Miniature Piezoelectric Shaker Mechanism for Autonomous Distribution of Unconsolidated Sample to Instrument Cells

To perform in-situ measurements on Mars or other planetary bodies many instruments require powder produced using some sampling technique (drilling/coring) or sample processing technique (core crushing) to be placed in measurement cells. This usually requires filling a small sample cell using an inlet funnel. In order to minimize cross contamination with future samples and ensure the sample is transferred from the funnel to the test cell with minimal residual powder the funnel is shaken. The shaking assists gravity by fluidizing the powder and restoring flow of the material. In order to counter cross contamination or potential clogging due to settling during autonomous handling a piezoelectric shaking mechanism was designed for the deposition of sample fines in instrument inlet funnels. This device was designed to be lightweight, consume low power and demonstrated to be a resilient solid state actuator that can be mechanically and electrically tuned to shake the inlet funnel. In the final design configuration tested under nominal Mars Ambient conditions the funnel mechanism is driven by three symmetrically mounted piezoelectric flexure actuators that are out of the funnel support load path. The frequency of the actuation can be electrically controlled and monitored and mechanically tuned by the addition of tuning mass on the free end of the actuator. Unlike conventional electromagnetic motors these devices are solid state and can be designed with no macroscopically moving parts. This paper will discuss the design and testing results of these shaking mechanisms.

powder movement↗

Testing Devices Garner Data on Insulation Performance

To develop a test instrument that could garner measurements of the thermal performance of insulation under extreme conditions, researchers at Kennedy Space Center devised the Cryostat 1 and then Cryostat 2. McLean, Virginia-based QinetiQ North America licensed the technology and plans to market it to organizations developing materials for things like piping and storage tank insulation, refrigeration, appliances, and consumer goods.

Source record↗

Science Instrument Sensitivities to Radioisotope Power System Environment

Radioisotope Power Systems (RPS) have been and will be enabling or significantly enhancing for many missions, including several concepts identified in the 2011 Planetary Science Decadal Survey. Some mission planners and science investigators might have concerns about possible impacts from RPS-induced conditions upon the scientific capabilities of their mission concepts. To alleviate these concerns, this paper looks at existing and potential future RPS designs, and examines their potential radiation, thermal, vibration, electromagnetic interference (EMI), and magnetic fields impacts on representative science instruments and science measurements. Radiation impacts from RPS on science instruments are of potential concern for instruments with optical detectors and instruments with high-voltage electronics. The two main areas of concern are noise effects on the instrument measurements, and long-term effects of instrument damage. While RPS by their nature will contribute to total radiation dose, their addition for most missions should be relatively small. For example, the gamma dose rate from one Multi-Mission Radioisotope Thermoelectric Generator (MMRTG) would be an order of magnitude lower than the environmental dose rate at Mars, and would have a correspondingly lower contribution to instrument noise and to any permanent damage to payload sensors. Increasing the number of General Purpose Heat Source (GPHS) modules used in an RPS would be expected to increase the generated radiation proportionally; however, the effect of more GPHS modules is mitigated from a strictly linear relationship by self-shielding effects. The radiation field of an RPS is anisotropic due to the deviation of the modules from a point-source-geometry. For particularly sensitive instruments the total radiation dose could be mitigated with separation or application of spot shielding. Though a new, higher-power RPS could generate more heat per unit than current designs, thermal impact to the flight system could be mitigated with shading and pointing if required by the mission. Alternatively, excess heat could prove beneficial in providing needed heat to spacecraft components and instruments in some thermal environments. Vibration for a new higher-power Stirling Radioisotope Generator (SRG) would be expected to be similar to the recent Advanced Stirling Radioisotope Generator (ASRG) design. While vibration should be low, it must be considered and addressed during spacecraft and instrument design. EMI and magnetic fields for new RPS concepts are expected to be low as for the current RPS, but must be considered and addressed if the mission includes sensitive instruments such as magnetometers. The assessment conducted for this paper focused on orbiter instrument payloads for two representative mission concepts- a Titan Saturn System Mission (TSSM) and a Uranus Orbiter and Probe (UOP)-since both of these Decadal Survey concepts would include many diverse instruments on board. Quick-look design studies using notional new RPS concepts were carried out for these two mission concepts, and their specific instrument packages were analyzed for their interactions with new RPS designs. The original Decadal Survey TSSM and UOP concepts did not have complete instrument performance requirements so typical measurement requirements were used where needed. Then, the general RPS environments were evaluated for impacts to various types of instruments. This paper describes how the potential impacts of the RPS on science instruments and measurements were assessed, which impacts were addressed, proposed mitigation strategies against those impacts, and provides an overview of future work.

