Search NASA⌕ Search

SEARCH · Search NASA

Results for “IPC”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

THRESHOLD FOR EXTENDED EMISSION IN SHORT GAMMA-RAY BURSTS

The initial pulse complex (IPC) in short gamma-ray bursts is sometimes accompanied by a softer, low-intensity extended emission (EE) component. In cases where such a component is not observed, it is not clear if it is present but below the detection threshold. Using Bayesian Block (BB) methods, we measure the EE component and show that it is present in one-quarter of a Swift/BAT sample of 51 short bursts, as was found for the Compton/BATSE sample. We simulate bursts with EE to calibrate the BAT threshold for EE detection and show that this component would have been detected in nearly half of BAT short bursts if it were present, to intensities {approx}10{sup -2} counts cm{sup -2} s{sup -1}, a factor of 5 lower than actually observed in short bursts. In the BAT sample, the ratio of average EE intensity to IPC peak intensity, R{sub int}, ranges over a factor of 25, R{sub int} {approx} 3 x 10{sup -3} to 8 x 10{sup -2}. In comparison, for the average of the 39 bursts without an EE component, the 2{sigma} upper limit is R{sub int} < 8 x 10{sup -4}. These results suggest that a physical threshold effect operates near R{sub int} {approx} few x 10{sup -3} below which the EE component is not manifest.

54 ENVIRONMENTAL SCIENCES↗

HETEROGENEITY IN SHORT GAMMA-RAY BURSTS

We analyze the Swift/BAT sample of short gamma-ray bursts, using an objective Bayesian Block procedure to extract temporal descriptors of the bursts' initial pulse complexes (IPCs). The sample is comprised of 12 and 41 bursts with and without extended emission (EE) components, respectively. IPCs of non-EE bursts are dominated by single pulse structures, while EE bursts tend to have two or more pulse structures. The medians of characteristic timescales-durations, pulse structure widths, and peak intervals-for EE bursts are factors of {approx}2-3 longer than for non-EE bursts. A trend previously reported by Hakkila and colleagues unifying long and short bursts-the anti-correlation of pulse intensity and width-continues in the two short burst groups, with non-EE bursts extending to more intense, narrower pulses. In addition, we find that preceding and succeeding pulse intensities are anti-correlated with pulse interval. We also examine the short burst X-ray afterglows as observed by the Swift/X-Ray Telescope (XRT). The median flux of the initial XRT detections for EE bursts ({approx}6x10{sup -10} erg cm{sup -2} s{sup -1}) is {approx}>20x brighter than for non-EE bursts, and the median X-ray afterglow duration for EE bursts ({approx}60,000 s) is {approx}30x longer than for non-EE bursts. The tendency for EE bursts toward longer prompt-emission timescales and higher initial X-ray afterglow fluxes implies larger energy injections powering the afterglows. The longer-lasting X-ray afterglows of EE bursts may suggest that a significant fraction explode into denser environments than non-EE bursts, or that the sometimes-dominant EE component efficiently powers the afterglow. Combined, these results favor different progenitors for EE and non-EE short bursts.

79 ASTRONOMY AND ASTROPHYSICS↗

SU-F-T-104: Determining the NTCP Parameters of Pharyngeal Constrictors and Proximal Esophagus for Radiation Induced Swallowing Problems Recorded Six Months After Radiation Therapy for Head and Neck Tumors

