Search NASASearch

SEARCH · Search NASA

Results for “INTERFEROMETER SYSTEM”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Method and Apparatus of Multiplexing and Acquiring Data from Multiple Optical Fibers Using a Single Data Channel of an Optical Frequency-Domain Reflectometry (OFDR) System

A method and system for multiplexing a network of parallel fiber Bragg grating (FBG) sensor-fibers to a single acquisition channel of a closed Michelson interferometer system via a fiber splitter by distinguishing each branch of fiber sensors in the spatial domain. On each branch of the splitter, the fibers have a specific pre-determined length, effectively separating each branch of fiber sensors spatially. In the spatial domain the fiber branches are seen as part of one acquisition channel on the interrogation system. However, the FBG-reference arm beat frequency information for each fiber is retained. Since the beat frequency is generated between the reference arm, the effective fiber length of each successive branch includes the entire length of the preceding branch. The multiple branches are seen as one fiber having three segments where the segments can be resolved. This greatly simplifies optical, electronic and computational complexity, and is especially suited for use in multiplexed or branched OFS networks for SHM of large and/or distributed structures which need a lot of measurement points.

Parker, Jr., Allen R

Self-synchronizing Schlieren photography and interferometry for the visualization of unsteady transonic flows

The use of self synchronizing stroboscopic Schlieren and laser interferometer systems to obtain quantitative space time measurements of distinguished flow surfaces, steakline patterns, and the density field of two dimensional flows that exhibit a periodic content was investigated. A large field single path stroboscopic Schlieren system was designed, constructed and successfully applied to visualize four periodic flows: near wake behind an oscillating airfoil; edge tone sound generation; 2-D planar wall jet; and axisymmetric pulsed sonic jet. This visualization technique provides an effective means of studying quasi-periodic flows in real time. The image on the viewing screen is a spatial signal average of the coherent periodic motion rather than a single realization, the high speed motion of a quasi-periodic flow can be reconstructed by recording photographs of the flow at different fixed time delays in one cycle. The preliminary design and construction of a self synchronizing stroboscopic laser interferometer with a modified Mach-Zehnder optical system is also reported.

Kadlec, R.

Micro-Precision Interferometer: Pointing Control System

This paper describes the development of the wavefront tilt (pointing) control system for the JPL Micro-Precision Interferometer (MPI). This control system employs piezo-electric actuators and a digital imaging sensor with feedback compensation to reject errors in instrument pointing. Stringent performance goals require large feedback, however, several characteristics of the plant tend to restrict the available bandwidth. A robust 7th-order wavefront tilt control system was successfully implemented on the MPI instrument, providing sufficient disturbance rejection performance to satisfy the established interference fringe visibility.

Micro-Precision Pointing

Phase Fluctuations at Goldstone Derived from 1-Year Site Testing Interferometer Data

A two-element site test interferometer has been deployed at the NASA Deep Space Network (DSN) tracking complex in Goldstone, California, since May 2007. The interferometer system consists of two offset-fed 1.2 m parabolic reflectors which monitor atmospheric-induced amplitude and phase fluctuations on an unmodulated beacon signal (20.199 GHz) broadcast from a geostationary satellite (Anik F2). The geometry of the satellite and the ground-based infrastructure imposes a 48.5 elevation angle with a separation distance of 256 m along an east-west baseline. The interferometer has been recording phase fluctuation data, to date, for 1 yr with an overall system availability of 95 percent. In this paper, we provide the cumulative distribution functions (CDFs) for 1 year of recorded data, including phase rms, spatial structure function exponent, and surface meteorological measurements: surface wind speed, relative humidity, temperature, barometric pressure, and rain rate. Correlation between surface measurements, phase rms, and amplitude rms at different time scales are discussed. For 1 year, phase fluctuations at the DSN site in Goldstone, are better than 23 for 90 percent of the time (at 48.5 elevation). This data will be used to determine the suitability of the Goldstone site as a location for the Next Generation Deep Space Network.

Nessel, James A.

Balloon-borne and aircraft infrared measurements of ethane (C2H6) in the upper troposphere and lower stratosphere

Quantitative infrared measurements of ethane (C2H6) in the upper troposphere and lower stratosphere are reported. The results have been obtained from the analysis of absorption features of the nu9 band at 12.2 microns, which have been identified in high-resolution balloon-borne and aircraft solar absorption spectra. The balloon-borne spectral data were recorded at sunset with the 0.02/cm resolution University of Denver interferometer system, from a float altitude of 33.5 km near Alamogordo, New Mexico, on March 23, 1981. The aircraft spectra were recorded at sunset in July 1978 with a 0.06/cm resolution interferometer aboard a jet aircraft at 12 km altitude, near 35 deg N, 96 deg W. The balloon analysis indicates the C2H6 mixing ratio decreased from 3.5 ppbv near 8.8 km to 0.91 ppbv near 12.1 km. The results are consistent with the column value obtained from the aircraft data.

