Search NASA⌕ Search

SEARCH · Search NASA

Results for “Induction period”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

The role of the distal elongation zone in the response of maize roots to auxin and gravity

We used a video digitizer system to (a) measure changes in the pattern of longitudinal surface extension in primary roots of maize (Zea mays L.) upon application and withdrawal of auxin and (b) compare these patterns during gravitropism in control roots and roots pretreated with auxin. Special attention was paid to the distal elongation zone (DEZ), arbitrarily defined as the region between the meristem and the point within the elongation zone at which the rate of elongation reaches 0.3 of the peak rate. For roots in aqueous solution, the basal limit of the DEZ is about 2.5 mm behind the tip of the root cap. Auxin suppressed elongation throughout the elongation zone, but, after 1 to 3 h, elongation resumed, primarily as a result of induction of rapid elongation in the DEZ. Withdrawal of auxin during the period of strong inhibition resulted in exceptionally rapid elongation attributable to the initiation of rapid elongation in the DEZ plus recovery in the main elongation zone. Gravistimulation of auxin-inhibited roots induced rapid elongation in the DEZ along the top of the root. This resulted in rapid gravitropism even though the elongation rate of the root was zero before gravistimulation. The results indicate that cells of the DEZ differ from cells in the bulk of the elongation zone with respect to auxin sensitivity and that DEZ cells play an important role in gravitropism.

NASA Discipline Plant Biology↗

Dispersion-Engineered Traveling Wave Kinetic Inductance Parametric Amplifier

A traveling wave kinetic inductance parametric amplifier comprises a superconducting transmission line and a dispersion control element. The transmission line can include periodic variations of its dimension along its length. The superconducting material can include a high normal state resistivity material. In some instances the high normal state resistivity material includes nitrogen and a metal selected from the group consisting of titanium, niobium and vanadium. The traveling wave kinetic inductance parametric amplifier is expected to exhibit a noise temperature below 100 mK/GHz.

Zmuidzinas, Jonas↗

Induction and repair of HZE induced cytogenetic damage

Wistar rats were exposed to high-mass, high energy (HZE) 56Fe particles (1000 GeV/AMU) using the Alternating Gradient Synchrotron (AGS). The animals were sacrificed at 1-5 hours or after a 30-day recovery period. The frequency of micronuclei in the tracheal and the deep lung epithelial cells were evaluated. The relative effectiveness of 56Fe, for the induction of initial chromosome damage in the form of micronuclei, was compared to damage produced in the same biological system exposed to other types of high and low-LET radiation. It was demonstrated that for animals sacrificed at short times after exposure, the tracheal and lung epithelial cells, the 56Fe particles were 3.3 and 1.3 times as effective as 60Co in production of micronuclei, respectively. The effectiveness was also compared to that for exposure to inhaled radon. With this comparison, the 56Fe exposure of the tracheal epithelial cells and the lung epithelial cells were only 0.18 and 0.20 times as effective as radon in the production of the initial cytogenetic damage. It was suggested that the low relative effectiveness was related to potential for 'wasted energy' from the core of the 56Fe particles. When the animals were sacrificed after 30 days, the slopes of the dose-response relationships, which reflect the remaining level of damage, decreased by a factor of 10 for both the tracheal and lung epithelial cells. In both cases, the slope of the dose-response lines were no longer significantly different from zero, and the r2 values were very high. Lung epithelial cells, isolated from the animals sacrificed hours after exposure, were maintained in culture, and the micronuclei frequency evaluated after 4 and 6 subcultures. These cells were harvested at 24 and 36 days after the exposure. There was no dose-response detected in these cultures and no signs of genomic instability at either sample time.

