Search NASA⌕ Search

SEARCH · Search NASA

Results for “ICSBEP”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Identification of Integral Benchmarks for Nuclear Data Testing Using DICE (Database for the International Handbook of Evaluated Criticality Safety Benchmark Experiments)

Typical users of the International Criticality Safety Evaluation Project (ICSBEP) Handbook have specific criteria to which they desire to find matching experiments. Depending on the application, those criteria may consist of any combination of physical or chemical characteristics and/or various neutronic parameters. The ICSBEP Handbook contains a structured format helping the user narrow the search for experiments of interest. However, with nearly 4300 different experimental configurations and the ever increasing addition of experimental data, the necessity to perform multiple criteria searches have rendered these features insufficient. As a result, a relational database was created with information extracted from the ICSBEP Handbook. A users’ interface was designed by OECD and DOE to allow the interrogation of this database. The database and the corresponding users’ interface are referred to as DICE. DICE currently offers the capability to perform multiple criteria searches that go beyond simple fuel, physical form and spectra and includes expanded general information, fuel form, moderator/coolant, neutron-absorbing material, cladding, reflector, separator, geometry, benchmark results, spectra, and neutron balance parameters. DICE also includes the capability to display graphical representations of neutron spectra, detailed neutron balance, sensitivity coefficients for capture, fission, elastic scattering, inelastic scattering, nu-bar and mu-bar, as well as several other features.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Educating Next Generation Nuclear Criticality Safety Engineers at the Idaho National Laboratory

One of the challenges in educating our next generation of nuclear safety engineers is the limitation of opportunities to receive significant experience or hands-on training prior to graduation. Such training is generally restricted to on-the-job-training before this new engineering workforce can adequately provide assessment of nuclear systems and establish safety guidelines. Participation in the International Criticality Safety Benchmark Evaluation Project (ICSBEP) and the International Reactor Physics Experiment Evaluation Project (IRPhEP) can provide students and young professionals the opportunity to gain experience and enhance critical engineering skills. The ICSBEP and IRPhEP publish annual handbooks that contain evaluations of experiments along with summarized experimental data and peer-reviewed benchmark specifications to support the validation of neutronics codes, nuclear cross-section data, and the validation of reactor designs. Participation in the benchmark process not only benefits those who use these Handbooks within the international community, but provides the individual with opportunities for professional development, networking with an international community of experts, and valuable experience to be used in future employment. Traditionally students have participated in benchmarking activities via internships at national laboratories, universities, or companies involved with the ICSBEP and IRPhEP programs. Additional programs have been developed to facilitate the nuclear education of students while participating in the benchmark projects. These programs include coordination with the Center for Space Nuclear Research (CSNR) Next Degree Program, the Collaboration with the Department of Energy Idaho Operations Office to train nuclear and criticality safety engineers, and student evaluations as the basis for their master's thesis in nuclear engineering.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Finalizing the 63 Cu and 65 Cu Resonance Evaluations for the ENDF/B-VIII Release

The resolved resonance region evaluation for the only two natural isotopes of copper ( 63 Cu and 65 Cu) was carried out at the Oak Ridge National Laboratory (ORNL) in support of the US Department of Energy (DOE) Nuclear Criticality Safety Program (NCSP). The particular interest in the isotope of copper arose because it was linked with poor performance of the Zeus series of integral benchmarks from the International Criticality Safety Benchmark Evaluation Project (ICSBEP). Good agreement between the calculated and experimentally measured values for the ICSBEP benchmarks is essential to the NCSP because the ICSBEP benchmarks are used for validation purposes of criticality safety calculations.