Goldman, A.

Mass Gauging Demonstrator for Any Gravitational Conditions

The present invention is a mass gauging interferometry system used to determine the volume contained within a tank. By using an optical interferometric technique to determine gas density and/or pressure a much smaller compression volume or higher fidelity measurement is possible. The mass gauging interferometer system is comprised of an optical source, a component that splits the optical source into a plurality of beams, a component that recombines the split beams, an optical cell operatively coupled to a tank, a detector for detecting fringes, and a means for compression. A portion of the beam travels through the optical cell operatively coupled to the tank, while the other beam(s) is a reference.

Korman, Valentin

Piezocomposite Actuator Arrays for Correcting and Controlling Wavefront Error in Reflectors

Three reflectors have been developed and tested to assess the performance of a distributed network of piezocomposite actuators for correcting thermal deformations and total wave-front error. The primary testbed article is an active composite reflector, composed of a spherically curved panel with a graphite face sheet and aluminum honeycomb core composite, and then augmented with a network of 90 distributed piezoelectric composite actuators. The piezoelectric actuator system may be used for correcting as-built residual shape errors, and for controlling low-order, thermally-induced quasi-static distortions of the panel. In this study, thermally-induced surface deformations of 1 to 5 microns were deliberately introduced onto the reflector, then measured using a speckle holography interferometer system. The reflector surface figure was subsequently corrected to a tolerance of 50 nm using the actuators embedded in the reflector's back face sheet. Two additional test articles were constructed: a borosilicate at window at 150 mm diameter with 18 actuators bonded to the back surface; and a direct metal laser sintered reflector with spherical curvature, 230 mm diameter, and 12 actuators bonded to the back surface. In the case of the glass reflector, absolute measurements were performed with an interferometer and the absolute surface was corrected. These test articles were evaluated to determine their absolute surface control capabilities, as well as to assess a multiphysics modeling effort developed under this program for the prediction of active reflector response. This paper will describe the design, construction, and testing of active reflector systems under thermal loads, and subsequent correction of surface shape via distributed peizeoelctric actuation.

piezoelectric actuation

Investigation of Fiber Optics Based Phased Locked Diode Lasers

Optical power beaming requires a high intensity source and a system to address beam phase and location. A synthetic aperture array of phased locked sources can provide the necessary power levels as well as a means to correct for phase errors. A fiber optic phase modulator with a master oscillator and power amplifier (MOPA) using an injection-locking semiconductor optical amplifier has proven to be effective in correcting phase errors as large as 4pi in an interferometer system. Phase corrections with the piezoelectric fiber stretcher were made from 0 - 10 kHz, with most application oriented corrections requiring only 1 kHz. The amplifier did not lose locked power output while the phase was changed, however its performance was below expectation. Results of this investigation indicate fiber stretchers and amplifiers can be incorporated into a MOPA system to achieve successful earth based power beaming.

Burke, Paul D.

Shock compression of FeOOH and implications for iron-water interactions in super-earth magma oceans

Iron(Fe)-water reactions in a magma ocean can influence water storage and density of planets. These reactions can form Fe-O-H phases, whose density, melting, and electronic properties at planetary interior conditions are important for informing planetary models. Here, we study natural goethite (α-FeOOH) that is shock-compressed along its principal Hugoniot. Analysis of our velocity interferometer system for any reflector (VISAR) results extends the equation of state to over 800 GPa. X-ray diffraction and VISAR reflectivity results indicate the onset of melting occurs at ~95 GPa with complete melting by 166 GPa, which may be relevant to low seismic velocity anomalies observed above the core-mantle boundary. Analysis of X-ray emission spectroscopy results up to 285 GPa shows the spin crossover of Fe, with dominantly low spin Fe above ~265 GPa in the melt, supporting formation of dense basal magma oceans in terrestrial planets. Using our measured FeOOH densities, we model planetary interiors up to 10 Earth masses. Assuming FeOOH forms via iron-water reactions, the radius decreases by up to 28%, while the density increases by up to 165% compared to the unreacted cases, providing an avenue to investigate water storage and evolution in super-Earths and sub-Neptunes.

Zhang, Yanyao [Stanford Univ., CA (United States)]

Simultaneous measurement of surface velocity and plasma density with interferometric velocimetry

The apparent velocity measured by an interferometric surface velocimeter is a function of both the surface velocity and the time derivative of the refractive index along the measurement path. We employed this dual sensitivity to simultaneously measure km/s surface velocities and 10 18 cm -3 average plasma densities with combined VISAR (velocity interferometer system for any reflector) and PDV (photonic Doppler velocimetry) measurements in experiments performed on the Z Pulsed Power Facility. We detail the governing equations, associated assumptions, and analysis specifics and show that the surface velocity can be extracted without knowledge of the specific plasma density profile.

