Search NASA⌕ Search

SEARCH · Search NASA

Results for “Infrared imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Arctic Clouds Infrared Imaging Field Campaign Report

The Infrared Cloud Imager (ICI), a passive thermal imaging system, was deployed at the North Slope of Alaska site in Barrow, Alaska, from July 2012 to July 2014 for measuring spatial-temporal cloud statistics. Thermal imaging of the sky from the ground provides high radiometric contrast during night and polar winter when visible sensors and downward-viewing thermal sensors experience low contrast. In addition to demonstrating successful operation in the Arctic for an extended period and providing data for Arctic cloud studies, a primary objective of this deployment was to validate novel instrument calibration algorithms that will allow more compact ICI instruments to be deployed without the added expense, weight, size, and operational difficulty of a large-aperture onboard blackbody calibration source. This objective was successfully completed with a comparison of the two-year data set calibrated with and without the onboard blackbody. The two different calibration methods produced daily-average cloud amount data sets with correlation coefficient = 0.99, mean difference = 0.0029 (i.e., 0.29% cloudiness), and a difference standard deviation = 0.054. Finally, the ICI instrument generally detected more thin clouds than reported by other ARM cloud products available as of late 2015.

54 ENVIRONMENTAL SCIENCES↗

In situ calibration of an infrared imaging video bolometer in the Large Helical Device

The InfraRed imaging Video Bolometer (IRVB) is a powerful diagnostic to measure multi-dimensional radiation profiles in plasma fusion devices. In the Large Helical Device (LHD), four IRVBs have been installed with different fields of view to reconstruct three-dimensional profiles using a tomography technique. For the application of the measurement to plasma experiments using deuterium gas in LHD in the near future, the long-term effect of the neutron irradiation on the heat characteristics of an IRVB foil should be taken into account by regular in situ calibration measurements. Therefore, in this study, an in situ calibration system was designed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

In situ calibration of the foil detector for an infrared imaging video bolometer using a carbon evaporation technique

The InfraRed imaging Video Bolometer (IRVB) is a useful diagnostic for the multi-dimensional measurement of plasma radiation profiles. For the application of IRVB measurement to the neutron environment in fusion plasma devices such as the Large Helical Device (LHD), in situ calibration of the thermal characteristics of the foil detector is required. Laser irradiation tests of sample foils show that the reproducibility and uniformity of the carbon coating for the foil were improved using a vacuum evaporation method. Also, the principle of the in situ calibration system was justified.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Experimental Visualizations of a Generic Launch Vehicle Flow Field: Time-Resolved Shadowgraph and Infrared Imaging

Time-Resolved shadowgraph and infrared (IR) imaging were performed to investigate off-body and on-body flow features of a generic, 'hammer-head' launch vehicle geometry previously tested by Coe and Nute (1962). The measurements discussed here were one part of a large range of wind tunnel test techniques that included steady-state pressure sensitive paint (PSP), dynamic PSP, unsteady surface pressures, and unsteady force measurements. Image data was captured over a Mach number range of 0.6 less than or equal to M less than or equal to 1.2 at a Reynolds number of 3 million per foot. Both shadowgraph and IR imagery were captured in conjunction with unsteady pressures and forces and correlated with IRIG-B timing. High-speed shadowgraph imagery was used to identify wake structure and reattachment behind the payload fairing of the vehicle. Various data processing strategies were employed and ultimately these results correlated well with the location and magnitude of unsteady surface pressure measurements. Two research grade IR cameras were positioned to image boundary layer transition at the vehicle nose and flow reattachment behind the payload fairing. The poor emissivity of the model surface treatment (fast PSP) proved to be challenging for the infrared measurement. Reference image subtraction and contrast limited adaptive histogram equalization (CLAHE) were used to analyze this dataset. Ultimately turbulent boundary layer transition was observed and located forward of the trip dot line at the model sphere-cone junction. Flow reattachment location was identified behind the payload fairing in both steady and unsteady thermal data. As demonstrated in this effort, recent advances in high-speed and thermal imaging technology have modernized classical techniques providing a new viewpoint for the modern researcher

Shadowgraph↗

The utilization of an infrared imaging system as a cooling slot blockage detector in the inspection of a transpiration cooled nozzle

