Search NASA⌕ Search

SEARCH · Search NASA

Results for “IMAGE TUBE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

High-dynamic-range MCP structures

We report on the development of a new high-dynamic-range two-stage Multi-Anode Microchannel Array (MAMA) imaging tube designed for improved high count rate performance at FUV and EUV wavelengths. The new two-stage MAMA tube employs two 25-mm-diameter format MCPs placed in tandem with a small gap between the plates. The front (input) MCP is designed to be a low-gain converter plate that supports an opaque photocathode and converts the detected photons to electrons, while the second (output) MCP is of higher conductivity and thus maintains the overall gain of the multiplier at high count rates. The second MCP is mounted in proximity focus with a (224 x 960)-pixel fine-fine coincidence MAMA array for high-spatial-resolution imaging studies. The applied voltage across each MCP can be controlled independently. We report on the gain and dynamic range performance characteristics of the two-stage MAMA tube in two different configurations: first, with the output MCP having moderate conductivity (about 100 MOhm); and second, with the output MCP having very high conductivity (about 2 MOhm). These results are compared and contrasted with those of the more conventional MAMA tube configuration which employs a single high-gain curved-channel MCP.

Slater, David C.↗

Development and field testing of a Light Aircraft Oil Surveillance System (LAOSS)

An experimental device consisting of a conventional TV camera with a low light level photo image tube and motor driven polarized filter arrangement was constructed to provide a remote means of discriminating the presence of oil on water surfaces. This polarized light filtering system permitted a series of successive, rapid changes between the vertical and horizontal components of reflected polarized skylight and caused the oil based substances to be more easily observed and identified as a flashing image against a relatively static water surface background. This instrument was flight tested, and the results, with targets of opportunity and more systematic test site data, indicate the potential usefulness of this airborne remote sensing instrument.

Burns, W.↗

Piezoelectrically Enhanced Photocathodes

Doping of photocathodes with materials that have large piezoelectric coefficients has been proposed as an alternative means of increasing the desired photoemission of electrons. Treating cathode materials to increase emission of electrons is called "activation" in the art. It has been common practice to activate photocathodes by depositing thin layers of suitable metals (usually, cesium). Because cesium is unstable in air, fabrication of cesiated photocathodes and devices that contain them must be performed in sealed tubes under vacuum. It is difficult and costly to perform fabrication processes in enclosed, evacuated spaces. The proposed piezoelectrically enhanced photocathodes would have electron-emission properties similar to those of cesiated photocathodes but would be stable in air, and therefore could be fabricated more easily and at lower cost. Candidate photocathodes include nitrides of elements in column III of the periodic table . especially compounds of the general formula Al(x)Ga(1.x)N (where 0< or = x < or =.1). These compounds have high piezoelectric coefficients and are suitable for obtaining response to ultraviolet light. Fabrication of a photocathode according to the proposal would include inducement of strain in cathode layers during growth of the layers on a substrate. The strain would be induced by exploiting structural mismatches among the various constituent materials of the cathode. Because of the piezoelectric effect in this material, the strain would give rise to strong electric fields that, in turn, would give rise to a high concentration of charge near the surface. Examples of devices in which piezoelectrically enhanced photocathodes could be used include microchannel plates, electron- bombarded charge-coupled devices, image tubes, and night-vision goggles. Piezoelectrically enhanced photocathode materials could also be used in making highly efficient monolithic photodetectors. Highly efficient and stable piezoelectrically enhanced, ultraviolet-sensitive photocathodes and photodetectors could be fabricated by use of novel techniques for growing piezoelectrically enhanced layers, in conjunction with thinning and dopant-selective etching techniques.

Beach, Robert A.↗

Television research

Model of solid state television camera without imaging tube and using mosaic of phototransistors

Huggins, C. T.↗

A digital multichannel photometer

Semiconductor diode image tube system as digital multichannel photometer, noting cost, weight and size advantages over photomultiplier tube array with pulse counting electronics

Beaver, E. A.↗

The selection of imaging systems for planetary photography from space vehicles.

Discussion of the selection of a type of imaging system for a specific mission which will maximize the return of scientific data while keeping development risk and cost to acceptable limits. A representative example is given which shows that the parameters of the optimizing process range from the scientific objectives through the engineering and programming constraints of the spacecraft and mission, to the characteristics of the types of systems. The selections for all planetary missions flown to date have been imaging systems using image tube cameras. Film cameras and mechanical scan cameras, however, have unique advantages which should find application in planetary exploration.

