Search NASA⌕ Search

SEARCH · Search NASA

Results for “IMAGE CONVERTER”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Neutron radiographic viewing system

The design, development and application of a neutron radiographic viewing system for use in nondestructive testing applications is considered. The system consists of a SEC vidicon camera, neutron image intensifier system, disc recorder, and TV readout. Neutron bombardment of the subject is recorded by an image converter and passed through an optical system into the SEC vidicon. The vidicon output may be stored, or processed for visual readout.

Source record↗

A magnetically focused image tube employing an opaque photocathode

Image converter has been developed which uses opaque photocathode for improved efficiency. Device is easier to fabricate than previous semi-transparent photocathode converters and uses compounds from Groups 3-5 that are responsive to wave-lengths between ultraviolet (approximately 100 nm) and near infrared region (approximately 1000 nm).

Johnson, C. B.↗

Hologram recording tubes

Optical memories allow extremely large numbers of bits to be stored and recalled in a matter of microseconds. Two recording tubes, similar to conventional image-converting tubes, but having a soft-glass surface on which hologram is recorded, do not degrade under repeated hologram read/write cycles.

Rajchman, J. H.↗

Laser ranging system with 1-cm resolution.

A laser ranging system has been developed in which an image converter tube equipped with deflection plates is used to make a precise measurement of the fractional amount by which the time of flight of the ranging pulse exceeds an integral multiple N of the period of a stable oscillator. The value of N is determined in an auxiliary measurement. In short-range tests with a laboratory breadboard version of the system, time-of-flight uncertainties of about 45 psec were observed. The corresponding uncertainty in a range measurement is smaller than 7 mm.

Golden, K. E.↗

Streak camera time calibration procedures

Time calibration procedures for streak cameras utilizing a modulated laser beam are described. The time calibration determines a writing rate accuracy of 0.15% with a rotating mirror camera and 0.3% with an image converter camera.

Long, J.↗

Applications of HCMM satellite data to the study of urban heating patterns

A research summary is presented and is divided into two major areas, one developmental and the other basic science. In the first three sub-categories are discussed: image processing techniques, especially the method whereby surface temperature image are converted to images of surface energy budget, moisture availability and thermal inertia; model development; and model verification. Basic science includes the use of a method to further the understanding of the urban heat island and anthropogenic modification of the surface heating, evaporation over vegetated surfaces, and the effect of surface heat flux on plume spread.

Carlson, T. N.↗

Plasma ignition for laser propulsion

For a specific optical system a pulsed carbon dioxide laser having an energy output of up to 15 joules was used to initiate a plasma in air at one atmosphere pressure. The spatial and temporal development of the plasma were measured using a multiframe image converter camera. In addition the time dependent velocity of the laser supported plasma front which moves opposite to the direction of the laser pulse was measured in order to characterize the type of wavefront developed. Reliable and reproducible spark initiation was achieved. The lifetime of the highly dense plasma at the initial focal spot was determined to be less than 100 nanoseconds. The plasma front propagates toward the laser at a variable speed ranging from zero to 1.6 x 1,000,000 m/sec. The plasma front propagates for a total distance of approximately five centimeters for the energy and laser pulse shape employed.

Askew, R. F.↗

An instrument for rapidly measuring plasma distribution functions with high resolution

An instrument which can rapidly measure plasma particle distribution functions has been developed based upon recent innovations in electrostatic analyzer design and position sensitive particle detection. The new analyzer uses a quadrispherical geometry, but has a completely uniform 360 deg fan-shaped field of view. The polar angular distribution of entering particles is spatially imaged onto a position sensitive detector at the annular exit aperture after a deflection through 90 deg. Several methods of position sensitive detection have been successfully used in conjunction with this analyzer. The simplest is individual channel multipliers spaced around the annular exit. Microchannel plate electron multipliers permit greater position resolution to be obtained, and a detector using microchannel plates followed by a resistive anode image converter obtains angular resolution of about one degree, i.e., 360 individual angle pixels. Instruments of this type were flown on a sounding rocket in early 1982 and will be included on the Giotto comet mission and the AMPTE ion release module (IRM).

Carlson, C. W.↗

An experimental investigation of electric flashover across solid insulators in vacuum

The insulation of high voltage conductors often employs solid insulators for many applications. In such applications, an unexpected electric flashover may occur along the insulator surface. Under conditions of high vacuum, the flashover voltage across the insulator is observed to be lower compared with that of the same electrode separation without an insulator. The reason for such an extreme reduction of flashover voltage is not well understood. Several models based on the secondary electron emission, were proposed to explain the onset of the surface flashover. The starting point and the developing velocity of the surface flashover were determined. An intensified image converter camera was used to observe the initial stage of electrical flashover along the insulator surface parallel to the electric field. Several different insulator materials were used as test pieces to determine the effect of the dielectric constant on the flashover voltage characteristics.

