Search NASASearch

SEARCH · Search NASA

Results for “INERTIA”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

The Effect of Longitudinal Moment of Inertia upon Dynamic Stability

Free flight tests were carried out to show whether the longitudinal oscillations of a standard S.E.5A airplane are noticeably affected if its longitudinal moment of inertia is increased. These oscillations were taken by means of a self-recording instrument, the airplane having first its ordinary moment of inertia and then one increased by 14 percent. The period of oscillation was slightly longer after the increase of the moment of inertia, but the damping was not affected. Presented here are test results from an investigation to determine the relative performance of a single-cylinder, high-speed, compression-ignition engine when using fuel injection valve nozzles with different numbers, sizes, and directions of round orifices. A spring loaded, automatic injection valve was used. It was centrally located at the top of a vertical disk-type combustion chamber formed between horizontally opposed inlet and exhaust valves of a 5-inch by 7-inch engine. A series of fuel injection valve nozzles with different arrangements of round orifices were tested, starting with orifices so small that impingement on the combustion chamber walls was impossible and increasing beyond the start of impingement. a :A table and curves are presented showing the performance of the engine with different nozzles. The test results are discussed, and some probable reasons given for the variation in performance with different nozzles on the basis of spray distribution.

MOMENTS OF INERTIA - ROYAL AIRCRAFT FACTORY S E 5A

Estimation of moments of inertia of airplanes from design data

A method of determining the moments of inertia of an airplane from design data pertaining to the weights and locations of the component parts is described. The computations required to ascertain the center-of-gravity position are incorporated with the calculations of moments of inertia. A complete set of data and calculations for a modern airplane is given to illustrate the procedure. From a comparison between calculated values and measured values it is believed that the moments of inertia can be estimated within 10 percent by the use of this method.

AIRPLANES - DESIGN

Testing and Validation of the Dynamic Inertia Measurement Method

The Dynamic Inertia Measurement (DIM) method uses a ground vibration test setup to determine the mass properties of an object using information from frequency response functions. Most conventional mass properties testing involves using spin tables or pendulum-based swing tests, which for large aerospace vehicles becomes increasingly difficult and time-consuming, and therefore expensive, to perform. The DIM method has been validated on small test articles but has not been successfully proven on large aerospace vehicles. In response, the National Aeronautics and Space Administration Armstrong Flight Research Center (Edwards, California) conducted mass properties testing on an "iron bird" test article that is comparable in mass and scale to a fighter-type aircraft. The simple two-I-beam design of the "iron bird" was selected to ensure accurate analytical mass properties. Traditional swing testing was also performed to compare the level of effort, amount of resources, and quality of data with the DIM method. The DIM test showed favorable results for the center of gravity and moments of inertia; however, the products of inertia showed disagreement with analytical predictions.

moments of inertia

Determining Aircraft Moments of Inertia from Flight Test Data

Flight test maneuver design and dynamic modeling techniques were developed for determining aircraft moments of inertia from flight test data. Full nonlinear rigid-body rotational equations of motion were used in the analysis, with aerodynamic moment dependencies modeled by linear expansions in the aircraft states and controls. Aerodynamic parameters were estimated simultaneously with inertia parameters using equation-error modeling applied to flight test data from maneuvers designed specifically for this problem. The approach was demonstrated using a nonlinear F-16 simulation, then applied to a remotely-piloted subscale aircraft flight test. Errors in the aircraft moment of inertia parameters determined from simulated F-16 flight test maneuver data were less than 6 percent compared to the true values in the simulation. Flight test results for the subscale aircraft were within 6 percent of ground-test values obtained using the same aircraft.

moments of inertia

Determining Aircraft Moments of Inertia from Flight Test Data

Flight test maneuver design and dynamic modeling techniques were developed for determining aircraft moments of inertia from flight test data. Full nonlinear rigid-body rotational equations of motion were used in the analysis, with aerodynamic moment dependencies modeled by linear expansions in the aircraft states and controls. Aerodynamic parameters were estimated simultaneously with inertia parameters using equation-error modeling applied to flight test data from maneuvers designed specifically for this problem. The approach was demonstrated using a nonlinear F 16 simulation, then applied to a remotely piloted subscale aircraft flight test. Errors in the aircraft moment of inertia parameters determined from simulated F-16 flight test maneuver data were less than 6 percent compared to the true values in the simulation. Flight test results for the subscale aircraft were within 6 percent of ground-test values obtained using the same aircraft.

