Search NASA⌕ Search

SEARCH · Search NASA

Results for “INSTRUMENT & FEATURES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Perception Testing in Fog for Autonomous Flight

As the path towards Urban Air Mobility (UAM) continues to take shape, there are outstanding technical challenges to achieving safe and effective air transportation operations under this new paradigm. To inform and guide technology development for UAM, NASA is investigating the current state-of-the-art in key technology areas including traffic management, detect-and-avoid, and autonomy. In support of this effort, a new perception testbed was developed at NASA Ames Research Center to collect data from an array of sensing systems representative of those that could be found on a future UAM vehicle. This testbed, featuring a Light-Detection-and-Ranging (LIDAR) instrument, a long-wave infrared sensor, and a visible spectrum camera was deployed for a multiday test campaign in the Fog Chamber at Sandia National Laboratories (SNL), in Albuquerque, New Mexico. During the test campaign, fog conditions were created for tests with targets including a human, a resolution chart, and a small unmanned aerial vehicle (sUAV). Here, this paper describes in detail, the developed perception testbed, the experimental setup in the fog chamber, the resulting data, and presents an initial result from analysis of the data with the evaluation of methods to increase contrast through filtering techniques.

aeronautics↗

Accurate determination of genotypic variance of cell wall characteristics of a Populus trichocarpa pedigree using high-throughput pyrolysis-molecular beam mass spectrometry

Abstract Background Pyrolysis-molecular beam mass spectrometry (py-MBMS) analysis of a pedigree of Populus trichocarpa was performed to study the phenotypic plasticity and heritability of lignin content and lignin monomer composition. Instrumental and microspatial environmental variability were observed in the spectral features and corrected to reveal underlying genetic variance of biomass composition. Results Lignin-derived ions (including m/z 124, 154, 168, 194, 210 and others) were highly impacted by microspatial environmental variation which demonstrates phenotypic plasticity of lignin composition in Populus trichocarpa biomass. Broad-sense heritability of lignin composition after correcting for microspatial and instrumental variation was determined to be H 2 = 0.56 based on py-MBMS ions known to derive from lignin. Heritability of lignin monomeric syringyl/guaiacyl ratio ( S / G ) was H 2 = 0.81. Broad-sense heritability was also high (up to H 2 = 0.79) for ions derived from other components of the biomass including phenolics (e.g., salicylates) and C5 sugars (e.g., xylose). Lignin and phenolic ion abundances were primarily driven by maternal effects, and paternal effects were either similar or stronger for the most heritable carbohydrate-derived ions. Conclusions We have shown that many biopolymer-derived ions from py-MBMS show substantial phenotypic plasticity in response to microenvironmental variation in plantations. Nevertheless, broad-sense heritability for biomass composition can be quite high after correcting for spatial environmental variation. This work outlines the importance in accounting for instrumental and microspatial environmental variation in biomass composition data for applications in heritability measurements and genomic selection for breeding poplar for renewable fuels and materials.

09 BIOMASS FUELS↗

Adaptive sampling for accelerating neutron diffraction-based strain mapping *

Abstract Neutron diffraction is a useful technique for mapping residual strains in dense metal objects. The technique works by placing an object in the path of a neutron beam, measuring the diffracted signals and inferring the local lattice strain values from the measurement. In order to map the strains across the entire object, the object is stepped one position at a time in the path of the neutron beam, typically in raster order, and at each position a strain value is estimated. Typical dwell times at neutron diffraction instruments result in an overall measurement that can take several hours to map an object that is several tens of centimeters in each dimension at a resolution of a few millimeters, during which the end users do not have an estimate of the global strain features and are at risk of incomplete information in case of instruments outages. In this paper, we propose an object adaptive sampling strategy to measure the significant points first. We start with a small initial uniform set of measurement points across the object to be mapped, compute the strain in those positions and use a machine learning technique to predict the next position to measure in the object. Specifically, we use a Bayesian optimization based on a Gaussian process regression method to infer the underlying strain field from a sparse set of measurements and predict the next most informative positions to measure based on estimates of the mean and variance in the strain fields estimated from the previously measured points. We demonstrate our real-time measure-infer-predict workflow on additively manufactured steel parts—demonstrating that we can get an accurate strain estimate even with 30%–40% of the typical number of measurements—leading the path to faster strain mapping with useful real-time feedback. We emphasize that the proposed method is general and can be used for fast mapping of other material properties such as phase fractions from time-consuming point-wise neutron measurements.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