Purpose: To estimate the radiobiological parameters of four NTCP models that describe the dose-response relations of pharyngeal constrictors and proximal esophagus regarding the severity of patient reported swallowing problems 6 months post chemo-radiotherapy. To identify the section/structure that best correlates with the manifestation of the clinical endpoints. Finally, to compare the goodness-of-fit of those models. Methods: Forty-three patients were treated on a prospective multi-institutional phase II study for oropharyngeal squamous cell carcinoma. All the patients received 60 Gy IMRT and they reported symptoms using the novel patient reported outcome version of the CTCAE. We derived the individual patient dosimetric data of superior, medium and inferior sections of pharyngeal constrictors (SPC, MPC and IPC), superior and inferior sections of esophagus (SES and IES) as separate structures as well as combinations. The Lyman-Kutcher-Burman (LKB), Relative Seriality (RS), Logit and Relative Logit (RL) NTCP models were used to fit the patient data. The fitting of the different models was assessed through the area under the receiver operating characteristic curve (AUC) and the Odds Ratio methods. Results: The AUC values were highest for the SPC for Grade ≥ 2 (0.719 for the RS and RL models, and 0.716 for LKB and Logit). For Grade ≥ 1, the respective values were 0.699 for RS, LKB and Logit and 0.676 for RL. For MPC the AUC values varied between 0.463–0.477, for IPC between 0.396–0.458, for SES between 0.556–0.613 and for IES between 0.410–0.519. The Odds Ratio for the SPC was 15.6 (1.7–146.4) for RS, LKB and Logit for NTCP of 55%. Conclusion: All the examined NTCP models could fit the clinical data with similar accuracy. The SPC appear to correlate best with the clinical endpoints of swallowing problems. A prospective study could establish the use of NTCP values of SPC as a constraint in treatment planning.

60 APPLIED LIFE SCIENCES↗

Lightfall v0.0.1

Lightfall is a desktop application for synchrotron beamline instrument control, data acquisition, and live analysis at the Advanced Light Source (ALS). Built on Python and Qt, it provides a native graphical interface for operating beamline hardware, configuring and executing experimental scans, and visualizing results in real time. Key features include direct integration with EPICS control systems, a built-in electronic logbook, remote beamline access over secure tunnels, and an interprocess communication (IPC) architecture that coordinates with external analysis applications via ZMQ and EPICS process variables. This IPC approach allows Lightfall to orchestrate specialized analysis tools—including GPU-accelerated streaming correlators—without embedding them, avoiding the dependency conflicts common in monolithic scientific software platforms. Compared to prior approaches such as Xi-CAM's plugin-based architecture, Lightfall's design cleanly separates instrument control from domain-specific analysis, enabling feedback-driven acquisition where live analysis results can adjust scan parameters during an experiment. Its native Qt interface provides responsive performance for real-time data visualization that web-based alternatives struggle to match. Lightfall is designed for use by beamline scientists and staff operating synchrotron instruments at national user facilities.

Pandolfi, Ronald [Lawrence Berkeley National Labor↗

A conceptual evaluation framework for the water and sanitation for health facility improvement tool (Wash Fit)

Healthcare facilities (HCFs) in low- and middle-income countries frequently lack water, sanitation and hygiene (WASH) services that are adequate to implement infection prevention and control (IPC) practices, decrease healthcare-associated infections and antimicrobial resistance, and provide quality healthcare. The Water and Sanitation for Health Facility Improvement Tool (WASH FIT), initially published in 2017 and updated in 2018, is a risk-based, continuous improvement framework. The tool aims to improve WASH and related facility management and may contribute to quality of care (QoC) efforts. To date, there is no guidance available on how to monitor and evaluate the use of this tool nor is there rigorous evidence on its effectiveness. We developed a conceptual WASH FIT evaluation framework by drawing from the broader WASH, health systems strengthening, and QoC evidence base. This framework provides a common basis to plan, implement, monitor, and evaluate potential inputs, outputs, outcomes, and impacts from applying WASH FIT. Routine use of the tool, coupled with WASH infrastructure improvements as guided by the tool, can lead to better IPC practices, and may support improvements in occupational safety, QoC, global health security, and ultimately progress towards achieving Sustainable Development Goals 3 (good health and well-being) and 6 (clean water and sanitation).