Aircraft Moments of Inertia

Sleep & Sleep Inertia

Sleep inertia, or the grogginess felt upon awakening, is associated with significant cognitive performance decrements that dissipate as time awake increases. This presentation will cover the: 1) causes of sleep inertia including the interaction with homeostatic and circadian pressures and neural correlates; 2) consequences for cognitive performance from both laboratory studies and real world incidents; and 3) novel countermeasures currently being investigated to lessen the impact of sleep inertia.

sleep inertia

Determining Aircraft Moments of Inertia from Flight Test Data

Flight test maneuvers and dynamic modeling techniques were developed for determining aircraft moments of inertia from flight test data. Full nonlinear rigid-body rotational equations of motion were used in the analysis, with aerodynamic moment dependencies modeled by linear expansions in the aircraft states and controls. Aerodynamic parameters were estimated simultaneously with inertia parameters using equation-error modeling applied to flight test data from maneuvers designed specifically for this problem. The approach was demonstrated using a nonlinear F 16 simulation, then applied to a remotely-piloted subscale aircraft flight test. Errors in the aircraft moment of inertia parameters determined from simulated F-16 flight test data were less than 6 percent compared to the true values in the simulation. Flight test results for the subscale aircraft were within 6 percent of ground-test values obtained using the same aircraft.

Parameter estimation

Light as a Reactive Countermeasure to Sleep Inertia: Translating Laboratory Findings to the Field

Sleep inertia describes the brief period of impaired alertness, mood, and cognitive performance experienced after waking. Under laboratory settings, light exposure upon waking during a habitual sleep period has been shown to improve sleep inertia symptoms. We investigated whether a field-deployable light-emitting device would help to mitigate sleep inertia in a real-world setting. Thirty-six participants (18 female; 26.6 years ± 6.1) completed an at-home, within-subject, randomized crossover study. Participants followed their habitual sleep-wake schedule for five nights before an adaptation and experimental night. Forty-five minutes after bedtime on the experimental night, participants received a phone call and were instructed to wear light-emitting glasses with the light either on (light condition) or off (control). A 5-minute psychomotor vigilance task (PVT), the Karolinska Sleepiness Scale (KSS), visual analog scales of mood (VASmood), and a 3-minute descending subtraction task (DST) were performed starting at +2, +12, +22, and +32 minutes after the call. Participants then went back to sleep and were called 45 minutes after lights out for the opposite condition. A series of mixed-effects models were performed with fixed effects of test bout, condition, test bout × condition, and a random effect of participant. Covariates included pre-sleep baseline scores, randomization order, sex, and sleep history. Participants rated themselves as more alert and energetic in the light condition compared to the control condition (VASalert-sleepy p = .01; VASlethargic-energetic p = .001). There was no effect of condition for DST outcomes, but there was a significant improvement in DST total responses in the light condition in a subset of participants waking from N3 (p = .03). There was a significant effect of condition for PVT outcomes, with faster responses (p < .001) and fewer lapses (p < .001) in the control condition. Our results under naturalistic at-home settings suggest that, similar to the in-laboratory study findings, the light intervention improved subjective alertness and mood, while working memory improved after waking from N3. Future studies of light interventions should include measures of visual acuity and comfort to assess the full feasibility and efficacy of interventions in real-world environments.

sleep inertia

Light as a Reactive Countermeasure to Sleep Inertia: Translating Laboratory Findings to the Field

Sleep inertia describes the brief period of impaired alertness, mood, and cognitive performance experienced after waking. Under laboratory settings, light exposure upon waking during a habitual sleep period has been shown to improve sleep inertia symptoms. We investigated whether a field-deployable light-emitting device would help to mitigate sleep inertia in a real-world setting.\ Thirty-six participants (18 female; 26.6 years ± 6.1) completed an at-home, within-subject, randomized crossover study. Participants followed their habitual sleep-wake schedule for five nights before an adaptation and experimental night. Forty-five minutes after bedtime on the experimental night, participants received a phone call and were instructed to wear light-emitting glasses with the light either on (light condition) or off (control). A 5-minute psychomotor vigilance task (PVT), the Karolinska Sleepiness Scale (KSS), visual analog scales of mood (VASmood), and a 3-minute descending subtraction task (DST) were performed starting at +2, +12, +22, and +32 minutes after the call. Participants then went back to sleep and were called 45 minutes after lights out for the opposite condition. A series of mixed-effects models were performed with fixed effects of test bout, condition, test bout × condition, and a random effect of participant. Covariates included pre-sleep baseline scores, randomization order, sex, and sleep history. Participants rated themselves as more alert and energetic in the light condition compared to the control condition (VASalert-sleepy p = .01; VASlethargic-energetic p = .001). There was no effect of condition for DST outcomes, but there was a significant improvement in DST total responses in the light condition in a subset of participants waking from N3 (p = .03). There was a significant effect of condition for PVT outcomes, with faster responses (p < .001) and fewer lapses (p < .001) in the control condition. Our results under naturalistic at-home settings suggest that, similar to the in-laboratory study findings, the light intervention improved subjective alertness and mood, while working memory improved after waking from N3. Future studies of light interventions should include measures of visual acuity and comfort to assess the full feasibility and efficacy of interventions in real-world environments.