A comprehensive examination of the 8 foot temperature tunnel's transpiration cooled nozzle was completed using an infrared imaging radiometer to locate regions of cooling flow irregularities caused by obstruction of three or more adjacent cooling slots. Restrictions in the cooling flow were found and cataloged. Blockages found were due primarily to the presence of residual phosphoric acid being discharged from some of the cooling slots. This acid was used during construction of the nozzle components and was to have been purged prior to its delivery to the NASA Langley Research Center (LaRC). In addition, a radial displacement of one selection of discs located in the spool piece was inspected and cataloged for future reference. There did not seem to be a serious restriction of flow in this defect, but evidence from the infrared images indicated reduced slot activity within the gouge. The radiometer survey uncovered regions where closer inspection is recommended but did not cover the entire surface area of the three nozzle subsections due to equipment limitations. A list of areas with suspected problems is included in Appendix A.

Borg, Stephen E.↗

A sensitive infrared imaging up converter and spatial coherence of atmospheric propagation

An infrared imaging technique based on the nonlinear interaction known as upconversion was used to obtain images of several astronomical objects in the 10 micrometer spectral region, and to demonstrate quantitatively the sharper images allowed for wavelengths beyond the visible region. The deleterious effects of atmospheric inhomogeneities on telescope resolution were studied in the infrared region using the technique developed. The low quantum efficiency of the device employed severely limited its usefulness as an astronomical detector.

Boyd, R. W.↗

Ground-based near-infrared imaging observations of Venus during the Galileo encounter

Near-infrared images of Venus, obtained from a global network of ground-based observatories during January and February 1990, document the morphology and motions of the night-side near-infrared markings before, during, and after the Galileo Venus encounter. A dark cloud extended halfway around the planet at low latitudes and persisted throughout the observing program. It had a rotation period of 5.5 + or - 0.15 days. The remainder of this latitude band was characterized by small-scale (400 to 1000 km) dark and bright markings with rotation periods of 7.4 + or - 1 days. The different rotation periods for the large dark cloud and the smaller markings suggest that they are produced at different altitudes. Midlatitudes (+ or - 40 to 60 deg) were usually occupied by bright east-west bands. The highest observable latitudes (+ or - 60 deg to 70 deg) were always dark and featureless, indicating greater cloud opacity. Maps of the water vapor distribution show no evidence for large horizontal gradients in the lower atmosphere of Venus.

Crisp, D.↗

NOAA-20 Visible Infrared Imaging Radiometer Suite day–night band on-orbit calibration and performance

The NOAA-20 Visible Infrared Imaging Radiometer Suite (VIIRS) instrument has been successfully operating on orbit since November 28, 2017. The day–night band (DNB) onboard NOAA-20 VIIRS is a panchromatic channel covering wavelengths from 0.5 to 0.9 μm, capable of observing the Earth scene in visible/near-infrared spectral range at a spatial resolution of 750 m. The DNB operates at low-, mid-, or high-radiometric gain stages, and it uses an onboard solar diffuser (SD) panel for low-gain stage calibration. The SD observations also provide a means to compute gain ratios between low-to-mid and mid-to-high-gain stages. With their large dynamic range and high sensitivity, the DNB detectors can make observations during both daytime and nighttime. We provide an assessment of the DNB on-orbit performance and behavior in the first two-year mission period and beyond. The calibration methodology used by the VIIRS Characterization Support Team in support of the NASA Earth science community has been described. The trending of on-board calibrators dark-offsets, SD gains, and gain ratios, and signal-to-noise ratio at minimum radiance have been analyzed, especially during key events such as the nadir and cryocooler doors opening. Furthermore, we performed intercomparison studies between Suomi National Polar-orbiting Partnership and NOAA-20 instruments and evaluated DNB radiometric calibration and characterization, including the SD degradation, detector gains, gain ratios, and straylight correction, as well as the calibration comparison between the NOAA Interface Data Processing Segment look-up-tables and our delivery results.