60 APPLIED LIFE SCIENCES↗

National Renewable Energy Laboratory Pyrheliometer Comparisons: 24 September - 5 October 2012 (NPC-2012)

The NREL Pyrheliometer Comparisons for 2012 (NPC-2012) were held at the Solar Radiation Research Laboratory in Golden, Colorado, from September 24 through October 5 for the purpose of transferring the World Radiometric Reference (WRR) to participating instrument. Twenty scientists and engineers operated 32 absolute cavity radiometers and 18 conventional thermopile-based pyrheliometers to simultaneously measure clear-sky direct normal irradiance during the comparisons. The transfer standard group of reference radiometers for NPC-2012 consisted of four NREL radiometers with direct traceability to the WRR, having participated in the Eleventh International Pyrheliometer Comparisons (IPC-XI) hosted by the World Radiation Center in the fall of 2010. As the result of NPC-2012, each participating absolute cavity radiometer was assigned a new WRR transfer factor, computed as the reference irradiance computed by the transfer standard group divided by the observed irradiance from the participating radiometer. The performance of the transfer standard group during NPC-2012 was consistent with previous comparisons, including IPC-XI. The measurement performance of the transfer standard group allowed the transfer of the WRR to each participating radiometer with an estimated uncertainty of +/- 0.33% with respect to the International System of Units.

14 SOLAR ENERGY↗

Development and Demonstration of Grid Integration System for PEVs, ESS, and RE: Cooperative Research and Development Final Report, CRADA Number CRD-13-515

NREL and Ideal Power Converters (IPC) will jointly develop and demonstrate a hybrid power converter system integrating bi-directional electric vehicle charging, photovoltaic generation, and stationary battery storage using IPC's 3-Port Hybrid Converter. The organizations will also jointly investigate synergies in tightly integrating these separate power conversion systems.

25 ENERGY STORAGE↗

NREL Pyrheliometer Comparisons: September 25-October 6, 2017 (NPC-2017)

Accurate measurements of direct normal (beam) solar irradiance from pyrheliometers are important for developing and deploying solar energy conversion systems, improving our understanding of the Earth's energy budget for climate change studies, and for other science and technology applications involving solar flux. Providing these measurements places many demands on the quality system used by the operator of commercially available radiometers. Maintaining accurate radiometer calibrations that are traceable to an international standard is the first step in producing research-quality solar irradiance measurements. In 1977, the World Meteorological Organization (WMO) established the World Radiometric Reference (WRR) as the international standard for the measurement of direct normal solar irradiance (Frohlich 1991). The WRR is an internationally recognized, detector-based measurement standard determined by the collective performance of six electrically self-calibrated absolute cavity radiometers comprising the World Standard Group (WSG). Various countries, including the United States, have contributed these specialized radiometers to the Physikalisch-Meteorologisches Observatorium Davos - World Radiation Center (PMOD/WRC) to establish the WSG. As with all measurement systems, Absolute Cavity Radiometers (ASR) are subject to performance changes over time. Therefore, every five years the PMOD/WRC in Davos, Switzerland, hosts an International Pyrheliometer Comparison (IPC) for transferring the WRR to participating radiometers. NREL has represented the U.S. Department of Energy (DOE) in each IPC since 1980. As a result, NREL has developed and maintained a select group of absolute cavity radiometers with direct calibration traceability to the WRR, and uses these reference instruments to calibrate pyrheliometers and pyranometers using the International Organization for Standardization (ISO) 17025 accredited Broadband Outdoor Radiometer Calibration (BORCAL) process (Reda et al. 2008). National Renewable Energy Laboratory (NREL) pyrheliometer comparisons (NPCs) are held annually at the Solar Radiation Research Laboratory (SRRL) in Golden, Colorado. Open to all ACR owners and operators, each NPC provides an opportunity to determine the unique WRR transfer factor (WRR-TF) for each participating pyrheliometer. By adjusting all subsequent pyrheliometer measurements by the appropriate WRR-TF, the solar irradiance data are traceable to the WRR.

