectrometer (Mini-TES) suggests that the SiO2 is present as amorphous (noncrystalline) SiO2 at Gertrude Weise and nearby targets [2,3]. Mini-TES data were not acquired for Fuzzy Smith. Home Plate is considered to have an explosive volcanic origin, resulting when basaltic magma came into contact with ground water or ice [4]. Within ~50 m to 1 km of Home Plate are sulfate rich soil deposits (Paso Robles class soils with 22-35% SO3) which are considered to be probable fumarolic and/or hydrothermal deposits associated with the volcanism [5]. We develop the model here, suggested by [5], that the high-silica materials are another manifestation of acid-sulfate processes associated with fumarolic and hydrothermal activity at Home Plate. This is done by analogy with basaltic materials altered by acid sulfate processes on the Island of Hawaii.

Morris, R. V.↗

Physical Sciences Vistas (Issue 3 2020)

In this issue, highlights of our outstanding R&D supporting the Laboratory’s nuclear security mission include the following. 1. The essential nuclear materials science contributions of MST’s Materials Properties Team to a range of Lab missions, operations, and initiatives. 2. Work in the Sigma Complex supporting NNSA’s Advanced Manufacturing Development milestones by members of Sigma Division and colleagues across the Laboratory and other NNSA sites. 3. Greg Dale’s role in the Lab’s molybdenum program and today as a technical lead on the Scorpius project. 4. Measurements that reveal the role thermal interfaces play in dynamic compression experiments. 5. The first-ever synthesis of an actinide framework, which offers opportunities for understanding these structures as potential radioactive waste forms and provides new models of actinide species transport in the environment. This issue also showcases, as part of our commitment to simultaneous excellence in mission operations and community relations, the successful high-hazard repair of the LANSCE accelerator, which resulted in a large team Laboratory Distinguished Performance Award, and a virtual Summer Physics Camp for Young Women that brought together participants from around the world, even as COVID kept them socially distant in their homes.

36 MATERIALS SCIENCE↗

Reducing Exposures to Airborne Particles Through Improved Filtration: A High-Level Modeling Analysis

Indoor airborne particulates are well-known health hazards and filtration is one common method of reducing exposures. Based on our previously developed Regional Shelter Analysis methodology and parameters that characterize the existing US building stock, we perform a high-level assessment of the potential benefits of upgrading existing filters in furnace and in heating, ventilation, and air conditioning systems using off-the-shelf filters. We use three metrics to assess the improvement: Building Transmission Factor (a measure of protection against outdoor airborne particles), Indoor Normalized Time and Space Integrated Air Concentration (a measure of indoor exposure to indoor-origin airborne particles), and Building Exit Fraction (fraction of indoor airborne particles that are released to the outdoor atmosphere). We also discuss the potential reduction in regional exposures due to particles exiting the building and exposing downwind building occupants. Our modeling indicates that while buildings provide their occupants passive protection against airborne particulate hazards, including but not limited to PM 2.5 , PM 10 , and wildfire smoke; improving particle filtration efficiency may further improve this protection. The degree of improvement varies with particle size and building type. Of the building types studied, apartments are predicted to benefit most, with greater than a factor of 2 improvement (≥50% reduction in exposures) for 1 µm particle exposures when using MERV 7 to 12 rated filters. Non-residential buildings were notably less responsive to improved filtration but had the highest Building Exit Fractions with 30% to 40% of indoor airborne particles released to the outdoor atmosphere (apartment buildings only released 6% to 9%). Improvements predicted for single family homes were intermediate between apartments and non-residential buildings. Improvements in the Regional Exposure metric are larger, ranging from a factor of 2.5x to 10x for residences (when using MERV 7 to 12 rated filters) and up to 25x for large apartments with MERV 14 or 15 rated filters. The results of our modeling analysis are broadly consistent with the limited experimental data and modeling results available in the literature.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Experimental and Modeled Assessment of Interventions to Reduce PM2.5 in a Residence during a Wildfire Event