Non-NASA Center↗

Stability of Ceramics in Hydrogen between 4000 and 4500 F

The various reactions that are possible between hydrogen and certain ceramic materials are discussed as well as the means of measuring the extent of such reactions. Powdered carbides, nitrides, borides, and oxides were tested. These materials were heated inductively in a tungsten cup between 4000 and 4500 F for two 1-hour periods under a static hydrogen atmosphere. Weight, pressure, and diffraction pattern changes were observed, and these served to indicate the extent of reaction. Most of the ceramics, HfC, ZrC, TiC, TaC, NbC, WC, MO2C, HfN, ZrN, NbN, ZrB2, NbB2, and WB, showed less reaction than the minimum detectable value. However, the ceramics, TiN, TaN, HfB2, TiB2, ZrO2, and Cr2O3, apparently reacted to a measurable extent with hydrogen. Reactions of SiC, VC, and TaB2 with hydrogen were not determinable because of their incompatibility with the tungsten container.

May, Charles E.↗

Software Development for the Hobby-Eberly Telescope's Segment Alignment Maintenance System using LABView

The software development for an upgrade to the Hobby-Eberly Telescope (HET) was done in LABView. In order to improve the performance of the HET at the McDonald Observatory, a closed-loop system had to be implemented to keep the mirror segments aligned during periods of observation. The control system, called the Segment Alignment Maintenance System (SAMs), utilized inductive sensors to measure the relative motions of the mirror segments. Software was developed in LABView to tie the sensors, operator interface, and mirror-control motors together. Developing the software in LABView allowed the system to be flexible, understandable, and able to be modified by the end users. Since LABView is built using block diagrams, the software naturally followed the designed control system's block and flow diagrams, and individual software blocks could be easily verified. LABView's many built-in display routines allowed easy visualization of diagnostic and health-monitoring data during testing. Also, since LABView is a multi-platform software package, different programmers could develop the code remotely on various types of machines. LABView s ease of use facilitated rapid prototyping and field testing. There were some unanticipated difficulties in the software development, but the use of LABView as the software "language" for the development of SAMs contributed to the overall success of the project.

Hall, Drew P.↗

Comparative effects of selenite and selenate on nitrate assimilation in barley seedlings

The effect of SeO3= and SeO4= on NO3- assimilation in 8-d-old barley (Hordeum vulgare L.) seedlings was studied over a 24-h period. Selenite at 0.1 mol m-3 in the uptake solutions severely inhibited the induction of NO3- uptake and active nitrate reductases. Selenate, at 1.0 mol m-3 in the nutrient solution, had little effect on induction of activities of these systems until after 12 h; however, when the seedlings were pretreated with 1.0 mol m-3 SeO4= for 24 h, subsequent NO3- uptake from SeO4(=) -free solutions was inhibited about 60%. Sulphate partially alleviated the inhibitory effect of SeO3= when supplied together in the ambient solutions, but had no effect in seedlings pretreated with SeO3=. By contrast, SO4= partially alleviated the inhibitory effect of SeO4= even in seedlings pretreated with SeO4=. Since uptake of NO3- by intact seedlings was also inhibited by SO3=, the percentage of the absorbed NO3- that was reduced was not affected. By contrast, SeO4=, which affected NO3- uptake much less, inhibited the percentage reduced of that absorbed. However, when supplied to detached leaves, both SeO3= and SeO4= inhibited the in vivo reduction of NO3- as well as induction of nitrate reductase and nitrite reductase activities. Selenite was more inhibitory than SeO4= ; approximately a five to 10 times higher concentration of SeO4= than SeO3= was required to achieve similar inhibition. In detached leaves, the inhibitory effect of both SeO3= and SeO4= on in vivo NO3- reduction as well as on the induction of nitrate reductase activity was partially alleviated by SO4=. The inhibitory effects of Se salts on the induction of the nitrite reductase were, however, completely alleviated by SO4=. The results show that in barley seedlings SeO3= is more toxic than SeO4=. The reduction of SeO4= to SeO3= may be a rate limiting step in causing Se toxicity.

NASA Discipline Life Support Systems↗

The 22-year solar cycle - A heliospheric oscillation

A new mechanism is proposed for the origin of the 22-year solar cycle in which the solar cycle is caused by a large scale oscillation of the heliosphere. In its simplest terms the oscillation is directly analogous to an LC oscillator, with the heliospheric current system providing the inductance, and accumulated charge near the heliosphere boundary providing the capacitance. Estimates of the oscillation period using reasonable parameters are close to 22 years.