DEIMoS: An Open-Source Tool for Processing High-Dimensional Mass Spectrometry Data

We present DEIMoS: Data Extraction for Integrated Multidimensional Spectrometry, a Python application programming interface and command-line tool for high-dimensional mass spectrometry data analysis workflows, offering ease of development and access to efficient algorithmic implementations. Functionality includes feature detection, feature alignment, collision cross section calibration, isotope detection, and MS/MS spectral deconvolution, with the output comprising detected features aligned across study samples and characterized by mass, CCS, tandem mass spectra, and isotopic signature. Notably, DEIMoS operates on N-dimensional data, largely agnostic to acquisition instrumentation: algorithm implementations utilize all dimensions simultaneously to (i) offer greater separation between features, improving detection sensitivity, (ii) increase alignment/feature matching confidence among datasets, and (iii) mitigate convolution artifacts in tandem mass spectra. We demonstrate DEIMoS with LC-IMS-MS/MS data, demonstrating the advantages of a multidimensional approach in each data processing step.

Colby, Sean M↗

Relativistic ultrafast electron diffraction at high repetition rates

The ability to resolve the dynamics of matter on its native temporal and spatial scales constitutes a key challenge and convergent theme across chemistry, biology, and materials science. The last couple of decades have witnessed ultrafast electron diffraction (UED) emerge as one of the forefront techniques with the sensitivity to resolve atomic motions. Increasingly sophisticated UED instruments are being developed that are aimed at increasing the beam brightness in order to observe structural signatures, but so far they have been limited to low average current beams. Here, we present the technical design and capabilities of the HiRES (High Repetition-rate Electron Scattering) instrument, which blends relativistic electrons and high repetition rates to achieve orders of magnitude improvement in average beam current compared to the existing state-of-the-art instruments. The setup utilizes a novel electron source to deliver femtosecond duration electron pulses at up to MHz repetition rates for UED experiments. Instrument response function of sub-500 fs is demonstrated with < 100 fs time resolution targeted in future. We provide example cases of diffraction measurements on solid-state and gas-phase samples, including both micro- and nanodiffraction (featuring 100 nm beam size) modes, which showcase the potential of the instrument for novel UED experiments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Instrument Control Software for Spectrophotometers

SRNL has developed instrument control software for diode array spectrophotometers that can be used for real time monitoring of dynamic systems. This software has evolved through several iterations as instruments have been developed for use in processing facilities at Savannah River Site. There are several noteworthy features of the software. The wavelength calibration is checked and updated in real time against reference emission lines that are designed into the instrument light source. Nonlinearities and offsets associated with the intensity response of the instruments are characterized, and absorbance spectra are appropriately corrected. These actions are necessary for accurate calculation of an absorbance spectrum from the intensity responses of two individual diode array detectors. The corrections also result in the spectra obtained for a particular sample by two (or more) different diode array detector pairs being nearly identical. This property assures consistent measurements at multiple locations with different instruments. It also permits the use of a single analyte calibration across many instruments without modification and without loss of accuracy

47 OTHER INSTRUMENTATION↗

Rapid Generation of Tandem Mass Spectrometry Reference Libraries Using Immediate Drop-on-Demand Liquid Handling Coupled to an Open Port Sampling Interface

In metabolomics, tandem MS (MS2) fragmentation libraries are important for the identification of unknown features, but generating these libraries takes many valuable hours of instrument and operator time. Here, an immediate droplet-on-demand/open port sampling interface was used to rapidly acquire tandem MS of standards arrayed in a 96-well plate format. A workflow was developed for automated, high-throughput control of MS2 library generation. Pure standard mass spectral libraries were collected on Orbitrap and Q-TOF mass spectrometers for 192 compounds using 6 different collision energies with a throughput of 4 and 7.8 s/spectrum, respectively. Libraries were acquired using different solvent additives, precursor adducts, and ion polarities.

