Search NASA⌕ Search

SEARCH · Search NASA

Results for “Implementation Plan”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Data Transferability and Collection Consistency in Marine Renewable Energy

Concerns about the potential effects of tidal turbines and wave energy devices on the marine environment continue to slow siting and permitting/consenting of single devices and arrays worldwide. While research studies and early results from post-installation monitoring over the past decade have informed interactions between marine renewable energy (MRE) devices, marine animals, and habitats, regulators still demonstrate considerable reluctance to accelerate the permitting/consenting process for devices and arrays. Furthermore, the MRE industry is struggling with the high costs of baseline assessments and post-installation monitoring, as well as long timelines for obtaining permits, which leads to uncertainty and risk related to project financing. Regulators require assessment and monitoring information to allow them to carry out the necessary analyses to describe, permit/consent, and manage the environmental risks associated with new MRE technologies and new uses of ocean space. One way to reduce risks to the industry and the environment and to allow for acceleration of the permitting/consenting process could be to transfer learning, analyses, and data sets from one country to another, among projects, and across jurisdictional boundaries. In addition, data are collected around early-stage MRE devices using many different methods, instruments, and measurement scales. If similar parameters and accessible methods of data collection were used for baseline assessments and post-installation monitoring around all early-stage devices and MRE developments, the results would be more readily comparable. This comparability would lead to a decrease in scientific uncertainty and support a common understanding of the risk of MRE devices to the marine environment. This in turn would facilitate more efficient and shorter permitting/consenting processes, which would decrease the financial risk for MRE project development. As a means of addressing the concept of transferring data (information, learning, analyses, and data sets) among projects and collecting data consistently, Annex IV has developed a data transferability process that has been socialized with the MRE community, which includes regulators, industry, developers, consultants, and researchers. The data transferability process consists of five components: 1. A Data Transferability Framework brings together data sets in an organized fashion, compares the applicability of each data set for use on other projects, and guides the process of data transfer 2. A Data Collection Consistency Table provides preferred measurement methods or processes, reporting units, and the most common methods of analysis or interpretation and use of data 3. A Monitoring Data Sets Discoverability Matrix allows a practitioner to discover data sets based on the approach presented in the Framework 4. Best Management Practices (BMPs) include five BMPs related to data transferability and collection consistency 5. An Implementation Plan presents an approach for implementing and applying the data transferability process. This report documents the background and development of the data transferability process and associated components and summarizes the next steps needed to successfully implement and apply the data transferability process.

16 TIDAL AND WAVE POWER↗

NNSA Public Affairs Program Plan

The plan is based on various implementation plans and strategies that define ongoing activities. If significant updates, such as changes or additions to goals and messaging occur, Sandia will submit an updated plan to the Contracting Officer for approval.

99 GENERAL AND MISCELLANEOUS↗

A Tool for Planning Near-Term Waste Transfers at the Hanford Site - 18491

Washington River Protection Solutions, LLC is developing a software tool designed to simulate near-term waste affecting activities at the Hanford Site. The tool will allow for timely planning and evaluation of near-term operational activities, as well as facilitate feedback incorporation from the field to enable rapid iteration of various planning scenarios for a Multi-Year Operating Plan. Implementation of this tool in the Multi-Year Operating Plan planning process will support building a better connection between execution of daily activities and long-term mission objectives. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

INL Human Performance Improvement Guide, GDE-863

Guidance on Integrating Human Performance Improvement including guidance on Developing Area Specific Implementation Plans, Tool Usage, and Building the Capacity for Resiliency aka Failing Safely.

99 GENERAL AND MISCELLANEOUS↗

Status of SFR Codes and Methods QA Implementation

This report details development of the SAS4A/SASSYS-1 SQA Program and describes the initial stages of Program implementation planning. The provisional Program structure, which is largely focused on the establishment of compliant SQA documentation, is outlined in detail, and Program compliance with the appropriate SQA requirements is highlighted. Additional program activities, such as improvements to testing methods and Program surveillance, are also described in this report. Given that the programmatic resources currently granted to development of the SAS4A/SASSYS-1 SQA Program framework are not sufficient to adequately address all SQA requirements (e.g. NQA-1, NUREG/BR-0167, etc.), this report also provides an overview of the gaps that remain the SQA program, and highlights recommendations on a path forward to resolution of these issues. One key finding of this effort is the identification of the need for an SQA program sustainable over multiple years within DOE annual R&D funding constraints.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