RPS↗

In-Lab Rapid Analytical Detection of Lunar Volatiles By Universal Gas Analyzer With Comparison to GC-MS System

Introduction: The curation of permanently shadowed regions (PSRs) [1] on the lunar surface is centered around studies based upon the observed volatiles from the LCROSS mission [2]. The rapid detection of important volatile gases and vapors present in planetary bodies and Astromaterials by a standalone analytical device is an area of intense research interest in our group and Planetary Exploration & Astromaterials Research Laboratory (PEARL) facility and this work is relevant to the future preparation of viable lunar simulants for testing curation efforts down the road. The groundbreaking results obtained from the LCROSS Mission [2] open the requirements for the direct detection of volatiles present in regolith materials collected from the lunar surface. The mass spectrometry of volatile chemicals is a general technique that utilizes a set of instruments that creates charged ions from a gaseous chemical species and measures the intensities vs. mass-to-charge ratio (m/z) [3]. In this context, we discuss in-lab experimental results and procedures for rapid qualitative analysis of main LCROSS volatiles (water, H2S, NH3, CO2, and CH3OH) by a Universal Gas Analyzer (UGA) instrument. Additionally, the instrument performance was evaluated by measuring the isotopic abundance ratio of atmospheric Ar-40 to Ar-36 present in room air since, argon is a relevant gas in planetary studies as it can provide an insight and reference point to isotope studies [4]. Additional, cross comparisons were attempted and made between the two instruments to develop a robust analytical technique by comparing mass spectral data for H2S headspace samples with a Trace-1310/ ISQ 7000 (ThermoFisher Scientific.) GC-MS system. Background: The benchtop UGA System is equipped with an SRS UGA 300 quadrupole mass spectrometer designed and built by Stanford Research Systems [5]. This system can be configured for several types of gaseous chemical analysis. The inlet line continuously samples gases at low flow rates (several milliliters per minute) through a capillary limiting the intake pressure making the instrument ideal for online analysis of select gases and/or room atmosphere. Moreover, in our current UGA system, a change in composition at the inlet can be detected in about 200 milliseconds and a complete spectrum is acquired (for a range of 1-100 amu) in under 45 sec with masses measured at rates up to 25 msec per point [5]. This system provides a quick upstream analytical data that we can then compare to results obtained by our GC-MS system. Sample Preparation: Small volume (2-4 mL) of analyte sample was taken in a 10 mL glass vial and sealed with a crimped cap and purged with pure Ar or N2 gas to displace air from the top. The headspace sample was scanned by the UGA instrument at analog, histogram, and pressure vs. time modes. The isotopic abundance ratio for 40Ar-to-36Ar was estimated by measuring partial pressure vs. time scans and setting the mass at 40 and 