Compact Instrument for Measuring Profile of a Light Beam

The beamviewer is an optical device designed to be attached to a charge-coupled-device (CCD) image detector for measuring the spatial distribution of intensity of a beam of light (the beam profile ) at a designated plane intersecting the beam. The beamviewer-and-CCD combination is particularly well suited for measuring the radiant- power profile (for a steady beam) or the radiant-energy profile (for a pulsed beam) impinging on the input face or emerging from the output face of a bundle of optical fibers. The beamviewer and-CCD combination could also be used as a general laboratory instrument for profiling light beams, including beams emerging through small holes and laser beams in free space.

Papanyan, Valeri↗

BIOME: An Ecosystem Remote Sensor Based on Imaging Interferometry

Until recent times, optical remote sensing of ecosystem properties from space has been limited to broad band multispectral scanners such as Landsat and AVHRR. While these sensor data can be used to derive important information about ecosystem parameters, they are very limited for measuring key biogeochemical cycling parameters such as the chemical content of plant canopies. Such parameters, for example the lignin and nitrogen contents, are potentially amenable to measurements by very high spectral resolution instruments using a spectroscopic approach. Airborne sensors based on grating imaging spectrometers gave the first promise of such potential but the recent decision not to deploy the space version has left the community without many alternatives. In the past few years, advancements in high performance deep well digital sensor arrays coupled with a patented design for a two-beam interferometer has produced an entirely new design for acquiring imaging spectroscopic data at the signal to noise levels necessary for quantitatively estimating chemical composition (1000:1 at 2 microns). This design has been assembled as a laboratory instrument and the principles demonstrated for acquiring remote scenes. An airborne instrument is in production and spaceborne sensors being proposed. The instrument is extremely promising because of its low cost, lower power requirements, very low weight, simplicity (no moving parts), and high performance. For these reasons, we have called it the first instrument optimized for ecosystem studies as part of a Biological Imaging and Observation Mission to Earth (BIOME).

Peterson, David L.↗

Relative Detectability of Iron-Bearing Phases for the Mars 2020 Sherloc Deep UV Raman Instrument: 1. Focusing on Carbonates

A deep ultraviolet (DUV) Raman and fluorescence instrument is a surface standoff instrument mounted on the robotic arm of the Mars 2020 (M2020) rover Perseverance, and it is a key element of the Scanning Habitable Environments with Luminescence for Organics and Chemicals (SHERLOC) investigation [1]. Measurement and science objectives include mineralogical and organic images (~100 μm/pixel) that map sub-millimeter spatial distributions and characterization of primary and secondary minerals, potential organics, and their interaction/alteration products. The results of data analysis pertain to understanding igneous and alteration processes on Mars through time, assessing habitability, evidencing in situ biosignatures, and, along with results from other Perseverance instruments, selecting samples to cache for Mars sample return. Acceptance of the SHERLOC investigation for the NASA M2020 mission [2] created a need for Mars-relevant DUV Raman spectra, particularly for inorganic materials [e.g., 3, 4]. As reported previously [e.g., 4, 5], phases with Fe cations as essential elements (e.g., siderite (FeCO3) and ankerite (FeCa(CO3)2) for carbonates) significantly hinder detection by DUV Raman because of intense absorption of incident and scattered DUV laser radiation by Fe cations. We report here the relative detectability of carbonates (Mg,Ca,Fe,Mn)CO3 by DUV Raman using a SHERLOC analog laboratory instrument.

