Search NASA⌕ Search

SEARCH · Search NASA

Results for “Hydrogen Insertion”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

62 records · Page 4

Space Nuclear Propulsion for Deep Space Science Missions

The use of nuclear thermal propulsion (NTP) 1 and nuclear electric propulsion (NEP) 2 systems on deep space science missions to the outer planets and into the interstellar medium 3 can yield significant spacecraft system and mission performance benefits and improvements relative to the use of conventional chemical propulsion systems. Several recent and ongoing programs are developing the technologies and systems required to realize a near-term deep space nuclear propulsion capability. NTP provides improved propulsion efficiencies compared to chemical propulsion, while also providing substantial thrust. This combination of high thrust and increased specific impulse (I_sp) provides high acceleration and extended thrusting periods, enabling greatly reduced trip-times on certain types of missions compared to various propulsive alternatives. For examples, compared to a baseline mission using chemical propulsion, NTP-powered missions to Jupiter or Uranus could deliver approximately 2.4-3.6 times more payload (in the case of Jupiter, the payload delivery is significantly larger than the Juno spacecraft). In this comparison, the higher end of the payload advantage is obtained when the trip time is held equal for the NTP-powered vehicle and a vehicle using a chemical propulsion departure stage. NTP systems are presently under development by multiple government agencies. NASA’s Space Nuclear Propulsion (SNP) project aims to demonstrate a hydrogen-fed NTP engine at 900 s specific impulse (I_sp) and approximately 10-15 klb_f of thrust. DARPA’s Demonstration Rocket for Agile Cislunar Operations (DRACO) program is targeting a demonstration of an NTP system in the cislunar space between the Earth and the Moon. An appropriately phased development plan that applies the development of the reactor technology for an NTP engine in this performance class and leverages mature, existing liquid rocket component hardware provides a path to a lower cost propulsion system that can be realized on a shorter development schedule. NEP, with high Isp in the 2,000-8,000 s range, can also provide advantages over chemical propulsion, including a much greater payload delivery mass and the flexibility for planners to trade between delivered mass and a wider window of mission trajectory options. Electric propulsion (EP) systems have demonstrated great utility, performing notably on the Dawn mission to enable rendezvous and orbital insertion at two separate bodies, Vesta and Ceres. An NEP-powered vehicle would have a similar capability to visit multiple bodies, loitering at each before moving to the next. A 10 kW_e NEP system provides a power- rich environment on the spacecraft that is simply not possible using present radioisotope power systems, giving mission planners more scientific instrument and communication hardware options. Several programs and projects are presently developing NEP systems and subsystems in the 10 kW_e power range, leveraging past reactor work and recent nuclear power generation risk-reduction demonstration activities such as the Demonstration Using Flattop Fission (DUFF) and the Kilopower Reactor Using Stirling TechnologY (KRUSTY). The goal of the Air Force Research Laboratory’s Joint Energy Technology Supplying On-Orbit Nuclear Power (JETSON) program is an in-space demonstration vehicle that has a 10 kW_e -class fission power source. These past and present efforts can be combined with the ongoing development of 10 kW_e -class electric propulsion systems (notably the NEXT-C ion thruster or the Hall-effect thrusters for Power and Propulsion Element of the Lunar Gateway) to provide a pathway to a low-cost, reliable NEP system for deep space science application.