36 respectively. Results and Discussions: In this work, we have investigated the applicability of the UGA system by qualitative analysis of a series of LCROSS volatiles measured individually. Fig. 1 demonstrates a set of vertically offset spectra for the partial pressures measured as a function of mass-to-charge (m/z) ratios. The average acquisition time for each spectrum was less than a minute suggesting that the UGA system is ideal for quick analysis of geochemical volatiles. For the cross-comparison, we analyzed an H2S headspace sample by a Trace-1310/ISQ-7000 system and compared mass spectral data with previously measured UGA histogram scan data (Fig. 2). In both cases, major peak positions are the same, however, the intensities of fragment ions ([1H132S]+ and [32S]+) are higher for UGA suggesting that the fragment ionization process is stronger in UGA compared to that of GC-MS. To investigate how the integrated area under each chromatogram varies with the headspace sample volume, a set of five H2S headspace samples with increasing volumes was analyzed by the GC-MS system (Fig. 3, inset). A small volume (e.g., 200 to 1000 µL) of H2S/H2O vapor was withdrawn from a 20 mL stock sample vial containing ~5 mL of 0.4% H2S in water by a gas-tight syringe and added to another 20 mL vial filled with argon and analyzed by the GC-MS system. Finally, the UGA detector sensitivity was evaluated by calculating the atmospheric 40Ar-to-36Ar isotopic abundance ratio in room air by running a partial pressure vs. time scan with setting the atomic mass at 40, and 36. Fig. 4(a) shows a ~25 min duration “P vs. time” scan for 40Ar (plot for 36Ar is not shown). The partial pressure values (~100 points) were corrected by subtracting the corresponding background pressure value for 37Ar and utilized to calculate 40Ar-to-36Ar isotopic abundance ratios as shown by Fig. 4b. The average isotopic abundance ratio is ~306 with a 2*STDEV ~13. This abundance ratio is significantly close to the previously reported value of 298.56 [6] and the ratio obtained by our GC-MS system (303 for a UHP grade Ar sample). Conclusions: Our study strongly evidenced that the benchtop UGA system is a valuable analytical tool for the detection of major LCROSS volatiles. The rapid scanning capability, the inexpensiveness of the whole system, and impressive detection sensitivity prove its worthiness as an essential device for advanced geochemical applications. Moreover, cross comparisons with the GC-MS provide important bridges into advanced curatorial efforts into the future. References: [1] Bickel, V.T., et al. (2021) Nat Commun 12, 5607. [2] Colaprete, A., et al. (2010) Science, 330, 463-468. [3] Glavin, D. P. et al. (2012) 2012 IEEE Aerospace Conference, 1-11. [4] Willett, C. D., et al. (2022) Geochimica et Cosmochimica Acta 329, 119-134. [5] Operation Manual and Programming Reference. (2018) Universal gas Analyzers, Stanford Research Systems. [6] Lee, J. Y., et al. (2006) Geochimica et Cosmochimica Acta 70, 4507–4512. Notes: (4 figures are attached with text as shown by the attached file)