SU-F-T-504: Non-Divergent Planning Method for Craniospinal Irradiation

Purpose: Traditional Craniospinal Irradiation (CSI) planning techniques require careful field placement to allow optimal divergence and field overlap at depth, and measurement of skin gap. The result of this is a necessary field overlap resulting in dose heterogeneity in the spinal canal. A novel, nondivergent field matching method has been developed to allow simple treatment planning and delivery without the need to measure skin gap. Methods: The CSI patient was simulated in the prone, and a plan was developed. Bilateral cranial fields were designed with couch and collimator rotation to eliminate divergence with the upper spine field and minimize anterior divergence into the lenses. Spinal posterior-to-anterior fields were designed with the couch rotated to 90 degrees to allow gantry rotation to eliminate divergence at the match line, and the collimator rotated to 90 degrees to allow appropriate field blocking with the MLCs. A match line for the two spinal fields was placed and the gantry rotated to equal angles in opposite directions about the match line. Jaw positions were then defined to allow 1mm overlap at the match line to avoid cold spots. A traditional CSI plan was generated using diverging spinal fields, and a comparison between the two techniques was generated. Results: The non-divergent treatment plan was able to deliver a highly uniform dose to the spinal cord with a cold spot of only 95% and maximum point dose of 115.8%, as compared to traditional plan cold spots of 87% and hot spots of 132% of the prescription dose. Conclusion: A non-divergent method for planning CSI patients has been developed and clinically implemented. Planning requires some geometric manipulation in order to achieve an adequate dose distribution, however, it can help to manage cold spots and simplify the shifts needed between spinal fields.

60 APPLIED LIFE SCIENCES↗

2014 Fermilab Laboratory Directoed Research \& Development Annual Report

After initiation by the Fermilab Laboratory Director, a team from the senior Laboratory leadership and a Laboratory Directed Research and Development (LDRD) Advisory Committee developed an implementation plan for LDRD at Fermilab for the first time. This implementation was captured in the approved Fermilab 2014 LDRD Program Plan and followed directions and guidance from the Department of Energy (DOE) order, DOE O 413.2B, a “Roles, Responsibilities, and Guidelines, …” document, and examples of best practices at other DOE Office of Science Laboratories. At Fermilab, a FY14 midyear Call for Proposals was issued. A LDRD Selection Committee evaluated those proposals that were received and provided a recommendation to the Laboratory Director who approved seven LDRD projects. This Annual Report focuses on the status of those seven projects and provides an overview of the current status of LDRD at Fermilab. The seven FY14 LDRD approved projects had a date of initiation late in FY14 such that this report reflects approximately six months of effort approximately through January 2015. The progress of these seven projects, the subsequent award of six additional new projects beginning in FY15, and preparations for the issuance of the FY16 Call for Proposals indicates that LDRD is now integrated into the overall annual program at Fermilab. All indications are that LDRD is improving the scientific and technical vitality of the Laboratory and providing new, novel, or cutting edge projects carried out at the forefront of science and technology and aligned with the mission and strategic visions of Fermilab and the Department of Energy.

99 GENERAL AND MISCELLANEOUS↗

Phased plan for the implementation of the time-resolving magnetic recoil spectrometer on the National Ignition Facility (NIF)

The time-resolving magnetic recoil spectrometer (MRSt) is a transformative diagnostic that will be used to measure the time-resolved neutron spectrum from an inertial confinement fusion implosion at the National Ignition Facility (NIF). It uses a CD foil on the outside of the hohlraum to convert fusion neutrons to recoil deuterons. An ion-optical system positioned outside the NIF target chamber energy-disperses and focuses forward-scattered deuterons. A pulse-dilation drift tube (PDDT) subsequently dilates, un-skews, and detects the signal. While the foil and ion-optical system have been designed, the PDDT requires more development before it can be implemented. Therefore, a phased plan is presented that first uses the foil and ion-optical systems with detectors that can be implemented immediately—namely CR-39 and hDISC streak cameras. These detectors will allow the MRSt to be commissioned in an intermediate stage and begin collecting data on a reduced timescale, while the PDDT is developed in parallel. A CR-39 detector will be used in phase 1 for the measurement of the time-integrated neutron spectra with excellent energy-resolution, necessary for the energy calibration of the system. Streak cameras will be used in phase 2 for measurement of the time-resolved spectrum with limited spectral coverage, which is sufficient to diagnose the time-resolved ion temperature. Simulations are presented that predict the performance of the streak camera detector, indicating that it will achieve excellent burn history measurements at current yields, and good time-resolved ion-temperature measurements at yields above 3 × 10 17 . The PDDT will be used for optimal efficiency and resolution in phase 3.

