Concomitant ion effects on isotope ratio measurements with liquid sampling – atmospheric pressure glow discharge ion source Orbitrap mass spectrometry
RATIONALE: The field of highly accurate and precise isotope ratio (IR) analysis has been dominated by inductively coupled plasma and thermal ionization mass spectrometers. While these instruments are considered the gold standard for IR analysis, the International Atomic Energy Agency desires a field deployable instrument capable of accurately and precisely measuring U isotope ratios. METHODS: The proposed system interfaces the liquid sampling – atmospheric pressure glow discharge (LS-APGD) ion source with a high resolution Exactive Orbitrap mass spectrometer. With this experimental setup certified U isotope standards and unknown samples were analyzed. The accuracy and precision of the system were then determined. RESULTS: The LS-APGD /Exactive instrument measures a certified reference material of natural U (235U/238U = 0.007258) as 0.007041 with a relative standard deviation of 0.158% meeting the International Target Values for Uncertainty for the destructive analysis of U. Additionally, when three unknowns measured and compared to the results from an ICP multi collector instrument, there is no statistical difference between the two instruments. CONCLUSIONS: The LS-APGD / Orbitrap system, while still in the preliminary stages of development, offers highly accurate and precise IR analysis that suggest a paradigm shift in the world of IR analysis. Furthermore, the portability of the LS-APGD as an elemental ion source combined with the low overhead and small size of the Orbitrap suggest that the instrumentation is capable of being field deployable. With liquid sampling glow discharge-Orbitrap MS, isotope ratio and precision performance improves with rejection of concomitant ion species.
Reply to "Comment on 'A Self-Consistent Model of the Interacting Ring Current Ions and Electromagnetic Ion Cyclotron Waves, Initial Results: Waves and Precipitation Fluxes' and 'Self-Consistent Model of the Magnetospheric Ring Current and Propagating Electromagnetic Ion Cyclotron Waves: Waves in Multi-Ion Magnetosphere' by Khazanov et al. et al."
It is well-known that the effects of electromagnetic ion cyclotron (EMIC) waves on ring current (RC) ion and radiation belt (RB) electron dynamics strongly depend on such particle/wave characteristics as the phase-space distribution function, frequency, wavenormal angle, wave energy, and the form of wave spectral energy density. The consequence is that accurate modeling of EMIC waves and RC particles requires robust inclusion of the interdependent dynamics of wave growth/damping, wave propagation, and[ particles. Such a self-consistent model is being progressively developed by Khazanov et al. [2002, 2006, 2007]. This model is based on a system of coupled kinetic equations for the RC and EMIC wave power spectral density along with the ray tracing equations. Thome and Home [2007] (hereafter referred to as TH2007) call the Khazanov et al. [2002, 2006] results into question in their Comment. The points in contention can be summarized as follows. TH2007 claim that: (1) "the important damping of waves by thermal heavy ions is completely ignored", and Landau damping during resonant interaction with thermal electrons is not included in our model; (2) EMIC wave damping due to RC O + is not included in our simulation; (3) non-linear processes limiting EMIC wave amplitude are not included in our model; (4) growth of the background fluctuations to a physically significantamplitude"must occur during a single transit of the unstable region" with subsequent damping below bi-ion latitudes,and consequently"the bounce averaged wave kinetic equation employed in the code contains a physically erroneous 'assumption". Our reply will address each of these points as well as other criticisms mentioned in the Comment. TH2007 are focused on two of our papers that are separated by four years. Significant progress in the self-consistent treatment of the RC-EMIC wave system has been achieved during those years. The paper by Khazanov et al. [2006] presents the latest version of our model, and in this Reply we refer mostly to this paper.
NASA Aerospace Flight Battery Program: Generic Safety, Handling and Qualification Guidelines for Lithium-Ion (Li-Ion) Batteries; Availability of Source Materials for Lithium-Ion (Li-Ion) Batteries; Maintaining Technical Communications Related to Aerospace Batteries (NASA Aerospace Battery Workshop)
This NASA Aerospace Flight Battery Systems Working Group was chartered within the NASA Engineering and Safety Center (NESC). The Battery Working Group was tasked to complete tasks and to propose proactive work to address battery related, agency-wide issues on an annual basis. In its first year of operation, this proactive program addressed various aspects of the validation and verification of aerospace battery systems for NASA missions. Studies were performed, issues were discussed and in many cases, test programs were executed to generate recommendations and guidelines to reduce risk associated with various aspects of implementing battery technology in the aerospace industry. This document contains Part 1 - Volume I: Generic Safety, Handling and Qualification Guidelines for Lithium-Ion (Li-Ion) Batteries, Availability of Source Materials for Lithium-Ion (Li-Ion) Batteries, and Maintaining Technical Communications Related to Aerospace Batteries (NASA Aerospace Battery Workshop).