07 ISOTOPE AND RADIATION SOURCES↗

Jemima Plate Characterization

The HEU Jemima plates have been utilized in numerous International Criticality Safety Benchmark Evaluation Project (ICSBEP) evaluations. ICSBEP evaluations are a vital com ponent of nuclear data validation for applications across the nuclear community. In the past, different combinations of mass, caliper measurements, and drawing dimensions have been used to define the HEU Jemima plates in ICSBEP evaluations. Some of these combinations result in large density ranges (17 g/cm 3 to 19 g/cm 3 ) or unrealistic densities (greater than 19 g/cm 3 ). Additionally, oxidation of the plates has led to questioning the flatness of each plate, which can add additional gaps in experiment configurations. This work proposes a standardized method of defining the commonly used HEU Jemima plates across different experiments.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Two Delayed Critical 7-Inch-Diameter Interacting Enriched (93.14) Uranium Metal Cylinders without Moderator and Reflector

This report documents very accurately the configuration and the materials for experiments with two unmoderated, unreflected, interacting, coaxial, highly enriched, 7-in.-diameter, uranium metal cylinders performed at the Oak Ridge Critical Experiments Facility (ORCEF) in April 1963 and described in logbook E-19 associated with experiments in the East cell of ORCEF. The information is sufficiently accurate that it can be used as the basis for preparation of benchmarks for International Criticality Safety Benchmark Program (ICSBEP) at Idaho National laboratory. The thickness of the cylinders was varied and the spacing between them was adjusted to achieve a delayed critical configuration. The average enrichment of the uranium metal was 94.15 wt. % 235 U. The heights of the 7-in.-diameter, equal-height cylinders varied from 2 5/8 to 3 1/4 inches. All interacting cylinders were assembled coaxially with their flat faces parallel and their combined masses varied between 62 and 76 kilograms of HEU metal. The data from these six experiments described are judged to be acceptable for use as criticality safety benchmark experiments for the ICSBEP and EURATOM’s Nuclear Energy Agency nuclear criticality safety benchmark program, once the uncertainty analysis is completed. Based on previous ICSBEP benchmarks with this enriched uranium metal at ORCEF, it is expected that the uncertainties in k eff could be as low as ± 0.0002.

07 ISOTOPE AND RADIATION SOURCES↗

Critical and Subcritical Experiment NEA Benchmark Possibilities for Measurements at ORCEF and Other USDOE Facilities

This report documents a wide variety of critical and subcritical measurements that could be Nuclear Energy Agency (NEA) or International Criticality Safety Benchmark Program (ICSBEP) benchmarks. The list has omitted some few measurements. The experiments are divided into four classes: critical experiments only, critical and subsequent subcritical experiments, subcritical experiments (all performed in critical experiment facilities, and fourth subcritical measurements performed in Material Balance Areas at the Y-12 National Security Complex (NSC) for Y-12 nuclear criticality safety. This report documents to number of critical facility days utilized used for the measurements. Measurement at critical and subsequently subcritical in critical facilities at Oak Ridge National Laboratory (ORCEF), Los Alamos National Laboratory, Pacific Northwest National Laboratory, and Babcock and Wilcox at Lynchburg, Va, utilized ~350 operational days of critical facility time, Measurement only at subcritical at ORCEF utilized ~200 operational days in this critical facility, and subcritical measurements in Material Balance Areas of the Y-12 National Security Complex used 350 operational days, many were unattended measurements. In view of the high cost of critical facility time and the limitation of only one facility available for measurements in the United States, it is very cost-effective to mine the existing data to produce benchmarks such as those already in NEA and ICSBEP. For measurements at ORCEF the material descriptions from Y-12 NSC and the accuracy of the configurations should (bases on experience with existing NEA or ICSBEP of ORCEF measurement benchmarks) result in uncertainties in measured k eff values lower than ±0.001 and may be as low as ±0.0002; thus, allowing more accurate comparisons between measurements and calculations and thus more accurate verification of calculations.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Two Delayed Critical 15-Inch-Diameter Interacting Enriched (93.14) Uranium Metal Cylinders without Moderator and Reflector