Kurt A. Polzin↗

Space Nuclear Propulsion for Deep Space Science Missions

The use of nuclear thermal propulsion (NTP) 1 and nuclear electric propulsion (NEP) 2 systems on deep space science missions to the outer planets and into the interstellar medium 3 can yield significant spacecraft system and mission performance benefits and improvements relative to the use of conventional chemical propulsion systems. Several recent and ongoing programs are developing the technologies and systems required to realize a near-term deep space nuclear propulsion capability. NTP provides improved propulsion efficiencies compared to chemical propulsion, while also providing substantial thrust. This combination of high thrust and increased specific impulse (I_sp) provides high acceleration and extended thrusting periods, enabling greatly reduced trip-times on certain types of missions compared to various propulsive alternatives. For examples, compared to a baseline mission using chemical propulsion, NTP-powered missions to Jupiter or Uranus could deliver approximately 2.4-3.6 times more payload (in the case of Jupiter, the payload delivery is significantly larger than the Juno spacecraft). In this comparison, the higher end of the payload advantage is obtained when the trip time is held equal for the NTP-powered vehicle and a vehicle using a chemical propulsion departure stage. NTP systems are presently under development by multiple government agencies. NASA’s Space Nuclear Propulsion (SNP) project aims to demonstrate a hydrogen-fed NTP engine at 900 s specific impulse (I_sp) and approximately 10-15 klb_f of thrust. DARPA’s Demonstration Rocket for Agile Cislunar Operations (DRACO) program is targeting a demonstration of an NTP system in the cislunar space between the Earth and the Moon. An appropriately phased development plan that applies the development of the reactor technology for an NTP engine in this performance class and leverages mature, existing liquid rocket component hardware provides a path to a lower cost propulsion system that can be realized on a shorter development schedule. NEP, with high Isp in the 2,000-8,000 s range, can also provide advantages over chemical propulsion, including a much greater payload delivery mass and the flexibility for planners to trade between delivered mass and a wider window of mission trajectory options. Electric propulsion (EP) systems have demonstrated great utility, performing notably on the Dawn mission to enable rendezvous and orbital insertion at two separate bodies, Vesta and Ceres. An NEP-powered vehicle would have a similar capability to visit multiple bodies, loitering at each before moving to the next. A 10 kW_e NEP system provides a power- rich environment on the spacecraft that is simply not possible using present radioisotope power systems, giving mission planners more scientific instrument and communication hardware options. Several programs and projects are presently developing NEP systems and subsystems in the 10 kW_e power range, leveraging past reactor work and recent nuclear power generation risk-reduction demonstration activities such as the Demonstration Using Flattop Fission (DUFF) and the Kilopower Reactor Using Stirling TechnologY (KRUSTY). The goal of the Air Force Research Laboratory’s Joint Energy Technology Supplying On-Orbit Nuclear Power (JETSON) program is an in-space demonstration vehicle that has a 10 kW_e -class fission power source. These past and present efforts can be combined with the ongoing development of 10 kW_e -class electric propulsion systems (notably the NEXT-C ion thruster or the Hall-effect thrusters for Power and Propulsion Element of the Lunar Gateway) to provide a pathway to a low-cost, reliable NEP system for deep space science application.

Kurt A. Polzin↗

Real-Time Deposition Monitor for Ultrathin Conductive Films

A device has been developed that can be used for the real-time monitoring of ultrathin (2 or more) conductive films. The device responds in less than two microseconds, and can be used to monitor film depositions up to about 60 thick. Actual thickness monitoring capability will vary based on properties of the film being deposited. This is a single-use device, which, due to the very low device cost, can be disposable. Conventional quartz/crystal microbalance devices have proven inadequate to monitor the thickness of Pd films during deposition of ultrathin films for hydrogen sensor devices. When the deposited film is less than 100 , the QCM measurements are inadequate to allow monitoring of the ultrathin films being developed. Thus, an improved, high-sensitivity, real-time deposition monitor was needed to continue Pd film deposition development. The new deposition monitor utilizes a surface acoustic wave (SAW) device in a differential delay-line configuration to produce both a reference response and a response for the portion of the device on which the film is being deposited. Both responses are monitored simultaneously during deposition. The reference response remains unchanged, while the attenuation of the sensing path (where the film is being deposited) varies as the film thickness increases. This device utilizes the fact that on high-coupling piezoelectric substrates, the attenuation of an SAW undergoes a transition from low to very high, and back to low as the conductivity of a film on the device surface goes from nonconductive to highly conductive. Thus, the sensing path response starts with a low insertion loss, and as a conductive film is deposited, the film conductivity increases, causing the device insertion loss to increase dramatically (by up to 80 dB or more), and then with continued film thickness increases (and the corresponding conductivity increases), the device insertion loss goes back down to the low level at which it started. This provides a continuous, real-time monitoring of film deposition. For use with different films, the device would need to be calibrated to provide an understanding of how film thickness is related to film conductivity, as the device is responding primarily to conductivity effects (and not to mass loading effects) in this ultrathin film regime.

