Search NASA⌕ Search

SEARCH · Search NASA

Results for “Impacts of Model Building Energy Codes”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

60 records · Page 4

Simulations of Laser Experiments to Study the Origin of Cosmic Magnetic Fields

Magnetic fields are ubiquitous in the universe; however, their origin is not fully understood. Cosmologists and astrophysicists have proposed a variety of ways in which small seed magnetic fields could be created. It is widely thought that the much larger values of the cosmic magnetic fields that we observe are a result of the amplification of these seed fields by the nonlinear turbulent dynamo mechanism. Such a mechanism had not yet been demonstrated in a controlled laboratory environment. We conceived experiments designed to demonstrate and study the nonlinear turbulent dynamo mechanism in the laboratory. These experiments characterize the distribution of turbulent energy among the velocity, magnetic field, and density fluctuations, providing a comprehensive picture of the energy cascade in a magnetized, turbulent plasma. The experiments build on the pathfinder experiments we have conducted on the Vulcan laser at the Rutherford-Appleton Laboratory in the UK and the OMEGA laser at Laboratory for Laser Energetics at Rochester. They utilize the high-intensity lasers at the Omega Laser Facility, the National Ignition Facility (NIF) at LLNL and the Laser Megajoule (LMJ) Facility in France – the largest laser facilities in the world. The goal of this project was to design and model the highly demanding experiments through simulation campaigns using FLASH, a highly capable radiation-MHD code we have developed, and large-scale 3D simulations on the Mira supercomputer at ANL. The simulations were vital to ensuring the experiments achieve the strong turbulence and large magnetic Reynolds numbers required for the nonlinear turbulent dynamo mechanism to operate. The simulations were also critical to determining when to fire the diagnostics, since the experiments last tens of nanoseconds but the signals of the strongly amplified magnetic fields last only a few nanoseconds. Finally, high-fidelity, validated FLASH simulations were crucial to interpreting the results of the experiments. By combining theory, experiments, and simulations, we were able to succeed in demonstrating and characterizing the nonlinear turbulent dynamo mechanism. The effort leveraged (1) the emergence of the Flash Center for Computational Science as a leader in numerical modeling of academic High Energy Density Physics (HEDP) experiments; (2) the FLASH code, which has been developed by the Flash Center and is a leadership-class, multi- physics, publicly available community code that has been applied successfully in many laser-driven experiments; (3) the expertise acquired through pathfinder experiments we performed on the Vulcan laser at the Rutherford-Appleton Laboratory in the UK and on the Omega laser facility; (4) the experience we have gained in designing and interpreting these experiments using validated simulations done with FLASH; and (5) the close collaborations we have established with outstanding experimental groups in the US and abroad. The broader impacts of the project are two-fold: (1) the work furthered the transformation of the academic community’s ability to design and analyze HEDP experiments at large laser facilities that is happening through the availability of FLASH and its widespread adoption by the academic community – a community that previously had had limited access to open and validated hydro/MHD simulation tools for HEDP experiments; and (2) the work trained young scientists to design and interpret HEDP experiments using validated simulations – a critical national need.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

MATBOX, an Open-Source Microstructure Analysis Toolbox for Meshing, Generation, Segmentation, and Characterization of 3D Heterogenous Volumes