This report documents very accurately the configuration and the materials for experiments with two unmoderated, unreflected, interacting, coaxial, highly enriched, 15-in.-diameter, uranium metal cylinders performed at the Oak Ridge Critical Experiments Facility (ORCEF) in May to Aug 1963 and described in logbook E-19 and E -20 associated with experiments in the East cell of ORCEF. Measurements were also performed in April and May of 1965 and described in logbooks E-22 and E-23 The information is sufficiently accurate that it can be used as the basis for preparation of benchmarks for International Criticality Safety Benchmark Program (ICSBEP) at Idaho National laboratory. The thickness of the cylinders was varied and the spacing between them was adjusted to achieve a delayed critical configuration. The average enrichment of the uranium metal was 94.14 wt. % 235 U. The heights of the 15-in.-diameter, equal-height cylinders varied from 1-5/8 to 3.0-inches. All interacting cylinders were assembled coaxially with their flat faces parallel and their combined masses varied between 182 and 325 kilograms of HEU metal. The data from these 12 experiments described would be acceptable for use as criticality safety benchmark experiments for the ICSBEP and EURATOM’s Nuclear Energy Agency nuclear criticality safety benchmark program, once the uncertainty analysis is completed. Based on previous ICSBEP benchmarks with this enriched uranium metal at ORCEF, it is expected that the uncertainties in k eff could be as low as ± 0.0002.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Three Delayed Critical 15-Inch-Diameter Interacting Enriched (93.14) Uranium Metal Cylinders Without Moderator and Reflector

This report documents very accurately the configuration and the materials for experiments with three unmoderated, unreflected, interacting, coaxial, highly enriched, 15-in.-diameter, uranium metal cylinders performed at the Oak Ridge Critical Experiments Facility (ORCEF) in August and September 1963 and described in logbook E 20 associated with experiments in the East cell of ORCEF. The information is sufficiently accurate that it can be used as the basis for preparation of benchmarks for International Criticality Safety Benchmark Program (ICSBEP) at Idaho National laboratory. The thickness of the cylinders was varied and the spacing between them was adjusted to achieve a delayed critical configuration. The average enrichment of the uranium metal was 94.14 wt. % 235U. The heights of the 15-in.-diameter, equal-height cylinders varied from 1-1/8to 2.00 inches. All interacting cylinders were assembled coaxially with their flat faces parallel and their combined masses varied between 182 and 325 kilograms of HEU metal. The data from these six experiments described are judged to be acceptable for use as criticality safety benchmark experiments for the ICSBEP and EURATOM’s Nuclear Energy Agency nuclear criticality safety benchmark program, once the uncertainty analysis is completed. Based on previous ICSBEP benchmarks with this enriched uranium metal at ORCEF, it is expected that the uncertainties in measured keff could be as low as ± 0.0002.

36 MATERIALS SCIENCE↗

Uranium–Molybdenum Alloy Critical Experiments for the Design of the Health Physics Research Reactor