Hines, Jacqueline↗

Cryogenic Orbital Testbed (CRYOTE) Ground Test Article, Final Report

Liquid propulsion has been used since Robert Goddard started developing a liquid oxygen (LO2) and gasoline powered rocket and fired it in 1923 (Ref. 1). In the following decades engineers settled on the combination of liquid hydrogen (LH2) and LO2 as the most efficient propellant combination for in-space travel. Due to their low temperatures (LH2 at 20 K and LO2 at 90 K), they require special handling and procedures. General Dynamics began developing LO2 and LH2 upper stages in 1956 in the form of Centaur, these efforts were soon funded by the Department of Defense in conjunction with NASA (beginning in 1958) (Ref. 2). Meanwhile NASA also worked with McDonnell Douglas to develop the SIV-B stage for the Saturn V rocket. In the subsequent years, the engineers were able to push the Centaur to up to 9 hr of orbital lifetime and the SIV-B to up to 6 hr. Due to venting the resultant boil-off from the high heat loads through the foam insulation on the upper stages, both vehicles remained in a settled configuration throughout the flights, thus the two phases of propellant (liquid and vapor) were separated at a known location. The one exception to this were the Titan/Centaur missions, which thanks to the lower boil-off using three layers of multilayer insulation (MLI), were able to coast unsettled for up to 5.25 hr during direct geosynchronous orbit insertion missions. In the years since there has been a continuous effort to extend the life of these upper stages from hours to days or even months.

Joule-Thompson Effect↗

Multiple Probe Measurements at Uranus Motivated By Spatial Variability

Motivation: Spatial variations in the temperature field and composition of Uranus' atmosphere demonstrate a need for multiple entry probes to characterize vertical profiles in multiple locations. We will review variation of composition and temperature, which are produced by dynamical processes on a range of scales from global (polar anomalies, zonal bands) to regional (vortices, storms) [1–2]. In particular, the spatial variation of convective activity is not well understood based on existing remote sensing observations [3]. Understanding how these processes operate, and how they modulate variable composition, is key to constraining bulk atmospheric abundances. Abundances in turn provide cosmochemical constraints on planetary origins. Secondary probes at Uranus: Key measurements for secondary probes are temperature-pressure profiles, along with compositional profiles. Radio occultations are limited to shallow levels less than ~2 bar [4]. In situ temperature-pressure measurements (or atmospheric structure measurements) can unambiguously extend these results to deeper levels. Measurements with vertical resolution of at least 2 km are needed to characterize anomalies like the 1.2-bar feature from the Voyager 2 occultation at 2–6° S [4], which supports a range of temperature gradients depending on assumptions of composition. Simultaneous measurements of temperature, pressure, and composition are key to understanding this class of features. Species such as methane, hydrogen sulfide, and ammonia must be measured along a probe descent profile because they vary over several orders of magnitude due to the strong temperature dependence of their saturation vapor pressures [e.g., 5]. Results of these measurements can be interpreted to understand the potential for moist convective activity in the atmosphere. Lessons from the other giant planets: On Jupiter, the Galileo Probe's entry into a meteorologically distinct five-micron hot spot led many to interpret the local composition as column-stretched, so that well-mixed abundances were reached at deeper levels than in surrounding, unperturbed regions [6–8]. Ground-based microwave measurements and Juno data now indicate that the deep depletion of ammonia is a very widespread atmospheric characteristic not limited to 5-µm hot spots [9–11]. But in the absence of multiple probes, we do not know if the other volatiles H2S and H2O behave in the same way. The open questions for the Jupiter case strongly motivate sending multiple probes to Uranus. On Saturn, retrievals of NH3 and PH3 abundances at shallow levels vary with latitude [12], but it is unknown how deep these differences extend, which is why a Saturn probe (or probes) was a mission theme for NASA's New Frontiers 4 and 5 opportunities [13]. Challenges for secondary probes: Cost is an issue due to the perception that it involves sacrifices to other mission elements. Spacecraft trajectories may be constrained by needs for orbit insertion that limit probe deliveries to different latitudes, and additional limitations may be placed on communication windows for probe descent phases (particularly if multiple probes are released from the orbiter simultaneously) [14]. Finally, composition sensors for miniature secondary probes are not at the required technological maturity [15]. Mass spectrometers are typically too large, massive, and powerhungry, while smaller nanosensors are only beginning to be developed for planetary missions. Finally, the need for probe survival heating is most easily met by radioisotope heat sources, but these require regulatory approvals that are even more difficult to satisfy compared to standard environmental reviews [16], unless the secondary probe is designed as a core element of a mission. References: [1] Molter E.M., et al. (2021) PSJ, 2, 3. [2] Rowe-Gurney N., et al. (2021) Icar, 365, 114506. [3] Hueso R., Sánchez-Lavega A. (2019) SSRv, 215, 52. [4] Lindal G.F., et al. (1987) JGR, 92, 14987– 15001. [5] Simon A.A., et al. (2022) RemS, 14, 1518. [6] Atreya, S.K., et al. (1997) in The Three Galileos: The Man, the Spacecraft, the Telescope, pp. 249–260 (C. Barbieri et al., eds.). [7] Showman A.P., Ingersoll A.P. (1998) Icar, 132, 205–220. [8] Friedson A.J. (2005) Icar, 177, 1–17. [9] de Pater I., et al. (2001) Icar, 149, 66–78. [10] Li C., et al. (2017) GeoRL, 44, 5317–5325. [11] de Pater I., et al. (2019) Icar, 322, 168–191. [12] Fletcher L.N., et al. (2009) Icar, 202, 543–564. [13] National Research Council (2011) Vision and Voyages. [14] Sayanagi K.M., et al. (2020) SSRv, 216, 72. [15] Wong M.H. et al. (2021) BAAS, 53, 486. [16] Zide A., Mendoza-Hill A., Cheney D. (2022) COSPAR Abstracts H0.6-0012-22.