14 SOLAR ENERGY↗

Distributed Generation Cost-Benefit and Ratemaking Considerations for Idaho

This memo was completed through the Grid Modernization Laboratory Consortium (GMLC), a strategic partnership between the U.S. Department of Energy (DOE) and the national laboratories to bring together leading experts, technologies, and resources to collaborate on the goal of modernizing the nation’s grid. The GMLC was established as part of the DOE Grid Modernization Initiative to accelerate the development of technology, modeling analysis, tools, and frameworks to help enable grid modernization. Special thanks to DOE project leads, Larry Mansueti and Elaine Ulrich, and the laboratory project lead for this effort, Peter Cappers from Lawrence Berkeley National Laboratory (LBNL). The Idaho Public Utility Commission (IPUC) Staff requested this technical assistance to improve their understanding of the emerging, complex, and consequential issues around distributed energy resource (DER) rate design to help the staff achieve its goal of making a fair, just, and reasonable rate design recommendation with respect to Order 34147 under Case No. IPC-E-17-13. 2 PNNL-28285 In Case No. IPC-E-17-13, Idaho Power requested authorization from the IPUC to establish new rate schedules for residential and small general service customers with on-site generation. The IPUC’s Order No. 34046 of May 9, 2018 authorized Idaho Power to (IPUC 2018a): Close Schedule 84 and create Schedule 6 for residential on-site generators and Schedule 8 for small general service on-site generators; Acknowledge smart inverter technology; Make proposed revisions to interconnection Schedule 72; Open an Idaho Power-specific docket to “to comprehensively study the costs and benefits of on-site generation on Idaho Power’s system, as well as proper rates and rate design, transitional rates, and related issues of compensation for net excess energy provided as a resource” to Idaho Power; File a study with the IPUC “exploring fixed-cost recovery in basic charges and other rate design options prior to its next general rate case.”

24 POWER TRANSMISSION AND DISTRIBUTION↗

Gamma & Neutron Field-Data Recommendations [Slides]

Summary: The three spectra types desired are: IPC, background, known source; Source-to-detector distance should be stated clearly and photographed if possible; 300 sec is the minimum desired count time; A background spectrum provides a baseline against which to compare the IPC spectrum; Photographs and an event / scenario description can provide situational awareness

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

BioID/LID System Cartridge Testing Report

LLNL produced two lots of lyophilized LAMP assay containing cartridges, LNL022818 and LNL071818, for testing on Gen3 BioID systems. Thirty-nine cartridges were tested for lot LNL022818. All thirty-nine cartridges performed as expected regarding correct positive control (IPC) and negative control (NTC) reactions. Five different templates were tested on these 39 cartridges. The BioID system detected 79.1% true positives and 9.3% false positives along with 98.9% true negatives and 2.9% false negatives for cartridge lot LNL022818. Thirty cartridges were tested for lot LNL071818. It was noted early that due to a manufacturing issue with the cartridges related to incomplete sonic welding of the cartridge, a large fraction of lot LNL071818 cartridges leaked. Insufficient funds were available to replace this lot of cartridges. Twenty three of 30 cartridges performed as expected regarding correct positive control (IPC) and negative control (NTC) reactions. Four different templates were tested on these 30 cartridges. The BioID system detected 77% true positives and 23% false positives along with 96.9% true negatives and 3.1% false negatives for cartridge lot LNL071818. For all tested cartridges using DNA template, DNA was added at a final concentration of 25 pg/ul. All reactions contained positive control DNA at 2.5 pg/ul.