Cahill, John [ORNL] (ORCID:0000000298664010)↗

Selected micrometeorological and soil data from the Manaus ZF2 K34 eddy covariance tower for the 2015/16 El Niño event

The K34 tower site (2.609 S, 60.209 W, 130 masl), located within the Tropical Silviculture Experimental Station (EEST, also known as ZF2) research station, in an area of undisturbed tropical forest (Araújo et al. 2002). It features long term measurements using micrometeorological, eddy covariance, and soil instrumentation, among others. This dataset covers January 2012 to December 2017, and includes air temperature (TA, ℃) and air relative humidity (RH, %), measured with thermohygrometers (HC2S3, Campbell Scientific, Logan, UT, USA) deployed above the canopy at the top of the tower (at 51.1 m height), and net radiation (NETRAD, W m-2) using an NR-LITE sensor (Kipp & Zonen, Delft, Netherlands), also at the top of the tower (at 35.0 m above the canopy). The soil moisture data included here is from a soil profile located approximately 12 m from the tower, and covers the period between February 2015 and September 2016. Volumetric soil water content (SWC, m3 m-3) measurements used Water Content Reflectometers (CS655 Campbell Scientific, Logan, UT, USA) at six depths: 10 cm, 20 cm, 30 cm, 40 cm, 60 cm, and 100 cm. Data are included in .csv files, and the text file ZF2-K34_Tower_headers.txt provides descriptions of data file headers.

54 ENVIRONMENTAL SCIENCES↗

Start-up Operation Experience with a Liquid Fluoride Salt Forced Convection Loop

A liquid fluoride salt forced convection test loop was constructed at Oak Ridge National Laboratory. Its unique features include a pebble bed test section, high-temperature instrumentation, a noncontact rotating gas seal for the pump, a silicon carbide flow tube, and a unique inductive heating technique. Initial startup and shake-down testing has been completed. This paper describes how several of the systems performed, highlights those that worked well, and discusses issues that arose during the start-up process. This discussion should be of interest to those who intend to develop molten salt technologies and who are interested in some of the specific techniques used in this experiment.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Book Chapter: Small Modular Reactors

Small Modular Reactors (SMRs) have been a very promising development in nuclear power over the last two decades. SMRs are defined as nuclear reactors with a power output of less than 300 MWe. This is in comparison to gigawatt-size reactors, which can have electrical output of 1000–1500 MWe or more. This chapter will consist of two major sections. The first will be a detailed summary of the small modular reactor designs being proposed around the world. This section will focus on those that are the furthest along in their development, but will also include some information about the wide variety of proposed designs that require significant research and development. The second part will be a discussion of the remaining challenges to the adoption of SMRs as a major energy source. SMRs are not a new concept, but they do represent a new vision for an older concept. These reactors have the potential to become a major source of energy in the near future. The development of small, modular designs can help promote the adoption of nuclear energy by reducing upfront costs, reducing the financial risk associated with nuclear power, and the barriers to entry. However, the adoption of SMRs is not without challenges. Regulatory and licensing changes to address the unique benefits and concerns associated with SMRs will continue to be a challenge as regulators adapt to the unique features emerging from the design process. The development of new instrumentation and control systems is an ongoing issue. And economics is possibly the most significant challenge, with high construction costs, cheap natural gas, and government subsidies, combining to result in significant financial risk associated with adopting nuclear generation.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

HAZARD ANALYSIS OF DIGITAL ENGINEERED SAFETY FEATURES ACTUATION SYSTEM IN ADVANCED NUCLEAR POWER PLANTS USING A REDUNDANCY-GUIDED APPROACH

Replacing the existing aging analog instrumentation and control (I&C) systems with modern safety control and protection digital technology offers one of the foremost means of performance improvements and cost reductions for the existing nuclear power plants (NPPs). However, the qualification of digital I&C systems remains a challenge, especially considering the issue of software common-cause failures (CCFs), which are difficult to address. With the application and upgrades of advanced digital I&C systems, software CCFs have become a potential threat to plant safety because most redundant designs use similar digital platforms or software in the operating and application systems. With complex designs of multilayer redundancy to meet the single-failure criterion, digital I&C safety systems (e.g., engineered safety-features actuation system [ESFAS]) are of a particular concern in the U.S. Nuclear Regulatory Commission (NRC) licensing procedures. This paper applies a modularized approach to conduct redundancy-guided systems-theoretic hazard analysis for an advanced digital ESFAS with multilevel redundancy designs. Systematic methods and risk-informed tools are incorporated to address both hardware and software CCFs, which provide guidance to eliminate the triggers of potential single points of failure in the design of digital safety systems in advanced plant designs.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Analytics-at-scale of Sensor Data for Digital Monitoring in Nuclear Plants (3 rd Annual Report)