Increasingly large and frequent wildfires affect air quality even indoors by emitting and dispersing fine/ultrafine particulate matter known to pose health risks to residents. With this health threat, we are working to help the building science community develop simplified tools that may be used to estimate impacts to large numbers of homes based on high-level housing characteristics. In addition to reviewing literature sources, we performed an experiment to evaluate interventions to mitigate degraded indoor air quality. We instrumented one residence for one week during an extreme wildfire event in the Pacific Northwest. Outdoor ambient concentrations of PM2.5 reached historic levels, sustained at over 200 μg/m3 for multiple days. Outdoor and indoor PM2.5 were monitored, and data regarding building characteristics, infiltration, and mechanical system operation were gathered to be consistent with the type of information commonly known for residential energy models. Two conditions were studied: a high-capture minimum efficiency rated value (MERV 13) filter integrated into a central forced air (CFA) system, and a CFA with MERV 13 filtration operating with a portable air cleaner (PAC). With intermittent CFA operation and no PAC, indoor corrected concentrations of PM2.5 reached 280 μg/m3, and indoor/outdoor (I/O) ratios reached a mean of 0.55. The measured I/O ratio was reduced to a mean of 0.22 when both intermittent CFA and the PAC were in operation. Data gathered from the test home were used in a modeling exercise to assess expected I/O ratios from both interventions. The mean modeled I/O ratio for the CFA with an MERV 13 filter was 0.48, and 0.28 when the PAC was added. The model overpredicted the MERV 13 performance and underpredicted the CFA with an MERV 13 filter plus a PAC, though both conditions were predicted within 0.15 standard deviation. The results illustrate the ways that models can be used to estimate indoor PM2.5 concentrations in residences during extreme wildfire smoke events.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

Kinetics of Pyrolysis and Thermal Evolution of Negev Desert Lithologies

The Negev desert in Israel is home to large quantities of organic-rich, shallow marine sedimentary lithologies that could potentially accommodate the disposal of spent nuclear fuel. Previous thermal analyses of Negev carbonates have focused on industrially relevant considerations such as natural gas and oil extraction or pyrolysis for recovering hydrocarbon fuels. Here, this study addresses thermal evolution of the Negev organic-rich carbonate, siliceous, and phosphorite rocks and associated chemical, mineralogical, and microstructural changes that may occur under prolonged thermal loading in the vicinity of spent nuclear fuel disposal systems. Our employed methods include high-temperature X-ray diffraction, high-temperature infrared spectroscopy, and thermal analysis integrating thermogravimetry, differential scanning calorimetry, and mass spectrometry. Further, we apply iterative iso-conversional model-free methods to derive kinetic parameters for thermal decomposition of the Negev organic-rich carbonate rocks from 200 to 550 °C. Our results have provided mechanistic insights into the thermal evolution encompassing water desorption, decomposition of organic matter, and decarbonation of carbonate phases.

58 GEOSCIENCES↗

Empirical evidence that mean soil contaminant concentration is not a conservative indicator of external exposure to wildlife

Adequate information on external exposure is often a limiting factor in ecological risk assessments because of a lack of exposure data for free-ranging animals as they interact with a heterogeneous distribution of contaminants. Instead, most wildlife exposure data are estimated from model simulations. However, empirical exposure data are rarely available to verify model results, or to test fundamental assumptions inherent in exposure assessments. We used novel, GPS-coupled radiation dosimeters on reindeer (Rangifer tarandus) to quantify their external exposure for five months in a Chernobyl fallout affected mountainous area of Norway. The exposure data were then used to test a fundamental assumption in screening-level risk assessments: Mean soil contaminant concentrations can be used to conservatively estimate chronic external exposures to representative animals. External exposure and GPS coordinates were obtained hourly and compared to model simulations of exposure based on airborne surveys of 137 Cs soil contamination. Our objectives were to determine 1) if modelled dose estimates based on mean 137 Cs soil concentrations were conservative, and 2) if modelled dose estimates could be improved by adjusting for spatial–temporal heterogeneity of contaminants using 137 Cs concentrations within reindeers’ GPS-defined home ranges and core areas. We found that external exposure modelled from mean soil contaminant concentrations underestimated exposure by 70% compared to empirical measurements from GPS-dosimeter collars worn on individual animals. Using area-weighted mean contaminant levels within the animals’ home range improved the model estimates, but still underestimated the field dosimeter data by 53%. The best estimate of external exposure was obtained when high-use areas within their home range, along with spatial heterogeneity of the contaminant, was accounted for by using area-weighted mean soil contaminant levels within GPS-derived core areas. Accounting for temporal use of core areas within animals’ home range provided a 24% improvement. Here, a comparison of our analyses to similar work performed on Chernobyl wolves found the two studies concur that risk assessors should be cautious in relying on the paradigm of using averaged soil contaminant levels to provide conservative estimates of external exposure to representative individuals. Results of modelled external exposure based on mean soil contaminant concentrations could misguide assessors and cause inappropriate management decisions.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

Uncontrolled Electric Vehicle Charging Impacts on Distribution Electric Power Systems with Primarily Residential, Commercial or Industrial Loads