Clean critical experiments with a uranium-molybdenum alloy (average of 10.1616 wt. % Mo with a density of 17.08 g/cm 3 ) were performed at the Oak Ridge Critical Experiments Facility in 1961 to support the design of the Health Physics Research Reactor (HPRR). The HPRR was similar to the Godiva burst reactor at Los Alamos National Laboratory and was designed to produce 50 microseconds burst of 10 17 fission pulses of radiation for dosimetry measurements, initially in support of the determination of the doses from the nuclear detonations in Japan during World War II. These experiments reported here were used to verify the calculational methods used to design the HPRR. These delayed critical measurements were:1) a solid unreflected and unmoderated 8-in.-dimeter U-Mo cylinder, 2) an unmoderated and unreflected annulus with 8-in.-outside diameter, 2-in.-inside diameter cylinder with a central void, 3) an unmoderated and unreflected annulus with 8-in.-outside diameter, 2-in.-inside diameter cylinder with a central void filled with stainless steel, 4) Same as 3) but with 3-in-thick Plexiglas reflector on top with and without cadmium between the reflector and the U-Mo alloy assembly with steel in the center, and 5) an unmoderated and unreflected annulus which was a modification of the second but with the lower 5 inches of the central hole enlarged to 3.5 in. with various reflector conditions. The reflector conditions were: 1-in.-thick Plexiglas on all outer surfaces-void in the center; 1-in.-thick Plexiglas on all outer surfaces-Plexiglas in the center; 2-in.- thick Plexiglas on radial surface-void in the center; 6-in.-thick Plexiglas on the bottom only-Plexiglas in the center; and 6-in.-thick Plexiglas on bottom, 1-in.-thick on top and on the lower 8.25-cm.-section of the radial surface-void in the center. For some of these reflector conditions 0.025-cm.thick cadmium was located between the reflector and the U-Mo alloy. The uranium contained 93.17 wt. % 235 U. Reflection was a safety concern for this unmoderated and unreflected reactor and reduction of reflection effects was also investigated by insertion of neutron absorber around the U-Mo alloy. The stainless steel 304 contained 18% nickel and 8% chromium and the rest iron. The reflector material was a methacrylate plastic (Plexiglas) containing 5.8 x 10 22 atoms/cm 3 of hydrogen and 3.6 x 10 22 atoms/cm 3 of carbon with a density of 1.20 g/cm 3 . The purpose of this report is to document the experimental information for the measurements performed so that at a later date researchers could perform the required uncertainty and calculational analyses and documentation to use these data for an International Nuclear Criticality Safety Benchmark Program (ICSBEP) or a EURATON Nuclear Energy Agency (NEA) benchmark. The data from the experiments described should be acceptable for use as criticality safety benchmark experiments for the ICSBEP and the NEA nuclear criticality safety benchmark program, once the uncertainty analysis is completed. Based on previous ICSBEP benchmarks with this enriched uranium metal at ORCEF, the uncertainties in k eff could be as low as ±0.0002 for some configurations.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Delayed Critical Highly Enriched Uranium Metal Cylinders with Thin Graphite Top and Bottom Reflectors

Nine 7, 11, and 15 in. diam highly enriched uranium (HEU, 93.15 wt % 235 U) metal cylinders were assembled on the vertical assembly machine in the Oak Ridge Critical Experiments Facility (ORCEF) and had 1, 2, or 3 in. thick HLM graphite reflectors on the top and bottom. The experiments, which were performed between April 3, 1970, and February 18, 1971, used 23 operational days at ORCEF. Before those experiments were carried out, unreflected and unmoderated, graphite- and polyethylene-reflected, and polyethylene-moderated HEU metal cylinders had been assembled to obtain delayed criticality at ORCEF in the 1960s and reported by the International Criticality Safety Benchmark Evaluation Project (ICSBEP) at the Nuclear Energy Agency (NEA)*. The data from the nine critical experiments are acceptable for use as criticality safety benchmark experiments for the NEA’s ICSBEP once the uncertainty analysis is completed. Based on previous ICSBEP benchmarks with HEU metal at ORCEF, the uncertainties in k eff are expected to be as low as ±0.0004.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Final Design for Thermal/Epithermal eXperiments (TEX) with Lithium Absorbers to Provide Validation Benchmarks for Y-12 Electrorefining Facility