Nuclear power plants collect and store large volumes of heterogeneous data from various components and systems. With recent advances in machine learning (ML) techniques, these data can be leveraged to develop diagnostic and short-term forecasting models to better predict future equipment condition. Maintenance operations can then be planned in advance whenever degraded performance is predicted, thus resulting in fewer unplanned outages and the optimization of maintenance activities. This enables lower maintenance costs and improves the overall economics of nuclear power. This report primarily focuses on developing a short-term forecasting process that leverages a feature selection process to distill large volumes of heterogeneous data and predict specific equipment parameters. A variety of feature selection methods, including Shapley Additive Explanations (SHAP) and variance inflation factor (VIF), were used to select the optimal features as inputs for three ML methods: long short-term memory (LSTM) networks, support vector regression (SVR), and random forest (RF). Each combination of model and input features was used to predict a pump bearing temperature both 1 and 24 hours in advance, based on actual plant system data. The optimal inputs for the LSTM and SVR were selected using the SHAP values, while the optimal input for the RF consisted solely of the response variable itself. Each model produced similar 1-hour-ahead predictions, with root mean square errors (RMSEs) of roughly 0.006. For the 24-hour-ahead predictions, differences could be seen between LSTM, SVR, and RF, as reflected by model performances of 0.036 ± 0.014, 0.0026 ± 0, and 0.063 ± 0.004 RMSE, respectively. As big data and continuous online monitoring become more widely available, the proposed feature selection process can be used for many applications beyond the prediction of process parameters within nuclear infrastructure. This report summarizes the Fiscal Year 2021 research progress encompassing the (1) data cleaning and feature selection necessary for ML applications; (2) development of short-term forecasting models to predict future plant process parameters for both single and multiple time steps ahead; and (3) validation of the feature selection methods and short-term forecasting models given new data from different systems.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Early High-contrast Imaging Results with Keck/NIRC2-PWFS: The SR 21 Disk

High-contrast imaging of exoplanets and protoplanetary disks depends on wave front sensing and correction made by adaptive optics instruments. Classically, wave front sensing has been conducted at optical wavelengths, which made high-contrast imaging of red targets such as M-type stars or extincted T Tauri stars challenging. Keck/NIRC2 has combined near-infrared (NIR) detector technology with the pyramid wave front sensor (PWFS). With this new module we observed SR 21, a young star that is brighter at NIR wavelengths than at optical wavelengths. Compared with the archival data of SR 21 taken with the optical wave front sensing we achieved ~20% better Strehl ratio in similar natural seeing conditions. Further post-processing utilizing angular differential imaging and reference-star differential imaging confirmed the spiral feature reported by the Very Large Telescope/Spectro-Polarimetric High-contrast Exoplanet REsearch instrument polarimetric observation, which is the first detection of the SR 21 spiral in total intensity at L' band. We also compared the contrast limit of our result (10 -4 at 0.'4 and 2 × 10 -5 at 1.'0) with the archival data that were taken with optical wave front sensing and confirmed the improvement, particularly at ≤0.'5. Our observation demonstrates that the NIR PWFS improves AO performance and will provide more opportunities for red targets in the future.

79 ASTRONOMY AND ASTROPHYSICS↗

Molecular dynamics and continuum analyses of the electrokinetic zeta potential in nanostructured slit channels

This work presents a theoretical and numerical study of electrokinetic flow and the zeta potential for the case of slit channels with nanoscale surface features of dimensions comparable to the Debye length, by employing molecular dynamics simulations and continuum-level analyses. Additionally, a simple analytical model for considering the average effect of such surface features producing nanoscale roughness is proposed by employing matched asymptotic solutions for the charge density and fluid flow field, and matching conditions that satisfy electroneutrality and the Onsager reciprocal relation between the electroosmotic flow rate and streaming current. The proposed analytical model quantitatively accounts for results from molecular dynamics simulations that consider the presence of ion solvation shells and surface hydration layers. Our analysis indicates that a simultaneous knowledge of the electroosmotic and pressure-driven flow rate or streaming current can be instrumental to unambiguously determine the zeta potential in the presence of nanoscale surface features.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A new μ -high energy resolution fluorescence detection microprobe imaging spectrometer at the Stanford Synchrotron Radiation Lightsource beamline 6-2