47 OTHER INSTRUMENTATION↗

An Asset-Based Approach to Tribal Community Energy Planning

Community energy planning is a vital component of successful energy resource development and project implementation. Planning can help tribes develop a shared vision and strategies to accomplish their energy goals. This paper explores the benefits of an asset-based approach to tribal community energy planning. While a framework for community energy planning and federal funding already exists, some areas of difficulty in the planning cycle have been identified. This paper focuses on developing a planning framework that offsets those challenges. The asset-based framework described here takes inventory of a tribe’s capital assets, such as: land capital, human capital, financial capital, and political capital. Such an analysis evaluates how being rich in a specific type of capital can offer a tribe unique advantages in implementing their energy vision. Finally, a tribal case study demonstrates the practical application of an asset-based framework.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

SUSTAINING NUCLEAR SECURITY REGIMES THROUGH CONTINUOUS LEARNING EXPERIENCES

As Member States plan, implement, and ultimately sustain their nuclear security regimes, human resource development supporting these regimes are paramount. Human resource development broadly includes programs addressing education, training, and knowledge management. The International Atomic Energy Agency’s Implementing Guide, Sustaining a Nuclear Security Regime, highlights the importance of national-level support for assigning resources that help ensure States are able to develop and retain sufficient human resources in the short, medium, and long term. Determining the resources needed to support education, training, and knowledge management is not an easy task, and knowledge management is a practice often overlooked when States plan for and allocate human resources for a nuclear security regime. The paper highlights the importance of implementing knowledge management practices as part of sustaining a nuclear security regime. Given the availability of secure web-based knowledge management tools, a nuclear security human resource development program should not depend solely on direct human interactions. To that end, the paper will offer an approach for planning and implementing a knowledge management system by using the U.S. Department of Energy/National Nuclear Security Administration’s Nuclear Smuggling Detection and Deterrence Knowledge Management Website as a case study. This example offers useful lessons learned for States considering or actively developing their own nuclear security knowledge management efforts and human resource development.

Tremonte, Matthew M.↗

SU-F-E-03: PET/CT Guided Dose Boost to Hypoxic Sub-Volume in Nasopharyngeal Carcinomas Using Self-Optimizing Non-Uniform VMAT

Purpose: This study is to evaluate the feasibility of simultaneously integrated boost (SIB) to hypoxic subvolume (HTV) in nasopharyngeal carcinomas under the guidance of 18F-Fluoromisonidazole (FMISO) PET/CT using a novel non-uniform volumetric modulated arc therapy (VMAT)technique. Methods: Eight nasopharyngeal carcinoma patients treated with conventional uniform VMAT were retrospectively analyzed. For each treatment, actual conventional uniform VMAT plan with two or more arcs (2–2.5 arcs, totally rotating angle < 1000o) was designed with dose boost to hopxic subvolume (total dose, 84Gy) in the gross tumor volme (GTV) under the guidance of 18F- FMISO PET/CT. Based on the same dataset, experimental single arc non-uniform VAMT plans were generated with the same dose prescription using customized software tools. Dosimetric parameters, quality assurance and the efficiency of the treatment delivery were compared between the uniform and non-uniform VMAT plans. Results: To develop the non-uniform VMAT technique, a specific optimization model was successfully established. Both techniques generate high-quality plans with pass rate (>98%) with the 3mm, 3% criterion. HTV received dose of 84.1±0.75Gy and 84.1±1.2Gy from uniform and non-uniform VMAT plans, respectively. In terms of target coverage and dose homogeneity, there was no significant statistical difference between actual and experimental plans for each case. However, for critical organs at risk (OAR), including the parotids, oral cavity and larynx, dosimetric difference was significant with better dose sparing form experimental plans. Regarding plan implementation efficiency, the average machine time was 3.5 minutes for the actual VMAT plans and 3.7 minutes for the experimental nonuniform VMAT plans (p>0.050). Conclusion: Compared to conventional VMAT technique, the proposed non-uniform VMAT technique has the potential to produce efficient and safe treatment plans, especially in cases with complicated anatomical structures and demanding dose boost to subvolumes.

