Search NASA⌕ Search

SEARCH · Search NASA

Results for “INTENSIFIER TUBE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

67 records · Page 4

Techniques for Surface-Temperature Measurements and Transition Detection on Projectiles at Hypersonic Velocities--Status Report No. 2

The latest developments in a research effort to advance techniques for measuring surface temperatures and heat fluxes and determining transition locations on projectiles in hypersonic free flight in a ballistic range are described. Spherical and hemispherical titanium projectiles were launched at muzzle velocities of 4.6-5.8 km/sec into air and nitrogen at pressures of 95-380 Torr. Hemisphere models with diameters of 2.22 cm had maximum pitch and yaw angles of 5.5-8 degrees and 4.7-7 degrees, depending on whether they were launched using an evacuated launch tube or not. Hemisphere models with diameters of 2.86 cm had maximum pitch and yaw angles of 2.0-2.5 degrees. Three intensified-charge-coupled-device (ICCD) cameras with wavelength sensitivity ranges of 480-870 nm (as well as one infrared camera with a wavelength sensitivity range of 3 to 5 microns), were used to obtain images of the projectiles in flight. Helium plumes were used to remove the radiating gas cap around the projectiles at the locations where ICCD camera images were taken. ICCD and infrared (IR) camera images of titanium hemisphere projectiles at velocities of 4.0-4.4 km/sec are presented as well as preliminary temperature data for these projectiles. Comparisons were made of normalized temperature data for shots at approx.190 Torr in air and nitrogen and with and without the launch tube evacuated. Shots into nitrogen had temperatures ~6% lower than those into air. Evacuation of the launch tube was also found to lower the projectile temperatures by approx.6%.

Bogdanoff, D. W.↗

Test results on intensified charge coupled devices

CCD imaging arrays were evaluated for a photon counting astronomical sensor. Results show noise corresponding to less than 100 rms electrons and gains of approximately 1000 at 10kV accelerating voltage (greater than 5000 at 25kV). Measured charge transfer efficiencies are in excess of 0.9999, signal saturation levels are as high as 990000 electrons per pixel and peak quantum efficiencies are greater than 75%. Successful proximity focussed intensified charge coupled devices (ICCD) have been fabricated, although problems still exist with contamination and possible structural failures in the CCD's during tube manufacture.

Williams, J. T.↗

Electrooptical scanning of film

Scan-in scan-out flying spot scanning system recognizes three different levels of transmissivity within a frame. It selectively acts on these levels either to intensify the illumination or to extend the duration of the illuminating spot to any picture element. Thus it improves the ratio of signal to tube noise in the cameras output.

Billingsley, F. C.↗

Carbon suboxide polymer, an explanation for the wave of darkening on Mars

The carbon suboxide thermal polymer or its irradiated product is affected by water vapor. The polymerized carbon suboxide simulates the Martian wave of darkening on the inner wall of a glass tube when humidified by passage of water vapor through the tube. The polymer was visibly darkened by the advancing vapor front. With increasing polymer thickness and/or water vapor concentration the wave of darkening similarly intensifies simulating the dark fringe in the Martian circumpolar areas. Surfaces are lightened constantly being renewed by particulate material settling from the atmosphere. It is hypothesized that light and dark areas have polymer coatings, but light areas have small particles which scatter white light more effectively and appear brighter on the surface of Mars.

Oyama, V. I.↗

New two-dimensional photon camera

A photon-sensitive camera, applicable to speckle imaging of astronomical sources, high-resolution spectroscopy of faint galaxies in a crossed-dispersion spectrograph, or narrow-band direct imaging of galaxies, is presented. The camera is shown to supply 8-bit by 8-bit photon positions (256 x 256 pixels) for as many as 10 to the 6th photons/sec with a maximum linear resolution of approximately 10 microns. The sequence of photon positions is recorded digitally with a VHS-format video tape recorder or formed into an immediate image via a microcomputer. The four basic elements of the camera are described in detail: a high-gain image intensifier with fast-decay output phosphor, a glass-prism optical-beam splitter, a set of Gray-coded masks, and a photomultiplier tube for each mask. The characteristics of the camera are compared to those of other photon cameras.