One of the main goals of the Thermal/Epithermal eXperiments (TEX) project is to use existing Nuclear Criticality Safety Program (NCSP) assets to create critical experiment plutonium and uranium test beds for materials important to criticality safety that have insufficient benchmark evaluations. The plutonium test bed experiments were completed in 2018 and are published in the 2020 edition of the International Criticality Safety Benchmark Evaluation Project (ICSBEP) Handbook. The uranium test bed assemblies were completed in 2023 and accepted in the 2024 edition of the ICSBEP Handbook. The Nuclear Criticality Safety (NCS) group at Y-12 National Security Complex has identified programmatic need for validation cases for uranium electrorefining operations at Y-12. The electrorefining operation credits lithium enriched in 6 Li in addition to 35 Cl as absorbers in the design criticality safety evaluation for precluding criticality under upset conditions in the large and geometrically unfavorable electro-refiner. There is, however, inadequate experimental validation for the 6 Li absorbers. As an extension of the TEX uranium test bed, TEX-Cl critical experiments were performed with sodium chloride salt to address the 35 Cl thermal absorption as well as other validation needs at Los Alamos National Laboratory (LANL). These experiments were completed in 2024 and accepted into the 2025 ICSBEP Handbook. To continue the methodology used in TEX-Cl, TEX-Li aims to accomplish the same. The overall design of both experiments was to use commercially available, high purity, salts with polyethylene moderator and HEU plates to configure a critical assembly. Three experiments are planned for TEX-Li using encapsulated lithium carbonate (Li 2 CO 3 ), with natural 6 Li abundance. For all experiments, the highly enriched uranium (HEU) Jemima plates will be used as fissile material. Multiple layers will be stacked together with encapsulated Li 2 CO 3 alternated with polyethylene in standard configurations. Standard stacking was found to be optimal in matching the different sensitivity profiles provided by the Y-12 models. Three configurations are proposed with varying polyethylene moderation and a constant 1/4” absorber thickness. The first uses 11 layers of 5/4” polyethylene, the second uses 9 layers of 3/4” polyethylene, and the third uses 10 layers of 1/2” polyethylene. Calculations showed that some alternative forms of lithium-based materials provided slightly less-optimal sensitivity profiles when compared to lithium carbonate but come with other drawbacks. These alternatives included lithium aluminate (LiAlO 2 ), Aluminum-2050 alloy, Aluminum-8090, Aluminum-2095, lithium hydride (LiH), and lithium fluoride (LiF). Lithium aluminate and aluminum-2050 provided comparable sensitivity profiles when compared to lithium carbonate and can be used instead if lithium carbonate cannot be readily procured. After a broad material study, lithium carbonate outperformed any alternative material with a balance in affordability and workability. The assessment of experimental uncertainties of the non-absorber and absorber components was predicted to be 0.00089 and 0.00093 Δk eff , respectively. The largest uncertainties may be reduced with precision dimensional inspection of the components. Many of the parts and equipment for IER 575 have already been fabricated or procured for previous projects and therefore do not contribute significantly to the overall cost of this experiment. This includes the Jemima plates and Comet critical assembly machine, which are existing NCSP assets, as well as the aluminum platen and polyethylene reflector rings, which were fabricated and authorized for the TEX experiment involving HEU with polyethylene. Lithium carbonate containers will be procured by LANL and will be filled by LLNL. The total material costs for TEX-Li experiments are estimated to be on the order of $\$$47,400. Precision inspection, including dimensional, mass, density, and impurity, is recommended for all components for an estimated cost of $\$$12,000.

35Cl↗

Evaluation of a Potassium Filled UO2 Core in a Beryllium- ??eflected Space Reactor

