Search NASA⌕ Search

SEARCH · Search NASA

Results for “IMPEDANCE PROBE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Noncontact Measurement Of Sizes And Eccentricities Of Holes

Semiautomatic eddy-current-probe apparatus makes noncontact measurements of nominally round holes in electrically conductive specimens and processes measurement data into diameters and eccentricities of holes. Includes x-y translation platform, which holds specimen and moves it horizontally. Probe mounted on probe scanner, positioning probe along vertical (z) direction and rotates probe about vertical axis at preset low speed. Eddy-current sensing coil mounted in side of probe near tip. As probe rotates, impedance analyzer measures electrical impedance (Z) of coil as function of instantaneous rotation angle. Translation and rotation mechanisms and impedance analyzer controlled by computer, which also processes impedance-measurement data.

Chern, Engmin J.↗

High temperature conductivity of potassium-beta(double prime)-alumina

Potassium beta(double prime)-alumina (BDPA) single crystals have been reported by several groups to leave higher ionic conductivity than sodium BDPA crystals at room temperature, and similar conductivities are obtained at temperatures up to 600-700 K. Potassium BDPA ceramics have been reported to have significantly poorer conductivities than those of sodium BDPA ceramics, but conductivity measurements at temperatures above 625 K have not been reported. In this study, K(+)-BDPA ceramics were prepared from Na(+)-BDPA ceramic using a modified version of the exchange reaction with KCl vapor reported by Crosbie and Tennenhouse (1982), and the conductivity has been measured in K vapor at temperatures up to 1223 K, using the method of Cole et al. (1979). The results indicate reasonable agreement with earlier data on K(+)-BDPA ceramic measured in a liquid K cell, but show that the K(+)-BDPA ceramic's conductivity approaches that of Na(+)-BDPA ceramic at higher temperatures, being within a factor of four at 700 K and 60 percent of the conductivity of Na(+)-BDPA at T over 1000 K. Both four-probe dc conductivity and four probe ac impedance measurements were used to characterize the conductivity. A rather abrupt change in the grain boundary resistance suggesting a possible phase change in the intergranular material, potassium aluminate, is seen in the ac impedance behavior.

Williams, R. M.↗

A microstrip array feed for land mobile satellite reflector antennas

A circularly polarized feed array for a spacecraft reflector antenna is described that was constructed by using linearly polarized microstrip elements. The array has seven subarrays which form a single cluster as part of a large overlapping cluster reflector feed array. Each of the seven subarrays consists of four linearly polarized microstrip elements. The array achieved a better than 0.8-dB axial ratio at the array pattern peak and better than 3 dB antenna gain to 20 degrees from the peak, across a 7.5 percent frequency bandwidth. A teardrop-shaped feed probe was used to achieve wideband input impedance matching for the relatively thick microstrip substrate. The low impedance and axial ratio bandwidths were achieved using a relatively thick honeycomb substrate with the impedance-matching feed probes.

Huang, John↗

Impedance properties of circular microstrip antenna

A moment method solution to the input impedance of a circular microstrip antenna excited by either a microstrip feed or a coaxial probe is presented. Using the exact dyadic Green's function and the Fourier transform the problem is formulated in terms of Richmond's reaction integral equation from which the unknown patch current can be solved for. The patch current is expanded in terms of regular surface patch modes and an attachment mode (for probe excited case) which insures continuity of the current at probe/patch junction, proper polarization and p-dependance of patch current in the vicinity of the probe. The input impedance of a circular microstrip antenna is computed and compared with earlier results. Effect of attachment mode on the input impedance is also discussed.

Deshpande, M. D.↗

Method and Apparatus for Measuring Fluid Flow

Method and apparatus for making measurements on fluids related to their complex permeability are disclosed. A microwave probe is provided for exposure to the fluids. The probe can be non-intrusive or can also be positioned at the location where measurements are to be made. The impedance of the probe is determined. in part. by the complex dielectric constant of the fluids at the probe. A radio frequency signal is transmitted to the probe and the reflected signal is phase and amplitude detected at a rapid rate for the purpose of identifying the fluids. Multiple probes may be selectively positioned to monitor the behavior of the fluids including their flow rate. Fluids may be identified as between two or more different fluids as well as multiple phases of the same fluid based on differences between their complex permittivities.

