Imaging systems and materials characterization

This paper provides a broad background for the historical development and modern applications of light optical metallography, scanning and transmission electron microscopy, field-ion microscopy and several forms of scanning probe microscopes. Numerous case examples illustrating especially synergistic applications of these imaging systems are provided to demonstrate materials characterization especially in the context of structure-property-performance issues which define materials science and engineering.

36 MATERIALS SCIENCE↗

Phase modulation mode of scanning ion conductance microscopy

This Letter reports a phase modulation (PM) mode of scanning ion conductance microscopy. In this mode, an AC current is directly generated by an AC voltage between the electrodes. The portion of the AC current in phase with the AC voltage, which is the current through the resistance path, is modulated by the tip-sample distance. It can be used as the input of feedback control to drive the scanner in Z direction. The PM mode, taking the advantages of both DC mode and traditional AC mode, is less prone to electronic noise and DC drift but maintains high scanning speed. The effectiveness of the PM mode has been proven by experiments.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Subsurface Examination of a Foliar Biofilm Using Scanning Electron- and Focused-Ion-Beam Microscopy

The dual beam scanning electron microscope, equipped with both a focused ion- and scanning electron- beam (FIB SEM) is a novel tool for the exploration of the subsurface structure of biological tissues. The FIB can remove a predetermined amount of material from a selected site to allow for subsurface exploration and when coupled with SEM or scanning ion- beam microscopy (SIM) could be suitable to examine the subsurface structure of bacterial biofilms on the leaf surface. The suitability of chemical and cryofixation was examined for use with the FIB SEM to examine bacterial biofilms on leaf surfaces. The biological control agent, Burkholderia pyroccinia FP62, that rapidly colonizes the leaf surface and forms biofilms, was inoculated onto geranium leaves and incubated in a greenhouse for 7 or 14 days. Cryofixation was not suitable for examination of leaf biofilms because it created a frozen layer over the leaf surface that cracked when exposed to the electron beam and the protective cap required for FIB milling could not be accurately deposited. With chemically fixed samples, it was possible to precisely FIB mill a single cross section (5 µm) or sequential cross sections from a single site without any damage to the surrounding surface. Biofilms, 7 days post-inoculation (DPI), were composed of 2 to 5 bacterial cell layers while biofilms 14 DPI ranged from 5 to greater than 30 cell layers. Empty spaces between bacteria cells in the subsurface structure were observed in biofilms 7- and 14-DPI. Sequential cross sections inferred that the empty spaces were often continuous between FP62 cells and could possibly make up a network of channels throughout the biofilm. FIB SEM was a useful tool to observe the subsurface composition of a foliar biofilm.

54 ENVIRONMENTAL SCIENCES↗

Trace element content and magnetic properties of commercial HOPG samples studied by ion beam microscopy and SQUID magnetometry

In this study, the impurity concentration and magnetic response of nine highly oriented pyrolytic graphite (HOPG) samples with different grades and from different providers were determined using ion beam microscopy and SQUID magnetometry. Apart from sideface contaminations in the as-received state, bulk contamination of the samples in most cases consists of disk-shaped micron-sized particles made of Ti and V with an additional Fe contamination around the grain perimeter. The saturation magnetization typically increases with Fe concentration, however, there is no simple correlation between Fe content and magnetic moment. The saturation magnetization of one, respectively six, out of nine samples clearly exceeds the maximum contribution from pure Fe or Fe{sub 3}C. For most samples the temperature dependence of the remanence decreases linearly with T – a dependence found previously for defect-induced magnetism (DIM) in HOPG. We conclude that apart from magnetic impurities, additional contribution to the ferromagnetic magnetization exists in pristine HOPG in agreement with previous studies. A comparative study between the results of ion beam microscopy and the commonly used EDX analysis shows clearly that EDX is not a reliable method for quantitative trace elemental analysis in graphite, clarifying weaknesses and discrepancies in the element concentrations given in the recent literature.

36 MATERIALS SCIENCE↗

Preparation and electrical conductivity of graphitic carbon-infused copper alloys

By electron-beam (e-beam) melting, we prepared 0.4 wt% carbon-infused copper (CuCv4), and a copper control without carbon addition (CuCv0). Scanning electron microscopy and helium ion microscopy (HIM) were performed on the as-solidified surface, fracture surface, and ion-polished surface of the CuCv4 sample. The results revealed that graphitic carbon flakes cover the as-solidified surface, and carbon nanoparticles and clusters exist in the fracture and ion-polished surfaces. HIM on the ion-polished surface revealed a unique ripple-shaped feature, which is possibly associated with the infusion of carbon nanoribbons in the copper matrix. The bulk densities were measured to be 8.86 and 8.53 g/cm 3 , which correspond to relative densities of 98.9% and 96.4% for the CuCv0 and CuCv4 samples, respectively. Also, apparent electrical conductivities were measured to be 56.9 and 57.5 MS/m, respectively, for the e-beam melted CuCv0 and CuCv4 samples. These values correspond to true electrical conductivities of 100.5% IACS (International Annealed Copper Standard) and 107.4% IACS after correction for the porosity. Thus, our results reveal remarkable promise of using covetic copper for the next generation conductors in energy applications from microelectronic devices to high-power transmission cables.

