Search NASA⌕ Search

SEARCH · Search NASA

Results for “Inhalation Dose”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Inhalation and Ingestion Intakes with Associated Dose Estimates for Level II and Level III Personnel Using Capstone Study Data

Depleted uranium (DU) intake rates and subsequent dose rates were estimated for personnel entering armored combat vehicles perforated with DU penetrators (level II and level III personnel) using data generated during the Capstone Depleted Uranium (DU) Aerosol Study. Inhalation intake rates and associated dose rates were estimated from cascade impactors worn by sample recovery personnel and from cascade impactors that served as area monitors. Ingestion intake rates and associated dose rates were estimated from cotton gloves worn by sample recovery personnel and from wipe test samples from the interior of vehicles perforated with large caliber DU munitions. The mean DU inhalation intake rate for level II personnel ranged from 0.447 mg h-1 based on breathing zone monitor data (in and around a perforated vehicle) to 14.5 mg h-1 based on area monitor data (in a perforated vehicle). The mean DU ingestion intake rate for level II ranged from 4.8 mg h-1 to 38.9 mg h-1 based on the wipe test data including surface to glove transfer factors derived from the Capstone data. Based on glove contamination data, the mean DU ingestion intake rates for level II and level III personnel were 10.6 mg h-1 was and 1.78 mg h-1, respectively. Effective dose rates and peak kidney uranium concentration rates were calculated based on the intake rates. The peak kidney uranium concentration rate cannot be multiplied by the total exposure duration when multiple intakes occur because uranium will clear from the kidney between the exposures.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Coefficients for Estimating Prenatal Dose in Pregnant Workers from Acute Intakes

Inhalation and ingestion dose coefficients for the embryo and fetus from intakes of radionuclides by the mother are provided in the International Commission on Radiological Protection (ICRP) Publication 88 for intake of each of 74 radionuclides. To address the many other possible radionuclides to which workers may be exposed, effective dose coefficients were developed for the embryo/fetus for all additional radionuclides addressed in ICRP Publication 107 with half-life of 10 min or more. The general approach was to use the estimated dose to the mother’s uterus during pregnancy as a scalable proxy for the dose to the embryo/fetus. The set of scaling factors used in the study was derived from analyses of the relationships of the dose to the mother’s uterus and the effective dose to the embryo/fetus for the ~400 cases (considering two intake modes and multiple forms of many of the radionuclides) addressed in Publication 88.

61 RADIATION PROTECTION AND DOSIMETRY↗

Reliability of Current Biokinetic and Dosimetric Models for Radionuclides: A Pilot Study

This report describes the results of a pilot study of the reliability of the biokinetic and dosimetric models currently used by the U.S. Nuclear Regulatory Commission (NRC) as predictors of dose per unit internal or external exposure to radionuclides. The study examines the feasibility of critically evaluating the accuracy of these models for a comprehensive set of radionuclides of concern to the NRC. Each critical evaluation would include: identification of discrepancies between the models and current databases; characterization of uncertainties in model predictions of dose per unit intake or unit external exposure; characterization of variability in dose per unit intake or unit external exposure; and evaluation of prospects for development of more accurate models. Uncertainty refers here to the level of knowledge of a central value for a population, and variability refers to quantitative differences between different members of a population. This pilot study provides a critical assessment of models for selected radionuclides representing different levels of knowledge of dose per unit exposure. The main conclusions of this study are as follows: (1) To optimize the use of available NRC resources, the full study should focus on radionuclides most frequently encountered in the workplace or environment. A list of 50 radionuclides is proposed. (2) The reliability of a dose coefficient for inhalation or ingestion of a radionuclide (i.e., an estimate of dose per unit intake) may depend strongly on the specific application. Multiple characterizations of the uncertainty in a dose coefficient for inhalation or ingestion of a radionuclide may be needed for different forms of the radionuclide and different levels of information of that form available to the dose analyst. (3) A meaningful characterization of variability in dose per unit intake of a radionuclide requires detailed information on the biokinetics of the radionuclide and hence is not feasible for many infrequently studied radionuclides. (4) The biokinetics of a radionuclide in the human body typically represents the greatest source of uncertainty or variability in dose per unit intake. (5) Characterization of uncertainty in dose per unit exposure is generally a more straightforward problem for external exposure than for intake of a radionuclide. (6) For many radionuclides the most important outcome of a large-scale critical evaluation of databases and biokinetic models for radionuclides is expected to be the improvement of current models. Many of the current models do not fully or accurately reflect available radiobiological or physiological information, either because the models are outdated or because they were based on selective or uncritical use of data or inadequate model structures. In such cases the models should be replaced with physiologically realistic models that incorporate a wider spectrum of information.

