Search NASA⌕ Search

SEARCH · Search NASA

Results for “ION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Dual-Polarity Ion Trap Mass Spectrometry: Dynamic Monitoring and Controlling Gas-phase Ion–Ion Reactions

A dual-polarity linear ion trap (LIT) mass spectrometer was developed in this study, and the method for simultaneously controlling and detecting cations and anions was proposed and realized in the LIT. With the application of an additional dipolar DC field on the ejection electrodes of an LIT, dual-polarity mass spectra could be obtained, which include both the mass-to-charge (m/z) ratio and charge polarity information of an ion. Compared with conventional method, the ion ejection and detection efficiency could also be improved by about one-fold. Furthermore, ion–ion reactions within the LIT could be dynamically controlled and monitored by manipulating the distributions of ions with opposite charge polarities. This method was then used to control and study the reaction kinetics of ion–ion reactions, including electron transfer dissociation (ETD) and charge inversion reactions. A dual-polarity collision-induced dissociation (CID) experiment was proposed and performed to enhance the sequence coverage of a peptide ion. Ion trajectory simulations were also carried out for concept validation and system optimization. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Principles of Ion Selection, Alignment, and Focusing in Tandem Ion Mobility Implemented Using Structures for Lossless Ion Manipulations (SLIM)

Tandem ion mobility (IM) enables the characterization of subpopulations of ions from larger ensembles, including differences that cannot be resolved in a single dimension of IM. Tandem IM consists of at least two IM regions that are each separated by an ion selection region. In many implementations of tandem IM, ions eluting from a dimension of separation are filtered and immediately transferred to the subsequent dimension of separation (selection-only experiments). We recently reported a mode of operation in which ions eluting from a dimension are trapped prior to the subsequent dimension (selection-trapping experiments), which was implemented on an instrument constructed using the structures for lossless ion manipulations (SLIM) architecture. Here, we use a combination of experiments and trajectory simulations to characterize aspects of the selection, trapping, and separation processes underlying these modes of operation. For example, the actual temporal profile of filtered ions can be very similar to the width of the waveforms used for selection, but depending on experimental parameters, can differ by up to ± 500 μs. Experiments and simulations indicate that ions in selection-trapping experiments can be spatially focused between dimensions, which removes the broadening that occurred during the preceding dimension. During focusing, individual ions are thermalized, which aligns and establishes common initial conditions for the subsequent dimension. Therefore, selection-trapping experiments appear to offer significant advantages relative to selection-only experiments, which we anticipate will become more pronounced in future experiments that make use of longer IM separations, additional dimensions of analysis, and the outcomes of this study. .

74 ATOMIC AND MOLECULAR PHYSICS↗

The charge reduction rate for multiply charged polymer ions via ion–ion recombination at atmospheric pressure

The charge reduction of multiply charged macromolecular ions via recombination with small ions in the gas phase is commonly employed to modulate the charge on macromolecules prior to mass spectrometric and mobility analyses. We employ a recently developed continuum-Molecular Dynamics (MD) calculation approach to determine the recombination rate coefficient of multiply charged (1 to 7 excess positive charged) polyethylene glycol ions (mass of 4600 Da) with smaller singly charged anions, modeled as NO 2 – ions. The continuum-MD approach accounts explicitly for the influence of the background gas on the recombination process, accounts explicitly for ion translational, vibrational, and rotational motion, and enables recombination rate coefficient calculation in nitrogen near atmospheric pressure, wherein neither low pressure nor high pressure recombination theories are strictly applicable. Continuum-MD simulations yield recombination rate coefficients near 3.9 × 10 –14 m 3 s –1 for singly charged ions, increasing to 3.0 × 10 –11 m 3 s –1 for the +7 ion. Pre-existing collision rate coefficient expressions for rigid ions are found to be within a factor of 2–5 of calculations for all charge states, but their use requires knowledge of an appropriate collision distance, which is not well-defined for flexible polymer ions. Continuum-MD-inferred rate coefficients are incorporated into a model of charge reduction, and the charge state distribution versus anion concentration determined with it is compared to charge reduction measurements made via atmospheric pressure differential mobility analysis. Furthermore, good agreement is observed between simulations and experiments; although results are extremely sensitive to the recombination rate coefficients, experimental results are bound by models utilizing rates within a factor of 2 (0.5–2.0×) of the continuum-MD rates.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Electron-less negative ion extraction from ion-ion plasmas

This paper presents experimental results showing that continuous negative ion extraction, without co-extracted electrons, is possible from highly electronegative SF{sub 6} ion-ion plasma at low gas pressure (1 mTorr). The ratio between the negative ion and electron densities is more than 3000 in the vicinity of the two-grid extraction and acceleration system. The measurements are conducted by both magnetized and non-magnetized energy analyzers attached to the external grid. With these two analyzers, we show that the extracted negative ion flux is almost electron-free and has the same magnitude as the positive ion flux extracted and accelerated when the grids are biased oppositely. The results presented here can be used for validation of numerical and analytical models of ion extraction from ion-ion plasma.