Anomalous grain growth in the surface region of a nanocrystalline CeO2 film under low-temperature heavy ion irradiation
Grain growth and phase stability of nanocrystalline ceria are investigated under ion irradiation at different temperatures. Irradiations at temperatures of 300 and 400 K result in uniform grain growth throughout the film. Anomalous grain growth is observed in thin films of nanocrystalline ceria under 3 MeV Au+ irradiation at 160 K. At this low temperature, significant grain growth is observed within 100 nm from the surface, no obvious growth is detected in the rest of the films. While the grain growth is attributed to a defect-stimulated mechanism at room temperature and above, a defect diffusion-limited mechanism is significant at low temperature with the primary defect responsible being the oxygen vacancy. The nanocrystalline grains remain in the cubic phase regardless of defect kinetics.
Improved charge breeding efficiency of light ions with an electron cyclotron resonance ion source
The Californium Rare Isotope Breeder Upgrade is a new radioactive beam facility for the Argonne Tandem Linac Accelerator System (ATLAS). The facility utilizes a {sup 252}Cf fission source coupled with an electron cyclotron resonance ion source to provide radioactive beam species for the ATLAS experimental program. The californium fission fragment distribution provides nuclei in the mid-mass range which are difficult to extract from production targets using the isotope separation on line technique and are not well populated by low-energy fission of uranium. To date the charge breeding program has focused on optimizing these mid-mass beams, achieving high charge breeding efficiencies of both gaseous and solid species including 14.7% for the radioactive species {sup 143}Ba{sup 27+}. In an effort to better understand the charge breeding mechanism, we have recently focused on the low-mass species sodium and potassium which up to present have been difficult to charge breed efficiently. Unprecedented charge breeding efficiencies of 10.1% for {sup 23}Na{sup 7+} and 17.9% for {sup 39}K{sup 10+} were obtained injecting stable Na{sup +} and K{sup +} beams from a surface ionization source.
Electronic stopping powers for heavy ions in SiC and SiO{sub 2}
Accurate information on electronic stopping power is fundamental for broad advances in materials science, electronic industry, space exploration, and sustainable energy technologies. In the case of slow heavy ions in light targets, current codes and models provide significantly inconsistent predictions, among which the Stopping and Range of Ions in Matter (SRIM) code is the most commonly used one. Experimental evidence, however, has demonstrated considerable errors in the predicted ion and damage profiles based on SRIM stopping powers. In this work, electronic stopping powers for Cl, Br, I, and Au ions are experimentally determined in two important functional materials, SiC and SiO{sub 2}, based on a single ion technique, and new electronic stopping power values are derived over the energy regime from 0 to 15 MeV, where large deviations from the SRIM predictions are observed. As an experimental validation, Rutherford backscattering spectrometry (RBS) and secondary ion mass spectrometry (SIMS) are utilized to measure the depth profiles of implanted Au ions in SiC for energies from 700 keV to 15 MeV. The measured ion distributions by both RBS and SIMS are considerably deeper than the SRIM predictions, but agree well with predictions based on our derived stopping powers.
Ordered and Disordered Polymorphs of Na(Ni 2/3 Sb 1/3 )O 2 : Honeycomb-Ordered Cathodes for Na-Ion Batteries
Explore the source record for details and available documents.
Focused Ion Beam Fabrication of LiPON-based Solid-state Lithium-ion Nanobatteries for In Situ Testing
Solid-state electrolytes are a promising replacement for current organic liquid electrolytes, enabling higher energy densities and improved safety of lithium-ion (Li-ion) batteries. However, a number of setbacks prevent their integration into commercial devices. The main limiting factor is due to nanoscale phenomena occurring at the electrode/electrolyte interfaces, ultimately leading to degradation of battery operation. These key problems are highly challenging to observe and characterize as these batteries contain multiple buried interfaces. One approach for direct observation of interfacial phenomena in thin film batteries is through the fabrication of electrochemically active nanobatteries by a focused ion beam (FIB). As such, a reliable technique to fabricate nanobatteries was developed and demonstrated in recent work. Herein, a detailed protocol with a step-by-step process is presented to enable the reproduction of this nanobattery fabrication process. In particular, this technique was applied to a thin film battery consisting of LiCoO 2 /LiPON/a-Si, and has further been previously demonstrated by in situ cycling within a transmission electron microscope.