36 MATERIALS SCIENCE↗

A comparison of He and Ne FIB imaging of cracks in microindented silicon nitride

Highlights: • Silicon nitride was successfully imaged with helium and neon ion microscopy. • Indent-induced cracking was resolved on conductively-coated and uncoated samples. • Cracking was found to be primarily intergranular in nature. • The grain microstructure was most visible on the carbon-coated sample. • For the carbon-coated sample, localized charging was observed along crack pathways. - Abstract: Helium ion microscopy (HIM) offers potential as a high spatial resolution technique for imaging insulating samples that are susceptible to charging artifacts. In this study helium and neon ion microscopy are used to image cracking in microindented samples of the non-conductive ceramic silicon nitride. The crack morphology of radial cracks emanating from the microindentations has been characterized for two different compositions of silicon nitride, with and without conductive coatings. Gold coating enhances crack edge contrast, but masks grain contrast for both He and Ne ion-induced secondary electron (ISE) imaging. Carbon coating enables the crystalline and glassy phases to be distinguished, more clearly with Ne-ISE, and the cracking pathway is found to be primarily intergranular. Zones of <100 nm diameter depleted ion-induced secondary electron emission along the crack paths are identified, consistent with charging ‘hotspots’.

36 MATERIALS SCIENCE↗

Scanning He+ Ion Beam Microscopy and Metrology

The CD-SEM has been the tool of choice for the imaging and metrology of semiconductor devices for the past three decades but now, with critical dimensions at the nanometer scale, electron beam instruments can no longer deliver adequate performance. A scanning microscope using a He+ ion beam offers superior resolution and depth of field, and provides enhanced imaging contrast. Device metrology performed using ion beam imaging produces data which is comparable to or better than that from a conventional CD-SEM although there are significant differences in the experimental conditions required and in the details of image formation. The charging generated by a He+ beam, and the sample damage that it can cause, require care in operation but are not major problems.

36 MATERIALS SCIENCE↗

Structure and properties of solid surfaces

Difficulties in experimental studies of crystalline surfaces are related to the fact that surface atoms have an intrinsic tendency to react with their environment. A second problem is connected with the effective thickness of surfaces, which ranges from one to several atom layers. The phenomenology of surface interactions with gases are considered, taking into account physical adsorption, chemisorption, and the oxidation of surfaces. Studies of the surface structure are discussed, giving attention to field emission microscopy, field-ion microscopy, electron diffraction techniques, Auger spectroscopy, scanning electron microscopy, electron probe microanalysis, ion microprobe methods, and low-energy backscattering spectroscopy. Investigations of semiconductor surfaces are also described.

Gatos, H. C.↗

Final Technical Report for DE-FG02-06ER15835: Chemical Imaging with 100nm Spatial Resolution: Combining High Resolution Flurosecence Microscopy and Ion Mobility Mass Spectrometry

We have combined, in a single instrument, high spatial resolution optical microscopy with the chemical specificity and conformational selectivity of ion mobility mass spectrometry. We discuss the design and construction of this apparatus as well as our efforts in applying this technique to thin films of molecular semiconductor materials.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Interface characteristics of n-n and p-n Ge/SiC heterojunction diodes formed by molecular beam epitaxy deposition

In this article, we report on the physical and electrical nature of Ge/SiC heterojunction layers that have been formed by molecular beam epitaxy (MBE) deposition. Using x-ray diffraction, atomic force microscopy, and helium ion microscopy, we perform a thorough analysis of how MBE growth conditions affect the Ge layers. We observe the layers developing from independent islands at thicknesses of 100 nm to flat surfaces at 300 nm. The crystallinity and surface quality of the layer is shown to be affected by the deposition parameters and, using a high temperature deposition and a light dopant species, the layers produced have large polycrystals and hence a low resistance. The p-type and n-type layers, 300 nm thick are formed into Ge/SiC heterojunction mesa diodes and these are characterized electrically. The polycrystalline diodes display near ideal diode characteristics (n<1.05), low on resistance and good reverse characteristics. Current-voltage (I-V) measurements at varying temperature prove that all the layers have two-dimensional fluctuations in the Schottky barrier height (SBH) due to inhomogeneities at the heterojunction interface. Capacitance-voltage analysis and the SBH size extracted from I-V analysis suggest strongly that interface states are present at the surface causing Fermi-level pinning throughout the bands. A simple model is used to quantify the concentration of interface states at the surface.