42 ENGINEERING↗

Implementation of a pressure correction term in the CTF sub-channel code

CTF [1] is a modernized and improved version of the legacy subchannel code, COBRA-TF [2], that is being jointly developed and maintained by Oak Ridge National Laboratory (ORNL) and North Carolina State University. The code was adopted by ORNL for use in the Consortium for Advanced Simulation of Light Water Reactors (CASL) in 2012 for aiding in addressing CASL challenge problems. Since that time, activities related to CTF have included implementing software quality assurance measures, implementing new features and models, performing validation and verification testing, establishing and supporting a CTF User Group, and developing the code for use in coupled applications [3, 4, 5]. CTF is applicable to single- and two-phase flows in light water reactor geometries at normal and accident operating conditions. The two-phase flow model consists of the six-equation two-phase flow model [6] augmented by equations for the droplet field and also includes appropriate source terms. This work focuses on the numerical stability of the six-equation two-phase flow model and is part of a recent eort to improve CTF capabilities for simulating flows in boiling nuclear reactors (BWRs). As it is of common knowledge among the thermodynamic community, the six-equation two-phase flow model is not strongly hyperbolic, meaning some of its eigenvalues are either not real or not distinct [7]. In a Cauchy sense and for an initial-value problem, strong hyperbolicity was found to be equivalent to well-posedness which ensures uniqueness of the solution in the space-time used. This concept is also of importance when designing high-order numerical methods and also when implementing boundary conditions that rely on real eigenvalues such as Riemann solvers. A tremendous amount of research is available in the literature on how to hyperbolize the six-equation two-phase flow model by adding ad hoc terms to the system of equations often referred to as virtual mass or interfacial pressure correction term. From a mathematical prospective, the main idea driving this approach is to add terms to the phasic momentum equation containing first-order partial derivatives of the unknowns to modify the Jacobian matrix and thus canceling the imaginary part of the eigenvalues.For this work it was chosen to implement a interfacial pressure correction (IPC) term on the same model as what was done for the CATHARE system code [8], that allows to recover a two-pressure formulation. In the following, the six-equation two-phase flow model is recalled along with the IPC term and its influence on the eigenvalues. Then, numerical results and convergence studies are presented for a water-faucet problem [9] at a pressure of 10 bar. Finally, conclusions and future work are addressed.

Delchini, Marco↗

Implementation of a Pressure Correction Term in the CTF Subchannel Code

CTF is a modernized and improved version of the legacy subchannel code COBRA-TF, being jointly developed and maintained by Oak Ridge National Laboratory (ORNL) and North Carolina State University. The code was adopted by ORNL for use in the Consortium for Advanced Simulation of Light Water Reactors (CASL) in 2012 to help address CASL challenge problems. Since that time, activities related to CTF have included implementing software quality assurance measures, implementing new features and models, performing validation and verification testing, establishing and supporting a CTF user group, and developing the code for use in coupled applications. CTF is applicable to single- and two-phase flows in light water reactor geometries at normal and accident operating conditions. The two-phase flow model consists of the six-equation two-phase flow model augmented by equations for the droplet field, and it also includes appropriate source terms. This work focuses on the numerical stability of the six-equation two-phase flow model and is part of a recent effort to improve CTF capabilities for simulating flows in boiling water reactors (BWRs). The six-equation two-phase flow model is not strongly hyperbolic, meaning that some of its eigenvalues are either not real or not distinct. In a Cauchy sense, and for an initial-value problem, strong hyperbolicity was found to be equivalent to well-posedness, which ensures the uniqueness of the solution in the space-time used. This concept is also of importance when designing high-order numerical methods and also when implementing boundary conditions that rely on real eigenvalues such as Riemann solvers. A tremendous amount of research is available in the literature on how to hyperbolize the six-equation two-phase flow model by adding ad hoc terms to the system of equations. Such terms are often referred to as virtual mass or interfacial pressure correction terms. From a mathematical perspective, this approach adds terms to the phasic momentum equation containing first-order partial derivatives of the unknowns to modify the Jacobian matrix, thus the imaginary part of the eigenvalues. For this work, an interfacial pressure correction (IPC) term on the same model as what was used for the CATHARE system code, is implemented in CTF. This allows for recovery of a two-pressure formulation. In the following, the six-equation two-phase flow model is recalled, along with the IPC term and its influence on the eigenvalues. Then, numerical results and convergence studies are presented for a water-faucet problem at a pressure of 10 bar. Finally, conclusions and future work are addressed.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Infrastructure-Based Cooperative Perception at a Traffic Intersection: Overview and Challenges: Preprint

