Search NASA⌕ Search

SEARCH · Search NASA

Results for “ION IMPLANTATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

In-situ observation of sputtered particles for carbon implanted tungsten during energetic isotope ion implantation

Tungsten is a candidate for plasma facing materials in future fusion reactors. During DT plasma operations, carbon as an impurity will bombard tungsten, leading to the formation of tungsten-carbon (WC) layer and affecting tritium recycling behavior. The effect of carbon implantation for the dynamic recycling of deuterium, which demonstrates tritium recycling, including retention and sputtering, has been investigated using in-situ sputtered particle measurements. The C{sup +} implanted W, WC and HOPG were prepared and dynamic sputtered particles were measured during H{sub 2}{sup +} irradiation. It has been found that the major hydrocarbon species for C{sup +} implanted tungsten is CH{sub 3}, while for WC and HOPG (Highly Oriented Pyrolytic Graphite) it is CH{sub 4}. The chemical state of hydrocarbon is controlled by the H concentration in a W-C mixed layer. The amount of C-H bond and the retention of H trapped by carbon atom should control the chemical form of hydrocarbon sputtered by H{sub 2}{sup +} irradiation and the desorption of CH{sub 3} and CH{sub 2} are due to chemical sputtering, although that for CH is physical sputtering. The activation energy for CH{sub 3} desorption has been estimated to be 0.4 eV, corresponding to the trapping process of hydrogen by carbon through the diffusion in W. It is concluded that the chemical states of hydrocarbon sputtered by H{sub 2}{sup +} irradiation for W is determined by the amount of C-H bond on the W surface. (authors)

36 MATERIALS SCIENCE↗

Development of Medium Current Ion Implanter ''IMPHEAT'' for SiC

High productivity medium current ion implanter 'IMPHEAT' was developed for a commercial silicon carbide (SiC) device production. The beamline concept of IMPHEAT is the same as Nissin's ion implanter EXCEED 9600A for silicon device manufacturing. To meet the implantation process for SiC device fabrication, a new type ion source that can produce aluminum (Al) ion beam and a high temperature platen have been developed and installed. The maximum beam currents are 1 mA of Al{sup +}, 400 e{mu}A of Al{sup 2+} and 10 e{mu}A of Al{sup 3+}, and the time variation for these beam currents is less than {+-}10% per hour. The high-temperature platen can handle from 2 to 6 inch wafers. The wafer temperature reaches 600 deg. C for a 6 inch wafer and 500 deg. C for smaller size wafers by using the wafer holder. We have carried out the qualification test and the performance was confirmed as enough for commercial production of SiC devices.