61 RADIATION PROTECTION AND DOSIMETRY↗

Insulation Activation and Contamination in Low-Power Experiments

Among the diverse advanced nuclear reactor concepts being developed are designs that expect to operate at much higher temperatures than conventional light-water reactors, and therefore require alternative materials for components capable of withstanding these extreme temperatures. Insulation is one such component where alternative high-temperature industrial composites are being considered. Low-power experiments can provide an opportunity for advancing our understanding of material behavior under irradiation; however, these experiments are not without occupational hazards. The focus of this paper is the potential for activation of insulating composites when exposed to neutron fluence during reactor experiments, and to discuss the subsequent contamination of the testing area. This paper will also discuss practical measures for preventing the creation and inhalation of activated particulate matter (i.e., dust), such as engineering and administrative controls and personal protective equipment. This paper evaluates the suitability of several insulation materials for use in reactor experiments based on their activation from neutron irradiation. The materials considered are Pyrogel XTE by Aspen Aerogel, Cerablanket and Kaowool by Morgan Advanced Materials, Thermo-12 Gold by Johns Manville, and Maxsil CF6-2000 by McAllister Mills. Although these materials are not yet widely used in the nuclear industry, they are common in other industries due to their thermal insulating properties. These materials produce dust while handling that can pose health and safety hazards, which could be further exacerbated by activation. The analysis presented in this paper utilizes a deterministic method developed to predict the activation source term of the provided insulation materials. The method calculates the atomic density of each element within the composites and simulates their exposure to a specified neutron flux density representative of low power experimental conditions. During the irradiation phase and throughout the extensive cooling period, neutron absorptions and nuclear decays are tracked for relevant isotopes. The residual activity within each composite is then assessed to identify the material with the lowest potential radiological hazard to workers. Dust will be created during installation and removal of insulating materials and may also be generated during the experiment. Contamination of surrounding surfaces due to dispersion is highly likely unless preventative measures are taken. The results of this analysis are used to estimate an internal dose from inhalation of activated dust, which is significantly lower than the allowable whole-body dose. However, the risk of internal exposure may increase if the dust becomes a transport vector for nuclear material. The goals of this paper are to enhance the understanding of the potential activation and contamination hazards from the use of these insulating materials in low-power nuclear experiments and to foster safer work environments through informed decision-making and strategic planning. This work ultimately contributes to a broader understanding of how new non-nuclear materials for advanced reactors impact the radiological safety of co-located workers, helping to ensure the responsible management of radioactive materials during installation and decommissioning activities.

12 - MGMT OF RADIOACTIVE AND NON-RADIOACTIVE WASTE↗

Specific Blood Absorption Parameters for 239 PUO 2 and 238 PUO 2 Nanoparticles and Impacts on Bioassay Interpretation

We have determined specific absorption parameters for 239 PuO 2 and 238 PuO 2 based on available biokinetic data from studies in rodents, and the impacts of these parameters on bioassay interpretation and dosimetry after inhalation of nanoPuO 2 materials have been evaluated. Calculations of activities after an acute intake of nanoparticles of 239 PuO 2 and 238PuO 2 are compared with the corresponding calculations using standard default absorption parameters using the International Commission on Radiological Protection (ICRP) 66 respiratory tract model. Committed effective doses are also evaluated and compared. In this case, it was found that interpretation of bioassay measurements with the assumption that the biokinetic behaviour of PuO 2 nanoparticles is the same as that of micrometre-sized particles can result in an overprediction of the committed effective dose by two orders of magnitude. Although in this case the use of the default assumptions (5 µm AMAD, Type S) for assessing dose following inhalation exposure to airborne PuO 2 nanoparticles appears to be conservative, the evaluation of situations involving PuO 2 nanoparticles that may have different particle size and solubility properties should prudently follow the ICRP recommendation to obtain and use additional, material-specific information whenever possible.