Tuning the Solid Electrolyte Interphase for Selective Li‐ and Na‐Ion Storage in Hard Carbon
Solid‐electrolyte interphase (SEI) films with controllable properties are highly desirable for improving battery performance. In this paper, a combined experimental and theoretical approach is used to study SEI films formed on hard carbon in Li‐ and Na‐ion batteries. It is shown that a stable SEI layer can be designed by precycling an electrode in a desired Li‐ or Na‐based electrolyte, and that ionic transport can be kinetically controlled. Selective Li‐ and Na‐based SEI membranes are produced using Li‐ or Na‐based electrolytes, respectively. The Na‐based SEI allows easy transport of Li ions, while the Li‐based SEI shuts off Na‐ion transport. Na‐ion storage can be manipulated by tuning the SEI layer with film‐forming electrolyte additives, or by preforming an SEI layer on the electrode surface. The Na specific capacity can be controlled to < 25 mAh g −1 ; ≈ 1/10 of the normal capacity (250 mAh g −1 ). Unusual selective/preferential transport of Li ions is demonstrated by preforming an SEI layer on the electrode surface and corroborated with a mixed electrolyte. This work may provide new guidance for preparing good ion‐selective conductors using electrochemical approaches.
Accumulation of Large Ion Populations with High Ion Densities and Effects Due to Space Charge in Traveling Wave-Based Structures for Lossless Ion Manipulations (SLIM) IMS-MS
The accumulation of very large ion populations in traveling wave (TW)-based Structures for Lossless ion Manipulations (SLIM) has been studied to better understand aspects of ‘in-SLIM’ ion accumulation, and particularly its use in conjunction with ion mobility spectrometry (IMS). A linear SLIM ion path was implemented that had a ‘gate’ for blocking and accumulating ions for arbitrary time periods. Removing the gate potential caused ions to exit and the spatial distributions of accumulated ions were examined. The ion populations for a set of peptides were observed to increase with increased accumulation times until space change effects became significant, after which the peptide precursor ion populations decreased due to growing space charge-related ion activation, reactions, and losses. Ions closest to the gate were preferentially activated, and increasingly so with added storage times, TW amplitude, and the size of the total ion population. For analytical applications, we found that relatively weak TWs in the accumulation/storage region should be utilized to prevent or minimize ion losses and/or ion heating effects that can also lead to fragmentation. Our results further indicate that an accumulation region close to the SLIM entrance is advantageous for both speeding accumulation, minimizing ion heating, and avoiding ion population profiles that result in IMS peak tailing. Importantly, space charge-driven separations were observed for large populations of accumulated species and attributed to the opposing effects of space charge and the TW. In these separations, ion species form distributions or peaks, sometimes moving against the TW, and ordered in the SLIM based on their mobilities. Such separations may offer utility for ion pre-fractionation of ions and increasing the dynamic range measurements, increasing the resolving power of IMS separations by decreasing peak widths for accumulated ion populations, and other purposes benefitting from separations of extremely large ion populations.
In situ high-energy synchrotron X-ray diffraction revealing precipitation reaction kinetics of silver ions with mixed halide ions
Precipitation of silver ions simultaneously with chloride and bromide ions in ethylene glycol at a mild temperature (e.g., 60 degrees C) has been successfully demonstrated for the synthesis of silver chlorobromide (AgClxBr1-x, 0 < x < 1) nanoparticles, which is realized by injecting a AgNO3 solution into a solution containing both halogen ions. The injection rate of the AgNO3 solution has been determined to be critical for controlling the uniformity of AgClxBr1-x nanoparticles. Time-resolved in situ high-energy synchrotron X-ray diffraction has been applied, for the first time, to quantitatively monitor the reaction kinetics of nanocrystal formation. The real-time results shed light on the fact that the injection rate of AgNO3 solution significantly influences the nucleation and growth processes, and thus the quality of resulting AgClxBr1-x nanoparticles. Specifically, fast injection enables the complete addition of AgNO3 solution to the reaction solution before the nucleation process starts, leading to a good separation of nucleation and growth and thus the formation of uniform AgClxBr1-x nanocubes with well-defined composition and narrow size distribution. By contrast, slow injection results in a continuous addition of AgNO3 solution to the reaction solution even after nucleation starts, leading to continuous multiple nucleation/growth processes and thus the formation of AgClxBr1-x nanoparticles with broad dimensional and morphological distributions.
Cluster ion source for external injection and high capacity filling of light elements into the relativistic heavy ion collider electron beam ion source
An advanced Electron Beam Ion Source (EBIS) is the primary ion source to supply highly charged ion beams of different elements to the Relativistic Heavy Ion Collider (RHIC) and to the NASA Space Radiation Laboratory (NSRL). Intense beams of highly charged ions of various elements of the periodic table, ranging from helium to uranium, have been demonstrated since EBIS became operational in 2010. EBIS routinely provides ion beams to RHIC and NSRL quasisimultaneously with about 1 s switching time between different ion species. Such unique flexibility and rapid switching between ion species are based on external injection of singly charged ions into the EBIS trap either in “fast” or “slow” injection modes. At present, a Laser Ion Source (LIS) provides most of the ion species of solid materials using the “fast” injection mode into the EBIS trap and a Hollow Cathode Ion Source (HCIS) provides most of the ion species of gaseous elements using the “slow” injection mode into the EBIS trap. Gas injection into the EBIS trap is also possible and has been used but imposes some restrictions for the simultaneous generation of highly charged ions such as Au 32+ ions for RHIC and ions of gaseous species for NSRL. Because light ions have relatively high velocity inside the EBIS trap, efficient injection of hydrogen and helium ions and filling of the EBIS trap to high capacity is difficult from either LIS or HCIS. To overcome this restriction and enhance EBIS operational capability, we suggest injecting beams of hydrogen and helium cluster ions into the EBIS trap. Required parameters of cluster ion beam injection into the EBIS trap are estimated, and advantages of such an injection are highlighted. A cluster ion source with required high intensity is visible and will be designed, built, optimized, and tested.