Vonbaeyer, H. C.↗

Stagnation-point ablation of carbonaceous flat disks. II Experiment

Six flat-disk models made of carbon-carbon and carbon-phenolic materials were launched in an argon-filled track-range facility to test ablation characteristics in a radiation-dominated, massive-blowing environment. The shock standoff distances deduced from the shadowgraphs agree with theoretical predictions during the earlier portion of the flight, while the wall temperatures determined by the image-converter photographs agree with predictions during the later portion. The measured surface recessions exceed the calculated values by about 60 percent for carbon-phenolic and 30 percent for carbon-carbon. The discrepancies are attributed to spallation. The measured char thicknesses agree with theoretical predictions.

Park, C.↗

Orographic Disturbances of Upper Atmosphere Emissions

There are some increases of the temperature of the hydroxyl emission (delta T approximately 20 K, z approximately 90 km) and of the intensity of the 63000 oxygen emission (delta I/I approximately 20 per cent, z approximately 250 km) for the lee of the mountains at distances about 150 km in the case of the latitudinal direction of the wind (U approximately 10 m/s) at the 3000 m level. Airflow motions over mountains may be one of the possible processes of generation of wave disturbances penetrating into the upper atmospheres (HINES, 1974; LINDZEN, 1971). The purpose here is to study the penetration of orographic disturbances into upper atmosphere. Airplane measurements of emission variations of hydroxyl and atomic oxygen 6300 A near the Northern Ural mountains were made. Several nocturnal flights were carried out in March, 1980 and January to February, 1981 at heights about 3000 m along 64 deg northern latitude in the Ural region. Spectrographs SP-48 with electronic image converters registration for OH ((9,4) and (5,1) bands - 7700 to 8100 A) and OI (6300 A) emissions were used. The zenith region was observed, and exposure time was 2 minutes. This corresponds to averaging of the emission intensities along the airplane trace over a distance of 10 km. Simultaneous measurements of atmospheric temperature variations at the flight altitude were made.

Shefov, N. N.↗

Shock induced radiation from minerals

Schmitt and Ahrens (1983) have concluded that the type of optical emission produced during shock compression was dependent upon phase changes taking place during shock compression. The present study is concerned with new observations of shock-induced optical radiation from Al2O3, MgO, NaCl, KCl, x-cut and fused SiO2, and LiF at various pressures up to 75 GPa. The experimental setup used in the study is similar to that employed by Schmitt and Ahrens. An Image Converter Camera with a three-frame plug-in unit was added to take two or three exposures of the radiation field during shock wave propagation through the sample, taking into account exposure times in the range from 50 to 500 nsec. The greybody emissions observed in LiF, which undergoes no phase transition, imply that localized heating and perhaps melting occurs in this material during shock deformation.

Schmitt, D.↗

Infrared diagnosis using liquid crystal detectors

The possible uses of pulsed carbon dioxide lasers for analysis of plasmas and flows need appropriate infrared image converters. Emphasis was placed on liquid crystal detectors and their operational modes. Performance characterstics and selection criteria, such as high sensitivity, short reaction time, and high spatial resolution are discussed.

Hugenschmidt, M.↗

Breakdown characteristics of an isolated conducting object in a uniform electric field

A laboratory experiment was conducted to determine the physical processes involved in the electrical breakdown of a particular spark gap arrangement. The gap consists of an isolated conducting ellipsoid located midway between two large flat electrodes. Gradual increase of the applied electric field, E, in the gap produces corona on the ellipsoid tips followed by flashover in a leader-arc sequence. The leader phase consists of the abrupt formation of ionized channels which partially bridge the gap and then decay prior to the arc. Measurements of dE/dt and of current were made, and photographs were taken with an image converter. Experimental parameters are listed.

Grothaus, M. G.↗

A study of pulse surface flashover in a vacuum

The prebreakdown phenomenon of pulsed surface flashover across solid insulators has been observed in a vacuum using image converter photography. A very good time and space resolution has been obtained. In summary, it was found that visible light (low luminosity) is initially emitted from the cathode and the light front propagates at a constant speed of approximately 1 X 10 to the 7th power ms. This low luminous light has a banded structure corresponding to the electron hopping distance as proposed in theoretical flashover models, and the light intensity gradually increases as it travels towards the anode. The bright light starts from the anode and expands towards the cathode, bridging the gap within 0.5 ns.

Lakdawala, Vishnukumar K.↗