Planar Doppler Velocimetry for Large-Scale Wind Tunnel Testing

Recently, Planar Doppler Velocimetry (PDV) has been shown by several laboratories to offer an attractive means for measuring three-dimensional velocity vectors everywhere in a light sheet placed in a flow. Unlike other optical means of measuring flow velocities, PDV is particularly attractive for use in large wind tunnels where distances to the sample region may be several meters, because it does not require the spatial resolution and tracking of individual scattering particles or the alignment of crossed beams at large distances. To date, demonstrations of PDV have been made either in low speed flows without quantitative comparison to other measurements, or in supersonic flows where the Doppler shift is large and its measurement is relatively insensitive to instrumental errors. Moreover, most reported applications have relied on the use of continuous-wave lasers, which limit the measurement to time-averaged velocity fields. This work summarizes the results of two previous studies of PDV in which the use of pulsed lasers to obtain instantaneous velocity vector fields is evaluated. The objective has been to quantitatively define and demonstrate PDV capabilities for applications in large-scale wind tunnels that are intended primarily for the production testing of subsonic aircraft. For such applications, the adequate resolution of low-speed flow fields requires accurate measurements of small Doppler shifts that are obtained at distances of several meters from the sample region. The use of pulsed lasers provides the unique capability to obtain not only time-averaged fields, but also their statistical fluctuation amplitudes and the spatial excursions of unsteady flow regions such as wakes and separations. To accomplish the objectives indicated, the PDV measurement process is first modeled and its performance evaluated computationally. The noise sources considered include those related to the optical and electronic properties of Charge-Coupled Device (CCD) arrays and to speckle effects associated with coherent illumination from pulsed lasers. The signal noise estimates are incorporated into the PDV signal analysis process and combined with computed scattering signals using a Mie scattering theory for polydisperse smoke particles. The relevant parameters incorporate a range of practical aerodynamic test conditions and facility sizes. The results define the optimum instrument configurations, show that the expected signal levels from a practical PDV system are sufficiently large to allow its useful application in large facilities, and show that the expected velocity measurement uncertainties are small compared to the mean velocities of interest for most subsonic, large-scale wind tunnel testing. Experimental studies using several experimental bench-top setups are then described that validate the physics of the PDV model and to calibrate its computed results. The validated model allows estimates of the uncertainties of PDV measurements and a complete definition of the PDV capabilities to be made with sufficient confidence to decide the viability of PDV for large-scale wind tunnel applications.

McKenzie, Robert L.↗

Measurement Capabilities of Planar Doppler Velocimetry in Large-Scale Wind Tunnels

Over the past few years, Planar Doppler Velocimetry (PDT) has been shown by several laboratories to offer an attractive means for measuring three-dimensional velocity vectors everywhere in a light sheet placed in a flow. Unlike some other optical means of measuring flow velocities, PDT is particularly attractive for use in large wind tunnels where distances to the sample region may be several meters, because it does not require the spatial resolution and tracking of individual scattering particles or the alignment of crossed beams at large distances. To date, demonstrations of PDT (also called Doppler Global Velocimetry by some authors) have been made either in low speed flows without quantitative comparison to other measurements, or in supersonic flows where the Doppler shift is large and its measurement is relatively insensitive to instrumental errors. Moreover, most reported applications have relied on the use of continuous-wave lasers, which limit the measurement to time-averaged velocity fields. This work summarizes the results of two previous studies of PDT in which the use of pulsed lasers to obtain instantaneous velocity vector fields is evaluated. The objective has been to quantitatively define and demonstrate PDT capabilities for applications in large-scale wind tunnels that are intended primarily for the testing of rotorcraft and subsonic aircraft at speeds typically less than 100 m/s. For such applications, the adequate resolution of low-speed flow fields requires accurate measurements of small Doppler shifts that are obtained at distances of several meters from the sample region and with a field of view that is sufficient to encompass the entire region of interest. The use of pulsed lasers provides the unique capability to obtain not only time-averaged fields, but also their statistical fluctuation amplitudes and the spatial excursions of unsteady flow regions such as wakes, separations, and rotor-tip vortices. To accomplish the objectives of these studies, the PDT measurement process was first modeled and its performance evaluated computationally. The noise sources considered included those related to the optical and electronic properties of Charge-Coupled Device (CCD) arrays and to speckle effects associated with the coherent illumination of aerosols from pulsed lasers. The signal noise estimates were incorporated into the PDT signal analysis process and combined with computed scattering signals using a Mae scattering theory for a distributed range of aerosol particle sizes. The results are used to define the necessary instrument configuration, to show that the expected signal levels from a practical PDT system are sufficiently large to allow its useful application in large facilities, and to show that the expected velocity measurement uncertainties are small compared to the mean velocities of interest for most subsonic, large-scale wind tunnel testing, Experimental studies using several bench-top setups are then described that validate the physics of the PDT model and demonstrate the ability to obtain accurate PDT measurements using procedures that are compatible with large-scale wind tunnel operations. The PDT measurement capabilities found in this study lead to the conclusion that PDT offers significant advantages compared to other means of measuring velocity fields in large-scale wind tunnels, including those operating at low speeds.