Papaliolios, C.↗

Ultraviolet corona detection sensor study

The feasibility of detecting electrical corona discharge phenomena in a space simulation chamber via emission of ultraviolet light was evaluated. A corona simulator, with a hemispherically capped point to plane electrode geometry, was used to generate corona glows over a wide range of pressure, voltage, current, electrode gap length and electrode point radius. Several ultraviolet detectors, including a copper cathode gas discharge tube and a UV enhanced silicon photodiode detector, were evaluated in the course of the spectral intensity measurements. The performance of both silicon target vidicons and silicon intensified target vidicons was evaluated analytically using the data generated by the spectroradiometer scans and the performance data supplied by the manufacturers.

Schmitt, R. J.↗

Calculation of resolution for a windowless charge coupled device (CCD)-Digicon

A new version of an intensified charge-coupled device (ICCD) system, which is based on the incorporation of a CsI mesh photocathode and a thinned backside-illuminated CCD into a Space Telescope design Digicon tube, is being developed for future use in space-based observations in the Extreme Ultraviolet waveband. In this paper, a report is presented of the results of computer simulations involving the effects of the non-uniform electrostatic field near the mesh photocathode on imaging properties (especially, the spread function and modulation transfer function) of the detector system. The results are of importance in the design of the front end of the tube and the selection of optimum tube operating conditions. The overall resolution characteristics of the tube, including the effects of the mesh, the electron optics of the region between the mesh photocathode and the CCD target, and the structure of the CCD itself, are estimated.

Jia, X. Z.↗

Flame Structure Comparison using Jet-A and an isoparaffinic fuel in a lean direct injection flame tube combustor

This paper offers a first look at some recently acquired optical data. The effect of reference velocity on flame thickness, fuel atomization, and relative speciation of OH, CH, C2, and soot for two National Jet Fuel Combustion Program (NJFCP) fuels are explored in this paper. The NJFCP fuels are an average Jet-A, designated A-2 with a derived cetane number (DCN) of 49, and an isoparaffinic kerosene, C-4. C-4 fuel is made up primarily of C9 - C13, and C16 isoparaffins and is a combination of 60% Sasol IPK and 40% GEVO alcohol-to-jet (ATJ). C-4 has a DCN of 28. Both fuels begin distillation at about the same temperature, but C-4 completes about 30 degrees Celsius lower than A-2. Chemiluminescence images were acquired in a 5-atm gas turbine flame tube combustor using the NASA 7-point lean direct injector (LDI). The flame characteristics were determined through imaging with three scientific cameras. OH*, CH*, and C2* chemiluminescence were collected through narrow bandpass filters centered at 313nm, 430nm and 515nm onto an intensified high-speed camera framed at 8-kHz. A second high-speed camera collected color flame images at rates between 40 and 50 kHz. An ICCD camera framed at 20 Hz was used to record planar laser scatter from liquid fuel. Differences in speciation for the chemiluminescent species was observed between the two fuels. Some reasons for the differences are explored in this paper.

gas turbine combustion↗

Analysis of SOFCAL calibration data

Ionization calorimeters determine the total energy of a particle by absorbing, within the mass of the calorimeter, the entire energy of the particle or a significant (and determinable) fraction of it. The JACEE group has used passive ionization calorimetery, which employs photographic emulsions as the detector medium, to measure the charge composition and energy spectrum of cosmic rays up to, and exceeding, 10(exp 14)eV. The SOFIC approach depends similarly on the use of three-dimensional nuclear-electromagnetic shower theory to relate the ionization deposits obtained during a shower to the energy of the particle causing the shower. Bundles of thousands of scintillating optical fibers are read out using image-intensified CCD's. Such an event may be triggered by a fast shower detector placed under the instrument or if only heavy particles are of interest, from a fast primary Cerention detector placed above the calorimeter. In the first study, fast Hammatsu photomultiplier tubes were purchased and tested for possible application for a triggering purpose. In the second study, some refinements have been made to the theoretical treatment of hadronic interactions in the central collision region. These will be helpful in improving the simulations necessary for observations of high energy cosmic ray nuclei with a SOFIC.