sleep inertia

Light as a Reactive Countermeasure to Sleep Inertia: Translating Laboratory Findings to the Field

Sleep inertia describes the brief period of impaired alertness, mood, and cognitive performance experienced after waking. Under laboratory settings, light exposure upon waking during a habitual sleep period has been shown to improve sleep inertia symptoms. We investigated whether a field-deployable light-emitting device would help to mitigate sleep inertia in a real-world setting. Thirty-six participants (18 female; 26.6 years ± 6.1) completed an at-home, within-subject, randomized crossover study. Participants followed their habitual sleep-wake schedule for five nights before an adaptation and experimental night. Forty-five minutes after bedtime on the experimental night, participants received a phone call and were instructed to wear light-emitting glasses with the light either on (light condition) or off (control). A 5-minute psychomotor vigilance task (PVT), the Karolinska Sleepiness Scale (KSS), visual analog scales of mood (VASmood), and a 3-minute descending subtraction task (DST) were performed starting at +2, +12, +22, and +32 minutes after the call. Participants then went back to sleep and were called 45 minutes after lights out for the opposite condition. A series of mixed-effects models were performed with fixed effects of test bout, condition, test bout × condition, and a random effect of participant. Covariates included pre-sleep baseline scores, randomization order, sex, and sleep history. Participants rated themselves as more alert and energetic in the light condition compared to the control condition (VASalert-sleepy p = .01; VASlethargic-energetic p = .001). There was no effect of condition for DST outcomes, but there was a significant improvement in DST total responses in the light condition in a subset of participants waking from N3 (p = .03). There was a significant effect of condition for PVT outcomes, with faster responses (p < .001) and fewer lapses (p < .001) in the control condition. Our results under naturalistic at-home settings suggest that, similar to the in-laboratory study findings, the light intervention improved subjective alertness and mood, while working memory improved after waking from N3. Future studies of light interventions should include measures of visual acuity and comfort to assess the full feasibility and efficacy of interventions in real-world environments.

sleep inertia

Jet Lag, Sleep Timing, and Sleep Inertia

This chapter explores the causes, consequences, and countermeasures of jet lag, mistimed sleep, and sleep inertia. Jet lag can occur when rapidly crossing multiple time zones (e.g., trans-meridian travel for long-haul pilots). The desynchrony between the body’s biological clock, or circadian rhythm, and the new day-night cycle can lead to indigestion, sleep disturbances, fatigue, and cognitive impairments. Mistimed sleep can also occur within a time zone. In the case of night shiftwork, sleep is displaced to the daytime which leads to poor sleep and increased fatigue at night due to the combination of pressures from the two-process model of sleep regulation: sleep loss (homeostatic pressure); and being awake when the body is promoting sleep (circadian pressure). There is also a third process of sleep regulation called sleep inertia, which refers to the brief period of fatigue and impaired cognitive performance experienced after waking. Sleep inertia can be a fatigue risk for transportation workers who work on-call (e.g., emergency services) or who nap on shift (e.g., long-haul truck drivers) and are required to perform a safety-critical task soon after waking. For each of these fatigue risks, strategic exposure to bright light can be used to help realign sleep timing and to promote alertness.

sleep inertia

Cybersecurity Challenges in Low-Inertia Power-Electronics-Dominated Grids

Here, the low inertia characteristics of the power electronics dominated grid (PEDG) introduces challenges while restoring voltage and frequency to their nominal values. These stability challenges create new cybersecurity vulnerabilities that are not thoroughly discussed in the literature. Cyber events such as false data injection (FDI), denial of service (DoS), man-in-the-middle attacks, stealthy attacks, and advanced persistent threats target PEDG to disrupt grid stability or gain financial benefits. The low inertia of PEDG (< 2s) compared to traditional grids (~10s) exacerbates these vulnerabilities. In response to stealthy attacks on state variables that supervisory layers cannot detect until significant harm occurs, the low inertia characteristics of PEDG offer substantial stealthy attack surfaces. To counteract such threats, PEDG must be equipped with ultra-fast real-time anomaly detection system and trajectory prediction mechanism to achieve effective cyberattack resiliency.