Michael H Wong↗

A Low Cost Spacecraft Architecture for Robotic Lunar Exploration Projects

A program of frequent, capable, but affordable lunar robotic missions prior to return of humans to the moon can contribute to the Vision for Space Exploration (VSE) NASA is tasked to execute. The Lunar Reconnaissance Orbiter (LRO) and its secondary payload are scheduled to orbit the moon, and impact it, respectively, in 2008. It is expected that the sequence of missions occurring for approximately the decade after 2008 will place an increasing emphasis on soft landed payloads. These missions are requited to explore intrinsic characteristics of the moon, such as hydrogen distribution in the regolith, and levitated dust, to demonstrate the ability to access and process in-situ resources, and to demonstrate functions critical to supporting human presence, such as automated precision navigation and landing. Additional factors governing the design of spacecraft to accomplish this diverse set of objectives are: operating within a relatively modest funding profile, the need tb visit multiple sites (both polar and equatorial) repeatedly, and to use the current generation of launch vehicles. In the US, this implies use of the Evolved Expendable Launch Vehicles, or EELVs, although this design philosophy may be extended to launch vehicles of other nations, as well. Many of these factors are seemingly inconsistent with each other. For example, the cost of a spacecraft usually increases with mass; therefore the desire to fly frequent, modestly priced spacecraft seems to imply small spacecraft (< 1 Mt, injected mass). On the other hand, the smallest of the EELVs will inject approx. 3 Mt. on a Trans Lunar Injection (TLI) trajectory md would therefore be wasteful or launching a single, small spacecraft. Increasing the technical capability of a spacecraft (such as autonomous navigation and soft landing) also usually increases cost. A strategy for spacecraft design that meets these conflicting requirements is presented. Taken together, spacecraft structure and propulsion subsystems constitute the majority of spacecraft mass; saving development and integration cost on these elements is critical to controlling cost. Therefore, a low cost, modular design for spacecraft structure and propulsion subsystems is presented which may be easily scaled up or down for either insertion into lunar orbit or braking for landing on the lunar surface. In order to effectively use the approx.3 Mt mass-to-TLI of the EELV, two low cost spacecraft will be manifested on the same launch. One spacecraft will be located on top of the other for launch and the two will have to be released in sequence in order to achieve all mission objectives. The two spacecraft could both be landers, both orbiters, or one lander and one orbiter. In order to achieve mass efficiency, the body of the spacecraft will serve the dual purposes of carrying launch loads and providing attachment points for all the spacecraft subsystems. In order to avoid unaffordable technology development costs, small liquid propulsion components and autonomous, scene-matching navigation cameras may be adapted from military missile programs in order to execute precision soft landings.