74 ATOMIC AND MOLECULAR PHYSICS↗

Nuclear quantum effects in water exchange around lithium and fluoride ions

We employ classical and ring polymer molecular dynamics simulations to study the effect of nuclear quantum fluctuations on the structure and the water exchange dynamics of aqueous solutions of lithium and fluoride ions. While we obtain reasonably good agreement with experimental data for solutions of lithium by augmenting the Coulombic interactions between the ion and the water molecules with a standard Lennard-Jones ion-oxygen potential, the same is not true for solutions of fluoride, for which we find that a potential with a softer repulsive wall gives much better agreement. A small degree of destabilization of the first hydration shell is found in quantum simulations of both ions when compared with classical simulations, with the shell becoming less sharply defined and the mean residence time of the water molecules in the shell decreasing. In line with these modest differences, we find that the mechanisms of the exchange processes are unaffected by quantization, so a classical description of these reactions gives qualitatively correct and quantitatively reasonable results. We also find that the quantum effects in solutions of lithium are larger than in solutions of fluoride. This is partly due to the stronger interaction of lithium with water molecules, partly due to the lighter mass of lithium and partly due to competing quantum effects in the hydration of fluoride, which are absent in the hydration of lithium.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Rechargeable Aluminum-Ion Batteries Based on an Open-Tunnel Framework

Rechargeable batteries based on an abundant metal such as aluminum with a three-electron transfer per atom are promising for large-scale electrochemical energy storage. Aluminum can be handled in air, thus offering superior safety, easy fabrication, and low cost. But, the development of Al-ion batteries has been challenging due to the difficulties in identifying suitable cathode materials. This study presents the use of a highly open framework Mo 2.5 + y VO 9 + z as a cathode for Al-ion batteries. The open-tunnel oxide allows a facile diffusion of the guest species and provides sufficient redox centers to help redistribute the charge within the local host lattice during the multivalent-ion insertion, thus leading to good rate capability with a specific capacity among the highest reported in the literature for Al-based batteries. Our study also presents the use of Mo 2.5 + y VO 9 + z as a model host to develop a novel ultrafast technique for chemical insertion of Al ions into host structures. The microwave-assisted method employing diethylene glycol and aluminum diacetate (Al(OH)(C 2 H 3 O 2 ) 2 ) can be performed in air in as little as 30 min, which is far superior to the traditional chemical insertion techniques involving moisture-sensitive organometallic reagents. The Al-inserted Al x Mo 2.5 + y VO 9 + z obtained by the microwave-assisted chemical insertion can be used in Al-based rechargeable batteries.

25 ENERGY STORAGE↗

Completely Multipolar Model for Many-Body Water–Ion and Ion–Ion Interactions

This work constructs an advanced force field, the Completely Multipolar Model (CMM), to quantitatively reproduce each term of an energy decomposition analysis (EDA) for aqueous solvated alkali metal cations and halide anions and their ion pairings. We find that all individual EDA terms remain well-approximated in the CMM for ion-water and ion-ion interactions, except for polarization, which shows errors due to the partial covalency of ion interactions near their equilibrium. We quantify the onset of the dative bonding regime by examining the change in molecular polarizability and Mayer bond indices as a function of distance, showing that partial covalency manifests by breaking the symmetry of atomic polarizabilities while strongly damping them at short-range. This motivates an environment-dependent atomic polarizability parameter that depends on the strength of the local electric field experienced by the ions to account for strong damping, with anisotropy introduced by atomic multipoles. The resulting CMM model for ions provides accurate dimer surfaces and three-body polarization and charge transfer compared to EDA, and shows excellent performance on various ion benchmarks including vibrational frequencies and cluster geometries.

Heindel, Joseph P↗

Increase in the Fluorine-Ion Conductivity of Single Crystals of Tysonite-type CeF{sub 3} Superionic Conductor by Substituting Polarized Cd{sup 2+} Ions for Ce{sup 3+} Ions