Curation↗

Space Based Observations of Coronal Cavities in Conjunction with the Total Solar Eclipse of July 2010

In conjunction with the total solar eclipse on July 11, 2010 we coordinated a campaign between ground and space based observations. Our specific goal was to augment the ground based measurement of corona) prominence cavity temperatures made using iron lines in the IR (Habbal et al. 2010 ApJ 719 1362) with measurements performed by space based instruments. Included in the campaign were Hinode/EIS, XRT and SOT, PROBA2/SWAP, SDO/AIA, SOHO/CDS and STEREO/SECCHI/EUVI, in addition to the ground based IR measurements. We plan to use a combination of line ratio and forward modeling techniques to investigate the density and temperature structure of the cavities at that time.

Kucera, T. A.↗

Autonomous Navigation of a Lunar Relay Using GNSS and Other Measurements

NASA’s Lunar Communications Relay and Navigation Services (LCRNS) project will establish a relay constellation at the Moon to provide the south pole region with communications and position, navigation, and time (PNT) services. These services will require highly accurate knowledge of position, velocity, and time (PVT) for each relay. This paper explores one approach for performing onboard PVT estimation, the LCRNS PNT Instrument (LPI). This paper considers different configurations of the instrument, specifically different measurement types and clocks, and the resulting navigation performance. Simulation results are first shown for an instrument configuration that uses GPS pseudorange and Doppler measurements with a highly sensitive GPS receiver (i.e., an acquisition and tracking threshold of 23 dB-Hz) and a chip-scale atomic clock (CSAC). The importance of Doppler, clock quality, receiver sensitivity, and optical navigation is examined through comparison of these results to other instrument configurations. Clock quality (i.e., stability) is the strongest determinant of achievable performance, and the inclusion of GPS Doppleralso has a significant effect. Finally, simulation results are compared to two laboratory tests: first a case that includes GPS receiver hardware in the loop, then a case that includes optical navigation and filter flight software in the loop. These agreeclosely with the simulation results and provide evidence the simulation is accurately modeling the instrument under development.

Benjamin W Ashman↗

Production of Flight Instruments for Multi-Satellite Constellations

Recent National Academy of Science Decadal Surveys in space and Earth-science have called for simultaneous, distributed multi-point measurements in and from space, requiring constellations of small spacecraft. Small satellites have demonstrated their utility for enabling high-quality science measurements and observations. NASA missions have leveraged advances in sensor miniaturization, technology innovations, and new small satellite mission architectures to enable meaningful measurement-based scientific investigations that operate on small satellites and that are responsive to science objectives described in National Academy of Science Decadal Surveys. The advent of high capability small spacecraft enables consideration of science missions involving multiple small spacecraft, constellations of a few or many for simultaneous distributed in situ observations or remote observations from a variety of viewpoints. The central challenge for fielding instrumented space-flight constellations is to provide the required multiple sets of fully verified and calibrated instrument hardware, software, and operational processes from within a one-off project-based scientific space flight culture. Although there are numerous commercial entities providing “off-the shelf” spacecraft and avionics, the challenge lies in the multi-unit production of the uniquely targeted instrumentation necessary to perform the specific measurements required for a particular science investigation. Traditionally, the cost of such instrumentation has represented a significant portion of the hardware cost for a mission and posed the highest risk area for implementation. A shift in paradigm from large science platforms to constellations of smaller satellites drives the challenge to build instruments in a quasi-production environment. This paper describes key aspects of, and challenges encountered in the development program for the successful production of instruments for the Fast-Plasma Investigation (FPI) instrument suite of 64 flight plasma spectrometers and supporting electronics on the NASA Magnetospheric Multiscale (MMS) 4 satellite constellation mission. Although the MMS mission was not composed of small satellites, there are key aspects of the instrument production that apply directly to constellations of small satellites.

Arthur D Jacques↗

Production of Flight Instruments for Multi-Satellite Constellations

Recent National Academy of Science Decadal Surveys in space and Earth-science have called for simultaneous, distributed multi-point measurements in and from space, requiring constellations of small spacecraft. Small satellites have demonstrated their utility for enabling high-quality science measurements and observations. NASA missions have leveraged advances in sensor miniaturization, technology innovations, and new small satellite mission architectures to enable meaningful measurement-based scientific investigations that operate on small satellites and that are responsive to science objectives described in National Academy of Science Decadal Surveys. The advent of high capability small spacecraft enables consideration of science missions involving multiple small spacecraft, constellations of a few or many for simultaneous distributed in situ observations or remote observations from a variety of viewpoints. The central challenge for fielding instrumented space-flight constellations is to provide the required multiple sets of fully verified and calibrated instrument hardware, software, and operational processes from within a one-off project-based scientific space flight culture. Although there are numerous commercial entities providing “off-the shelf” spacecraft and avionics, the challenge lies in the multi-unit production of the uniquely targeted instrumentation necessary to perform the specific measurements required for a particular science investigation. Traditionally, the cost of such instrumentation has represented a significant portion of the hardware cost for a mission and posed the highest risk area for implementation. A shift in paradigm from large science platforms to constellations of smaller satellites drives the challenge to build instruments in a quasi-production environment. This paper describes key aspects of, and challenges encountered in the development program for the successful production of instruments for the Fast-Plasma Investigation (FPI) instrument suite of 64 flight plasma spectrometers and supporting electronics on the NASA Magnetospheric Multiscale (MMS) 4 satellite constellation mission. Although the MMS mission was not composed of small satellites, there are key aspects of the instrument production that apply directly to constellations of small satellites.

