Search NASA⌕ Search

SEARCH · Search NASA

Results for “IODINE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Doping behavior of iodine in Hg/0.8/Cd/0.2/Te

The defect state prevailing in iodine doped single-crystal samples of Hg0.8Cd0.2Te, annealed at 450-600 C in Hg vapor, has been deduced from Hall effect measurements on samples cooled to 77 K from the annealing temperature. Results are found to be similar to those previously obtained for iodine doped CdS, i.e. iodine acts as a single donor occupying Te lattice sites with a fraction paired with the native acceptor defects. The concentration of iodine on tellurium lattice sites increases with the partial pressure of Hg, whereas that of the pair species increases as the partial pressure of Hg decreases.

Vydyanath, H. R.↗

Quantitative measurement of density and velocity in compressible flows using laser-induced iodine fluorescence

A nonintrusive optical technique for the quantitative measurement of molecular density and velocity at a point or in an entire cross-sectional plane of a compressible flowfield is reported. Iodine molecules, seeded into the flowfield reservoir, are excited by a tunable narrow-bandwidth laser and the resulting spatially-resolved fluorescence is collected by a single- or multiple-element detector. A theoretical model for the iodine laser-induced fluorescence process is essential for quantitative measurements and is developed using a rate-equation approach. Density measurements using laser-induced fluorescence are normally complicated by collisional quenching; however, the theory predicts that the off-resonant fluorescent signal is directly proportional to density. Velocity is directly related to the Doppler shift of the iodine absorption line, determined by monitoring the broadband fluorescent signal as the laser is tuned in frequency. Experiments in a steady supersonic flowfield are compared with numerical calculations to demonstrate the accuracy of the approach for density and velocity measurement and the lack of perturbation to the flowfield by the iodine seeding. Extensions of the current approach to density and velocity measurement in lower Mach number flows, to the measurement of pressure and temperature, and to temporally-resolved measurements are discussed.

Mcdaniel, J. C.↗

Direct solar-pumped iodine laser amplifier

During this period the parametric studies of the iodine laser oscillator pumped by a Vortek simulator were carried out before amplifier studies. The amplifier studies are postponed to the extended period after completing the parametric studies. In addition, the kinetic modeling of a solar-pumped iodine laser amplifier, and the experimental work for a solar pumped dye laser amplifier are in progress. This report contains three parts: (1) a 10 W CW iodine laser pumped by a Vortek solar simulator; (2) kinetic modeling to predict the time to lasing threshold, lasing time, and energy output of solar-pumped iodine laser; and (3) the study of the dye laser amplifier pumped by a Tamarack solar simulator.

Han, K. S.↗

Medical effects of iodine disinfection products in spacecraft water

Various iodination products (IDPs), including iodinated and iodine-induced new compounds, will be present in the iodine-disinfected water that is expected to be used by crews on the NASA Space Station and on long duration missions. The metabolic intermediaries created by such a process may be more important to crew health than the parent IDPs, and reclamation and recycling may be expected to produce additional products. These medical effects may be expressed in crews as hypersensitivity, allergic, acute toxic, and chronic toxic reactions, as well as modifications of immune system response.

Sauer, Richard L.↗

Direct solar-pumped iodine laser amplifier

A XeCl laser which was developed earlier for an iodine laser oscillator was modified in order to increase the output pulse energy of XeCl laser so that the iodine laser output energy could be increased. The electrical circuit of the XeCl laser was changed from a simple capacitor discharge circuit of the XeCl laser to a Marx system. Because of this improvement the output energy from the XeCl laser was increased from 60 mj to 80 mj. Subsequently, iodine laser output energy was increased from 100 mj to 3 mj. On the other hand, the energy storage capability and amplification characteristics of the Vortek solar simulator-pumped amplifier was calculated expecting the calculated amplification factor is about 2 and the energy extraction efficiency is 26 percent due to the very low input energy density to the amplifier. As a result of an improved kinetic modeling for the iodine solar simulator pumped power amplifier, it is found that the I-2 along the axis of the tube affects seriously the gain profile. For the gas i-C3F7I at the higher pressures, the gain will decrease due to the I-2 as the pumping intensity increases, and at these higher pressures an increase in flow velocity will increase the gain.