The fluorine-ion conductivity of single crystals with a tysonite (LaF{sub 3}) structure with heterovalent isomorphic substitutions of highly polarizable Cd{sup 2+} cations with a 18-electron shell for rare earth ions Ce{sup 3+} have been studied for the first time. Ce{sub 0.995}Cd{sub 0.005}F{sub 2.995} single crystals have been grown from melt by the Bridgman technique in a fluorinating atmosphere. The fluorine-ion conductivity of single crystal is measured by impedance spectroscopy in the temperature range from 153 to 1073 K, where it increases by a factor of 10{sup 9}, approaching the value σ{sub dc} = 5 × 10{sup –2} S/cm at 1073 K. At T{sub 0} = 450 ± 20 K, the dependence σ{sub dc}(T) is split into two portions with the ion-transport activation enthalpy ΔH{sub σ} = 0.39 ± 0.01 eV (T < T{sub 0}) and ΔH{sub σ} = 0.23 ± 0.02 eV (T > T0). It is found that at T = 293 K the conductivity σ{sub dc} = 3 × 10{sup –5} S/cm of Ce{sub 0.995}Cd{sub 0.005}F{sub 2.995} crystal is higher by a factor of 10 than the conductivity of the tysonite matrix CeF{sub 3} and close to the σ{sub dc} value for Ce{sub 0.995}Sr{sub 0.005}F{sub 2.995} crystal. This finding indicates a significant effect of the substitutions of Cd{sup 2+} ions for Ce{sup 3+} on the σdc value and the advantage of Cd{sup 2+} ions over Ca{sup 2+} and Ba{sup 2+} from the viewpoint of increasing σ{sub dc}.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Improved ion optics for introduction of ions into a 9.4-T Fourier transform ion cyclotron resonance mass spectrometer

Fourier transform ion cyclotron resonance (FT-ICR) mass spectrometry provides unparalleled mass accuracy and resolving power.[1],[2] With electrospray ionization (ESI), ions are typically transferred into the mass spectrometer through a skimmer, which serves as a conductance-limiting orifice. However, the skimmer allows only a small fraction of incoming ions to enter the mass spectrometer. An ion funnel, originally developed by Smith and coworkers at Pacific Northwest National Laboratory (PNNL)[3-5] provides much more efficient ion focusing and transfer. The large entrance aperture of the ion funnel allows almost all ions emanating from a heated capillary to be efficiently captured and transferred, resulting in nearly lossless transmission.

42 ENGINEERING↗

Nonlinear kinetic simulation study of the ion–ion streaming instability in single- and multi-ion species plasmas

The nonlinear evolution of the ion–ion streaming instability (IISI) is studied using numerical techniques novel to this problem that afford direct insight into the evolution of the particle distributions of each species. Here, during the linear phase of the instability, we demonstrate quantitative agreement with linear kinetic theory. Subsequently, the electrostatic field generated by the IISI causes ring-like velocity distributions of ions to form that are both heated and slowed to varying degrees relative to their initial flows. Due to variation in the trapping conditions for ion species of differing charge-to-mass ratio, when flows of multiple species interact, the nonlinear evolution of each species can be starkly different: we show a case where a lighter ion species is completely stopped by a heavier ion species via the IISI alone (i.e., without collisions) and, for the first time, demonstrate how the IISI can introduce a relative flow between ion species that initially have the same flow velocities, thereby separating them.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Comprehensive Gas-Phase Peptide Ion Structure Studies Using Ion Mobility Techniques: Part 2. Gas-Phase Hydrogen/Deuterium Exchange for Ion Population Estimation

Gas-phase hydrogen/deuterium exchange (HDX) using D{sub 2}O reagent and collision cross-section (CCS) measurements are utilized to monitor the ion conformers of the model peptide acetyl-PAAAAKAAAAKAAAAKAAAAK. The measurements are carried out on a home-built ion mobility instrument coupled to a linear ion trap mass spectrometer containing electron transfer dissociation (ETD) capabilities. ETD is utilized to obtain per-residue deuterium uptake data for select ion conformers, and a new algorithm is presented for interpreting the HDX data. Using molecular dynamics (MD) production data and a hydrogen accessibility scoring (HAS)-number of effective collisions (NEC) model, hypothetical HDX behavior is attributed to various in-silico candidate (CCS match) structures. The HAS-NEC model is applied to all candidate structures, and non-negative linear regression is employed to determine structure contributions resulting in the best match to deuterium uptake. The accuracy of the HAS-NEC model is tested with the comparison of predicted and experimental isotopic envelopes for several of the observed c-ions. It is proposed that gas-phase HDX can be utilized effectively as a second criterion (after CCS matching) for filtering suitable MD candidate structures. In this study, the second step of structure elucidation, 13 nominal structures were selected (from a pool of 300 candidate structures) and each with a population contribution proposed for these ions. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Impact of Ion–Ion Correlated Motion on Salt Transport in Solvated Ion Exchange Membranes

The influence of dynamical ion-ion correlations and ion pairing on salt transport in ion exchange membranes remain poorly understood. In this study, we use the framework of Onsager transport coefficients within atomistic molecular dynamics sim- ulations to study the impact of ion-ion correlated motion on salt transport in hydrated polystyrene sulfonate membranes and compare with the results from aqueous salt so- lutions. At sufficiently high salt concentrations, cation-anion dynamical correlations exert a significant influence on both salt diffusivities and conductivities. Anion-anion distinct correlations, arising from the imbalance between the concentration of free (mo- bile) cations and anions, and the retarding effect of the fixed charge groups on cations, proves to be an additional important feature for polymer membranes. Furthermore, our results demonstrate that dynamical correlations should become an important consideration in experimental measurements of salt diffusivities and conductivities for non-dilute salt solutions in polymer membranes.