43 PARTICLE ACCELERATORS↗

Highly Stripped Ion Sources for MeV Ion Implantation

Original technical objectives of CRADA number PVI C-03-09 between BNL and Poole Ventura, Inc. (PVI) were to develop an intense, high charge state, ion source for MeV ion implanters. Present day high-energy ion implanters utilize low charge state (usually single charge) ion sources in combination with rf accelerators. Usually, a MV LINAC is used for acceleration of a few rnA. It is desirable to have instead an intense, high charge state ion source on a relatively low energy platform (de acceleration) to generate high-energy ion beams for implantation. This de acceleration of ions will be far more efficient (in energy utilization). The resultant implanter will be smaller in size. It will generate higher quality ion beams (with lower emittance) for fabrication of superior semiconductor products. In addition to energy and cost savings, the implanter will operate at a lower level of health risks associated with ion implantation. An additional aim of the project was to producing a product that can lead to long­ term job creation in Russia and/or in the US. R&D was conducted in two Russian Centers (one in Tomsk and Seversk, the other in Moscow) under the guidance ofPVI personnel and the BNL PI. Multiple approaches were pursued, developed, and tested at various locations with the best candidate for commercialization delivered and tested at on an implanter at the PVI client Axcelis. Technical developments were exciting: record output currents of high charge state phosphorus and antimony were achieved; a Calutron-Bemas ion source with a 70% output of boron ion current (compared to 25% in present state-of-the-art). Record steady state output currents of higher charge state phosphorous and antimony and P ions: P{sup 2+} (8.6 pmA), P{sup 3+} (1.9 pmA), and P{sup 4+} (0.12 pmA) and 16.2, 7.6, 3.3, and 2.2 pmA of Sb{sup 3+} Sb {sup 4 +}, Sb{sup 5+}, and Sb{sup 6+} respectively. Ultimate commercialization goals did not succeed (even though a number of the products like high charge state phosphorus and antimony could have resulted in a lower power consumption of 30 kW/implanter) for the following reasons (which were discovered after R&D completion): record output of high charge state phosphorous would have thermally damage wafers; record high charge state of antimony requires tool (ion implanting machine in ion implantation jargon) modification, which did not make economic sense due to the small number of users. Nevertheless, BNL has benefited from advances in high-charge state ion generation, due to high charge state ions need for RHIC preinjection. High fraction boron ion was delivered to PVI client Axcelis for retrofit and implantation testing; the source could have reduced beam preinjector power consumption by a factor of 3.5. But, since the source generated some lithium (though in miniscule amounts); last minute decision was made not to employ the source in implanters. R&D of novel transport and gasless plasmaless deceleration, as well as decaborane molecular ion source to mitigate space charge problems in low energy shallow ion implantation was also conducted though results were not yet ready for commercialization. Future work should be focused on gasless plasmaless transport and deceleration as well as on molecular ions due to their significance to low energy, shallow implantation; which is the last frontier of ion implantation. To summarize the significant accomplishments: 1. Record steady state output currents of high charge state phosphorous, P, ions in particle milli-Ampere: P{sup 2+} (8.6 pmA), P{sup 3+} (1.9 pmA), and P{sup 4+} (0.12 pmA). 2. Record steady state output currents of high charge state antimony, Sb, ions in particle milli-Ampere: Sb{sup 3+} (16.2 pmA), Sb{sup 4+} (7.6 pmA), Sb{sup 5+} (3.3 pmA), and Sb{sup 6+} (2.2 pmA). 3. 70% output of boron ion current (compared to 25% in present state-of-the-art) from a Calutron-Bemas ion source. These accomplishments have the potential of benefiting the semiconductor manufacturing industry by lowering power consumption by as much as 30 kW per ion implanter. Major problem was meeting commercialization goals did not succeed for the following reasons (which were discovered after R&D completion): record output of high charge state phosphorous would have thermally damage wafers; record high charge state of antimony requires tool (ion implanting machine in ion implantation jargon) modification, which did not make economic sense due to the small number of users. High fraction boron ion was delivered to PVI client Axcelis for retrofit and implantation testing; the source could have reduced beam preinjector power consumption by a factor of 3.5. But, since the source generated some lithium (though in miniscule amounts); last minute decision was made not to employ the source in implanters. An additional noteworthy reason for failure to commercialize is the fact that the ion implantation manufacturing industry had been in a very deep bust cycle. BNL, however, has benefited from advances in high-charge state ion generation, due to the need high charge state ions in some RHIC preinjectors. Since the invention of the transistor, the trend has been to miniaturize semiconductor devices. As semiconductors become smaller (and get miniaturized), ion energy needed for implantation decreases, since shallow implantation is desired. But, due to space charge (intra-ion repulsion) effects, forming and transporting ion beams becomes a rather difficult task. A few small manufacturers of low quality semiconductors use plasma immersion to circumvent the problem. However, in plasma immersion undesired plasma impurity ions are also implanted; hence, the quality of those semiconductors is poor. For high quality miniature semiconductor manufacturing, pure, low energy ion beams are utilized. But, low energy ion implanters are characterized by low current (much lower than desirable) and, therefore, low production rates. Consequently, increasing the current of pure low energy ion beams is of paramount importance to the semiconductor industry. Basically, the semiconductor industry needs higher currents and purer ion low energy beams. Therefore R&D of novel transport and gasless plasmaless deceleration, as well as decaborane molecular ion source to mitigate space charge problems in low energy shallow ion implantation was also conducted though results were not yet ready for commercialization. Future work should be focused on gasless plasmaless transport and deceleration as well as cin molecular ions due to their significance to low energy, shallow implantation, which is the last frontier of ion implantation.

99 GENERAL AND MISCELLANEOUS↗

Structural defects induced by Fe-ion implantation in TiO{sub 2}

X-ray photoelectron spectroscopy and resonant x-ray emission spectroscopy measurements of pellet and thin film forms of TiO{sub 2} with implanted Fe ions are presented and discussed. The findings indicate that Fe-implantation in a TiO{sub 2} pellet sample induces heterovalent cation substitution (Fe{sup 2+} → Ti{sup 4+}) beneath the surface region. But in thin film samples, the clustering of Fe atoms is primarily detected. In addition to this, significant amounts of secondary phases of Fe{sup 3+} are detected on the surface of all doped samples due to oxygen exposure. These experimental findings are compared with density functional theory calculations of formation energies for different configurations of structural defects in the implanted TiO{sub 2}:Fe system. According to our calculations, the clustering of Fe-atoms in TiO{sub 2}:Fe thin films can be attributed to the formation of combined substitutional and interstitial defects. Further, the differences due to Fe doping in pellet and thin film samples can ultimately be attributed to different surface to volume ratios.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Swelling or erosion on the surface of patterned GaN damaged by heavy ion implantation