Han, Kwang S.↗

Direct solar-pumped iodine laser amplifier

The optimum conditions of a solar pumped iodine laser are found in this research for the case of a continuous wave operation and a pulsed operation. The optimum product of the pressure(p) inside the laser tube and the tube diameter(d) was pd=40 approx. 50 torr-cm on the contrary to the case of a high intensity flashlamp pumped iodine laser where the optimum value of the product is known to be pd=150 torr-cm. The pressure-diameter product is less than 1/3 of that of the high power iodine laser. During the research period, various laser materials were also studied for solar pumping. Among the laser materials, Nd:YAG is found to have the lowest laser threshold pumping intensity of about 200 solar constant. The Rhodamine 6G was also tested as the solar pumped laser material. The threshold pumping power was measured to be about 20,000 solar constant. The amplification experiment for a continuously pumped iodine laser amplifier was performed using Vortek solar simulator and the amplification factors were measured for single pass amplification and triple pass amplification of the 15 cm long amplifier tube. The amplification of 5 was obtained for the triple pass amplification.

Han, Kwang S.↗

Influence of iodine on the treatment of spacecraft humidity condensate to produce potable water

Several compounds in the ersatz humidity condensate do react with iodine to form iodine-substituted organic compounds (TOI), most notably phenol, acetaldehyde, ethanol, and sodium formate. Iodination of the ersatz humidity condensate produced 3.0 to 3.5 mg/L of TOI within 24 hours. The TOI that was produced by the passage of the ersatz humidity condensate through the first iodinated resin (IR) in the adsorption system was removed by the granular activated carbon that followed. TOI detected in the final effluent was formed by the reaction of the non-adsorbable condensate compounds with the final IR in the treatment series. The activated carbon bed series in the adsorption system performed poorly in its removal of TOC. The rapid breakthrough of TOC was not surprising, as the ersatz humidity condensate contained several highly soluble organic compounds, alcohols and organic acids.

Symons, James M.↗

Investigation of the excited state iodine lifetime in the photodissociation of perfluoroalkyl iodides

An evaluation of prospective laser materials for a space-based solar pumped laser system over the past decade has resulted in the identification of the iodine photodissociation laser as that system best suited to solar-pumped high energy operation. The active medium for the solar-pumped iodine photodissociation laser is from the family of perfluoroalkyl iodides. These lasants have the general form C(n)F(2n + 1)I, often abbreviated as RI. These iodides are known to exhibit photodissociaiton of the C-I bond when irradiated by near UV photons. The focus was on the experimental determination of the lifetime of the excited iodine atom following photodissociation of C4F9I, and also to monitor fluorescence from the iodine molecule at 500 nm to determine if I2 is being produced in the process. Photodissociation is achieved using an XeCl excimer laser with an output wavelength of 308 nm. The XeCl beam is focused into the middle of a cylindrical quartz cell containing the lasant. The laser pulse is detected with a fast risetime photomultiplier tube as it exits the cell. Other aspects of the investigation are discussed.

Cobb, Stephen H.↗

Long-term corrosion evaluation of stainless steels in Space Shuttle iodinated resin and water