Battery performance is strongly correlated with electrode microstructural properties. To account for its impact, lithium-ion battery (LIB) models either abstract the microstructural heterogeneity of composite electrodes using effective macroscopic properties (macro- or meso- scale models) or directly solve the system of equations on the microstructure geometry or mesh (microstructure-scale models). Therefore, to be adequate, both families of models require information from the microstructure geometry, which can be provided by the numerical tool presented in this work. MATBOX is a MATLAB open-source application [1] developed by NREL for performing various microstructure-related tasks including microstructure numerical generation, image filtering and microstructure segmentation, microstructure characterization and correlation, visualization, and microstructure meshing. MATBOX was originally developed for the analysis of LIB electrode microstructures; however, the algorithms provided by the toolbox are widely applicable to other heterogeneous materials. The toolbox provides a user-friendly experience thanks to a Graphical-User Interface, requires no coding by the user, and is well documented. This presentation will illustrate various MATBOX features for the characterization of a LIB electrode, including a fully automated Representative Volume Element (RVE) analysis, the numerical generation of complex 'virtual' microstructure, including dual-layer electrodes and carbon-binder additive phase, and the meshing of a complex NMC/graphite full cell microstructure suitable for 3D finite-element modeling. Other modules (segmentation, visualization, and correlation) will be briefly presented. Thanks to its modular, open-source approach, MATBOX can easily incorporate third-party algorithms to eventually build a standard in the field that will benefit the whole scientific community. Effective diffusion coefficient [2], additive phase numerical generation [3], and meshing [4] third-party algorithms have been already integrated in the toolbox with more to come.

DIRECT ENERGY CONVERSION,MATHEMATICS AND COMPUTING↗

Understanding detachment of the W7-X island divertor

The fundamental behavior of the W7-X island divertor under detached conditions, which has been theoretically predicted with the EMC3-Eirene code, is re-examined here under the experimental conditions achieved so far and compared with the first experimental results. Both simulations and experiments cover a range of divertor configurations and plasma parameters, and show the following common trends: (1) with rising impurity radiation, the target heat load decreases 'uniformly' over the entire target surface in the sense that both the peak and average heat loads can drop by an order of magnitude. Impurity radiation (mainly from intrinsic carbon) occurs primarily at the plasma edge and the resulting negative impact on the stored energy is less than 10%. (2) When the total radiation exceeds a critical level, the target particle flux (the recycling flux Γrecy) begins to fall and can drop by a factor of 3–5 at high radiation levels without an obvious indication of significant volume recombination. (3) While Γ recy decreases, the divertor neutral pressure continues to build up and reaches a maximum, at which point Γ recy has declined significantly. (4) During detachment, the electron temperature at the last closed flux surface falls in a way that is not quantitatively understandable from parallel classical heat conduction processes. This paper presents a physical explanation of the numerical/experimental results described above. Furthermore, using the EMC3-Eirene code as a diagnostic tool, we are able, apparently for the first time, to provide a full quantitative analysis of each transport channel in the island divertor, aiming to clarify how the island divertor plasma self-regulates to maintain particle, energy, and momentum balance under detached conditions.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