The critical configuration of the small, compact critical assembly (SCCA) experiments performed at the Oak Ridge Critical Experiments Facility (ORCEF) in 1962-1965[1,2] have been evaluated for the International Criticality Safety Benchmark Evaluation Project (ICSBEP) and were determined to be acceptable benchmark experiments and are included in the International Handbook of Evaluated Criticality Safety Benchmark Experiments (ICSBEP Handbook)[3]. The initial intent of these experiments was to support the design of the Medium Power Reactor Experiment (MPRE) program, whose purpose was to study “power plants for the production of electrical power in space vehicles.”[4] The third configuration in this series of experiments was a beryllium-reflected mockup of a stainless-steel-clad, highly enriched uranium (HEU)-O2 fuel, potassium-cooled, space power reactor. Reactivity measurements, cadmium ratio spectral measurements, and fission rate measurements were measured through the core and top reflector. Fuel effect worth measurements and neutron moderating and absorbing material worths were also measured in the assembly fuel region. The cadmium ratios, fission rate, and worth measurements were evaluated for the International Reactor Physics Experiment Evaluation Project (IRPhEP) and are published in the International Handbook of Evaluated Reactor Physics Benchmark Experiments (IRPhEP Handbook)[5]. More recently, two additional critical configurations have been evaluated and added to the existing evaluation report in the ICSBEP Handbook. The new critical configurations measure the effect of filling the core with potassium. The critical configuration consisted of 30.48 cm tall fuel tubes of 93.15 wt.% enriched uranium dioxide (UO2) pellets. Each fuel tube had 26 pellets with a total mass of 295.8 g UO2 per tube. There were 253 tubes were arranged with 1.506-cm center-to-center, triangular spacing and surrounded on all side by a beryllium reflected. The reactivity of the system was measured with the core tank empty and filled with potassium. The system reactivity was increased from 13.4 ¢ to 32 ¢. This change in system reactivity represents the worth of the potassium. Simple benchmark models for the empty and potassium filled cores have been derived and evaluated and found to be acceptable as benchmark experiments. The benchmark experiment eigenvalues are 1.0001 ± 0.0008 and 1.0011 ± 0.0009 for the empty and filled cores, respectively. When calculated with MCNP5 and ENDF/B-VII.0 the calculated eigenvalues are 0.98906 ± 0.00002 and 0.98883 ± 0.00002, respectively. These results are concerning due to the drop of the calculated system reactivity when potassium is added to the system rather than the expected increase in system reactivity.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

The experiment filtering tool in the MACSENS workbench - 14341

The MACSENS (outils Moret d'Aide a la Caracterisation et aux etudes de SENSibilite) workbench is dedicated to the advanced validation work for criticality studies. The aim of this kind of tool is to determine the experiments from a validation database being the 'closest' to an application case and, from there, to evaluate a calculation bias with a related uncertainty. To achieve this goal, the MACSENS workbench relies on different kind of information stored in various databases depending on the origin of the data. Two main kinds of data can be identified. The first one concerns the data used to describe the experiments of the validation database (e.g. the inputs needed to perform a calculation). These values characterize the chemical and geometrical models. They can be considered as constant, as they do not vary once evaluated, and some of them can be from a non-numerical nature (reflector material for example...). The second kind of data gathers the results obtained with the use of a simulation code, such as reaction rates, fluxes and leakages, sensitivities, k{sub eff}, etc. These values depend on the version of the code and are purely numerical. In the early 2000's, regarding the increasing number of experiments evaluated in the ICSBEP handbook, the OECD/NEA (Organization for Economic Co-operation and Development/Nuclear Energy Agency), under the ICSBEP (International Criticality Safety Benchmark Evaluation Project) working group direction, decided to store such information in a database and to provide a software, called DICE (Database for the International Criticality safety benchmark Evaluation project), allowing users to search easily criticality experiments of interest. Up to now, more than 4400 critical or subcritical configurations have been compiled by ICSBEP, described and stored in the DICE database. Over time, a validation work has been done on the data, with the participation of IRSN, and a quality assurance policy has been defined. For these reasons, the DICE database is highly reliable. These features were fundamental for the MACSENS developers, who were looking for a database containing descriptive data of the experiments included in the MORET code validation database. The paper describes the solution chosen by IRSN to take advantage of the DICE database content and to overcome the DICE limits. It also explains the quality assurance policy applied to guaranty the reliability of the stored data. It will also discuss the use of the experiment-filtering module of the MACSENS workbench to select a set of experiments and to examine numerical parameter trends for an application case. (authors)

42 ENGINEERING↗

Evaluation of a potassium filled UO{sub 2} core in a beryllium-reflected space reactor - 14371