The effects of stainless steel exposure to iodinated water is a concern in developing the Integrated Water System (IWS) for Space Station Freedom. The IWS has a life requirement of 30 years, but the effects of general and localized corrosion over such a long period have not been determined for the candidate materials. In 1978, Umpqua Research Center immersed stainless steel 316L, 321, and 347 specimens in a solution of deionized water and the Space Shuttle microbial check valve resin. In April 1990, the solution was chemically analyzed to determine the level of corrosion formed, and the surface of each specimen was examined with scanning electron microscopy and metallography to determine the extent of general and pitting corrosion. This examination showed that the attack on the stainless steels was negligible and never penetrated past the first grain boundary layer. Of the three alloys, 316L performed the best; however, all three materials proved to be compatible with an aqueous iodine environment. In addition to the specimens exposed to aqueous iodine, a stainless steel specimen (unspecified alloy) was exposed to moist microbial check valve resin and air for a comparable period. This environment allowed contact of the metal to the resin as well as to the iodine vapor. Since the particular stainless steel alloy was not known, energy dispersive spectroscopy was used to determine that this alloy was stainless steel 301. The intergranular corrosion found on the specimen was limited to the first grain boundary layer.

Krohn, Douglas D.↗

A model for a continuous-wave iodine laser

A model for a continuous-wave (CW) iodine laser has been developed and compared with the experimental results obtained from a solar-simulator-pumped CW iodine laser. The agreement between the calculated laser power output and the experimental results is generally good for various laser parameters even when the model includes only prominent rate coefficients. The flow velocity dependence of the output power shows that the CW iodine laser cannot be achieved with a flow velocity below 1 m/s for the present solar-simulator-pumped CW iodine laser system.

Hwang, In H.↗

Graphite intercalation compound with iodine as the major intercalate

Halogenated graphite CBr(x)I(y) (I less than y/x less than 10) was made by exposing graphite materials to either pure Br2 or an I2/Br2/HBr mixture to initiate the reaction, and then to iodine vapor containing a small amount of Br2/HBr/IBr to complete the intercalation reaction. Wetting of the graphite materials by the I2/Br2/HBr mixture is needed to start the reaction, and a small amount of Br2/HBr/IBr is needed to complete the charge transfer between iodine and carbon. The interplanar spacings for the graphite materials need to be in the 3.35 to 3.41 A range. The X-ray diffraction data obtained from the halogenated HOPG indicate that the distance between the two carbon layers containing intercalate is 7.25 A. Electrical resistivity of the fiber product is from 3 to 6.5 times the pristine value, The presence of a small amount of isoprene rubber in the reaction significantly increased the iodine-to-bromine ratio in the product. In this reaction, rubber is known to generate HBr and to slowly remove bromine from the vapor. The halogenation generally caused a 22 percent to 25 percent weight increase. The halogens were found uniformly distributed in the product interior. However, although the surface contains very little iodine, it has high concentrations of bromine and oxygen. It is believed that the high concentrations of bromine and oxygen in this surface cause the halogenated fiber to be more resistant to structural damage during subsequent fluorination to fabricate graphite fluoride fibers.

Hung, Ching-Cheh↗

Numerical simulation of iodine speciation in relation to water disinfection aboard manned spacecraft I. Equilibria

Elemental iodine (I2) is currently used as the drinking water disinfectant aboard the Shuttle Orbiter and will also be incorporated into the water recovery and distribution system for the International Space Station Alpha. Controlled release of I2 is achieved using the Microbial Check Valve (MCV), a flow-through device containing an iodinated polymer which imparts a bacteriostatic residual concentration of approximately 2mg/L to the aqueous stream. During regeneration of MCV canisters, I2 concentrations of approximately 300 mg/L are used. Dissolved iodine undergoes a series of hydrolytic disproportionation and related reactions which result in the formation of an array of inorganic species including: I-, I3-, HOI, OI-, IO3-, HIO3, I2OH-, I2O(-2), and H2OI+. Numerical estimation of the steady-state distribution of inorganic iodine containing species in pure water at 25 degrees C has been achieved by simultaneous solution of the multiple equilibrium expressions as a function of pH. The results are reported herein.