Dual Polarity Ion Confinement and Mobility Separations
Structures for Lossless Ion Manipulations (SLIM) have been rapidly gaining prominence for applications where ultra-high resolution Ion Mobility (IM) separations are desired to provide performance features and information unattainable using the currently available IM platforms. Although most routine analyses are done in either positive or negative polarity modes, there are significant benefits to both, potentially making them highly complementary if performed simultaneously. In the effort to develop a robust dual polarity IM platform, we explored an evaluation of a novel SLIM platform developed to perform simultaneous cationic and anionic IM separations (i.e. without requiring polarity switching).
Measurements of {phi} meson production in relativistic heavy-ion collisions at the BNL Relativistic Heavy Ion Collider (RHIC)
We present results for the measurement of {phi} meson production via its charged kaon decay channel {phi}{yields}K{sup +}K{sup -} in Au+Au collisions at {radical}(s{sub NN})=62.4,130, and 200 GeV, and in p+p and d+Au collisions at {radical}(s{sub NN})=200 GeV from the STAR experiment at the BNL Relativistic Heavy Ion Collider (RHIC). The midrapidity (|y|<0.5) {phi} meson transverse momentum (p{sub T}) spectra in central Au+Au collisions are found to be well described by a single exponential distribution. On the other hand, the p{sub T} spectra from p+p, d+Au, and peripheral Au+Au collisions show power-law tails at intermediate and high p{sub T} and are described better by Levy distributions. The constant {phi}/K{sup -} yield ratio vs beam species, collision centrality, and colliding energy is in contradiction with expectations from models having kaon coalescence as the dominant mechanism for {phi} production at RHIC. The {omega}/{phi} yield ratio as a function of p{sub T} is consistent with a model based on the recombination of thermal s quarks up to p{sub T}{approx}4 GeV/c, but disagrees at higher transverse momenta. The measured nuclear modification factor, R{sub dAu}, for the {phi} meson increases above unity at intermediate p{sub T}, similar to that for pions and protons, while R{sub AA} is suppressed due to the energy loss effect in central Au+Au collisions. Number of constituent quark scaling of both R{sub cp} and v{sub 2} for the {phi} meson with respect to other hadrons in Au+Au collisions at {radical}(s{sub NN})=200 GeV at intermediate p{sub T} is observed. These observations support quark coalescence as being the dominant mechanism of hadronization in the intermediate p{sub T} region at RHIC.
Activation behavior for ion permeation in ion-exchange membranes: Role of ion dehydration in selective transport
Here we explored the mechanisms governing the selectivity of anion- and cation-exchange membranes for the transport of four monovalent anions (i.e., fluoride, chloride, bromide, and nitrate) and four monovalent cations (i.e., sodium, potassium, cesium, and ammonium), respectively. Our ion adsorption and transport tests with mixed ion solutions reveal that an ion with larger ionic radius and lower hydration energy is more favorably adsorbed onto the ion-exchange membrane but diffuses more slowly through the polymer matrix compared to an ion with smaller ionic radius and higher hydration energy. Individual anion (as sodium salt) or cation (as chloride salt) permeation tests at different temperatures were performed to evaluate the activation behavior of ion transport through the ion-exchange membranes by calculating the energy barrier and pre-exponential factor (i.e., the ion flux when the energy barrier is negligible) for ion transport from an Arrhenius-type equation. Our results show that an ion with smaller ionic radius and higher hydration energy experiences higher energy barrier (e.g., fluoride, 10.3 kcal mol -1 ) and possesses higher pre-exponential factor compared to an ion with larger ionic radius and lower hydration energy (e.g., bromide, 4.6 kcal mol -1 ). This correlation corroborates our main hypothesis that the activation behavior observed for ion transport is a result of ion dehydration at the water-membrane interface. Our proposed ion selectivity mechanism elucidates how ion dehydration governs the extent of ion permeation into the membrane and the subsequent transport through the charged polymer matrix. Future membrane design that promotes dehydration of target ions is challenging but can result in unprecedented ion selectivity.