Lemke, Lawrence G.↗

Combined Experimental and Modeling Study of the Interactions of Acid Gas with Common Spacecraft Surfaces for Fire Safety Applications

A fire in a spacecraft poses detrimental consequences and risks mission success in addition to crew safety. This is compounded during long-duration missions when the crew has limited options to recover from a fire. A common spacecraft fire concern is the smoldering of wire insulation, typically made from Polyvinyl chloride (PVC) or Polytetrafluoroethylene (PTFE). This creates acid gases such as Hydrogen Chloride (HCl), Hydrogen Fluoride (HF) and Hydrogen Cyanide (HCN). These poisonous gases are hazardous to the crew. They also interact with common surfaces within the spacecraft more than dominant combustion products such as CO2 and H2O. This makes them more difficult to track for potential fire detection techniques, or for postfire clean-up. It is imperative to be able to understand and predict the fate of these poisonous species in a microgravity environment in order to design a safe vehicle. HCl interacts with a number of materials inside a spacecraft. Primary among these materials is aluminum, which is abundantly used due to its strong and light weight nature. Aluminum has a natural oxide layer that protects it from corrosion but is typically treated to enhance this oxide layer. Among these treatments is a chromate conversion coating (CCC), which provides a thin enough protective oxide layer to still conduct electricity, and a traditional anodized material that has a thicker oxide layer that does not conduct electricity. Nomex is another common material found inside a spacecraft. It is a flame-resistant woven polymer that is related to nylon. This commercially available material is used for cargo storage bags and as a fire barrier. Physics-based models were developed to predict the uptake of HCl by these materials. The ultimate objective of these models is to predict the fate of HCl within the spacecraft so that sensors can be placed in meaningful locations in future missions based on the model predictions. To support these modeling efforts, experiments were performed in a cast acrylic test cell that measured the difference between the inlet and outlet concentration of HCl after inserting a sample rod of the test material. Different uptake capacities were realized for each type of sample tested. A computational fluid dynamics model (CFD) model of the reactor was then constructed that used a one-step global reaction rate with calibratable reaction (or kinetic) constants. These constants were calibrated to match the HCl uptake on the CCC aluminum samples, and the same kinetic constants were then tested for the stock and anodized aluminum samples. Model predictions matched the experimental data for the stock aluminum, and to a much lesser extent, the anodized aluminum. The model was additionally validated at different flow rates, sample surface areas, and inlet concentrations, and showed good agreement for all stock and CCC samples. The model did not accurately predict the HCl uptake in the anodized samples compared to the other two types of aluminum. Adjusting the kinetic constants and transport properties did little to improve the prediction. X-Ray Photoelectron Spectroscopy (XPS) was used to determine that the oxide layer thickness of anodized aluminum is approximately 5,000 nm, compared to 250 nm for CCC and 50 nm for stock. XPS also revealed presence of chlorine further down in the aluminum oxide layer in anodized samples than CCC and stock samples after the samples were saturated with HCl, indicating that accounting for diffusion of HCl into the oxide layer is important for accurate prediction of HCl uptake onto anodized aluminum. Consequently, a multi-scale model was developed and tested. First, a single pore inside the anodized aluminum oxide layer was modeled and is referred to as the pore-scale model. In this model, HCl diffused through the pore and reacted with the aluminum oxide pore wall to create aluminum chloride. The sample was then saturated when the mass transfer resistance through the growing aluminum chloride layer became too large for the HCl to reach the aluminum oxide wall and continue the reaction. This pore-scale model was coupled to the reactor-scale model using a concentration-dependent diffusion coefficient, resulting in much more accurate predictions (approximately half the sum square error of the aforementioned reactor-scale model that produced good agreement for stock and CCC) for a variety of operating conditions. The amount of water vapor or relative humidity (RH) in the flow during a reactor experiment was determined to influence HCl uptake. Experiments were performed to understand the interaction of gaseous HCl with aluminum surfaces in the presence of water vapor. The results show that increasing levels of RH increased the capacity of aluminum to adsorb HCl but decreased the capacity of Nomex to uptake HCl. A series of tests were performed on individual aluminum samples after they had been saturated with a fixed concentration of HCl in dry air conditions with the goal of determining how their HCl uptake capacity changes after various treatments with water relative to the original saturation tests. HCl-saturated aluminum samples subjected to a second dry air flow at the same HCl concentration as the original test had an uptake of 23.5% of the original sample with no treatment in between. Saturated aluminum samples subjected to an air flow with a RH of 90% in between tests had an uptake of 35.6% of the original. Saturated aluminum samples submerged in distilled water for 12 hours in between tests had an uptake of 82.2% of the original sample. Previously saturated aluminum tested with HCl and a 50% RH air flow resulted in similar uptake characteristics in multiple repeated tests. The experiments show the profound effect water vapor has on HCl uptake onto aluminum surfaces. In the samples subjected to water vapor or liquid water, capillary condensation and capillary diffusion alters the transport of HCl significantly. A model was proposed that developed a relationship between RH and the coefficient of HCl diffusion in aluminum chloride. This produced an “S-shaped” curve with diffusion coefficient as a function of RH, with 45% RH represented as the point where the diffusion coefficient is halfway between no water saturation and 100% water saturation in the aluminum chloride product layer. No difference in uptake characteristics for the experiment or model were realized between 50% and 62% RH. The results from the large-scale microgravity experiment, Saffire, are discussed as they pertain to the fate of HCl throughout a spacecraft. HCl was released, both as a standalone event, and in concurrence with the burning of a structured cloth. These events only produced a small response in the far field HCl sensor, while a PMMA burn that did not produce HCl had a significantly greater response. A ground-based large-scale facility was constructed to flow acid gas at the scale and configuration realized in the Saffire experiments. A CFD model of this duct was constructed to test kinetic parameters developed in this work at a larger scale and different geometric configuration and to predict the results of the large-scale facility. The models developed in this work were used to interpret the results of the microgravity tests and lead the discussion on what further experiments and models are needed in order to predict the fate of acid gas in a spacecraft environment. To summarize, the major contributions of this work are as follows: the capacity to uptake HCl, with and without the presence of water vapor, was measured for a variety of real spacecraft surfaces. Several different models (single reactor-scale, multiscale, spacecraft-scale) were developed and with the aid of modeling, the rate of uptake for those surfaces was also predicted and validated. The kinetic parameters determined from the small-scale reactor experiments and models were used to predict large-scale and microgravity tests. Conclusions from this research will be used in the design of spacecraft vehicles and large-scale microgravity fire safety experiments. The models built by this work will aid designers in sensor placement and could be used to predict acid gas transport from fires in partial gravity, as would be seen in Lunar and Martian habitats.