An increase in Electric Vehicles (EV) will result in higher demands on the distribution electric power systems (EPS) which may result in thermal line overloading and low voltage violations. To understand the impact, this work simulates two EV charging scenarios (home- and work-dominant) under potential 2030 EV adoption levels on 10 actual distribution feeders that support residential, commercial, and industrial loads. The simulations include actual driving patterns of existing (non-EV) vehicles taken from global positioning system (GPS) data. The GPS driving behaviors, which explain the spatial and temporal EV charging demands, provide information on each vehicles travel distance, dwell locations, and dwell durations. Then, the EPS simulations incorporate the EV charging demands to calculate the power flow across the feeder. Simulation results show that voltage impacts are modest (less than 0.01 p.u.), likely due to robust feeder designs and the models only represent the high-voltage (“primary”) system components. Line loading impacts are more noticeable, with a maximum increase of about 15%. Additionally, the feeder peak load times experience a slight shift for residential and mixed feeders (≈1 h), not at all for the industrial, and 8 h for the commercial feeder.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Early Lab scientists had questions, Plastic Man gave them answers

He was a willing subject in countless scientific experiments, a superstar of health physics, as well as a favorite photo prop -- and not just around Halloween time. He was Plastic Man. Beginning in the mid-1950s, the Lab (then called Los Alamos Scientific Laboratory) often relied on several life-sized synthetic test subjects to avoid experimenting on people. In the early days of the Laboratory, not much was known about how different radioisotopes interacted with the human body and how much it absorbed from different radiation sources. Answering queries like these is where Plastic Man came in. For example, during the 1950s and 1960s, the Lab was tasked with developing nuclear rockets for space exploration under the Rover Program. One of the concerns was how astronauts might be affected when exposed to radiation from these rocket engines. So, the Lab’s health group set up an experiment in which Plastic Man was placed in close proximity to an experimental Rover nuclear rocket engine. Running experiments like this using Plastic Man kept humans safer. How life-like was he? There were actually two variations of Plastic Man. Both had hard plastic exteriors, but one of the models encased a real human skeleton. They also had movable joints and simulated organs, such as a liver, a spleen, kidneys, lungs and a thyroid. Although Plastic Man in its entirety was used in experiments, much of the data collected were from research conducted inside on these replicated organs. In time, technology advanced and Plastic Man was able to retire from the Lab. He found a new home in 1964 as a display at the Laboratory’s science museum, and is sometimes displayed today in the Bradbury Science Museum in downtown Los Alamos.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

Connecting the Radiative Influences of Aerosol upon the Mass Flux Profiles of Shallow Cumuli across the Southeast Atlantic Ocean Basin and its Boundaries (Final Report)

The Atlantic Ocean covers approximately 25% of Earth’s surface and the atmosphere above it is home to a complex array of clouds and aerosols that have important influences on regional and global weather and climate. These influences must be accurately depicted in short range, medium range, seasonal, and climate forecast models. Conditions over the tropical Atlantic are particularly complex due to continental scale plumes of dust from the Sahara Desert and smoke from agricultural burning in Africa that drift across the Atlantic Ocean basin toward the Americas. These plumes are often found meandering in the lower atmosphere above shallow tropical clouds that form above the ocean surface, presumably mingling with these clouds on occasion due to convective mixing processes. Elevated dust and smoke particles absorb incoming sunlight and substantially warm the marine atmosphere in the layer in which they are present. This warming may alter the thermal stability of the marine atmosphere and may throttle or enhance the development of clouds, change their internal structure and the rate at which they precipitate. Alternatively, it may isolate the lower atmosphere from drier layers above enabling water vapor to accumulate near the ocean surface potentially leading to the development of deeper convection. Our study was organized around the principal concept of determining the impact of African smoke and dust plumes upon cloud development at ASI and understanding how a popular shallow convection parameterization used in models responds to the presence of this aerosol. We analyzed observations collected during the US Department of Energy (DOE) Layered Atlantic Smoke Interactions with Clouds (LASIC) campaign using the Atmospheric Radiation Measurement Program’s Mobile Facility #1 (AMF-1), which was deployed to Ascension Island (ASI) in Southeastern Atlantic for a one-year period. Ascension Island is immediately downwind from an African source of these plumes, but far enough removed to enable the lower atmosphere to have reacted to their presence. A main goal of our study was to compute radiative heating rate profiles over Ascension Island and along the trajectory from the biomass burning regions along coastal Africa to Ascension Island. To compute the radiative heating rate due to aerosols and clouds, we employed observed profiles of temperature, humidity, and clouds from LASIC alongside aerosol optical properties from the Modern-era Retrospective analysis for Research and Applications Version 2 (MERRA-2), as input for the Rapid Radiation Transfer Model (RRTM). Radiative heating was also assessed across the southeast Atlantic Ocean using an ensemble of back trajectories from the Hybrid Single Particle Lagrangian Integrated Trajectory (HYSPLIT) model. We were successful in this effort and the resulting publication is already being cited despite its relatively short lifetime in the literature. The second part of our study involved the process-level representation of the clouds observed over the Southeastern Atlantic in models. Our initial task, upon which the balance of this portion of the study depended, was to evaluate the representativeness of the clouds observed by AMF-1. What orographic influence did Ascension Island have on the measured cloud structure? We set out to answer this question by trying to separate observations that were clearly indicative of orographic forcing from those that were representative of open ocean. The siting of AMF-1, which was 340-m above sea-level on the slope of a steep escarpment, proved demonstrably problematic for cloud process measurements. Despite considerable effort using multiple approaches including artificial intelligence (AI), we were unable to successfully compensate for the orographic forcing present at the AMF-1 site on ASI and, hence, produce process-level summaries of the convective mass flux representative of open ocean over the Southeastern Atlantic. Even though the project has officially ended, we are making a final attempt using two new types of clustering algorithm (i.e., AI) on the recommendation of a former student, who is an expert in this area. Since we have only recently begun to test these new AI schemes, the recommendations from the second part of our project outlined below are based on our experience at the time of this report.