36 MATERIALS SCIENCE↗

Time-fractional Gardner equation for ion-acoustic waves in negative-ion-beam plasma with negative ions and nonthermal nonextensive electrons

Nonlinear propagation of ion-acoustic waves is investigated in a one-dimensional, unmagnetized plasma consisting of positive ions, negative ions, and nonthermal electrons featuring Tsallis distribution that is penetrated by a negative-ion-beam. The classical Gardner equation is derived to describe nonlinear behavior of ion-acoustic waves in the considered plasma system via reductive perturbation technique. We convert the classical Gardner equation into the time-fractional Gardner equation by Agrawal's method, where the time-fractional term is under the sense of Riesz fractional derivative. Employing variational iteration method, we construct solitary wave solutions of the time-fractional Gardner equation with initial condition which depends on the nonlinear and dispersion coefficients. The effect of the plasma parameters on the compressive and rarefactive ion-acoustic solitary waves is also discussed in detail.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Liquid metal ion source assembly for external ion injection into an electron string ion source (ESIS)

An assembly for a commercial Ga{sup +} liquid metal ion source in combination with an ion transportation and focusing system, a pulse high-voltage quadrupole deflector, and a beam diagnostics system has been constructed in the framework of the iThemba LABS (Cape Town, South Africa)—JINR (Dubna, Russia) collaboration. First, results on Ga{sup +} ion beam commissioning will be presented. Outlook of further experiments for measurements of charge breeding efficiency in the electron string ion source with the use of external injection of Ga{sup +} and Au{sup +} ion beams will be reported as well.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Ion irradiation induced nucleation and growth of nanoparticles in amorphous silicon carbide at elevated temperatures

Ion irradiation induced crystallization in as-deposited amorphous SiC films is investigated using grazing-angle incidence x-ray diffraction (GIXRD), transmission electron microscopy (TEM) and Raman spectroscopy. Irradiation with 5 MeV Xe to fluence of 115 Xe/nm2 at 700 K results in a homogenous distribution of 3C-SiC grains with an average crystallite size of ~5.7 nm over the entire film thickness (~1 µm). The nucleation and growth processes exhibit a weak dependence on dose in displacements per atom (dpa) in the dose range from 6 to 20 dpa. A transformation of homonuclear C-C bonds from sp3 to sp2 hybridization is observed in the irradiated films, which may be partly responsible for the observed grain size saturation. The results from this study may have a significant impact on synthesis of nanograins in amorphous SiC and other similar materials with effective control of grain size and density by ion irradiation.

phase transformation, SiC, ion irradiation↗

Effect of Lithium-Ion Concentration on Morphology and Ion Transport in Single-Ion-Conducting Block Copolymer Electrolytes

Single-ion-conducting polymers are ideal electrolytes for rechargeable lithium batteries as they eliminate salt concentration gradients and concomitant concentration overpotentials during battery cycling. Here in this paper, we study the ionic conductivity and morphology of poly(ethylene oxide)-b-poly(styrenesulfonyllithium(trifluoromethylsulfonyl)imide) (PEO-b-PSLiTFSI) block copolymers with no added salt using ac impedance spectroscopy and small-angle X-ray scattering. The PEO molecular weight was held fixed at 5.0 kg mol -1 , and that of PSLiTFSI was varied from 2.0 to 7.5 kg mol -1 . The lithium ion concentration and block copolymer composition are intimately coupled in this system. At low temperatures, copolymers with PSLiTFSI block molecular weights ≤4.0 kg mol -1 exhibited microphase separation with crystalline PEO-rich microphases and lithium ions trapped in the form of ionic clusters in the glassy PSLiTFSI-rich microphases. At temperatures above the melting temperature of the PEO microphase, the lithium ions were released from the clusters, and a homogeneous disordered morphology was obtained. The ionic conductivity increased abruptly by several orders of magnitude at this transition. Block copolymers with PSLiTFSI block molecular weights ≥5.4 kg mol -1 were disordered at all temperatures, and the ionic conductivity was a smooth function of temperature. The transference numbers of these copolymers varied from 0.87 to 0.99. The relationship between ion transport and molecular structure in single-ion-conducting block copolymer electrolytes is qualitatively different from the well-studied case of block copolymers with added salt.

25 ENERGY STORAGE↗