The critical configuration of the small, compact critical assembly (SCCA) experiments performed at the Oak Ridge Critical Experiments Facility (ORCEF) in 1962-1965[1,2] have been evaluated for the International Criticality Safety Benchmark Evaluation Project (ICSBEP) and were determined to be acceptable benchmark experiments and are included in the International Handbook of Evaluated Criticality Safety Benchmark Experiments (ICSBEP Handbook)[3]. The initial intent of these experiments was to support the design of the Medium Power Reactor Experiment (MPRE) program, whose purpose was to study 'power plants for the production of electrical power in space vehicles'.[4] The third configuration in this series of experiments was a beryllium-reflected mockup of a stainless-steel-clad, highly enriched uranium (HEU)-O{sub 2} fuel, potassium-cooled, space power reactor. Reactivity measurements, cadmium ratio spectral measurements, and fission rate measurements were measured through the core and top reflector. Fuel effect worth measurements and neutron moderating and absorbing material worths were also measured in the assembly fuel region. The cadmium ratios, fission rate, and worth measurements were evaluated for the International Reactor Physics Experiment Evaluation Project (IRPhEP) and are published in the International Handbook of Evaluated Reactor Physics Benchmark Experiments (IRPhEP Handbook)[5]. More recently, two additional critical configurations have been evaluated and added to the existing evaluation report in the ICSBEP Handbook. The new critical configurations measure the effect of filling the core with potassium. The critical configuration consisted of 30.48 cm tall fuel tubes of 93.15 wt.% enriched uranium dioxide (UO{sub 2}) pellets. Each fuel tube had 26 pellets with a total mass of 295.8 g UO{sub 2} per tube. There were 253 tubes were arranged with 1.506-cm center-to-center, triangular spacing and surrounded on all side by a beryllium reflected. The reactivity of the system was measured with the core tank empty and filled with potassium. The system reactivity was increased from 13.4 c to 32 c. This change in system reactivity represents the worth of the potassium. Simple benchmark models for the empty and potassium filled cores have been derived and evaluated and found to be acceptable as benchmark experiments. The benchmark experiment eigenvalues are 1.0001 ± 0.0008 and 1.0011 ± 0.0009 for the empty and filled cores, respectively. When calculated with MCNP5 and ENDF/B-VII.0 the calculated eigenvalues are 0.98906 ± 0.00002 and 0.98883 ± 0.00002, respectively. These results are concerning due to the drop of the calculated system reactivity when potassium is added to the system rather than the expected increase in system reactivity. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Applications of Integral Benchmark Data

The International Reactor Physics Experiment Evaluation Project (IRPhEP) and the International Criticality Safety Benchmark Evaluation Project (ICSBEP) provide evaluated integral benchmark data that may be used for validation of reactor physics / nuclear criticality safety analytical methods and data, nuclear data testing, advanced modeling and simulation, and safety analysis licensing activities. The handbooks produced by these programs are used in over 30 countries. Five example applications are presented in this paper: (1) Use of IRPhEP Data in Uncertainty Analyses and Cross Section Adjustment, (2) Uncertainty Evaluation Methods for Reactor Core Design at JAEA Using Reactor Physics Experimental Data, (3) Application of Benchmarking Data to a Broad Range of Criticality Safety Problems, (4) Cross Section Data Testing with ICSBEP Benchmarks, and (5) Use of the International Handbook of Evaluated Reactor Physics Benchmark Experiments to Support the Power Industry.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Validation of MCNP Critical Benchmark Models of Moderated Highly Enriched Uranium Slabs

A new centralized repository of high-quality MCNP models of critical benchmark experiments is currently under development at Los Alamos National Laboratory (LANL). The benchmark experiments are described in the International Criticality Safety Benchmark Evaluation Project (ICSBEP) Handbook, and the initial set of benchmark models are derived from the Whisper Suite provided with MCNP6.2. This effort is a collaboration among the Nuclear Criticality Safety, Nuclear Data, and Monte Carlo code development/application organizations at LANL. The goal is to build a single LANL benchmark collection that is up to date with the latest ICSBEP revision, has a formal review and revision process, is contained in an open-source repository, and utilizes new Python tools for improved input and output file review. This paper describes the validation of the models associated with HEU-MET-FAST-007, “Uranium Metal Slabs Moderated with Polyethylene, Plexiglas, and Teflon”. The Monte Carlo n-Particle (MCNP) models were compared to the second revision of HEU-MET-FAST-007. The experiment considered critical configurations of highly enriched uranium (HEU) metal slabs and various moderators in 43 unique cases. The slabs of uranium were separated by layers of moderating material, forming an assembly. The assembly was separated in two halves with one half placed on a stationary table and the other attached to a moveable table that could be raised and lowered via pulleys connected to the ceiling of the shielded room. To reach criticality, the two halves were brought together with a negligible gap between the assemblies.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Application of the Rossi-alpha method to simulations of HEU and organic scintillators