Recent advancement in autonomous driving vehicles and V2X communication has attracted increasing attention towards Intelligent Transportation Systems to build a safe and reliable traffic intersection. However, most of the systems are still at the initial stages and require significant progress to become a reality. This paper presents an overview of NREL Infrastructure Perception and Control (IPC) framework which is an open-source track-data fusion engine which takes input from infrastructure-based perception sensors and cooperatively shared messages from Connected Autonomous Vehicles (CAVs) and Connected Vehicle (CVs) and the challenges associated with deploying such cooperative perception framework at a four-way traffic intersection in the city of Colorado Springs, CO, USA. The sensor data is collected by deploying two radars and two LiDAR sensors on the IPC mobile lab and two radars on diagonally opposite traffic poles at the proposed intersection. The sensor output results imply the need for rapid sensor calibration to bring the collective perception to a common coordinate frame, the importance of time synchronization between the sensors in order to capture accurate spatial and temporal alignment of the objects, and the need for a health monitoring system with fail safe closed-loop detection model for real-time deployment.

camera↗

A Boomerang-Shaped Reduction in Interlayer Phase Coherence in Bi 2 Sr 2 CaCu 2 0 8+y with Splayed Columnar Defects

We present evidence for entangled solid vortex matter in a glassy state in a layered superconductor Bi{sub 2}Sr{sub 2}CaCu{sub 2}O{sub 8+y} containing randomly splayed linear defects. The interlayer phase coherence(IPC) - probed by the Josephson plasma resonance - is enhanced at high temperatures, reflecting the recoupling of vortex liquid by the defects. At low temperatures in the vortex solid state, the interlayer coherence follows a boomerang-shaped reentrant temperature path with an unusual low field decrease in coherence, indicative of meandering vortices. This behavior suggests strongly suppressed IPC in this system, which may be explained by the vortex entanglement induced by the columnar defects in the 'splayed-glass' state.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Infrastructure Perception and Control Laboratory [ITS Research Lab]

U.S. Department of Energy national laboratories host world-class advanced computing and modeling capabilities. The National Renewable Energy Labowratory (NREL) inaugurated the Infrastructure Perception and Control Laboratory (IPC Lab) to advance mobility reach into real-world applications.

99 GENERAL AND MISCELLANEOUS↗

NREL Infrastructure Perception and Control Workshop

A lack of highly reliable, full state-space awareness of roadway situations is the current bottleneck for the incremental introduction of smart infrastructure control. NREL's Infrastructure Perception and Control (IPC) lab applies advanced sensing and computation controls to the coordinated movement of vehicles on the road as well as people in large facilities and has produced field test results from a Colorado Springs intersection. In this presentation, NREL discusses the state of smart infrastructure control and opportunities for partnership.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Process Control Plan to Monitor Acceptable Levels of Flux and other residues

IPC J-STD –001G, Amendment 1 requires that the assembler have a sampling plan to assure that the process remains in control once qualified and validated. It is well documented that electrochemical failures occur at component sites where flux residues are not fully activated. It is also well known that specific components have a higher risk of electrochemical failure. Selecting a control plan that monitors the process and its performance on challenging components provides assurance that the process maintains control once established during process qualification. The test board used to qualify the process establishes an upper and lower spec limit for each of the component types on the test board. Surface Insulation Resistance upper and lower control limits, using challenging components that are representative of production hardware, represent a golden process condition. The golden image is a measure of process deviations that represents the performance of a resistance curve within a specific period. The objective is to judge whether the process in or out of control.

42 ENGINEERING↗