Gurnett, D. A.↗

Transient and Steady-state Tests of the Space Power Research Engine with Resistive and Motor Loads

The NASA Lewis Research Center (LeRC) has been testing free-piston Stirling engine/linear alternators (FPSE/LA) to develop advanced power convertors for space-based electrical power generation. Tests reported herein were performed to evaluate the interaction and transient behavior of FPSE/LA-based power systems with typical user loads. Both resistive and small induction motor loads were tested with the space power research engine (SPRE) power system. Tests showed that the control system could maintain constant long term voltage and stable periodic operation over a large range of engine operating parameters and loads. Modest resistive load changes were shown to cause relatively large voltage and, therefore, piston and displacer amplitude excursions. Starting a typical small induction motor was shown to cause large and, in some cases, deleterious voltage transients. The tests identified the need for more effective controls, if FPSE/LAs are to be used for stand-alone power systems. The tests also generated a large body of transient dynamic data useful for analysis code validation.

Rauch, Jeffrey S.↗

Theory of Metastable State Relaxation in a Gravitational Field for Non-Critical Binary Systems with Non-Conserved Order Parameter

A new mathematical ansatz is developed for solution of the time-dependent Ginzburg-Landau nonlinear partial differential equation describing metastable state relaxation in binary (solute+solvent) non-critical solutions with non-conserved scalar order parameter in presence of a gravitational field. It has been demonstrated analytically that in such systems metastability initiates heterogeneous solute redistribution which results in the formation of a non-equilibrium singly-periodic spatial solute structure in the new solute-rich phase. The critical radius of nucleation and the induction time in these systems are gravity-dependent. It has also been proved that metastable state relaxation in vertical columns of supersaturated non-critical binary solutions leads to formation of the solute concentration gradient. Analytical expression for this concentration gradient is found and analysed. It is concluded that gravity can initiate phase separation (nucleation or spinodal decomposition).

Izmailov, Alexander F.↗

Material Compatibility Study of Coated Metals to Maintain Biocidal Silver in a Spacecraft Potable Water System

Ionic silver-based biocide remains an option of choice for microbial control in spacecraft potable water systems. However, depletion of silver ions by wetted materials readily reduces ionic silver to nonbiocidal levels. This phenomenon occurs via various transport mechanisms at the liquid-solid interfaces between the silver-containing water and adjacent surfaces. Consequently, challenges remain in the design and/or selection of materials that can be used for the wetted system components that will help ensure silver is maintained at biocidal levels. Since silver has been baselined, and/or remains, as a potable water biocide option for several future spacecraft potable water systems, a multitiered approach is being investigated, looking at heritage materials, new processes, and/or alterative materials. This study conducted the application of eleven chemically-resistant coatings onto coupons that were cut out from three types of spacecraft-grade metals (Titanium Grade 2, Inconel 718, and 316L Stainless Steel) to investigate the performance of this material strategy as a barrier against silver depletion. In this investigation, the coated metals were immersed in a static 400 parts per billion silver biocide solution at a surface-area-to-volume ratio of 2.0 cm^(-1) and left to soak for predefined time periods. The concentration of the solution in contact with the coated samples was analyzed at various points via inductively coupled plasma mass spectrometry, and the measurements were interpreted as silver retention percentages over time. This paper summarizes the coating selection process, the configuration of the test, and the performance of each coating-metal combination at diminishing silver depletion. The preliminary results demonstrate that some of the selected coatings succeeded at maintaining biocidal silver concentrations far beyond the corresponding base metal in a similar test. The knowledge acquired through this investigation supports the deploying of coatings on plumbing lines for the integration of biocidal silver in the water system architecture of a spacecraft. Nevertheless, further testing must be continued to assess the performance of these coatings on other wetted geometries and any implications of unifying this material strategy with traditional and developmental engineering design processes for spacecraft potable water systems.

water↗

Material Compatibility Study of Coated Metals to Maintain Biocidal Silver in a Spacecraft Potable Water System