61 RADIATION PROTECTION AND DOSIMETRY↗

Comparison of Different Internal Dosimetry Systems for Selected Radionuclides Important to Nuclear Power Production

This report compares three different radiation dosimetry systems currently applied by various U.S. Federal agencies and dose estimates based on these three dosimetry systems for a set of radionuclides often identified in power reactor effluents. These dosimetry systems were developed and applied by the International Commission on Radiological Protection at different times over the past six decades. Two primary modes of intake of radionuclides are addressed: ingestion in drinking water and inhalation. Estimated doses to individual organs and to the whole body based on each dosimetry system are compared for each of four age groups: infant, child, teenager, and adult. Substantial differences between dosimetry systems in estimated dose per unit intake are found for some individual radionuclides, but differences in estimated dose per unit intake generally are modest for mixtures of radionuclides typically found in nuclear power plant effluents.

biokinetics↗

Factors determining the exposure of dairy farmers to thoracic organic dust

Highlights: • Dairy farming exposes to thoracic dusts containing bacteria and moulds. • Specific tasks and farm characteristics control exposures to thoracic organic dusts. • Temperature and hygrometry also control the levels of organic dust exposure. Bronchial respiratory diseases are more common in dairy farmers than in the general population, perhaps because the repeated inhalation of organic dust contributes to the development of these disorders. However, the factors determining the exposure of farmers to particles that can enter the lower bronchial tract and interact with it, i.e. the thoracic fraction of the inhalable dust, remain to be identified. We therefore measured the exposure of dairy farmers to thoracic organic dust and identified the farm features and tasks that increased exposure. We measured thoracic particles (n = 110) and farm characteristics and occupational tasks in 29 Brittany dairy farms. The mean (GM) (geometric standard deviation, GSD) concentration of thoracic dust in air inhaled by farmers was 0.24 mg/m{sup 3} (2.8) and the concentrations of endotoxins, Gram-positive bacteria and fungi in the thoracic fraction were 128 EU/m{sup 3} (4.0), 960 CFU/m{sup 3} (6.3) and 690 CFU/m{sup 3} (5.4), respectively. Model-based estimates of the association between exposure, farm features and tasks indicated that manual grain and feed handling and mechanical bedding spreading significantly increased exposure to thoracic dust, endotoxins, bacteria and fungi. Exposure to bacteria and fungi was reduced by cowsheds divided into cubicles, whereas using automatic muck scrappers in alleyway and automatic milking tended to increase exposure to bacteria and endotoxins. Finally, exposure to endotoxin and fungi were reduced by warmer farm buildings and well-ventilated buildings having walls with large openings. In conclusions, major occupational tasks and specific farm features determine the exposure of Breton dairy farmers to thoracic organic dust.

54 ENVIRONMENTAL SCIENCES↗

Application of Multi-Criteria Decision Analysis Techniques for Informing Select Agent Designation and Decision Making

The Centers for Disease Control and Prevention (CDC) Select Agent Program establishes a list of biological agents and toxins that potentially threaten public health and safety, the procedures governing the possession, utilization, and transfer of those agents, and training requirements for entities working with them. Every 2 years the Program reviews the select agent list, utilizing subject matter expert (SME) assessments to rank the agents. In this study, we explore the applicability of multi-criteria decision analysis (MCDA) techniques and logic tree analysis to support the CDC Select Agent Program biennial review process, applying the approach broadly to include non-select agents to evaluate its generality. We conducted a literature search for over 70 pathogens against 15 criteria for assessing public health and bioterrorism risk and documented the findings for archiving. The most prominent data gaps were found for aerosol stability and human infectious dose by inhalation and ingestion routes. Technical review of published data and associated scoring recommendations by pathogen-specific SMEs was found to be critical for accuracy, particularly for pathogens with very few known cases, or where proxy data (e.g., from animal models or similar organisms) were used to address data gaps. Analysis of results obtained from a two-dimensional plot of weighted scores for difficulty of attack (i.e., exposure and production criteria) vs. consequences of an attack (i.e., consequence and mitigation criteria) provided greater fidelity for understanding agent placement compared to a 1-to-n ranking and was used to define a region in the upper right-hand quadrant for identifying pathogens for consideration as select agents. A sensitivity analysis varied the numerical weights attributed to various properties of the pathogens to identify potential quantitative (x and y) thresholds for classifying select agents. The results indicate while there is some clustering of agent scores to suggest thresholds, there are still pathogens that score close to any threshold, suggesting that thresholding “by eye” may not be sufficient. The sensitivity analysis indicates quantitative thresholds are plausible, and there is good agreement of the analytical results with select agent designations. A second analytical approach that applied the data using a logic tree format to rule out pathogens for consideration as select agents arrived at similar conclusions.