Wurtzite undoped GaN epilayers (0 0 0 1) was implanted with 500 keV Au+ ions at room temperature under different doses, respectively. Ion implantation was performed through photoresist masks on GaN to produce alternating strips. The experimental results showed that the step height of swelling and decomposition in implanted GaN depended on ion dose and annealing temperature, i.e., damage level and its evolution. This damage evolution is contributed to implantation-induced defect production, and defect migration/accumulation occurred at different levels of displacement per atom. The results suggest that the swelling is due to the formation of porous structures in the amorphous region of implanted GaN. The decomposition of implanted area can be attributed to the disorder saturation and the diffusion of surface amorphous layer.

36 MATERIALS SCIENCE↗

Modulating the Pseudoelastic Response of NiTi Using Ion Implantation

Ni-ion irradiated NiTi is nearly 50% harder, retains 85% recoverable deformation, and has reduced hysteresis. This work explores the feasibility of using ion beam modification to modulate the austenite to martensite phase transformation in NiTi, thereby achieving novel or localized properties in near-surface regions.

36 MATERIALS SCIENCE↗

Modulating the Pseudoelastic Response of NiTi Using Ion Implantation

Ni-ion irradiated NiTi is nearly 50% harder, retains 85% recoverable deformation, and has reduced hysteresis. This work explores the feasibility of using ion beam modification to modulate the austenite to martensite phase transformation in NiTi, thereby achieving novel or localized properties in near-surface regions.

36 MATERIALS SCIENCE↗

Microstructure evolution in carbon-ion implanted sapphire

Carbon ions of MeV energy were implanted into sapphire to fluences of 1x10{sup 17} or 2x10{sup 17} cm{sup -2} and thermally annealed in forming gas (4% H in Ar) for 1 h. Secondary ion mass spectroscopy results obtained from the lower dose implant showed retention of implanted carbon and accumulation of H near the end of range in the C implanted and annealed sample. Three distinct regions were identified by transmission electron microscopy of the implanted region in the higher dose implant. First, in the near surface region, was a low damage region (L{sub 1}) composed of crystalline sapphire and a high density of plateletlike defects. Underneath this was a thin, highly damaged and amorphized region (L{sub 2}) near the end of range in which a mixture of i-carbon and nanodiamond phases are present. Finally, there was a pristine, undamaged sapphire region (L{sub 3}) beyond the end of range. In the annealed sample some evidence of the presence of diamond nanoclusters was found deep within the implanted layer near the projected range of the C ions. These results are compared with our previous work on carbon implanted quartz in which nanodiamond phases were formed only a few tens of nanometers from the surface, a considerable distance from the projected range of the ions, suggesting that significant out diffusion of the implanted carbon had occurred.

36 MATERIALS SCIENCE↗

Hydrophilic property by contact angle change of ion implanted polycarbonate

In this study, ion implantation was performed onto a polymer, polycarbonate (PC), in order to investigate surface hydrophilic property through contact angle measurement. PC was irradiated with N, Ar, and Xe ions at the irradiation energy of 20-50 keV and the dose range of 5x10{sup 15}, 1x10{sup 16}, 7x10{sup 16} ions/cm{sup 2}. The contact angle of water was estimated by means of the sessile drop method and was reduced with increasing fluence and ion mass but increased with increasing implanted energy. The changes of chemical and structural properties are discussed in view of Furier transform infrared and x-ray photoelectron spectroscopy, which shows increasing C-O bonding and C-C bonding. The surface roughness examined by atomic force microscopy measurement changed smoothly from 3.59 to 2.22 A as the fluence increased. It is concluded that the change in wettability may be caused by surface carbonization and oxidation as well as surface roughness.

36 MATERIALS SCIENCE↗

Productivity Improvement for the SHX--SEN's Single-Wafer High-Current Ion Implanter

Equipment productivity is a critical issue for device fabrication. For ion implantation, productivity is determined both by ion current at the wafer and by utilization efficiency of the ion beam. Such improvements not only result in higher fabrication efficiency but also reduce consumption of both electrical power and process gases. For high-current ion implanters, reduction of implant area is a key factor to increase efficiency. SEN has developed the SAVING system (Scanning Area Variation Implantation with Narrower Geometrical pattern) to address this opportunity. In this paper, three variations of the SAVING system are introduced along with discussion of their effects on fab productivity.