In this report we describe a new synchrotron X-ray Fluorescence (XRF) imaging instrument with an integrated High Energy Fluorescence Detection X-ray Absorption Spectroscopy (HERFD-XAS) spectrometer at the Stanford Synchrotron Radiation Lightsource at beamline 6-2. The X-ray beam size on the sample can be defined via a range of pinhole apertures or focusing optics. XRF imaging is performed using a continuous rapid scan system with sample stages covering a travel range of 250 × 200 mm 2 , allowing for multiple samples and/or large samples to be mounted. The HERFD spectrometer is a Johann-type with seven spherically bent 100 mm diameter crystals arranged on intersecting Rowland circles of 1 m diameter with a total solid angle of about 0.44% of 4π sr. A wide range of emission lines can be studied with the available Bragg angle range of ~64.5°–82.6°. With this instrument, elements in a sample can be rapidly mapped via XRF and then selected features targeted for HERFD-XAS analysis. Furthermore, utilizing the higher spectral resolution of HERFD for XRF imaging provides better separation of interfering emission lines, and it can be used to select a much narrower emission bandwidth, resulting in increased image contrast for imaging specific element species, i.e., sparse excitation energy XAS imaging. This combination of features and characteristics provides a highly adaptable and valuable tool in the study of a wide range of materials.

47 OTHER INSTRUMENTATION↗

FY26 Mid-Year Report Self-Diagnostic Capabilities for Neutron Instruments

This year we will transfer the latest version of INCC6 with last year’s self-diagnostic features to the IAEA. In FY25 we completed the development of three automated self diagnostic features into INNC6. The completion of these features marked the final stable version of INCC 6.0 ready for release to the IAEA and other users. In the first half of the Fiscal Year 2026 we have worked with LANL’s Feynman Center and Export Control office to attain a license for exporting INCC6 to the IAEA. We have successfully attained the export license for INCC6, and contacts at the IAEA have been granted permission to receive INCC6. We are in the final stage of writing the version 6 user manual. Once this is complete, we will deliver INCC6 to the IAEA for testing.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

On the instrument-dependent appearance of ion dissociation events in atom probe tomography mass spectra

The successful application of atom probe tomography (APT) relies on the accurate interpretation of the mass spectrum (i.e. m/z histogram) from a sample. Some materials yield mass spectra that are amenable to a straightforward peak assignment/ranging, however, there are many materials that produce mass spectra with features that defy simple interpretation. One such example is Ga 2 O 3 which yields mass spectra containing several broad and difficult to interpret features. Herein, we study the GaO 2+ → O 1+ + Ga 1+ dissociation and we explain how this dissociation process gives rise to broad and previously unassigned features in the mass spectrum. Trajectory simulations are performed for the dissociation reaction utilizing realistic electrostatic models and compared to experiments using commercially available straight flight and reflectron based local electrode (LE) APT instruments. It is shown that the appearance of these features is strongly dependent on the specific design of the time-of-flight (ToF) mass analyzer. Additionally, we explore how various experimental parameters can affect the appearance of the dissociation process in the one-dimensional (1D) mass spectrum and in the two-dimensional (2D) correlation histogram. While the focus of this work is on a particular dissociation process related to Ga 2 O 3 , the understanding gained in the course of these simulations and experiments should be applicable to the interpretation of dissociation processes in other materials.

47 OTHER INSTRUMENTATION↗

The gravity extension for MCNP 6.2

Standard MCNP particle tracking takes place along straight-line trajectories from interaction point to interaction point. There is a feature within MCNP that is planned for deprecation that provides surface boundary conditions for approximating gravity for planetary cases, but this feature is not applicable to a cold neutron beam. A new extension has been developed to track particles along parabolic trajectories with a constant acceleration. MCNP contains 1st and 2nd-order surfaces as well as a special case of 4th-order surfaces for simple tori, and the intersection of parabolic trajectories with these surfaces becomes 2nd, 4th, and 8th-order equations in time, respectively. Solving these equations utilizes a fast algorithm for finding the roots of polynomials. Finally, the theory, MCNP input card, and examples of using this new feature will be discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