InSight's Reconstructed Aerothermal Environments

The InSight Mars Lander successfully landed on the surface on November 26, 2018. This poster will describe the methodologies and margins used in developing the aerothermal environments for design of the thermal protection systems (TPS), as well as a prediction of as-flown environments based on the best estimated trajectory. The InSight mission spacecraft design approach included the effects of radiant heat flux to the aft body from the wake for the first time on a US Mars Mission, due to overwhelming evidence in ground testing for the European ExoMars mission (2009/2010) [1] and 2010 tests in the Electric Arc Shock Tube (EAST) facility [2]. The radiant energy on an aftbody was also recently confirmed via measurement on the Schiaparelli mission [3]. In addition, the InSight mission expected to enter the Mars atmosphere during the dust storm season, so the heatshield TPS was designed to accommodate the extra recession due to the potential dust impact. This poster will compare the predicted aerothermal environments using the reconstructed best estimated trajectory to the design environments. Design Approach: The InSight spacecraft was planned to be a near-design-to-print copy of the Phoenix spacecraft. The determination of the heatshield TPS requirements was approached as if it was a new design due to the new requirement of flying through a dust storm. The baseline for aftbody was build-to-print, and all analyses focused on ensuring adequate margin. This proved to be a challenge because the Phoenix aftbody was designed to withstand only convective heating and the InSight aftbody was evaluated for both convective and radiative heating. Aerothermal environments were predicted using the Langley Aerothermodynamic Upwind Relaxation Algorithm (LAURA) and the Data Parallel Line Relaxation (DPLR) CFD codes, and the Nonequilibrium Radiative Transport and Spectra Program (NEQAIR) utilizing bounding design trajectories derived from Monte Carlo analyses from the Program to Optimize Simulated Trajectories II (POST2). In all cases, super-catalytic flowfields were assigned to ensure the most conservative heating results. Two trajectories were evaluated: 1) the trajectory with the maximum heat flux was utilized to determine the flowfield characteristics and the viability of the selection of TPS materials; and 2) the trajectory with the maximum heat load was used to determine the required thicknesses of the TPS materials. Evaluation of the MEDLI data [4], along with ground test data [5] led to the determination of whether or not the flow would transition from laminar to turbulent on the heatshield, which also determined the TPS sizing location for the heatshield. Aerothermal margins were added for the convective heating and developed for the radiative heating. TPS material sizing was determined with the Reaction Kinetic Ablation Program (REKAP) and the Fully Implicit Ablation and Thermal Analysis program (FIAT) using a three-branched approach to account for aerothermal, material response, and material properties uncertainties. In addition, the heatshield recession was augmented by an analysis of the effect of entry through a potential dusty atmosphere using a methodology developed in References [6] and [7]. These analyses resulted in an increase to the Phoenix heatshield TPS thickness. Reconstruction Efforts: Once the best estimated trajectory is reconstructed by the team, the LAURA/HARA (High-Temperature Aerothermo-dynamic Radiation model) and DPLR/NEQAIR code pairs will be used to predict the as-flown aerothermal conditions. In these runs, fully-catalytic flowfields will be assigned because it is a more physically accurate description of the chemistry in the flow. Once again, determination of the onset of turbulence on the heatshield will be evaluated. The as-flown aerothermal environments will then be compared to the design environments.