60 APPLIED LIFE SCIENCES↗

Evaluation of Minimum Detectable Activities for Stack Sample Analyses

The Rad-NESHAP program takes samples at major point sources to track how much of select nuclides are being emitted out of the stack. Samples are taken at the site where the radiological operations are being performed. The samples are then sent to analytical laboratories for analysis to determine what nuclides exist in the sample. However, due to the sensitivity of the instruments, false positives are often reported. To reduce the number of false positives, the results reported from the analytical labs are compared to set detection limits. Anything below the set detection limit is considered part of the background while anything above the limit is considered a positive hit. Therefore, the detection limit must be set low enough that any false negatives do not result in a significant dose missed at the end of the year but high enough that there are not enough false positives to skew the annual dose being reported. All detection limits listed in this section for the analyses below were designed to meet the stated equivalent emissions rate and subsequent off-site doses. These minimum detectable activities (MDAs) were developed in the 1990s and documented in the memo cited for each analysis below. These limits and memos are all currently referenced in the Quality Assurance Project Plan (QAPP) for the Rad-NESHAP Compliance Task, which is being updated to a Project Implementation Plan (PIP) concurrently with this document. As part of this update process, the original MDAs defined in this section needed to be verified that they were still conservative and meet the off-site dose levels stated.

2019 MDA↗

Radiation Hardened Foam Cold Test Plan - Phase II: Foam Characterization Testing and Environmental Chamber Testing of FoamBag Fixative Foam

This document outlines the Phase II test objectives and implementation plan for a down-select foam fixative technology intended to facilitate activities in support of the Savannah River Site (SRS) F/H labs deactivation and decommissioning (D&D) efforts. It is a collaborative effort between Savannah River National Laboratory (SRNL), Florida International University (FIU), and the SRS F/H labs team intended to test and evaluate the potential of a polyurethane resin foam in mitigating the release of contamination during dismantling operations on radioactively contaminated piping in legacy facilities. The cold test plan addresses specific requirements highlighted by site and safety personnel and will be executed at FIU and SRNL test and lab facilities. Results from the cold tests will inform the hot test at F/H labs, which will use the foam fixative to confine and/or isolate residual contamination within a 3-dimensional void space of Hastelloy C-22 piping designated for removal from the area and transported to a designated disposal facility. Phase I testing was previously conducted using Hilti CP620 fixative foam. Results from Phase I testing indicate Hilti CP-620 fixative foam is incompatible with SRS site hot taps as an effective foam delivery method into Hastelloy C-22 piping. Phase II testing will be conducted using FoamBag TM fixative foam as an alternative fixative foam option. Phase II testing will address eight test objectives: (1) evaluation of the adhesion and bonding properties of FoamBag TM in Hastelloy C-22 piping, (2) evaluation of the adhesion of FoamBag TM in piping under various moisture conditions, (3) determination of the heat profile of FoamBag TM during curing, (4) determination of the internal pipe pressure after FoamBag TM deployment and curing, (5) conduct a leak test to determine if FoamBag TM is effective at creating a full seal within piping, (6) headspace testing of FoamBag TM to determine if there are any associated off-gas hazards during FoamBag TM curing, (7) conduct environmental chamber testing of FoamBag TM to understand how environmental parameters impacts FoamBag TM curing, and (8) conduct fire testing to evaluate FoamBag TM fire retardant characteristics.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Radiation Hardened Foam Cold Test Plan – Phase-I: Foam Adhesion, Contamination Fixation, Moisture Stresses, Pipe Cutting, and Thermal Profile Testing

This document outlines the Phase-I test objectives and implementation plan for a down-selective foam fixative technology intended to facilitate activities in support of the Savannah River Site (SRS) F/H labs deactivation and decommissioning (D&D) efforts. It is a collaborative effort between Savannah River National Laboratory (SRNL), Florida International University (FIU), and the SRS F/H labs team intended to test and evaluate the potential of an intumescent, fire-retardant foam in mitigating the release of contamination during dismantling operations on radioactively contaminated piping in legacy facilities. The cold test plan addresses specific requirements highlighted by site and safety personnel and will be executed in FIU’s Outdoor Test and Evaluation Facility using a mock-up that replicates the operational conditions at the proposed hot test location at F/H labs. Results from the cold test plan will inform the hot test at F/H labs, which will use the foam fixative to confine and/or isolate residual contamination within a 3-dimensional void space of Hastelloy C-22 piping designated for removal from the site and transported to a proper disposal facility. Phase-I testing will address eight test objectives: (1) evaluation of the adhesion and bonding properties of foam fixative in piping, (2) evaluation of the adhesion of the foam fixative in piping under varying moisture conditions, (3) determination of the heat profile of the foam fixative during curing, (4) determination of the relationship between pipe diameter and foam fixative quantity, (5) determination of the internal pipe pressure after foam deployment and curing, (6) development of a leak test standard operating procedure to test for the effectiveness of the foam plug, (7) initiation of a literature review to determine if using a hot tap is a viable method to deliver foam into piping, and (8) initiation of a 10-foot mock up test that will be used in Phase-II cold testing. The cold test will be conducted at FIU and all testing activities will comply with SRNL Conduct of R&D Protocols (SRNL-IM-2020-00019).