60 APPLIED LIFE SCIENCES↗

Application of multi-criteria decision analysis techniques and decision support framework for informing select agent designation for agricultural animal pathogens

The United States Department of Agriculture (USDA), Division of Agricultural Select Agents and Toxins (DASAT) established a list of biological agents and toxins (Select Agent List) that potentially threaten agricultural health and safety, the procedures governing the transfer of those agents, and training requirements for entities working with them. Every 2 years the USDA DASAT reviews the Select Agent List, using subject matter experts (SMEs) to perform an assessment and rank the agents. To assist the USDA DASAT biennial review process, we explored the applicability of multi-criteria decision analysis (MCDA) techniques and a Decision Support Framework (DSF) in a logic tree format to identify pathogens for consideration as select agents, applying the approach broadly to include non-select agents to evaluate its robustness and generality. We conducted a literature review of 41 pathogens against 21 criteria for assessing agricultural threat, economic impact, and bioterrorism risk and documented the findings to support this assessment. The most prominent data gaps were those for aerosol stability and animal infectious dose by inhalation and ingestion routes. Technical review of published data and associated scoring recommendations by pathogen-specific SMEs was found to be critical for accuracy, particularly for pathogens with very few known cases, or where proxy data (e.g., from animal models or similar organisms) were used to address data gaps. The MCDA analysis supported the intuitive sense that select agents should rank high on the relative risk scale when considering agricultural health consequences of a bioterrorism attack. However, comparing select agents with non-select agents indicated that there was not a clean break in scores to suggest thresholds for designating select agents, requiring subject matter expertise collectively to establish which analytical results were in good agreement to support the intended purpose in designating select agents. The DSF utilized a logic tree approach to identify pathogens that are of sufficiently low concern that they can be ruled out from consideration as a select agent. In contrast to the MCDA approach, the DSF rules out a pathogen if it fails to meet even one criteria threshold. Both the MCDA and DSF approaches arrived at similar conclusions, suggesting the value of employing the two analytical approaches to add robustness for decision making.

60 APPLIED LIFE SCIENCES↗

FGR 13 Dose Conversion Factor Files

The purpose of this document is to discuss the construction of two MACCS dose conversion factor (DCF) files in some detail, an older file created in 2007 named FGR13DCF.inp and a newer file created in 2018 called FGR13GyEquiv_RevA.inp. Very briefly, the difference between the two files is that the older file follows the standard conventions of assigning a radiation weighting factor of 20 for alpha radiation for all tissues and organs; whereas, the newer file complies with the FGR 13 health effects modeling and uses modified radiation weighting factors (referred to as relative biological effectiveness (RBE) factors) for alpha radiation of 10 for breast and of 1 for red bone marrow. During an intermediate period the creation of these two DCF files, a file called FGR13GyEquiv was created and used for the SOARCA calculations. This file was not released to the MACCS user community, but it is also discussed briefly in this document. DCF files are used by MACCS to convert air and ground radionuclide concentrations to doses to an organ or to the whole body. The MACCS calculation considers duration and shielding factor for each exposure pathway including cloudshine, groundshine, inhalation, and ingestion. Dose coefficients for cloudshine and groundshine are expressed as dose rates; dose coefficients for inhalation and ingestion are expressed as committed doses. In this document, dose coefficients (newer ICRP terminology) is used to describe the values contained in dose conversion factor (older ICRP terminology) files.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