R V Morris↗

Integration of NASA Research into Undergraduate Education in Math, Science, Engineering and Technology at North Carolina A&T State University

The NASA PAIR program incorporated the NASA-Sponsored research into the undergraduate environment at North Carolina Agricultural and Technical State University. This program is designed to significantly improve undergraduate education in the areas of mathematics, science, engineering, and technology (MSET) by directly benefiting from the experiences of NASA field centers, affiliated industrial partners and academic institutions. The three basic goals of the program were enhancing core courses in MSET curriculum, upgrading core-engineering laboratories to compliment upgraded MSET curriculum, and conduct research training for undergraduates in MSET disciplines through a sophomore shadow program and through Research Experience for Undergraduates (REU) programs. Since the inception of the program nine courses have been modified to include NASA related topics and research. These courses have impacted over 900 students in the first three years of the program. The Electrical Engineering circuit's lab is completely re-equipped to include Computer controlled and data acquisition equipment. The Physics lab is upgraded to implement better sensory data acquisition to enhance students understanding of course concepts. In addition a new instrumentation laboratory in the department of Mechanical Engineering is developed. Research training for A&T students was conducted through four different programs: Apprentice program, Developers program, Sophomore Shadow program and Independent Research program. These programs provided opportunities for an average of forty students per semester.

Monroe, Joseph↗

The NASA Facility for Astromaterials Research at the Johnson Space Center – A National Laboratory for Planetary Research

The Astromaterials Research and Exploration Science (ARES) Division at the NASA Johnson Space Center houses a unique combination of laboratories, instruments, infrastructure, technical ex-pertise, and other assets for conducting broad-based world-class planetary research. These facilities have been accessed for decades by hundreds of external scientists, including faculty, post-docs, students, and interns, most at no cost and on a collaborative basis. With funding through NASA’s Planetary Science Enabling Facilities (PSEF) program, we have estab-lished the NASA Facility for Astromaterials Research (NFAR) to expand access to and enhance these labora-tories for a diverse and inclusive external user base, thus maximizing the science return from research funded by R&A programs in NASA’s Planetary Sci-ence Division (PSD). NFAR enables cutting edge planetary sample analyses, making new scientific dis-coveries possible, in addition to training the next-generation of planetary scientists. NFAR laboratories are co-located with JSC Curation that houses all NASA-controlled astromaterials collections, thus ena-bling direct access to both research and curation exper-tise, to facilitate specialized sample handling and anal-ysis of allocated samples (from JSC and other sample collections) to PIs, particularly those affiliated with institutions that historically have limited or no access to in-house analytical or experimental facilities.

J Filiberto↗

Preparation of thin polymer films for infrared reaction rate studies

Procedure for preparing thin films for infrared spectrophotometric analysis involves pressing of a neat mixture of reactants between nonreactive thin polymer films with noninterfering absorption bands. Pressing is done under a pressure that gives desirable thickness. Following this process, the film sandwich is cut to accommodate the laboratory instrument.

Garrard, G. G.↗

Specular reflectance of aqueous solutions.

Description of two laboratory instruments for measuring the specular reflectance of aqueous solutions. The instruments are an organic-dye-laser spectrophotometer for the 360- to 650-nm wavelength region and a reflectometer accessory for a Perkin-Elmer E-system spectrophotometer which will operate in the 0.2- to 20-micron wavelength region. The reflectometer accessory has been used to measure the relative infrared specular reflectance in limited spectral regions for aqueous solutions of NaCl, K2SO4, ZnSO4, (NH4)2SO4, and NH4H2PO4 with radiant flux incident at about 70 deg and polarized perpendicular to the plane of incidence. The laser spectrometer has been used to measure the absolute reflectance of aqueous solutions of NaCl in the wavelength region from 575 to 610 nm for light incident at angles of about 60, 65, and 70 deg and polarized parallel to the plane of incidence.

Querry, M. R.↗

Evaluation of electrostatic charge effects on the data processing system and the orbiter communication and tracking receivers

An analysis of radiated interference test results obtained from frictionally charged Orbiter TPS tile was presented. The tests included the measurement of noise pick-up by Orbiter S-band, L-band, C-band, and Ku-band antennas located beneath the tiles in a manner simulating their installation on Orbiter. In addition, the radiated field characteristics resulting from the static discharge was determined. The results are analyzed as to their effect on data bus equipment and on Orbiter Communications and Tracking (C&T) receivers. It was concluded that the radiated interference should have no effect on MDM's. However the CPU, IOP and PMU enclosures require some minor modification to assure immunity from P-static interference. Orbiter antenna tests indicate that the S-band receiver should not be affected by P-static noise. The TACAN and Radar Altimeter performance appears to be adequate but with a small margin. MSBLS performance is uncertain because laboratory instrumentation cannot approach the MSBLS sensitivity.