24 POWER TRANSMISSION AND DISTRIBUTION

Frequency-Nadir-Constrained Unit Commitment for Low-Inertia, High-IBR Island Power Systems [Slides]

The process of energy decarbonization in island power systems is accelerated due to the swift integration of inverter-based renewable energy resources (IBRs). The unique features of such systems, including rapid frequency changes resulting from potential generation outages or imbalances due to the unpredictability of renewable power, pose a significant challenge in maintaining the frequency nadir without external support. This paper presents a unit commitment (UC) model with data-driven frequency nadir constraints, including either frequency nadir or minimum inertia requirements, helping to limit frequency deviations after significant generator outages. The constraints are formulated using a linear regression model that takes advantage of real-world, year-long generation scheduling and dynamic simulation data. The efficacy of the proposed UC model is verified through a year-long simulation in an actual island power system using historical weather data. The alternative minimum inertia constraint, derived from actual system operation assumptions, is also evaluated. Findings demonstrate that the proposed frequency nadir constraint notably improves the system's frequency nadir under high photovoltaic (PV) penetration levels, albeit with a slight increase in generation costs, when compared to the alternative minimum inertia constraint.

14 SOLAR ENERGY

A method for attitude control of a satellite in circular orbit by actively varying its inertia.

Equations are developed for a vehicle consisting of a system of particles which move in a generally prescribed fashion. These equations are then specialized to apply to a rigid vehicle with a constant amount of fluid contained in tanks and flowing through interconnecting lines. Various simplifications and specialized forms of the equations are derived, and relationships between mass and inertia that result from the fluid transfer logic and the physical constraints of the configuration are formulated. A tank arrangement and fluid transfer logic are devised which permit each vehicle product of inertia to be varied without varying the remaining elements of the inertia matrix or shifting the center of mass. Vehicle control is achieved by sensing angular rate and the local vertical and by transferring fluid as a function of these variables.

Clarke, W. D.

Effect of inertia properties on attitude stability of nonrigid spin-stabilized spacecraft

The phenomenon of energy dissipation in spinning spacecraft is discussed with particular reference to its dependence on spacecraft inertia properties. Specific dissipation mechanisms are identified. The effect of external environmental factors on spin stability is also discussed. Generalized curves are presented relating system stability to the principal inertia ratio for various forms of energy dissipation. Dual-spin systems and the effect of lateral inertia asymmetry are also reviewed.

Lang, W. E.

Thermal inertia mapping

A thermal model of the earth's surface has been developed and used to determine the thermal inertia of a test site in the Mojave Desert, California. The model, which includes meteorological heating terms as well as radiation and conduction heating terms, is used with remotely sensed surface temperature data to determine thermal inertia of materials. The thermal inertia is displayed in image form, and can aid in the differentiation of the various lithologic materials in the test site.

Kahle, A. B.

Thermal inertia imaging - A new geologic mapping tool

A thermal model of the earth's surface has been developed and used to determine the thermal inertia of a test site in the Mojave Desert, California. The model, which includes meteorological heating terms as well as radiation and conduction heating terms, is used with remotely sensed surface temperature and reflectance data to determine the thermal inertia of the surface materials at the test site. The thermal inertia is displayed in image form, and can aid in the differentiation of the various lithologic materials in the test site. Since this thermal property is representative of the upper several cm of the surface, it complements visible and reflected near-IR image data.

Kahle, A. B.

Thermal inertia mapping - A new view of the earth

The thermal response of a substance to a time-varying surface power input is determined by its thermal inertia. Remote sensing (e.g., from satellites) can be utilized to measure this property, which is related to surface composition or to near-surface soil moisture. An algorithm is developed which relates thermal inertia to remote measurements of surface temperature and reflectance. Application to geosynchronous satellite data illustrates the contrast between irrigated and desert areas in the region north of the Gulf of California. The effect of local weather conditions (latent and sensible heat transfer to the atmosphere) must be estimated before precise values for thermal inertia can be specified.

Price, J. C.