220 Rn (Thoron) Geohazard in Room Air of Earthen Dwellings in Vietnam

Thoron’s ( 220 Rn) contribution to α -radiation exposure is usually considered negligible compared to that of 222 Rn (radon). Despite its short half-life of 55.6 seconds, thoron can be exhaled from porous surface layers of building materials into indoor air where people subsequently inhale radioisotopes, including metallic radioactive progeny. Bare surfaces of dry porous soil with relatively high 232 Th content can pose a thoron radiation hazard in indoor air. On northern Vietnam’s Dong Van karst plateau, the spatial distribution of thoron was determined in indoor air of traditional earthen and other types of dwellings using portable RAD7 and SARAD® RTM 2200 detectors. “Mud houses” are constructed with local compacted soil and typically do not have any floor or wall coverings (i.e., no plaster, wallpaper, or paint). Detailed measurements in a mud house revealed levels of thoron in room air averaging >500 Bq m -3 . The spatial distribution of α -radiation from thoron in indoor air at a distance of about 1 m from interior walls was fairly homogeneous and averaged ~200 Bq m -3 . Most concerning, from a human health perspective, were the high thoron concentrations of up to 884 Bq m -3 in sleeping areas near mud walls. The average annual thoron radiation dose to inhabitants of mud houses was estimated based on 13 hours of daily occupancy, including daily activities and sleeping. The estimated average thoron inhalation dose of 27.1 mSv a -1 during sleeping hours near mud surfaces accounts for nearly 75% of the total estimated radon and thoron inhalation dose of 37.4 mSv a -1 from indoor mud house air. Our conservative annual radiation dose estimates do not include subsequent radiation from inhaled metallic progeny of thoron. Our data demonstrate a significant human health risk from radiation exposure and a critical need for remediation in traditional northern Vietnamese mud house dwellings.

58 GEOSCIENCES↗

Radiation dose from cigarette tobacco

The radioactivity in tobacco leaves collected from 15 different regions of Greece before cigarette production was studied in order to estimate the effective dose from cigarette tobacco due to the naturally occurring primordial radionuclides, such as {sup 226}Ra and {sup 210}Pb of the uranium series and {sup 228}Ra of the thorium series and/or man-made produced radionuclides, such as {sup 137}Cs of Chernobyl origin. Gamma-ray spectrometry was applied using Ge planar and coaxial type detectors of high resolution and high efficiency. It was concluded that the annual effective dose due to inhalation for adults (smokers) for {sup 226}Ra varied from 42.5 to 178.6 {mu}Sv y{sup -1} (average 79.7 {mu}Sv y{sup -1}), while for {sup 228}Ra from 19.3 to 116.0 {mu}Sv y{sup -1} (average 67.1 {mu}Sv y{sup -1}) and for {sup 210}Pb from 47.0 to 134.9 {mu}Sv y{sup -1} (average 104.7 {mu}Sv y{sup -1}), that is the same order of magnitude for each radionuclide. The sum of the effective dose of the three natural radionuclides varied from 151.9 to 401.3 {mu}Sv y{sup -1} (average 251.5 {mu}Sv y{sup -1}). The annual effective dose from {sup 137}Cs of Chernobyl origin was three orders of magnitude lower as it varied from 70.4 to 410.4 nSv y{sup -1} (average 199.3 nSv y{sup -1})

61 RADIATION PROTECTION AND DOSIMETRY↗

The biokinetics of ruthenium in the human body

The biokinetics of ruthenium (Ru) in the human body is of interest due mainly to the potential for occupational or environmental exposure to 106Ru (T1/2 = 373.6 d) and 103Ru (T1/2 = 39.3 d), which typically represent a significant portion of the fission products in a reactor inventory. During reactor operations or nuclear fuel reprocessing these ruthenium isotopes may be present as ruthenium tetroxide (RuO4) vapor, a highly mobile form of ruthenium that has been involved in a number of cases of accidental exposure to 106Ru or 103Ru. This paper summarizes the biokinetic database for ruthenium and proposes a new respiratory model for inhaled RuO4 vapor, a new biokinetic for systemic (absorbed) ruthenium, and material-specific gastrointestinal absorption fractions for ruthenium. The proposed respiratory model for RuO4 differs from the current ICRP model mainly in that it depicts slower clearance of deposited activity from the respiratory tract and lower absorption to blood than depicted in the current ICRP model. The proposed systemic biokinetic model depicts more realistic paths of movement of absorbed ruthenium in the body than the current ICRP model and, in contrast to the present model, a less uniform distribution of systemic activity. Implications of the proposed models with regard to inhalation and ingestion dose coefficients for 106Ru are examined.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Mortality among Tennessee Eastman Corporation (TEC) uranium processing workers, 1943–2019