fire safety↗

Noninvasive, near infrared spectroscopic-measured muscle pH and PO2 indicate tissue perfusion for cardiac surgical patients undergoing cardiopulmonary bypass

OBJECTIVE: To determine whether near infrared spectroscopic measurement of tissue pH and Po2 has sufficient accuracy to assess variation in tissue perfusion resulting from changes in blood pressure and metabolic demand during cardiopulmonary bypass. DESIGN: Prospective clinical study. SETTING: Academic medical center. SUBJECTS: Eighteen elective cardiac surgical patients. INTERVENTION: Cardiac surgery under cardiopulmonary bypass. MEASUREMENTS AND MAIN RESULTS: A near infrared spectroscopic fiber optic probe was placed over the hypothenar eminence. Reference Po2 and pH sensors were inserted in the abductor digiti minimi (V). Data were collected every 30 secs during surgery and for 6 hrs following cardiopulmonary bypass. Calibration equations developed from one third of the data were used with the remaining data to investigate sensitivity of the near infrared spectroscopic measurement to physiologic changes resulting from cardiopulmonary bypass. Near infrared spectroscopic and reference pH and Po2 measurements were compared for each subject using standard error of prediction. Near infrared spectroscopic pH and Po2 at baseline were compared with values during cardiopulmonary bypass just before rewarming commenced (hypotensive, hypothermic), after rewarming (hypotensive, normothermic) just before discontinuation of cardiopulmonary bypass, and at 6 hrs following cardiopulmonary bypass (normotensive, normothermic) using mixed-model analysis of variance. Near infrared spectroscopic pH and Po2 were well correlated with the invasive measurement of pH (R2 =.84) and Po2 (R 2 =.66) with an average standard error of prediction of 0.022 +/- 0.008 pH units and 6 +/- 3 mm Hg, respectively. The average difference between the invasive and near infrared spectroscopic measurement was near zero for both the pH and Po2 measurements. Near infrared spectroscopic Po2 significantly decreased 50% on initiation of cardiopulmonary bypass and remained depressed throughout the bypass and monitored intensive care period. Near infrared spectroscopic pH decreased significantly during cardiopulmonary bypass, decreased significantly during rewarming, and remained depressed 6 hrs after cardiopulmonary bypass. Diabetic patients responded differently than nondiabetic subjects to cardiopulmonary bypass, with lower muscle pH values (p =.02). CONCLUSIONS: Near infrared spectroscopic-measured muscle pH and Po2 are sensitive to changes in tissue perfusion during cardiopulmonary bypass.

Non-NASA Center↗