NASA Discipline Environmental Health↗

Colorimetric Solid Phase Extraction for the Measurement of Total I (Iodine, Iodide, and Triiodide) in Spacecraft Drinking Water

An experimental drinking water monitoring kit for the measurement of iodine and silver(I) was recently delivered to the International Space Station (ISS). The kit is based on Colorimetric Solid Phase Extraction (CSPE) technology, which measures the change in diffuse reflectance of indicator disks following exposure to a water sample. To satisfy additional spacecraft water monitoring requirements, CSPE has now been extended to encompass the measurement of total I (iodine, iodide, and triiodide) through the introduction of an oxidizing agent, which converts iodide and triiodide to iodine, for measurement using the same indicator disks currently being tested on ISS. These disks detect iodine, but are insensitive to iodide and triiodide. We report here the operational considerations, design, and ground-based performance of the CSPE method for total I. The results demonstrate that CSPE technology is poised to meet NASA's total I monitoring requirements.

Lipert, Robert J.↗

Thermal Analysis of Iodine Satellite (iSAT) from Preliminary Design Review (PDR) to Critical Design Review (CDR)

The Iodine Satellite (iSAT) is a 12U cubesat with a primary mission to demonstrate the iodine fueled Hall Effect Thruster (HET) propulsion system. The spacecraft (SC) will operate throughout a one year mission in an effort to mature the propulsion system for use in future applications. The benefit of the HET is that it uses a propellant, iodine, which is easy to store and provides a high thrust-to-mass ratio. This paper will describe the thermal analysis and design of the SC between Preliminary Design Review (PDR) and Critical Design Review (CDR). The design of the satellite has undergone many changes due to a variety of challenges, both before PDR and during the time period discussed in this paper. Thermal challenges associated with the system include a high power density, small amounts of available radiative surface area, localized temperature requirements of the propulsion components, and unknown orbital parameters. The thermal control system is implemented to maintain component temperatures within their respective operational limits throughout the mission, while also maintaining propulsion components at the high temperatures needed to allow gaseous iodine propellant to flow. The design includes heaters, insulation, radiators, coatings, and thermal straps. Currently, the maximum temperatures for several components are near to their maximum operation limit, and the battery is close to its minimum operation limit. Mitigation strategies and planned work to solve these challenges will be discussed.

Mauro, Stephanie↗

The Iodine Satellite (iSAT) Propellant Feed System - Design and Development

The development, modeling, and testing of components and subsystems required to feed iodine propellant to a 200-W Hall thruster and cathode are described. This work aims to address design deficiencies and issues associated with the propellant feed system that were revealed by an integrated thruster-cathode-feed system test. The feed system design is modified to use materials that are more resistant to the highly-reactive nature of iodine propellant. Dynamic modeling indicates that the inclusion of additional constraints on feed system tubing will reduce the vibrationally-induced stresses that occur during launch. Full spacecraft thermal modeling show that the feed system heater power levels are sufficient to heat the tank and propellant lines to operating temperatures, where iodine in the tank is sublimed to supply propellant for operation and the tubing is elevated in temperature to keep propellant from redepositing to block the flow. Experiments are conducted to demonstrate that is it possible through the application of heating to clear an iodine deposit blocking the flow. Deposits in the low-pressure portion of the system near the exit to vacuum are shown to be relatively easy to remove in this manner while blockages forming upstream nearer to the higher-pressure propellant tank require significantly more effort to remove. Fluid flow modeling of the feed system is performed, exhibiting some qualitative agreement with experimental data. However, the highly viscous nature of the fluid flow and the dependence of the component flow coefficients on the Reynolds number are likely causes of the generally-poor quantitative agreement between the modeling results and experimentally-measured fluid flow properties.