Arndt, G. Dickey↗

Pressure probe and hot-film probe rsponses to acoustic excitation in mean flow

An experiment was conducted to compare the relative responses of a hot-film probe and a pressure probe positioned in a flow duct carrying mean flow and progressive acoustic waves. The response of each probe was compared with that of a condenser-type microphone flush mounted in the duct wall for flow Mach numbers up to about 0.5. The response of the pressure probe was less than that of the flush-mounted microphone by not more than about 2.1 dB at the highest centerline Mach number. This decreased response of the probe can likely be attributed to flow-induced impedance changes at the probe sensor orifices. The response of the hot-film probe, expressed in terms of fluctuating pressure, was greater than that of the flush-mounted microphone by as much as 6.0 dB at the two higher centerline Mach numbers. Removal of the contribution from fluctuating temperature in the hot-film analytical model greatly improved the agreement between the two transducer responses.

Parrott, T. L.↗

Turbofan aft duct suppressor study

Suppressions due to acoustic treatment in the annular exhaust duct of a model fan were theoretically predicted and compared with measured suppressions. The predictions are based on the modal analysis of sound propagation in a straight annular flow duct with segmented treatment. Modal distributions of the fan noise source (fan-stator interaction only) were measured using in-duct modal probes. The flow profiles were also measured in the vicinity of the modal probes. The acoustic impedance of the single degree of freedom treatment was measured in the presence of grazing flow. The measured values of mode distribution of the fan noise source, the flow velocity profile and the acoustic impedance of the treatment in the duct were used as input to the prediction program. The predicted suppressions, under the assumption of uniform flow in the duct, compared well with the suppressions measured in the duct for all test conditions. The interaction modes generated by the rotor-stator interaction spanned a cut-off ratio range from nearly 1 to 7.

Syed, A. A.↗

Stratospheric conductivity variations over thunderstorms

This paper reports the first in-situ observation of variations in the electrical conductivity over thunderstorms at 26 km altitude. The vector electric field, positive and negative polar conductivity, and optical lightning power/flash were measured by payloads on superpressure balloons in the Southern Hemisphere in early 1984. It is found that in 72 percent of the thunderstorm periods observed (or in 23 of 32 periods) there were clear cases of conductivity variations while the balloons were over the thunderstorms. Examples from two separate balloons at widely separated dates and locations showing both daytime and nighttime events are presented. The conductivity measurements are made with the relaxation technique, and the vector field measurements are based on the double Langmuir probe high-impedance method. It is found that the positive and negative conductivity measurements vary independently and have a different temporal profile than the dc electric field. The polar conductivity variations can exceed a factor of 2 at this altitude. In seven of the nine most intense thunderstorm events the total conductivity increased, while in only one of these nine events did it decrease (one event had no change). Implications of these observations for global current patterns are discussed.

Holzworth, R. H.↗

A microstrip array feed for MSAT spacecraft reflector antenna

An L-band circularly polarized microstrip array antenna with relatively wide bandwidth has been developed. The array has seven subarrays which form a single cluster as part of a large overlapping cluster reflector feed array. Each of the seven subarrays consists of four uniquely arranged linearly polarized microstrip elements. A 7.5 percent impedance (VSWR less than 1.5) as well as axial ratio (less than 1 dB) bandwidths have been achieved by employing a relatively thick honeycomb substrate with special impedance matching feed probes.

Huang, John↗

Thunderstorm related variations in stratospheric conductivity measurements

The vector electric field and polar conductivities were measured by zero-pressure balloon-borne payloads launched from Wallops Island, Virgina during the summers of 1987 and 1988. Data were collected over thunderstorms (or electrified clouds) during 6-hour flights at altitudes near 30 km. The vector electric field measurements were made with the double Langmuir probe high-impedance method, and the direct conductivity measurements were obtained with the relaxation technique. Evidence is presented for conductivity variations over thunderstorms (or electrified clouds). It is found that both positive and negative polar conductivity data do show variations of up to a factor of 2 from ambient values associated with the disturbed periods. Some ideas for possible physical mechanisms which may be responsible for the conductivity variations over thunderstorms are also discussed in this paper.

Hu, Hua↗

Modeling and Characterization of Cavity Backed Circular Aperture Antenna With Suspended Stripline Probe Feed

The paper presents the numerically simulated input impedance of a cavity backed circular aperture antenna with suspended substrate stripline probe feed. The simulation is based on the finite element method. The results show the input impedance or the return loss as a function of the frequency with the probe dimensions as parameters. The simulated results are validated by measurements at millimeter-wave frequencies.