Smokler, M. I.↗

The III-V photocathode - A major detector development.

Description of new (III-V) photocathodes which show improvements in sensitivity of as much as ten to a hundred times over conventional cathodes in the near infrared and useful improvements at shorter wavelengths. The development stems from a combination of basic knowledge of the photoemission process, gained in the 1950s, and the advancing understanding of the technology of III-V materials, in the 1960s. The superior performance of these cathodes is due to the fact that the vacuum level at the surface lies below the bottom of the conduction band in the bulk of the material. Consequently, the threshold of response is set by the III-V bandgap. The bandgap (and the threshold of response) can be varied by alloying different III-V materials together. A reduction in thermionic emission is realized with these cathodes. At present no semitransparent III-V cathodes with comparably interesting performance are available. The problems hindering further improvements, as well as the problems of placing these cathodes in practical multipliers and image tubes, are discussed briefly.

Spicer, W. E.↗

The nature of the Herbig Ae- and Be-type stars associated with nebulosity.

A quantitative spectrophotometric study of the Herbig Ae and Be stars associated with nebulosity demonstrates that the majority have surface gravities appropriate to pre-main-sequence stars while the remainder have surface gravities characteristic of the zero-age main seee. This evidence, along with their gross spectroscopic and pc similarity to T Tauri-like stars and the fact that all these stars appear to be surrounded by circumstellar dust, places them among the youngest known stellar objects. The geometry of the circumstellar shells is discussed and the evidence seems to favor a nonspherical, possibly disklike shape. Finally, photographs taken with a 1-micron image-tube system reveal a large number of red stellar objects surrounding many of these stars. This suggests that the Herbig Ae and Be objects may be the brightest representatives of very recently formed stellar groups.-

Strom, S. E.↗

Comparison of two sensors for outer planet mission onboard navigation.

Onboard instruments have been shown to be an effective aid to navigation on missions to the outer planets. The relationship of two possible candidate navigation instruments, an image tube (television) and a scanning photometer, with other systems such as data processing and attitude control is discussed. Certain key problem areas relating to the design of each sensor are considered, and the scientific uses of each sensor are examined. The navigational efficacy of both instruments is illustrated by some selected results from a navigation and guidance simulation of outer planet missions. It is concluded that both devices are viable alternatives for onboard outer planet navigation.

Malchow, H. L.↗

A tentative identification of /C-13/H4 and an estimate of C-12/C-13 in the atmosphere of Jupiter.

Laboratory spectra of the 3nu(sub 3) band of (C-13)H4 at 1.1 micron were analyzed along with high-resolution image-tube spectra of Jupiter in the appropriate spectral region. Comparison of several J-multiplets in these spectra resulted in the identification of (C-13)H4 in the atmosphere of Jupiter. A Jovian C-12/C-13 isotopic abundance ratio of 110 (plus or minus 35) has been derived from the equivalent width of the R(2) multiplet measured on the two best spectrograms.

Fox, K.↗

Performance characteristics of proximity focused ultraviolet image converters

Performance characteristics of Bendix type BX 8025-4522 proximity focused image tubes for ultraviolet to visible light conversion are presented. Quantum efficiency, resolution, background, geometric distortion, and environmental test results are discussed. The converters use magnesium fluoride input windows with Cs - Te photocathodes, and P-11 phosphors on fiber optic output windows.

Williams, J. T.↗

A study of the unidentified interstellar diffuse features.

The interstellar diffuse lines at 5780 and 5797 A have been observed in 66 stars using the Washburn Observatory echelle spectrograph coupled with an image tube. At a resolution of 0.17 A, the profiles of these diffuse lines are asymmetric and steeper to the blue. There is also a broad, shallow feature shortward of 5780 A. The FWHM of 5780 and 5797 are respectively 2.7 A and 1.1 A. Equivalent widths of 5780, 5797 have been measured at a resolution of 0.26 A, and they present a very tight correlation. It is very likely that these two diffuse lines are carried by the same agent. This investigation proposes that the two lines are produced by the pure electronic transitions of the impurity centers in solid grains, with the broad, shallow absorption feature shortward of 5780 A as the absorption sideband associated with the parent pure electronic line.

Wu, C.-C.↗