Arthur D Jacques↗

Heat transfer and pressure measurements for the SSME fuel-side turbopump

A measurement program is currently underway at the Calspan-UB Research Center (CUBRC) which utilizes the Rocketdyne two-state fuel-side turbine with the engine geometric configuration reproduced. This is a full two-state turbine for which the vane rows and the blades are the engine hardware currently used on the Space Shuttle turbopump. A status report is provided for the experimental program and a description of the instrumentation and the measurements to be performed. The specific items that will be illustrated and described are as follows: (1) the gas flow path, (2) the heat-flux instrumentation, (3) the surface-pressure instrumentation, (4) the experimental conditions for which data will be obtained, and (5) the specific measurements that will be performed.

Dunn, Michael G.↗

Calibration for the SAGE III/EOS instruments

The calibration plan for the SAGE III instruments for maintaining instrument performance during the Earth Observing System (EOS) mission lifetime is described. The SAGE III calibration plan consists of detailed preflight and inflight calibration on the instrument performance together with the correlative measurement program to validate the data products from the inverted satellite measurements. Since the measurement technique is primarily solar/lunar occultation, the instrument will be self-calibrating by using the sun as the calibration source during the routine operation of the instrument in flight. The instrument is designed to perform radiometric calibration of throughput, spectral, and spatial response in flight during routine operation. Spectral calibration can be performed in-flight from observation of the solar Fraunhofer lines within the spectral region from 290 to 1030 nm wavelength.

Chu, W. P.↗

Shuttle flight pressure instrumentation: Experience and lessons for the future

Flight data obtained from the Space Transportation System orbiter entries are processed and analyzed to assess the accuracy and performance of the Development Flight Instrumentation (DFI) pressure measurement system. Selected pressure measurements are compared with available wind tunnel and computational data and are further used to perform air data analyses using the Shuttle Entry Air Data System (SEADS) computation technique. The results are compared to air data from other sources. These comparisons isolate and demonstrate the effects of the various limitations of the DFI pressure measurement system. The effects of these limitations on orbiter performance analyses are addressed, and instrumentation modifications are recommended to improve the accuracy of similar fight data systems in the future.

Siemers, P. M., III↗

Personality based clusters as predictors of aviator attitudes and performance

The feasibility of identification of personality-based population clusters was investigated along with the relationships of these subpopulations to relevant attitude and performance measures. The results of instrumental and expressive personality tests, using the Personal Characteristics Inventory (PCI) test battery and the Cockpit Management Attitudes Questionnaire, suggest that theoretically meaningful subpopulations exist among aviators, and that these groupings are useful in understanding of personality factors acting as moderator variables in the determination of aviator attitudes and performance. Out of the three clusters most easily described in terms of their relative elevations on the PCI subscales ('the right stuff', the 'wrong stuff', and the 'no stuff'), the members of the right stuff cluster tended to have more desirable patterns of responses along relevant attitudinal dimensions.

Gregorich, Steve↗

ICESat-2/ATLAS at 4 Years: Instrument Performance and Projected Life

NASA’s ICESat-2 mission launched in September 2018 carrying a single instrument, the Advanced Topographic Laser Altimeter System (ATLAS). ATLAS uses a high-repetition-rate, low-pulse-energy laser with its output split into six beams and a photon-counting receiver to measure Earth surface elevation with centimeter-level precision, repeating its ground track every 91 days. During more than four years of on-orbit operation, ATLAS has met or exceeded its lifetime and performance requirements. We present performance measurements, trends and projections for several instrument parameter, including transmitted laser pulse energy, receiver sensitivity, the instrument’s impulse response, transmitter/receiver alignment, dead-time behavior, and elevation measurement performance. The laser energy setting was increased in September 2023, for the first time, to maintain ranging performance at its early mission level. The trends in instrument parameters indicate capability to continue on-orbit operation of ATLAS for many years into the future.