VIIRS↗

Infrared Images of Boundary Layer Transition on the D8 Transport Configuration in the LaRC 14- by 22-Foot Subsonic Tunnel

Grit, trip tape, or trip dots are routinely applied on the leading-edge regions of the fuselage, wings, tails or nacelles of wind tunnel models to trip the flow from laminar to turbulent. The thickness of the model's boundary layer is calculated for nominal conditions in the wind tunnel test to determine the effective size of the trip dots, but the flow over the model may not transition as intended for runs with different flow conditions. Temperature gradients measured with an infrared camera can be used to detect laminar to turbulent boundary layer transition on a wind tunnel model. This non-intrusive technique was used in the NASA Langley 14- by 22-Foot Subsonic Tunnel to visualize the behavior of the flow over a D8 transport configuration model. As the flow through the wind tunnel either increased to or decreased from the run conditions, a sufficient temperature difference existed between the air and the model to visualize the transition location (due to different heat transfer rates through the laminar and the turbulent boundary layers) for several runs in this test. Transition phenomena were visible without active temperature control in the atmospheric wind tunnel, whether the air was cooler than the model or vice-versa. However, when the temperature of the model relative to the air was purposely changed, the ability to detect transition in the infrared images was enhanced. Flow characteristics such as a wing root horseshoe vortex or the presence of fore-body vortical flows also were observed in the infrared images. The images of flow features obtained for this study demonstrate the usefulness of current infrared technology in subsonic wind tunnel tests.

Mason, Michelle L.↗

Visible and infrared imaging radiometers for ocean observations

The technology of visible and infrared imaging sensors designed for the remote monitoring of the oceans is assessed. Emphasis is placed on multichannel scanning radiometers that are either operational or under development. Present design practices and parameter constraints are discussed. Airborne sensor systems examined include the Ocean Color Scanner (OCS) and the Ocean Temperature Scanner (OTS). The Coastal Zone Color Scanner (CZCS) and Advanced Very High Resolution Radiometer (AVHRR), are reviewed with emphasis on design specifications, expected completion, and anticipated performance. Finally, recent technology advances and their probable impact on sensor design are examined.

Barnes, W. L.↗

An Imaging Infrared (IIR) seeker using a microprogrammed processor

A recently developed Imaging Infrared Seeker uses a microprogrammed processor to perform gimbal servo control and system interface while performing the seeker functions of automatic target detection, acquisition, and tracking. The automatic detection mode requires up to 80% of the available capability of a high performance microprogrammed processor. Although system complexity was increased significantly, this approach can be cost effective when the basic computation capacity is already available.

Richmond, K. V.↗

Development of an infrared imaging system for the surface tension driven convection experiment

An infrared imaging system is used to quantify the imposed surface temperature distribution along a liquid/gas free surface in support of the Surface Tension Driven Convection Experiment, a planned Space Transportation System flight experiment. For ground-based work a commercially available instrument was used to determine the feasibility of using the type of imaging system for this experiment. The ground-based work was used as a baseline for compiling specifications for a flight qualified imager to be designed, fabricated, tested and qualified for flight. The requirements and specifications for the flight model are given along with the reasons for departures from the ground-based equipment. The flight qualification requirements discussed are a representative sample of the necessary procedures which must be followed to flight qualify diagnostic equipment for use aboard the STS. The potential problems and concerns associated with operating an imaging system in orbit are also discussed.

Pline, Alexander D.↗

Development of an infrared imaging system for the surface tension driven convection experiment

An infrared imaging system is used to quantify the imposed surface temperature distribution along a liquid/gas free surface in support of the Surface Tension Driven Convection Experiment, a planned Space Transportation System flight experiment. For ground-based work a commercially available instrument was used to determine the feasibility of using this type of imaging system for this experiment. The ground-based work was used as a baseline for compiling specifications for a flight qualified imager to be designed, fabricated, tested and qualified for flight. The requirements and the specifications for the flight model are given along with the reasons for departures from the ground-based equipment. The flight qualification requirements discussed are a representative sample of the necessary procedures which must be followed to flight qualify diagnostic equipment for use aboard the STS. The potential problems and concerns associated with operating an imaging system on orbit are also discussed.