Lawton, R. M.↗

Performance tests of two precision attitude determination systems

Results of laboratory performance tests of two satellite attitude determination systems are given. One system employed a strapdown star tracker and gyro assembly, the other a single axis, gimballed star tracker and a gyro assembly. The laboratory tests simulated those orbit conditions which would be experienced on a three axis stabilized, earth pointed satellite in geosynchronous orbit. A ground-fixed laboratory test was performed in which system axes remained stationary in the laboratory coordinates while revolving star beams stimulated the star trackers. The laboratory instrumentation techniques used to meet the stringent accuracy requirements are described. Results are presented which show both systems met the performance goal of 3.6 arc seconds. Comparative analyses of both systems are also discussed.

Mcaloon, K. J.↗

Controlling a wide range of flow rates

Servo-operated valve and two flowmeters allow accurate control over 1,900:1 flow-rate range. It was developed as part of laboratory instrument for measuring properties of confined fluids under conditions analogous to those encountered in deep drilling operations.

Perkins, G. S.↗

An automatically-shifted two-speed transaxle system for an electric vehicle

An automatic shifting scheme for a two speed transaxle for use with an electric vehicle propulsion system is described. The transaxle system was to be installed in an instrumented laboratory propulsion system of an ac electric vehicle drive train. The transaxle which had been fabricated is also described.

Gordon, H. S.↗

A gas chromatographic air analyzer fabricated on a silicon wafer

A miniature gas analysis system has been built based on the principles of gas chromatography (GC). The major components are fabricated in silicon using photolithography and chemical etching techniques, which allows size reductions of nearly three orders of magnitude compared to conventional laboratory instruments. The chromatography system consists of a sample injection valve and a 1.5-m-long separating capillary column, which are fabricated on a substrate silicon wafer. The output thermal conductivity detector is separately batch fabricated and integrably mounted on the substrate wafer. The theory of gas chromatography has been used to optimize the performance of the sensor so that separations of gaseous hydrocarbon mixtures are performed in less than 10 s. The system is expected to find application in the areas of portable ambient air quality monitors, implanted biological experiments, and planetary probes.

Terry, S. C.↗

A comparison of high-temperature flare models with observations and implications for the low-temperature flare

EUV data from the Harvard College Observatory and Naval Research Laboratory instruments on board the Skylab Apollo telescope mount, together with SOLRAD 9 X-ray data, are analyzed in order to empirically deduce the variation of emission measure with temperature in the atmosphere of a number of solar flares. A 'mean' differential emission measure profile Q(T) for a flare is constructed which is then compared with the profile predicted by a number of theoretical models. It is found that realistic flare models must include both conductive and radiative terms in the energy equation, and that hydrodynamic terms may be important at low temperatures. The implications of the results obtained are discussed for flare models in general and it is shown that the inclusion of the conductive term into models which have hitherto neglected it can perhaps resolve some of the observational difficulties with such models.

Machado, M. E.↗

Observations of large fluxes of He/+/ in the solar wind following an interplanetary shock

Los Alamos Scientific Laboratory instrumentation on Imp 7 has detected large fluxes of He(+) within that volume of solar wind plasma believed to be the solar ejecta driving the interplanetary shock wave disturbance of July 29, 1977. The very high He(+)/He(++) abundance ratio of 0.3 measured during this event suggests that this was solar prominence material only partially ionized by its passage through the corona.