Ionic silver-based biocide is an option of strong interest for future exploration and has been baselined for several emerging spacecraft potable water systems. A challenge for the use of silver biocide remains the depletion of ionic silver on wetted materials of construction. Consequently, the design and/or selection of materials that can be used as the wetted system components need specific consideration. As part of the strategy to address this issue, a multitiered approach is being investigated that looks at combinations of conventional and non-conventional spacecraft treatment processes and materials. In this study, eleven chemically-resistant polymer coatings were applied as surface treatments onto coupons that were cut out from three types of conventional spacecraft-grade metals (Titanium Grade 2, Inconel 718, and 316L Stainless Steel). The coated metals were immersed in a static 400 parts per billion silver biocide solution at a surface-area-to-volume ratio of 2.0 cm^-1 and left to soak for predefined periods of time. The concentration of the solution in contact with the coated samples were then analyzed via inductively coupled plasma mass spectrometry, and the data used to determine the extent to which the coatings provided a barrier to silver loss. This paper summarizes the coating selection process, the configuration of the test, and the performance of each coating-metal combination as a mitigation to silver depletion. The preliminary results demonstrate that select coatings are proving effective at maintaining biocidal silver concentrations. The knowledge acquired through this investigation will be used to assess the feasibility of using these coatings as a robust strategy for maintaining biocidal silver in the water systems. Future studies are planned to assess the specific use of these coatings and to better understand the implications of utilizing this material approach in the future spacecraft potable water system designs.

coatings↗

Material Compatibility Study of Coated Metals to Maintain Biocidal Silver in a Spacecraft Potable Water System

Ionic silver-based biocide is an option of strong interest for future exploration and has been baselined for several emerging spacecraft potable water systems. A challenge for the use of silver biocide remains the depletion of ionic silver on wetted materials of construction. Consequently, the design and/or selection of materials that can be used as the wetted system components need specific consideration. As part of the strategy to address this issue, a multitiered approach is being investigated that looks at combinations of conventional and non-conventional spacecraft treatment processes and materials. In this study, eleven chemically-resistant polymer coatings were applied as surface treatments onto coupons that were cut out from three types of conventional spacecraft-grade metals (Titanium Grade 2, Inconel 718, and 316L Stainless Steel). The coated metals were immersed in a static 400 parts per billion silver biocide solution at a surface-area-to-volume ratio of 2.0 cm^-1 and left to soak for predefined periods of time. The concentration of the solution in contact with the coated samples were then analyzed via inductively coupled plasma mass spectrometry, and the data used to determine the extent to which the coatings provided a barrier to silver loss. This paper summarizes the coating selection process, the configuration of the test, and the performance of each coating-metal combination as a mitigation to silver depletion. The preliminary results demonstrate that select coatings are proving effective at maintaining biocidal silver concentrations. The knowledge acquired through this investigation will be used to assess the feasibility of using these coatings as a robust strategy for maintaining biocidal silver in the water systems. Future studies are planned to assess the specific use of these coatings and to better understand the implications of utilizing this material approach in the future spacecraft potable water system designs.

coatings↗

[Radiation Anticarcinogenesis by Thiazolidine Pro-drug]

The original goal of this work was to determine the capacity of selected aminothiols to modulate radiation induced cytotoxicity, mutagenesis and carcinogenesis in a human mammary epithelial cell line. The conclusions from this work are that WR-1065 is the "gold standard" for protection against radiation induced cytotoxicity, mutagenesis and carcinogenesis. While a potent radiation protector, WR-1065 is cytotoxic in vitro and in vivo. Our rationale for a study of the thiazolidine pro-drugs was that these compounds are neither toxic in vitro or in vivo. The results obtained during this funding period indicate that the thiazolidine pro-drugs are as potent as WR-1065 as protectors against radiation induced mutation induction, and thus presumably against radiation induced carcinogenesis. Our results indicate that the thiazolidine prodrugs are excellent candidates to test as non-toxic anticarcinogens for protecting astronauts from cancer induction during space travel.