Pline, Alexander D.↗

Characterization and Application of Artificial Light Sources for Nighttime Aerosol Optical Depth Retrievals using the Visible Infrared Imager Radiometer Suite Day/Night Band

Using nighttime observations from Visible Infrared Imager Radiometer Suite (VIIRS) Day/Night band (DNB), the characteristics of artificial light sources are evaluated as functions of observation conditions, and incremental improvements are documented on nighttime aerosol retrievals using VIIRS DNB data on a regional scale. We find that the standard deviation of instantaneous radiance for a given artificial light source is strongly dependent upon the satellite viewing angle but is weakly dependent on lunar fraction and lunar angle. Retrieval of nighttime aerosol optical thickness (AOT) based on the novel use of these artificial light sources is demonstrated for three selected regions (United States, Middle East and India) during 2015. Reason-able agreement is found between nighttime AOTs from the VIIRS DNB and temporally adjacent daytime AOTs from the AErosol RObotic NETwork (AERONET) as well as from coincident nighttime AOT retrievals from the Cloud-Aerosol Lidar with Orthogonal Polarization (CALIOP), indicating the potential of this method to begin filling critical gaps in diurnal AOT information at both regional and global scales. Issues related to cloud, snow and ice contamination during the winter season, as well as data loss due to the misclassification of thick aerosol plumes as clouds, must be addressed to make the algorithm operationally robust.

Jianglong Zhang↗

Infrared imaging of Mars for volatile distribution and seasonal variability between 2.4 and 5.1 microns

Recent advances in ground-based infrared imaging now allow for sub-arc second spectral imaging. Data collected at the NASA Infrared Telescope Facility using protocam, a 62 x 58 InSb array camera with a circular variable filter and a plate scale 0.2 arc-seconds/pixel, are discussed. These images are a first attempt at extended seasonal infrared coverage of Mars to look for seasonal variations. Currently, data collected in Jun. 1990 at Ls = 241 (southern spring) and in Jan. 1991 Ls = 360 (late southern summer) are being reduced and analyzed. The 3 micron bound water band is the strongest surface absorption feature on Mars in the infrared. Infrared spectroscopy can also be useful in the detection of ice and frost deposits, especially in the polar regions. While imaging and spectroscopy at visible wavelengths allows for the detection of condensates, infrared information is needed to distinguish between water and CO2 ice/frost deposits. In the Jun. images, the southern polar cap totally disappears in the 3.4 micron CO2 frost band and is bright in the 3.1 micron water ice band, indicating that water ice is not a detectable component of the southern polar cap at this season. Further investigations are currently under way to look for residual water ice after the disappearance of the seasonal south polar cap in the Jan. images. The Jun. images that were focused on had a sub-earth point located at 184 longitude, and 23.8 S latitude which put the center of the disk in the southern highland region between Elysium and Amazonis. Examination of the Jun. images show that there are four surface units identifiable: a CO2 frost deposit, a northern plains unit, an equatorial unit, and a southern highland unit. At this resolution there does not appear to be any latitudinal variations in the 3 micron band that is independent of the 2.4 micron albedo features. The northern planes unit and the southern highland unit have very similar 'color' in the three micron band as demonstrated by the rise out of the band, but different brightness levels. The equatorial unit has a distinct three micron color implying a compositional difference. The albedo features at 2.4 microns have decreased contrast at longer wavelengths, till they are unrecognizable at 4 microns.

Blaney, Diana L.↗

Requirements for a Moderate-Resolution Infrared Imaging Sounder (MIRIS)

The high cost of imaging and sounding from space warrants exploration of new methods for obtaining the required information, including changing the spectral band sets, employing new technologies and merging instruments. In some cases we must consider relaxation of the current capability. In others, we expect higher performance. In general our goal is to meet the VIIRS and CrIS requirements while providing the enhanced next generation capabilities: 1) Hyperspectral Imaging in the Vis/NIR bands, 2) High Spatial Resolution Sounding in the Infrared bands. The former will improve the accuracy of ocean color products, aerosols and water vapor, surface vegetation and geology. The latter will enable the high-impact achieved by the current suite of hyperspectral infrared sounders to be achieved by the next generation high resolution forecast models. We examine the spectral, spatial and radiometric requirements for a next generation system and technologies that can be applied from the available inventory within government and industry. A two-band grating spectrometer instrument called the Moderate-resolution Infrared Imaging Sounder (MIRIS) is conceived that, when used with the planned NASA PACE Ocean Color Instrument (OCI) will meet the vast majority of CrIS and VIIRS requirements in the all bands and provide the next generation capabilities desired. MIRIS resource requirements are modest and the Technology Readiness Level is high leading to the expectation that the cost and risk of MIRIS will be reasonable.

Atmospheric Infrared Sounder (AIRS)↗