Anthony J. Martino↗

Testing Instrument for Flight-Simulator Displays

Displays for flight-training simulators rapidly aligned with aid of integrated optical instrument. Calibrations and tests such as aligning boresight of display with respect to user's eyes, checking and adjusting display horizon, checking image sharpness, measuring illuminance of displayed scenes, and measuring distance of optical focus of scene performed with single unit. New instrument combines all measurement devices in single, compact, integrated unit. Requires just one initial setup. Employs laser and produces narrow, collimated beam for greater measurement accuracy. Uses only one moving part, double right prism, to position laser beam.

Haines, Richard F.↗

A new concept for a Titan atmospheric probe

Since the Voyager 1 close-pass observations of Titan, scientific interest in the nature and composition of the atmosphere and surface of Titan has increased greatly. This enhanced interest has led to the study of mission options to the Saturnian system with a principal goal of depositing a probe into the atmosphere of Titan. Such a probe could carry instrumentation to perform in situ measurements of the structure and composition of the atmosphere and clouds and of the morphology and composition of the surface. Previous studies have examined the possibility of modifying, in a minimal way, the Galileo probe currently being prepared for an atmospheric sampling mission to Jupiter. The purpose of this paper is to report the results of a study of probe-system concepts optimized for the Titan mission. The scientific rationale for such a mission to Titan is discussed and instruments to accomplish the scientific goals are indicated. Probe systems compatible with those goals and instruments are described, and the associated development costs for each are discussed.

Swenson, B. L.↗

Air-sampling inlet contamination by aircraft emissions on the NASA CV-990 aircraft

Results of an experimental investigation of the contamination of air sampling inlets by aircraft emissions from the NASA CV-990 research aircraft are presented. This four-engine jet aircraft is a NASA facility used for many different atmospheric and meteorological experiments, as well as for developing spacecraft instrumentation for remote measurements. Our investigations were performed to provide information on which to base the selection of sampling locations for a series of multi-instrument missions for measuring tropospheric trace gases. The major source of contamination is the exhaust from the jet engines, which generate many of the same gases that are of interest in atmospheric chemistry, as well as other gases that may interfere with sampling measurements. The engine exhaust contains these gases in mixing ratios many orders of magnitude greater than those that occur in the clean atmosphere which the missions seek to quantify. Pressurized samples of air were collected simultaneously from a scoop located forward of the engines to represent clean air and from other multiport scoops at various aft positions on the aircraft. The air samples were analyzed in the laboratory by gas chromatography for carbon monoxide, an abundant combustion by-product. Data are presented for various scoop locations under various flight conditions.

Condon, E. P.↗

Optical Testing Using Portable Laser Coordinate Measuring Instruments

High precision, portable coordinate measuring instruments (CMI) such as laser radars (LR) and laser trackers (LT) have been used for optical system alignment and integration. The LRs ability to perform a non-contact scan of surfaces was previously utilized to characterize large spherical and aspheric mirrors. In this paper, we explore the use of a CMI as an accurate, fast, robust, and non-contact tool for prescription characterization of powered optical surfaces. Using Nikons MV-224350 LR and Leicas Absolute Tracker AT401402 instruments, proof of concept measurements were performed to characterize a variety of optical components by measuring the actual and apparent, or equivalently the direct and through (DT), coordinates of calibrated metrology targets. Custom macros in metrology software and other data reduction code were developed to compute surface-ray intercepts and surface slopes from the DT shots. The calculated data is fit to an aspheric surface formula to obtain the optimum prescription. The results were compared to the nominal parameters and were crosschecked using LR scans or other approaches. We discuss potential applications across the fields of optical component fabrication and system alignment and testing.

Khreishi, M.↗