Warters, Raymond L.↗

The Distribution of Cloud to Ground Lightning Strike Intensities and Associated Magnetic Inductance Fields Near the Kennedy Space Center

Lightning strike location and peak current are monitored operationally in the Kennedy Space Center (KSC) Cape Canaveral Air Force Station (CCAFS) area by the Cloud to Ground Lightning Surveillance System (CGLSS). The present study compiles ten years worth of CGLSS data into a database of near strikes. Using shuffle launch platform LP39A as a convenient central point, all strikes recorded within a 20-mile radius for the period of record O R ) from January 1, 1993 to December 31,2002 were included in the subset database. Histograms and cumulative probability curves are produced for both strike intensity (peak current, in kA) and the corresponding magnetic inductance fields (in A/m). Results for the full POR have application to launch operations lightning monitoring and post-strike test procedures.

Burns, Lee↗

Some dynamical properties of very strong double layers in a triple plasma device

Dynamical properties of very strong double layers seen in a differentially pumped triple plasma device are reported. These double layers are V-shaped. The following findings are discussed: (1) Disruptions in the double layer potential and in the plasma current occur when an inductance is placed in series with the bias supply between the sources in the external circuit. These disruptions, which can be highly periodic, are the result of a negative resistance region. (2) When reactances in the circuit are minimized, the double layer exhibits a jitter motion in position approximately equal to the double layer thickness. (3) When the bias between the sources is rapidly turned on, the initial phase in the double layer formation is the occurrence of a constant electric field for the first few microseconds. First the apparatus used in all of the work is discussed and then each of the three phenomena are considered.

Carpenter, T.↗

Electrodeposition of Metals in Microgravity Conditions

Metal electrodeposition may introduce various morphological variations depending on the electrolytic conditions including cell configurations. For liquid electrolytes, a precise study of these deposits may be complicated by convective motion due to buoyancy. Zero-gravity (0-G) condition provided by drop shaft or parabolic flight gives a straightforward mean to avoid this effect: we present here 0-G electrodeposition experiments, which we compare to ground experiments (1-G). Two electrochemical systems were studied by laser interferometry, allowing to measure the concentration variations in the electrolyte: copper deposition from copper sulfate aqueous solution and lithium deposition from an ionic liquid containing LiTFSI. For copper, concentration variations were in good agreement with theory. For lithium, an apparent induction time was observed for the concentration evolution at 1-G: due to this induction time and to the low diffusion coefficient in ionic liquid, the concentration variations were hardly measurable in the parabolic flight 0-G periods of 20 seconds.

Nishikawa, K.↗

Inductively Coupled Plasma Etching for Delineation of InAs/GaSb Pixels

We developed 320x256 Complimentary Barrier Infrared (CBIRD) focal plane array (FPA) for long wave infrared (LWIR) imaging application. The FPA layers grown by molecular beam epitaxy (MBE) had 300 periods 1.9 micro m thick absorber. The CBIRD arrays showed the mean dark current density of 2.2 x 10(exp -4) A/cm2, when 128 mV bias voltage was applied. The long wave cut off was observed at 8.8 micrometers at the 50% peak and the maximum quantum efficiency was 54% at 5.6 micrometers. The arrays had 81% fill factor with 97% operability with noise equivalent difference temperature (NE(delta)T) of 18.6 mK and a mean detectivity of D*=1.3 x 10(exp 11) Hz(exp 1/2)/W.

InAs/GaSb↗

Pulsed Inductive Plasma Acceleration: Performance Optimization Criteria

Optimization criteria for pulsed inductive plasma acceleration are developed using an acceleration model consisting of a set of coupled circuit equations describing the time-varying current in the thruster and a one-dimensional momentum equation. The model is nondimensionalized, resulting in the identification of several scaling parameters that are varied to optimize the performance of the thruster. The analysis reveals the benefits of underdamped current waveforms and leads to a performance optimization criterion that requires the matching of the natural period of the discharge and the acceleration timescale imposed by the inertia of the working gas. In addition, the performance increases when a greater fraction of the propellant is initially located nearer to the inductive acceleration coil. While the dimensionless model uses a constant temperature formulation in calculating performance, the scaling parameters that yield the optimum performance are shown to be relatively invariant if a self-consistent description of energy in the plasma is instead used.

Polzin, Kurt A.↗