Beck, R. A.↗

Residential Building Energy Efficiency Field Studies: Low-Rise Multifamily

In recent years, the U.S. Department of Energy (DOE) has conducted a series of research studies to validate energy efficient building technologies in the field. Much of the work has focused on single-family construction, and some has also addressed commercial energy codes. The work detailed in this DOE-funded study (EE0007616) focuses on low-rise multifamily buildings (three stories or fewer above grade) in various regions of the United States, and reports on how state-level building codes are being implemented, both in terms of observed characteristics and also in terms of estimated energy impacts. Nearly 100 buildings across four states—Illinois, Minnesota, Oregon, and Washington—were sampled, which represent a range of climate types from mild temperature to very cold continental. Both common entry and outdoor entry buildings were included, and a parallel research project evaluated envelope air tightness and current still-evolving air tightness testing methods. Finally, a set of structured interviews of building designers and other relevant professionals was carried to out to gain more insight into this market. To the greatest extent possible, the methodology developed under the project for low-rise multifamily buildings mirrored the approach established by Pacific Northwest National Laboratory (PNNL) for single-family residential buildings (https://www.energy.gov/eere/buildings/downloads/residential-building-energy-code-field-study). This included the general approach to sampling, recruitment, and data collection, as well as data analysis and presentation. The range of permitting dates for the sites encompassed two energy code cycles in most regions. All states in the study had adopted a variation of the International Energy Conservation Code (IECC) for the structure of their state code. The low-rise multifamily occupancy presents a hybrid building type: most of the building’s conditioned floor area was covered by the residential chapter of the code while portions of the building (such as corridors and common spaces) fell under the commercial code chapter. The key items assessed in this work were: Building Shell—exterior wall insulation, ceiling insulation, foundation insulation, windows. Common Areas—HVAC and lighting. Living Units—lighting, ventilation. A few items were not assessed in detail, given their relative paucity in this occupancy type; these included duct leakage, pipe insulation, and hot water circulation controls. Building characteristics were collected via a combination of architectural, mechanical, electrical, and plumbing plan reviews and field inspections, and entered into a spreadsheet-based tool that was later queried to build a database. Data went through quality control both upon arrival and via a later semi-automated review and assurance process. Most of the data are presented graphically so that the reader can quickly assess compliance with the applicable energy codes (both by state and by code year). As a final step, EnergyPlus™ simulations were created for all buildings in the study to estimate both the as-found energy use intensity (EUI) and the energy and CO 2 that could be saved if features that were found to not meet code minimums were brought up to code. The savings estimates were tabulated for each of the four states in the study. The research team found that the single-family approach was largely applicable to low-rise multifamily buildings. This applies to both the data collection and the prototype EUI analysis. Most of the occupied space is living units and falls under residential energy codes, and many characteristics use similar envelope construction and relatively straightforward mechanical systems and lighting. One of the most challenging aspects of this work was to build an effective spreadsheet-based data collection instrument that could allow efficient collection of both building plan and field data. The research team is of the view that other methods could be equally effective if the work is done carefully with diligent quality control. The primary findings for the work center around the thermal envelope and mechanical systems and lighting at the sites: For thermal envelope components, the majority of buildings met or were better than the prescriptive code.This suggests that building designers and builders are aware of code requirements. In some cases, surveyed buildings were designed to qualify for energy efficiency certification programs. These buildings made up at least 20% of sampled buildings in each state. Almost all buildings met mechanical system efficiency requirements (for both living units and common areas). In some cases, sites employed systems that were considerably more efficient than required by the applicable energy code. Dwelling units had a majority of high-efficacy lighting, often in excess of the state’s residential code requirements. While high-efficacy fixtures were also typical in common areas (corridors and stairwells), lighting power densities (LPDs) in these areas were sometimes higher than levels dictated by the applicable part of the state commercial energy code. The simulation models run on a series of low-rise multifamily prototypes, informed by a composite of the field data collected, calculated annual EUIs of between 20 and 50 kBtu/ft2-yr, with the range representing the effects of both building characteristics and building location (climate zone). A detailed process (based on simulations of prototype buildings) was used to estimate the amount of avoided energy use that would occur if 100% adherence to energy codes were attained. The results indicated modest savings are attainable for items such as window thermal performance and common area lighting. The result is overall only a modest potential for additional energy savings, averaging about 10% of EUI.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Constraining the phase shift of relativistic species in DESI BAOs

In the early Universe, neutrinos decouple quickly from the primordial plasma and propagate without further interactions. The impact of free-streaming neutrinos is to create a temporal shift in the gravitational potential that impacts the acoustic waves known as baryon acoustic oscillations (BAOs), resulting in a non-linear spatial shift in the Fourier-space BAO signal. In this work, we make use of and extend upon an existing methodology to measure the phase shift amplitude $\beta _{\phi }$ and apply it to the Dark Energy Spectroscopic Instrument (DESI) Data Release 1 (DR1) BAOs with an anisotropic BAO fitting pipeline. We validate the fitting methodology by testing the pipeline with two publicly available fitting codes applied to highly precise cubic box simulations and realistic simulations representative of the DESI DR1 data. We find further study towards the methods used in fitting the BAO signal will be necessary to ensure accurate constraints on $\beta _{\phi }$ in future DESI data releases. Using DESI DR1, we present individual measurements of the anisotropic BAO distortion parameters and the $\beta _{\phi }$ for the different tracers, and additionally a combined fit to $\beta _{\phi }$ resulting in $\beta _{\phi } = 2.7 \pm 1.7$. After including a prior on the distortion parameters from constraints using Planck we find $\beta _{\phi } = 2.7^{+0.60}_{-0.67}$ suggesting $\beta _{\phi } > 0$ at 4.3$\sigma$ significance. This result may hint at a phase shift that is not purely sourced from the standard model expectation for $N_{\rm {eff}}$ or could be a upwards statistical fluctuation in the measured $\beta _{\phi }$; this result relaxes in models with additional freedom beyond Lambda-cold dark matter.

79 ASTRONOMY AND ASTROPHYSICS↗