The International Criticality Safety Benchmark Evaluation Project (ICSBEP) Handbook contains thousands of high-quality benchmark measurements that include detailed descriptions of experiment designs and exhaustive accounting of uncertainties. These benchmarks are used extensively by the criticality safety and nuclear data communities. A subcritical benchmark involving bare, highly enriched uranium (HEU) has yet to be accepted to the handbook. The Measurement of Uranium Subcritical and Critical (MUSiC) was proposed to address this gap. MUSiC will be performed at the National Criticality Experiments Research Center (NCERC) and will leverage bare HEU hemisphere shells that can be assembled in a variety of configurations. The measurement has the following key benefits: it will be the first set of fast, subcritical measurements of HEU to be submitted to ICSBEP; ten configurations will be measured spanning from nearly no multiplication to critical (e.g., it is a measurement of similar systems with different re activities); measurements of an all-HEU system will be of value for nuclear data validation, providing results that assist in determining biases in both measurements and simulations. A variety of detector systems will be used including a Neutron Multiplicity Array Detector (NoMAD) system (similar to the MC-15), four small volume 0.635 cm (#8960;) × 7.59 cm 3He detectors (ideal for measuring prompt neutron decay constants due to their fast recovery speed), and an array of eight 5.08 cm (#8960;) × 5.08 cm EJ-309 organic scintillator detectors. The focus of this work is the simulation of the subcritical MUSiC configurations including the EJ-309 detectors and the application of the Rossi-α method. The EJ-309 organic scintillator detector array is a new detection system that will be deployed at NCERC. Organic scintillators are ideal for measurements of fast, subcritical systems due to their short time response on the order of nanoseconds.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Evaluation of Oak Ridge National Laboratory Health Physics Research Reactor Operation Data for Critical Benchmark Creation

The Oak Ridge National Laboratory (ORNL) Health Physics Research Reactor (HPRR) was a research reactor designed and built at ORNL in 1961. The critical assembly used a highly enriched uranium and molybdenum alloy as the fuel and could be operated in steady-state or burst modes. The HPRR has recently been the object of an investigation to create a criticality benchmark. Such benchmarks are very important, as they are used primarily to show the accuracy of newly developed modeling codes and to help experimental validation and reactor licensing. The evaluated experiments considered in this paper were carried out between 1974 and 1986 from various HPRR activities such as steady-state subcritical, steady-state critical, and burst prompt super-critical operations of the reactor for dosimetry, irradiation, or training purposes. By using the HPRR experimental logbook information and the as-built drawings of the critical assembly, a highly detailed model of the HPRR was created with SCALE 6.2.4/KENO-VI, and a first version of a critical benchmark of the HPRR was developed following the International Criticality Safety Benchmark Evaluation Project (ICSBEP) guidelines for thorough description and uncertainty/sensitivity quantification. Unfortunately, in most of the evaluated experiments, the obtained difference between calculated and experimental k eff is around 1,000 pcm, corresponding to a relative error of approximately 1%, beyond the quality standards of the ICSBEP recommending a relative error below 0.1%. Moreover, the derived experimental uncertainty is high, around 4% relative, mainly due to the U-Mo fuel density uncertainty, but also from numerous other factors. For these reasons, the creation of a valuable critical benchmark from HPRR operation data is thus far compromised. In this paper, the different steps of the experiments’ evaluation are summarized, and the reasons for the experimental/calculation discrepancies and potential ways to solve them are explored. This paper also aims to remind us always to exercise considerable care when performing experimental work, and to record all the data possible for potential future uses.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