54 ENVIRONMENTAL SCIENCES↗

McMurdo Dry Valleys, Antarctica - A Mars Phoenix Mission Analog

The Phoenix mission (PHX; May 25 - Nov. 2, 2008) studied the north polar region of Mars (68deg N) to understand the history of water and potential for habitability. Phoenix carried with it a wet chemistry lab (WCL) capable of determining the basic solution chemistry of the soil and the pH value, a thermal and evolved-gas analyzer capable of determining the mineralogy of the soil and detecting ice, microscopes capable of seeing soil particle shapes, sizes and colors at very high resolution, and a soil probe (TECP) capable of detecting unfrozen water in the soil. PHX coincided with an international effort to study the Earth s polar regions named the International Polar Year (IPY; 2007-2008). The best known Earth analog to the Martian high-northern plains, where Phoenix landed, are the McMurdo Dry Valleys (MDV), Antarctica (Fig. 1). Thus, the IPY afforded a unique opportunity to study the MDV with the same foci - history of water and habitability - as PHX. In austral summer 2007, our team took engineering models of WCL and TECP into the MDV and performed analgous measurements. We also collected sterile samples and analyzed them in our home laboratories using state-of-the-art tools. While PHX was not designed to perform biologic analyses, we were able to do so with the MDV analog samples collected.

Tamppari, L. K.↗

The cost savings potential of controlling solar thermal collectors with storage for time-of-use electricity rates

Homes and commercial buildings account for roughly 40% of U.S. energy consumption. A significant portion of this energy consumption, and therefore utility cost, comes from domestic hot-water use. Solar collectors such as flat plate collectors, evacuated tubes, and combined photovoltaic/thermal panels, are renewable options that collect thermal energy and could help reduce utility costs. Hot water is generated by pumping a working fluid through the solar collector, where the fluid captures thermal energy via absorbed solar radiation incident on the collector surface. The collection of heat coincides with the availability of solar radiation, but the best time to use this thermal energy depends on the utility rate at a given time, which often changes throughout the day. In this work, we implement and simulate a control strategy using Transient System Simulation Tool (TRNSYS) that reduces utility costs by controlling when the system stores and uses thermal energy based on solar availability and time-of-use electricity rates. Our modeled results show that the control strategy can reduce utility costs associated with using hot water between 3% and 30%. Here, we also show how the on-peak utility rates, the size and type of the solar collectors, and the location's climate impact the results.

14 SOLAR ENERGY↗

Large Area Nondestructive Evaluation of a Fatigue Loaded Composite Structure

Large area nondestructive evaluation (NDE) inspections are required for fatigue testing of composite structures to track damage initiation and growth. Of particular interest is the progression of damage leading to ultimate failure to validate damage progression models. In this work, passive thermography and acoustic emission NDE were used to track damage growth up to failure of a composite three-stringer panel. Fourteen acoustic emission sensors were placed on the composite panel. The signals from the array were acquired simultaneously and allowed for acoustic emission location. In addition, real time thermal data of the composite structure were acquired during loading. Details are presented on the mapping of the acoustic emission locations directly onto the thermal imagery to confirm areas of damage growth leading to ultimate failure. This required synchronizing the acoustic emission and thermal data with the applied loading. In addition, processing of the thermal imagery which included contrast enhancement, removal of optical barrel distortion and correction of angular rotation before mapping the acoustic event locations are discussed.

Joseph N Zalameda↗