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Workshop on Establishing and Operating a National Nuclear Security Support Centre Hypothetical Scenario: “Centralia Nuclear Security Support Centre Technical Support Plan”

This plan outlines the systemic and coordinated management of the CNSSC technical support programme. In accordance with the CNSSC Strategy Implementation Plan and Memoranda of Understanding among stakeholders, Centralia Border Guards (CBG) and Centralia Nuclear Energy Agency (CNEA) will lead the effort to develop standardized approach to technical support and will provide technical support to the following CNSSC stakeholders: CBG, CNEA, Centralia National Police (CNP), Centralia Coast Guard (CCG), and CentrAtom/Centralia Nuclear Power Plant (CNPP).

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Optimizing Energy Use in Pulp & Paper with DOE’s Energy Intensive Industries Resources

The U.S. pulp and paper industry is the third-largest energy consumer in manufacturing, accounting for roughly 10% of sector energy use. Improving energy efficiency reduces operating costs and strengthens competitiveness. To support this effort, the U.S. Department of Energy (DOE), through Oak Ridge National Laboratory (ORNL), launched the Energy Intensive Industries (EII) Initiative. A two-year pilot across 45 industrial sites identified more than 4 trillion Btu/year in potential energy savings. This presentation outlines plans for a follow-up technical assistance program tailored to pulp and paper mills. Available resources include a cost-savings scoping tool, implementation planning guidance, and technical support for applying advanced methods such as Pinch Analysis for integrated process-utilities optimization. The session introduces key Pinch Analysis principles and highlights case studies demonstrating measurable improvements. ORNL also seeks industry feedback on barriers to efficiency improvements, including technology gaps and resource needs. DOE’s broader objective is to accelerate productivity and economic competitiveness across U.S. energy-intensive industries.

Kamath, Dipti [ORNL] (ORCID:0000000278739994)↗

SU-F-T-343: Dosimetric Investigation for Fluence Smoothing On VMAT Plans in Monaco for Head - Neck Cancers

Purpose: The study investigates the effect of fluence smoothing parameter on VMAT plans for ten head-neck cancer patients using Monaco5.00.04. Methods: VMAT plans were created using Monaco5.00.04 planning system for 10 head-neck patients. Four plans were generated for each patient using available smoothing parameters i.e. high, medium, low and off. The number of monitor units required to deliver 1 cGy was defined as a modulation degree; and was taken as a measure of plan complexity. Routinely used plan quality parameters Conformity index (CI) and Homogeneity index (HI) were used in the study. As a protocol our center, practices “medium” smoothing for clinical implementation. Plans with medium smoothing were opted as reference plans due to the clinical acceptance and dosimetric verifications made on these plans. Plans were generated by varying the smoothing parameter and re-optimization was done. The PTV was evaluated for D98%, D95%, D50%, D1% and prescription isodose volume (PIV). For critical organs; spine and parotids the parameters recorded were D1cc and Dmean respectively. Results: The cohort had the median prescription as 6000 cGy in the range of 6600 cGy - 4500 cGy. The modulation degree was observed to increase up to 6% from reference to the most complex plan. High smoothing had about 11% increase in segments which marginally (0.5 to 1%) increased the homogeneity index while conformity index remains constant. For spine the maximum D1cc was observed in medium smoothing as 4639.8 cGy, this plan was clinically accepted and dosimetrically verified. Similarly for parotids, the Dmean was 2011.9 cGy and 1817.05 cGy. Conclusion: The sensitivity of plan quality in terms of smoothing options (high, medium, low and off) available in Monaco 5.00.04 was resulted in minimal difference in terms of target coverage, conformity index and homogeneity index. Similarly changing smoothing did not result in any enhanced advantage in sparing of critical organs.

60 APPLIED LIFE SCIENCES↗