36 MATERIALS SCIENCE↗

Focused Ion Beam Microscopy of ALH84001 Carbonate Disks

Our aim is to understand the mechanism(s) of formation of carbonate assemblages in ALH84001. A prerequisite is that a detailed characterization of the chemical and physical properties of the carbonate be established. We present here analyses by transmission electron microscopy (TEM) of carbonate thin sections produced by both focused ion beam (FIB) sectioning and ultramicrotomy. Our results suggest that the formation of ALH84001 carbonate assemblages were produced by considerably more complex process(es) than simple aqueous precipitation followed by partial thermal decomposition as proposed by other investigators [e.g., 1-3].

Thomas-Keprta, Kathie L.↗

Ion beam modification of topological insulator bismuth selenide

In this study, we demonstrate chemical doping of a topological insulator Bi 2 Se 3 using ion implantation. Ion beam-induced structural damage was characterized using grazing incidence X-ray diffraction and transmission electron microscopy. Ion damage was reversed using a simple thermal annealing step. Carrier-type conversion was achieved using ion implantation followed by an activation anneal in Bi 2 Se 3 thin films. These two sets of experiments establish the feasibility of ion implantation for chemical modification of Bi 2 Se 3 , a prototypical topological insulator. Ion implantation can, in principle, be used for any topological insulator. The direct implantation of dopants should allow better control over carrier concentrations for the purposes of achieving low bulk conductivity. Ion implantation also enables the fabrication of inhomogeneously doped structures, which in turn should make possible new types of device designs.

36 MATERIALS SCIENCE↗

Separation Nanotechnology of Diethylenetriaminepentaacetic Acid Bonded Magnetic Nanoparticles for Spent Nuclear Fuel

A nanomagnetic separation method based on Diethylenetriaminepentaacetic acid (DTPA) conjugated with magnetic nanoparticles (MNPs) is studied for application in spent nuclear fuel separation. The high affinity of DTPA towards actinides aids in separation from the highly acidic medium of nuclear waste. The solubility and magnetization of particles at low pH is protected by encapsulating them in silica layer. Surface functionalization of silica coated particles with polyamines enhances the loading capacity of the chelators on MNPs. The particles were characterized before and after surface modification using transmission electron microscopy (TEM), helium ion microscopy (HIM), Fourier transform-infrared (FT-IR) spectrometry, and X-ray diffractometry. The coated and uncoated samples were studied using vibrating sample magnetometer (VSM) to understand the change in magnetic properties due to the influence of the surface functionalization. The hydrodynamic size and surface charge of the particles are investigated using Dynamic Light Scattering (DLS). The uptake behavior of Am(III), Pu(IV), U(VI), and Np(V) from 0.1M NaNO3 solution was investigated. The sorption result shows the strong affinity of DTPA towards Am(III) and Pu(IV) by extracting 97% and 80% of actinides, respectively. The high removal efficiency and fast uptake of actinides make the chelator conjugated MNPs an effective method for spent nuclear fuel separation.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

In-situ spectroscopic ellipsometry for real-time characterization of the effects of high-flux helium plasmas on tungsten surfaces

Tungsten samples were exposed to He plasmas generated by an RF source (Γ i = 3.5 x 10 16 He cm -2 s -1 , ion energy = 92 eV.) The range of exposure conditions selected here is conducive to the growth of nearsurface He bubbles, and at higher fluence, the formation of W nanotendrils ranging between 50 — 100 nm in diameter. The evolution of these surface features was probed using a fixed-angle ellipsometer (280 — 1000 nm wavelength range) with direct line-of-sight to the sample. Over the parameter space explored here, changes in the two angles (p, S) that define the polarization of the reflected light followed a distinct trajectory with increasing plasma fluence. Ex-situ ellipsometry of 22 additional tungsten specimens tested at a wide range of plasma fluences and temperatures mapped onto these in-situ results well. We used helium ion microscopy and focused ion beam profiling to provide a direct calibration of the ellipsometry measurements. Our results indicate that for a reproducible process such as the growth helium-induced surface morphologies, ellipsometry is a practical in-situ diagnostic to study how fusion plasmas modify materials. To study more general effects of plasmas on surfaces, including co-deposition and sputtering, different approaches to modelling the optical properties of the exposed surfaces are also considered.