47 OTHER INSTRUMENTATION

Shock compression of crystalline TeO 2 to the high-pressure fluid regime: Insights from ab initio molecular dynamics simulations

The shock response of fully-dense and porous crystalline tellurium dioxide (TeO 2 ⁠) to the high-pressure and high-temperature fluid regime was investigated within the framework of density functional theory with Mermin’s generalization to finite temperatures. The principal and porous shock Hugoniot curves were predicted from canonical ab initio molecular dynamics (AIMD) simulations, with the phase space sampled along isotherms up to 80 000 K, for densities ranging from ρ = 3 to 17 g/cm 3 . The polymorphs investigated are α-TeO 2 paratellurite (⁠P4 1 2 1 2), TeO 2 cotunnite (⁠Pnma⁠), and TeO 2 post-cotunnite (⁠P2 1 /m⁠). Based on the discontinuity found in the calculated U s – u p slope of TeO 2 post-cotunnite at a shock velocity of U s ≃ 8.35km/s and a particle velocity of u p ≃ 3.64 km/s, the shock melting temperature and pressure are predicted to be ≃ 6500 K and ≃ 170 GPa. Results from the AIMD simulations are in line with the static compression data of TeO 2 paratellurite and cotunnite, and with the recent shock Hugoniot data for single-crystal α- TeO 2 for pressures up to 85 GPa, obtained using the inclined-mirror method and the velocity interferometer system for any reflector combined with powder gun and two-stage light-gas gun.

74 ATOMIC AND MOLECULAR PHYSICS

Calibration and characterization of the line-VISAR diagnostic at the HED-HIBEF instrument at the European XFEL

In dynamic-compression experiments, the line-imaging Velocity Interferometer System for Any Reflector (VISAR) is a well-established diagnostic used to probe the velocity history, including wave profiles derived from dynamically compressed interfaces and wavefronts, depending on material optical properties. Knowledge of the velocity history allows for the determination of the pressure achieved during compression. Such a VISAR analysis is often based on Fourier transform techniques and assumes that the recorded interferograms are free from image distortions. In this paper, we describe the VISAR diagnostic installed at the HED-HIBEF instrument located at the European XFEL along with its calibration and characterization. It comprises a two-color (532, 1064 nm), three-arm (with three velocity sensitivities) line imaging system. We provide a procedure to correct VISAR images for geometric distortions and evaluate the performance of the system using Fourier analysis. We finally discuss the spatial and temporal calibrations of the diagnostic. As an example, we compare the pressure extracted from the VISAR analysis of shock-compressed polyimide and silicon.

47 OTHER INSTRUMENTATION

Shock propagation in aerogel and TPP foams for inertial fusion energy target design

Achieving practical inertial fusion energy (IFE) requires the development of target designs with well-characterized microstructure and compression response. We measured shock dynamics in low-density (17.5–500 mg/cm 3 ) aerogel and two-photon polymerization (TPP) foams using x-ray phase contrast imaging (XPCI) methods and the Velocity Interferometer System for Any Reflector. By analyzing shock front evolution, we examined how target type and density influence shock propagation and energy dissipation. Talbot-XPCI shows that aerogels support a smooth, bowed shock front due to their homogeneous nanometer-scale pore network. In contrast, TPP foams exhibit irregular, stepwise propagation driven by interactions with their periodic micrometer-scale lattice. Shock velocity follows a power-law relation: aerogels deviate from classical ρ −1/2 scaling due to pore-collapse dissipation, while TPP foams follow the trend with larger uncertainties from density variations. Comparisons with xRAGE simulations reveal systematic underestimation of shock speeds. These results provide the first experimental constraints on shock propagation in TPP foams over a wide density range and highlight the influence of internal structure on anisotropic shock behavior. Our findings support improved benchmarking of EOS and hydrodynamic models and inform the design of foam architectures that promote implosion symmetry in IFE capsules.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY

Optimization of VISAR Mirrors for NIF Targets

The velocity interferometer system for any reflector (VISAR) is a key diagnostic at the National Ignition Facility that is used for measuring propagation and velocities of shocks through a sample for several high energy density campaigns. To support simultaneous measurements with VISAR and other diagnostics, optical mirrors are used to divert the VISAR signal off axis from the primary diagnostic line of sight, which can then be used for other measurements. Here, in this study, we describe our work on investigating issues with these mirrors to support complex new target geometries and signal variance due to system aging and more demanding polling rates. This paper also describes the key mitigation efforts performed to improve both the flatness and reflectivity of these commonly used mirrors.

National Ignition Facility