36 MATERIALS SCIENCE↗

Fabrication of surface textures by ion implantation for antireflection of silicon crystals

We report on a method based on ion implantation and thermal annealing to fabricate silicon surface textures for antireflection purposes. Modification to crystalline Si surfaces by hydrogen ion implantation is a well known phenomenon, but the surface structures generated by H implantation alone, typically of a low packing density and small aspect ratio, are not effective in suppressing light reflection from Si. We show that coimplantation of hydrogen and argon, combined with thermal annealing and oxidation, can result in an interesting surface morphology in Si crystals, yielding the lowest light reflectance of {approx}1% over a broad spectral range at various light incident angles. In addition, lattice damage to crystalline Si generated by ion implantation is reduced or completely removed by the annealing processes. Possible mechanisms for the formation of such observed surface textures are discussed.

36 MATERIALS SCIENCE↗

Magnetization control for bit pattern formation of spinel ferromagnetic oxides by Kr ion implantation

As a first step toward the development of bit-patterned magnetic media made of oxides, we investigated the effectiveness of magnetism control by Kr implantation in a typical spinel ferromagnetic oxide, Fe{sub 3}O{sub 4}. We implanted Kr ions accelerated at 30 kV on 13-nm-thick Fe{sub 3}O{sub 4} thin films at dosages of (1–40) × 10{sup 14} ions/cm{sup 2}. Magnetization decreased with increase in ion dosages and disappeared when irradiation was greater than 2 × 10{sup 15} ions/cm{sup 2} of Kr ions. These dosages are more than ten times smaller than that used in the N{sub 2} implantation for metallic and oxide ferromagnets. Both the temperature dependence of magnetization and the Mössbauer study suggest that the transition of Fe{sub 3}O{sub 4} from ferromagnetic to paramagnetic took place sharply due to Kr ion irradiation, which produces two-phase separation—ferromagnetic and nonmagnetic with insufficient dosage of Kr ions.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Ion focusing in enhanced glow discharge plasma immersion ion implantation of hydrogen and nitrogen into silicon

Ion focusing in enhanced glow discharge plasma immersion ion implantation (EGD-PIII) of hydrogen into silicon affects the lateral ion fluence uniformity. The phenomenon and its effects are investigated experimentally and theoretically under different conditions and compared to those in nitrogen EGD-PIII. Consistent results are obtained from experiments and numerical simulation disclosing that the lower the plasma density, the more severe is the ion focusing effect. The influence of the negative high voltage on the ion focusing effect is small compared to that of the plasma density.

36 MATERIALS SCIENCE↗

Enhanced conduction in CdSe nanowires on 200 keV phosphorous negative ion implantation

Highlights: • CdSe nanowires were prepared by template assisted electro-deposition. • CdSe nanowires were implanted with 200 keV P{sup −} ions at different fluence. • Structure of CdSe NWs remained intact on ion implantation. • Optical band gap of CdSe NWs decreased after implantation. • The electrical conduction improved due to dominance of ionization effects. - Abstract: For II–VI compound semiconductor nanostructures, ion implantation is considered to be an area of significant interest due to its potential use in the fabrication of the extensive variety of novel optoelectric devices. CdSe nanowires with diameter 80 nm have been grown via the template-assisted electro-deposition method and were subsequently implanted with 200 keV negative phosphorous ions at fluence ranging from 10{sup 11} ions/cm{sup 2} to 10{sup 13} ions/cm{sup 2}. SRIM-TRIM simulation studies are done to understand the course and nature of events occurring during implantation. Pre- and post-implanted samples were characterized by Scanning electron microscope (SEM), X-Ray diffraction (XRD), UV–vis spectroscopy and Probe station with a Keithley source meter. Structural studies reveal no modification in crystal structure upon implantation. An increase of phosphorous content led to an apparent red shift in the optical band gap and an improvement in conductivity. These modifications are attributed to the ionization and the creation of damage on implantation.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Sources and transport systems for low energy extreme of ion implantation

For the past seven years a joint research and development effort focusing on the design of steady state, intense ion sources has been in progress with the ultimate goal being to meet the two, energy extreme range needs of mega-electron-volt and 100's of electron-volt ion implanters. However, since the last Fortier is low energy ion implantation, focus of the endeavor has shifted to low energy ion implantation. For boron cluster source development, we started with molecular ions of decaborane (B{sub 10}H{sub 14}), octadecaborane (B{sub 18}H{sub 22}), and presently our focus is on carborane (C{sub 2}B{sub 10}H{sub 12}) ions developing methods for mitigating graphite deposition. Simultaneously, we are developing a pure boron ion source (without a working gas) that can form the basis for a novel, more efficient, plasma immersion source. Our Calutron-Berna ion source was converted into a universal source capable of switching between generating molecular phosphorous P{sub 4}{sup +}, high charge state ions, as well as other types of ions. Additionally, we have developed transport systems capable of transporting a very large variety of ion species, and simulations of a novel gasless/plasmaless ion beam deceleration method were also performed.