36 MATERIALS SCIENCE↗

Growth process of gamma'-particles in a liquid-quenched Ni-15 at percent Al alloy

The growth of gamma-prime particles in a supersaturated Ni-15 at% Al alloy prepared by the liquid-quench method was studied using a magnetic mass balance, transmission electron microscopy, and field ion microscopy. Three stages in the precipitation and growth of these particles are demonstrated. In the first phase, the gamma-prime phase was produced by nucleation of spinodal decomposition of the alloy. In the second stage, spherical gamma-prime particles were arranged at random in the matrix with the size independent of aging time. Then, the Al concentration in the matrix decreased with the -1/3 power of the aging time. These results suggest that the degree of ordering increases with aging time. In the third stage, the particles were coarsened with aging time. They were arranged in the matrix (100) zone and were cubic, with the cube face lying on (100). The interfacial free energy was 28.4 mJ/sq m at 873 K and 22.4 mJ/sq m at 973 K.

Tachikake, A.↗

Thermal Desulfurization of Petroleum Coke for Anode Use

Thermal desulfurization (TDS) of petroleum coke during calcination is a well-known phenomenon which results in an increase in porosity and decrease in bulk density. Rain Carbon presented a paper recently which explored the potential of using a shaft calciner to TDS coke instead of a rotary kiln calciner. There are some significant benefits in using a shaft calciner due to the slower heat-up rate but the coke structure is still irreversibly changed when sulphur (S) is driven from the coke. This paper presents a review of the differences in TDS at different heating rates and includes high resolution scanning electron microscopy and helium ion microscopy images. The potential for TDS petroleum coke to allow a wider range of GPC raw materials to be used for anode production is discussed. At least one coke calcining company in China has attempted aggressive TDS on a production scale. High S cokes are readily available and cheaper than low S cokes and removing SO2 during calcination is more efficient than removing SO2 from potroom flue-gas streams to meet emission limits. There are significant practical limits to the level of TDS that can be tolerated however, both from a calciner’s perspective and for anode quality/performance reasons.

Edwards, Les↗

Noble gas ion beams in materials science for future applications and devices

Helium ion microscopy (HIM), enabled by a gas field ion source (GFIS), is an emerging imaging and nanofabrication technique compatible with many applications in materials science. The scanning electron microscope (SEM) has become ubiquitous in materials science for high-resolution imaging of materials. However, due to the fundamental limitation in focusing of electron beams, ion-beam microscopy is now being developed (e.g., at 20 kV the SEM beam diameter ranges from 0.5 to 1 nm, whereas the HIM offers 0.35 nm). The key technological advantage of the HIM is in its multipurpose design that excels in a variety of disciplines. The HIM offers higher resolution than the best available SEMs as well as the traditional gallium liquid-metal ion source (LMISs) focused ion beams (FIBs), and is capable of imaging untreated biological or other insulating samples with unprecedented resolution, depth of field, materials contrast, and image quality. GFIS FIBs also offer a direct path to defect engineering via ion implantation, three-dimensional direct write using gaseous and liquid precursors, and chemical-imaging options with secondary ion mass spectrometry. HIM covers a wide range of tasks that otherwise would require multiple tools or specialized sample preparation. In this paper, we describe the underlying technology, present materials, relevant applications, and offer an outlook for the potential of FIB technology in processing materials.

2D materials↗

Automation of Laser Plasma Focused Ion Beam Microscopy for Next-Gen Energy Materials

Automation can revolutionize the use of ultrafast laser ablation and plasma-focused ion beam (PFIB) techniques for high-throughput, reproducible cross-sectioning and various sample preparation in materials characterization. As these methods become essential for analyzing complex energy materials and next-generation devices, efficient, standardized workflows are needed to minimize variability and enhance precision. This work highlights our advancements in developing automated processes for sample preparation that integrates machine learning, workflow optimization, and large-scale data acquisition to improve efficiency and scalability in applications such as electrolyzers, photovoltaic cells, and microelectronics. To streamline cross-sectioning and lamella fabrication, we have implemented fully automated workflows that standardize laser ablation and PFIB milling sequences. These workflows incorporate pre-programmed protocols for material removal, alignment, and thinning, reducing user intervention and ensuring consistency across different sample types. Machine learning algorithms further enhance automation by predicting optimal milling strategies and adapting parameters based on material properties and sectioning requirements. This approach significantly improves throughput while maintaining the structural integrity of prepared samples for high-resolution imaging and analysis, including transmission electron microscopy. Beyond sample preparation, our automation platform enables the acquisition of large, high-resolution datasets through serial sectioning, image alignment, and 3D reconstruction. These automated routines facilitate multi-scale characterization, capturing structural and compositional details from the nanoscale to the device level. By reducing variability and increasing efficiency, our automated approach enhances defect analysis, failure diagnostics, and process optimization, accelerating advancements in materials research and device engineering.

36 MATERIALS SCIENCE↗