McKenzie, Robert L.↗

SCIP2 flight instrumentation specification for parameter identification: User's guide

SCIP2 which is a digital computer program that can be used to investigate the effects of instrumentation errors on the accuracy of aircraft stability and control derivatives identified from flight test data is presented. The program is based on the assumptions that the aircraft differential equations of motion are linear and consist of small perturbations about a quasisteady flight condition. It is also assumed that a Newton-Raphson optimization technique is used for identifying the estimates of the parameters. A summary of the equations which are coded in the program are included.

Taniguchi, N.↗

Determination of a third orthogonal velocity component using two rotationally displaced laser Doppler velocimeter systems.

Transformation equations are derived that may be used to determine a third orthogonal velocity component from measurements made at a common point by two rotationally displaced, two orthogonal component laser Doppler velocimeter (LDV) systems. These equations also may be used to relate velocity measurements made in a particular coordinate system to any other coordinate system. It is shown that the set of smallest angles that may be used to separate the two, two component, LDV systems is very sensitive to the relative magnitudes and directions of the individual velocity components. When the magnitudes of all velocity components are about the same, it is found that the minimum angle of separation is of the same order as the instrumental error of the LDV systems.

Farmer, W. M.↗

Precision selenodesy via differential interferometry.

Review of the first results obtained from the development and use of a new type of differential receiver designed to determine the relative locations on the lunar surface of two Apollo-deposited transmitters. This receiver has made it possible to reduce random and systematic instrumental errors to nearly negligible levels (displacement uncertainties equivalent to a few centimeters).

Counselman, C. C., III↗

Guiding of a balloon-borne coronagraph

Discussion of the guidance system of a balloon-borne coronagraph designed for IR solar corona observations at an altitude of 36 km. The coronagraph has two telescopes, measures 6 m in length, weighs 73 kg, is stabilized by a three-axis system, and has a pointing precision of plus or minus 10 sec of arc. Three torque motors are used to activate the tracking servo system of the coronagraph. An integral control system is used to prevent a permanent instrumental error. The coronagraph has been tested in two balloon missions.

Li, T.-C.↗

Lunar baselines and libration from differential VLBI observations of ALSEPs

Differential very-long-baseline interferometric observations of signals from Apollo Lunar Surface Experiment Package telemetry transmitters will yield the relative projected positions of the transmitters with uncertainty of only 1-3 m, set mainly by uncertainty of the lunar ephemeris. Noise and systematic instrumental errors which in the past affected similar observations have been reduced to the equivalent of a few centimeters on the lunar surface by the development of a new type of differential receiver. Continued observations should yield a determination of the motion of the moon about its center of mass with uncertainty less than 1 sec of selenocentric arc. Improvements (by other means) in our knowledge of the moon's orbital motion would allow a further order-of-magnitude refinement in the libration and relative position results obtainable by differential VLBI.

Counselman, C. C., III↗

Satellite radar scatterometry

Questions of air-sea interaction are considered along with the theoretical results of an analysis of radar backscatter from the ocean and experimental measurements of radar backscatter. Scatterometer design specifications have been established based on user requirements of accuracy, swath width, resolution cell size, and a 100 km grid spacing of the measurements. The instrument errors associated with the fan beam mode of operation are shown in a graph.

Swift, C. T.↗

Precision Selenodesy via Differential Very-Long-Baseline Interferometry

The technique of differential very-long baseline interferometry was used to measure the relative positions of the ALSEP transmitters at the Apollo 12, 14, 15, 16, and 17 lunar landing sites with uncertainties less than 0.005 of geocentric arc. These measurements yielded improved determinations of the selenodetic coordinates of the Apollo landing sites, and of the physical libration of the moon. By means of a new device, the differential Doppler receiver (DDR), instrumental errors were reduced to less than the equivalent of 0.001. DDRs were installed in six stations of the NASA spaceflight tracking and data network and used in an extensive program of observations beginning in March 1973.

King, R. W., Jr.↗

Flight instrumentation specification for parameter identification: Program user's guide

A set of four digital computer programs is presented which can be used to investigate the effects of instrumentation errors on the accuracy of aircraft and helicopter stability-and-control derivatives identified from flight test data. The programs assume that the differential equations of motion are linear and consist of small perturbations about a quasi-steady flight condition. It is also assumed that a Newton-Raphson optimization technique is used for identifying the estimates of the parameters. Flow charts and printouts are included.

Mohr, R. L.↗