36 MATERIALS SCIENCE↗

Dopant activation in ion implanted silicon by microwave annealing

Microwaves are used as a processing alternative for the electrical activation of ion implanted dopants and the repair of ion implant damage within silicon. Rutherford backscattering spectra demonstrate that microwave heating reduces the damage resulting from ion implantation of boron or arsenic into silicon. Cross-section transmission electron microscopy and selective area electron diffraction patterns demonstrate that the silicon lattice regains nearly all of its crystallinity after microwave processing of arsenic implanted silicon. Sheet resistance readings indicate the time required for boron or arsenic electrical activation within implanted silicon. Hall measurements demonstrate the extent of dopant activation after microwave heating of implanted silicon. Physical and electrical characterization determined that the mechanism of recrystallization in arsenic implanted silicon is solid phase epitaxial regrowth. The boron implanted silicon samples did not result in enough lattice damage to amorphize the silicon lattice and resulted in low boron activation during microwave annealing even though recrystallization of the Si lattice damage did take place. Despite low boron activation levels, the level of boron activation in this work was higher than that expected from traditional annealing techniques. The kinetics of microwave heating and its effects on implanted Si are also discussed.

36 MATERIALS SCIENCE↗

Modeling the impact of radiation-enhanced diffusion on implanted ion profiles

We report that ion irradiations are a valuable research tool for exploring radiation effects in materials. However, it is well recognized that the implanted ions can artificially modify the radiation damage evolution, e.g., enhancing amorphization processes at low irradiation temperatures and suppressing void swelling at elevated temperatures. Therefore, the implanted ion region should be avoided for most studies of ion irradiated materials. Due to increased interest in high damage, high temperature ion irradiations studying radiation effects in materials for proposed high dose Generation IV fission and fusion energy applications, it is crucial to quantify the extent of diffusional broadening of the implanted ion profile for a variety of temperatures, irradiation fluxes, and sink strengths. The present study summarizes computational analyses of thermal and depth-dependent radiation enhanced difusion (RED) on diffusion broadening of the implanted ion profiles in Fe and Ni for a variety of irradiation conditions. For a low assumed RED coefficient (10 -20 -10 -19 m 2 /s and 10 -4 and 10 -3 peak dpa/s, respectively) or high flux, broadening of the as-implanted ion profile is very small and a suitable artifact-free midrange region for analysis exists for ion energies above 5-6 MeV at 100 peak dpa. At high RED coefficients (10 -19 -10 -18 m 2 /s and 10 -4 and 10 -3 peak dpa/s, respectively) broadening is much more significant, and no valid region for investigation exists below 6-8 MeV ion energies at any damage level >50 dpa. While increasing flux decreases irradiation time, it also increases the RED coefficient; these effects mostly offset except under recombination-dominant conditions. For typical high dose irradiation studies of void swelling that exceed ~100 displacement per atom (dpa), ion energies > 6-8 MeV must be employed in order to achieve suitable artifact-free midrange irradiation analysis regions, depending on the material system. Lastly, analysis of amorphization/precipitation require even higher energies (>10 MeV).

07 ISOTOPE AND RADIATION SOURCES↗

Method For Silicon Surface Texturing Using Ion Implantation

As the semiconductor industry continues to show more interest in the photovoltaic market, cheaper and readily integrable methods of silicon solar cell production are desired. One of these methods - ion implantation - is well-developed and optimized in all commercial semiconductor fabrication facilities. Here we have developed a silicon surface texturing technique predicated upon the phenomenon of surface blistering of H-implanted silicon, using only ion implantation and thermal annealing. We find that following the H implant with a second, heavier implant markedly enhances the surface blistering, causing large trenches that act as a surface texturing of c-Si. We have found that this method reduces total broadband Si reflectance from 35% to below 5percent;. In addition, we have used Rutherford backscattering/channeling measurements investigate the effect of ion implantation on the crystallinity of the sample. The data suggests that implantation-induced lattice damage is recovered upon annealing, reproducing the original monocrystalline structure in the previously amorphized region, while at the same time retaining the textured surface.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