Polzin, Kurt A.↗

Corrosion Behavior of Stainless Steel 304 and Nickel 625 Under Iodine Vapor at 300 °C

The chemical, structural, and microstructural behavior of stainless steel 304 (SS 304) and nickel 625 (Ni 625) were probed after exposure to iodine vapor laminar flow at 300 °C. This work was conducted in support of the development of in-space propulsion utilizing iodine as a propellant. The kinetics of corrosion was measured in a custom-built iodine-compatible thermogravimetric analyzer rig at 300 °C in which samples were exposed to an iodine laminar vapor flow of 1 mg/min (carried by 20 mL/min argon gas) for up to 31 days. Samples were characterized after the experiment by X-ray diffraction, electron microscopy, energy dispersive X-ray spectroscopy, and dynamic secondary ion mass spectrometry. All samples formed scales consisting mainly of metal oxyiodides showing different chemistry, microstructure, and crystalline phases. The paralinear rate law best describes the kinetics of oxidation of the samples. SS 304 exhibited slightly slower kinetics of oxidation (106±3·10(exp –5) mg/sq.cm/day) than Ni 625 (122±3·10(exp –5) mg/sq.cm/day) in the low-oxygen and low-water environment.

Chemistry and Materials↗

Hot Water, Cold Reality: Feasibility Assessment of Iodine Removal in Heated Spacecraft Potable Water Systems

The current eXploration Potable Water Dispenser (xPWD) design removes iodine upstream of the heated leg due to concerns with the Activated Carbon and Ion Exchange (ACTEX) functionality in hot water, leaving the downstream volume without residual biocide. The NESC determined that this non-iodinated volume is a concern for microbial growth during exploration missions and proposed 33 biocide architecture options for future missions that could address this concern. The top-ranked architecture out of the report was Option 1: moving the iodine removal media as close to the dispensing needle as possible to minimize the wetted components without biocide in the xPWD. Three main challenges were identified with this proposed configuration. First, the hot water at 175 ± 25 °F is a concern for the potential physical degradation of the ion exchange resin and lowered adsorption capacity in activated carbon. Second, moving the ACTEX or alternative sorption media closer to the dispense needle increases the unheated volume downstream of the heater, challenging the ability for dispensed water to meet temperature requirements. Finally, bubbles evolved from dissolved gas coming out of solution in the heater could clog or reduce the efficiency of the sorption media. To address the first challenge, more thermally robust ion exchange resins were identified and adsorption capacity tests were planned and will be discussed in a companion ICES paper (ICES-2026-5). To address the dispense temperature concerns, allowable bed size and architectural configuration changes are proposed. The value of adding phase separators to remove bubbles and potential implementation schemes are discussed. These findings support the development of potable water systems resilient to microbial risks during long-duration space missions.

Biocide↗

Hot Water, Cold Reality: Feasibility Assessment of Iodine Removal in Heated Spacecraft Potable Water Systems

The current eXploration Potable Water Dispenser (xPWD) design removes iodine upstream of the heated leg due to concerns with the Activated Carbon and Ion Exchange (ACTEX) functionality in hot water, leaving the downstream volume without residual biocide. The NESC determined that this non-iodinated volume is a concern for microbial growth during exploration missions and proposed 33 biocide architecture options for future missions that could address this concern. The top-ranked architecture out of the report was Option 1: moving the iodine removal media as close to the dispensing needle as possible to minimize the wetted components without biocide in the xPWD. Three main challenges were identified with this proposed configuration. First, the hot water at 175 ± 25 °F is a concern for the potential physical degradation of the ion exchange resin and lowered adsorption capacity in activated carbon. Second, moving the ACTEX or alternative sorption media closer to the dispense needle increases the unheated volume downstream of the heater, challenging the ability for dispensed water to meet temperature requirements. Finally, bubbles evolved from dissolved gas coming out of solution in the heater could clog or reduce the efficiency of the sorption media. To address the first challenge, more thermally robust ion exchange resins were identified and adsorption capacity tests were planned and will be discussed in a companion ICES paper (ICES-2026-5). To address the dispense temperature concerns, allowable bed size and architectural configuration changes are proposed. The value of adding phase separators to remove bubbles and potential implementation schemes are discussed. These findings support the development of potable water systems resilient to microbial risks during long-duration space missions.

PWD↗