Chun, Donghoon↗

Investigation of a Gallium MPD Thruster with an Ablating Cathode

Arc impedance, exhaust velocity, and plasma probe measurements are presented. The thruster is driven by a 50 microsecond pulse from a 6.2 milliohm pulse forming network, and gallium is supplied to the discharge by evaporation of the cathode. The arc voltage is found to vary linearly with the discharge current with an arc impedance of 6.5 milliohms. Electrostatic probes yield an exhaust velocity that is invariant with the discharge current and has a peak value of 20 kilometers per second, which is in reasonable agreement with the value (16 plus or minus 1 kilometer per second) calculated from the mass bit and discharge current data. Triple probe measurements yield on axis electron temperatures in the range of 0.8-3.8 eV, electron densities in the range of 1.6 x 10(exp 21) to 2.1 x 10(exp 22) per cubic meter, and a divergence half angle of 16 degrees. Measurements within the interelectrode region yield a peak magnetic field of 0.8 T, and the observed radial trends are consistent with an azimuthally symmetric current distribution. A cathode power balance model is coupled with an ablative heat conduction model predicting mass bit values that are within 20% of the experimental values.

Thomas, Robert E.↗

Non-Contact EDDY Current Hole Eccentricity and Diameter Measurement

Precision holes are among the most critical features of a mechanical component. Deviations from permissible tolerances can impede operation and result in unexpected failure. We have developed an automated non-contact eddy current hole diameter and eccentricity measuring system. The operating principle is based on the eddy current lift-off effect, which is the coil impedance as a function of the distance between the coil and the test object. An absolute eddy current probe rotates in the hole. The impedance of each angular position is acquired and input to the computer for integration and analysis. The eccentricity of the hole is the profile of the impedance as a function of angular position as compared to a straight line, an ideal hole. The diameter of the hole is the sum of the diameter of the probe and twice the distance-calibrated impedance. An eddy current image is generated by integrating angular scans for a plurality of depths between the top and bottom to display the eccentricity profile. This system can also detect and image defects in the hole. The method for non-contact eddy current hole diameter and eccentricity measurement has been granted a patent by the U.S. Patent and Trademark Office.

Chern, E. James↗

RF Metrology of Lunar Highlands Regolith Simulant NU-LHT-2M

Understanding the electrical properties of lunar regolith is vital to modeling radiofrequency(RF) propagation on the lunar surface a fundamental step in planning lunar surface missions. Near the lunar south pole, the regolith has yet to be directly sampled and thus there remains uncertainty in the electrical properties of the regolith. The regolith simulant NU-LHT-2M is a highlands simulant that is representative of the expected chemical composition of the regolith near the lunar south pole. Previous studies have investigated properties of NU-LHT at UHF and S-band[1]. Future missions to the lunar south pole are expected to utilize X and Ka-band for direct-to-Earth links and UHF, S-band, C-band, and Ka-band for lunar surface communication[2]. As a result, it is necessary to electrically characterize the lunar regolith at these frequencies. In this paper, coaxial impedance dielectric reflectometry is performed on the NU-LHT-2M simulant using a commercially available soil permittivity measurement device. This study serves as a preliminary measurement of the simulant and may lead to enhanced efficacy of the measurement hardware for future applications.

simulant↗

RF Metrology of Lunar Highlands Regolith Simulant NU-LHT-2M

*Presentation for the publication* Understanding the electrical properties of lunar regolith is vital to modeling radiofrequency (RF) propagation on the lunar surface, a fundamental step in planning lunar surface missions. Near the lunar south pole, the regolith has yet to be directly sampled and thus there remains uncertainty in the electrical properties of the regolith. The regolith simulant NU-LHT-2M is a highlands simulant that is representative of the expected chemical composition of the regolith near the lunar south pole. Previous studies have investigated properties of NU-LHT at UHF and S-band[1]. Future missions to the lunar south pole are expected to utilize X and Ka-band for direct-to-Earth links and UHF, S-band, C-band, and Ka-band for lunar surface communication [2]. As a result, it is necessary to electrically characterize the lunar regolith at these frequencies. In this paper, coaxial impedance dielectric reflectometry is performed on the NU-LHT-2M simulant using a commercially available soil permittivity measurement device. This study serves as a preliminary measurement of the simulant and may lead to enhanced efficacy of the measurement hardware for future applications.

simulant↗

Acoustics of the piezo-electric pressure probe

Acoustical properties of a piezoelectric device are reported for measuring the pressure in the plasma flow from an MPD arc. A description and analysis of the acoustical behavior in a piezoelectric probe is presented for impedance matching and damping. The experimental results are presented in a set of oscillographic records.

Dutt, G. S.↗