Gregory, John C.↗

A Normal Incidence X-ray Telescope (NIXT) sounding rocket payload

Work on the High Resolution X-ray (HRX) Detector Program is described. In the laboratory and flight programs, multiple copies of a general purpose set of electronics which control the camera, signal processing and data acquisition, were constructed. A typical system consists of a phosphor convertor, image intensifier, a fiber optics coupler, a charge coupled device (CCD) readout, and a set of camera, signal processing and memory electronics. An initial rocket detector prototype camera was tested in flight and performed perfectly. An advanced prototype detector system was incorporated on another rocket flight, in which a high resolution heterojunction vidicon tube was used as the readout device for the H(alpha) telescope. The camera electronics for this tube were built in-house and included in the flight electronics. Performance of this detector system was 100 percent satisfactory. The laboratory X-ray system for operation on the ground is also described.

Golub, Leon↗

High intensity portable fluorescent light

Eight high intensity portable fluorescent lights were produced. Three prototype lights were also produced, two of which were subsequently updated to the physical and operational configuration of the qualification and flight units. Positioning of lamp apertures and reflectors in these lights is such that the light is concentrated and intensified in a specific pattern rather than widely diffused. Indium amalgam control of mercury vapor pressure in the lamp gives high output at lamp ambient temperatures up to 105 C. A small amount of amalgam applied to each electrode stem helps to obtain fast warm-up. Shrinking a Teflon sleeve on the tube and potting metal caps on each end of the lamp minimizes dispersion of mercury vapor and glass particles in the event of accidental lamp breakage. Operation at 20 kHz allows the lamps to consume more power than at low frequency, thus increasing their light output and raising their efficiency. When used to expose color photographic film, light from the lamps produces results approximately equal to sunlight.

Kendall, F. B.↗

A computer-aided telescope pointing system utilizing a video star tracker

The Video Inertial Pointing (VIP) System is being developed to satisfy the acquisition and pointing requirements of astronomical telescopes. VIP employs a single video sensor to generate three-axis pointing error signals and to provide inputs for a cathode ray tube (CRT) display of the star field. The pointing error signals update the telescope's gyro stabilization system. The CRT display facilitates target acquisition and positioning of the telescope by a remote operator. The present paper describes the analysis, simulation, and hardware development of a prototype, advanced VIP system. An early model of the system utilizing a silicon-intensified target vidicon camera has flown on a balloon-borne telescope and is briefly described. The advanced system, which can employ either a vidicon camera or a charge-coupled device video sensor, has been tested using an analog/digital hybrid simulation. The advanced VIP hardware is described, and the simulation results presented.

Lorell, K. R.↗

Photon-counting detector arrays based on microchannel array plates

The recent development of the channel electron multiplier (CEM) and its miniaturization into the microchannel array plate (MCP) offers the possibility of fully combining the advantages of the photographic and photoelectric detection systems. The MCP has an image-intensifying capability and the potential of being developed to yield signal outputs superior to those of conventional photomultipliers. In particular, the MCP has a photon-counting capability with a negligible dark-count rate. Furthermore, the MCP can operate stably and efficiently at extreme-ultraviolet and soft X-ray wavelengths in a windowless configuration or can be integrated with a photo-cathode in a sealed tube for use at ultraviolet and visible wavelengths. The operation of one- and two-dimensional photon-counting detector arrays based on the MCP at extreme-ultraviolet wavelengths is described, and the design of sealed arrays for use at ultraviolet and visible wavelengths is briefly discussed.

Timothy, J. G.↗