Gosling, J. T.↗

Solar wind iron abundance variations at speeds greater than 600 km/s, 1972-1976

An analysis has been conducted of the Fe/H ratios in the peaks of high-speed streams during the decline of solar cycle 20 and the following minimum (October 1972-December 1976). The response of the 50- to 200-keV ion channel of The Johns Hopkins University Applied Physics Laboratory energetic particle experiments (EPE) on IMP 7 and 8, which is (in the absence of energetic ions) dominated by solar wind iron ions at high solar wind speeds (V approximately equal to or greater than 600 km/s) as inferred from calibrations of flight spare detectors. The conducted Fe measurements have been compared with solar wind H and He parameters from the Los Alamos National Laboratory instruments on the same spacecraft. In general, the Fe distribution parameters (bulk velocity, flow direction, temperature) are found to be similar to the He parameters. Although the average Fe/H ratios found in the peaks of many steady high-speed streams agree within observational uncertainties with the nominal coronal ratio of 4.7 x 10 to the -5th, abundance variations of a factor of up to 6 are obtained across a given coronal-hole associated high-speed stream. There are, as well, a factor of 2 variations between stream-averaged abundances for recurrent high-speed streams emanating from different coronal holes occurring on the sun on the same solar rotation. Flare-related solar wind flows sometimes show Fe/H ratios enhanced by factors of 4-5 more than in coronal-hole associated, quiet-time streams, while in one case the Fe/H enhancement was still observable one rotation after the flare activity. Over the period 1973-1976, a steady decrease in the average quiet time Fe/H ratio by a factor of approximately 4 is measured on both IMP 7 and 8.

Mitchell, D. G.↗

New identifications of Fe XVII spectral lines in solar flares

The identifications of Fe XVII transitions between the 2s(2)2p(5)3s, 3p, and 3d configurations published by Jupen (1984) are reviewed. The review is based on examining spectroheliograms of solar flares obtained by a Naval Research Laboratory instrument on Skylab (S082-A). Agreement is obtained with the majority of identifications given by Jupen, but different wavelengths are found for a few of the lines. The relative intensities of the lines are qualitatively in agreement with calculations. A broad line at 1153.20 A is identified with the 2p(5)3s(3)P(0)-2p(5)3s(3)P1 forbidden transition of Fe XVII. This line was found in flare spectra obtained by the NRL slit spectrograph on Skylab (S082-B).

Feldman, U.↗

Continuous flow electrophoresis system experiments on shuttle flights STS-6 and STS-7

A space continuous flow electrophoresis system (CFES) was developed that would incorporate specific modifications to laboratory instruments to take advantage of weightlessness. The specific objectives were to use a model sample material at a high concentration to evaluate the continuous flow electrophoresis process in the CFES instrument and compare its separation resolution and sample throughput with related devices on Earth and to expand the basic knowledge of the limitations imposed by fluid flows and particle concentration effects on the electrophoresis process by careful design and evaluation of the space experiment. Hemoglobin and polysaccharide were selected as primary samples. The results from space show a large band spread of the high concentration of the single species of hemoglobin that was due to the mismatch of electrical conductivity between the sample and the buffer. On STS-7 the major objective was to evaluate the influence of the electrical properties of the sample constituents on the resolution of the CFES. As expected, the polystyrene latex microspheres dispersed in a solution with 3 times the electrical conductivity of the curtain buffer separated with a larger band spread than in the 2nd experiment.

Snyder, Robert S.↗

Imaging and nondispersive spectroscopy of soft X rays using a laboratory X-ray charge-coupled-device system

This paper describes the design and performance of a laboratory instrument for imaging and nondispersive spectroscopy of soft X-rays (300 eV to 10 keV) utilizing a virtual-phase CCD. This instrument has achieved a spatial resolution of 22 microns (limited by pixel size) with an overall array area of 584 x 390 pixels. It has achieved an energy resolution of about 140 eV FWHM for single-pixel Fe-55 X-ray events (5.9 keV) with the CCD operated at -30 C. The CCD has been operated in photon-counting mode at room temperature, and X-ray spectra with an energy resolution of about 450 eV at 5.9 keV have been obtained. The low energy X-ray sensitivity of the CCD also has been demonstrated by detecting carbon K-alpha X-rays (277eV).

Luppino, Gerard A.↗