Background: There are few occupational studies of women exposed to ionizing radiation. During World War II, the Tennessee Eastman Corporation (TEC) operated an electromagnetic field separation facility of 1152 calutrons to obtain enriched uranium (235U) used for the Hiroshima atomic bomb. Thousands of women were involved in these operations. Materials and methods: We report a new study was conducted of 13,951 women and 12,699 men employed at TEC between 1943 and 1947 for at least 90 days. Comprehensive dose reconstruction techniques were used to estimate lung doses from the inhalation of uranium dust based on airborne measurements. Vital status through 2018/2019 was obtained from the National Death Index, Social Security Death Index, Tennessee death records and online public record databases. Analyses included standardized mortality ratios (SMRs) and Cox proportional hazards models. Results: Most workers were hourly (77.7%), white (95.6%), born before 1920 (58.3%), worked in dusty environments (57.0%), and had died (94.9%). Vital status was confirmed for 97.4% of the workers. Women were younger than men when first employed: mean ages 25.0 years and 33.0 years, respectively. The estimated mean absorbed dose to the lung was 32.7 mGy (max 1048 mGy) for women and 18.9 mGy (max 501 mGy) for men. The mean dose to thoracic lymph nodes (TLNs) was 127 mGy. Statistically significant SMRs were observed for lung cancer (SMR 1.25; 95% CI 1.19, 1.31; n = 1654), nonmalignant respiratory diseases (NMRDs) (1.23; 95% CI 1.19, 1.28; n = 2585), and cerebrovascular disease (CeVD) (1.13; 95% CI 1.08, 1.18; n = 1945). For lung cancer, the excess relative rate (ERR) at 100 mGy (95% CI) was 0.01 (–0.10, 0.12; n = 652) among women, and –0.15 (–0.38, 0.07; n = 1002) among men based on a preferred model for men with lung doses <300 mGy. NMRD and non-Hodgkin lymphoma were not associated with estimated absorbed dose to the lung or TLN. Conclusions: There was little evidence that radiation increased the risk of lung cancer, suggesting that inhalation of uranium dust and the associated high-LET alpha particle exposure to lung tissue experienced over a few years is less effective in causing lung cancer than other types of exposures. There was no statistically significant difference in the lung cancer risk estimates between men and women. The elevation of certain causes of death such as CeVD is unexplained and will require additional scrutiny of workplace or lifestyle factors given that radiation is an unlikely contributor since only the lung and lymph nodes received appreciable dose.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

A generic biokinetic model for noble gases with application to radon

The International Commission for Radiological Protection (ICRP) currently uses a dose conversion coefficient to calculate effective dose per unit exposure to radon and its progeny. The coefficient is derived by dividing the detriment associated with unit exposure to radon, as estimated from epidemiological studies, by the detriment per unit effective dose, as estimated mainly from atomic bomb survivor data and animal studies. In a recent statement the ICRP indicated that future guidance on exposure to radon and its progeny will be developed in the same way as guidance for any other radionuclide. That is, intake of radon and progeny will be limited on the basis of effective dose coefficients derived from biokinetic and dosimetric models. This paper proposes a biokinetic model for systemic (absorbed) radon for use in the calculation of dose coefficients for inhaled or ingested radon. The model is based largely on physical laws governing transfer of a non-reactive and soluble gas between materials. Model predictions are shown to be consistent with results of controlled studies of the fate of internally deposited radon in human subjects.

radon progeny effective dose biokinetic model↗

Effects of tumor motion in GRID therapy

Clinical and biological evidence suggest that the success of GRID therapy in debulking large tumors depends on the high peak-to-valley contrast in the dose distribution. In this study, we show that the peaks and valleys can be significantly blurred out by respiration-induced tumor motion, possibly affecting the clinical outcome. Using a kernel-based Monte Carlo dose engine that incorporates phantom motion, we calculate the dose distributions for a GRID with hexagonally arranged holes. The holes have a diameter of 1.3 cm and a minimum center-to-center separation of 2.1 cm (projected at the isocenter). The phantom moves either in the u{sub ||} direction, which is parallel to a line joining any two nearest neighbors, or in the perpendicular u{sub perpendicular} direction. The displacement-time waveform is modeled with a cos{sup n} function, with n assigned 1 for symmetric motion, or 6 to simulate a large inhale-exhale asymmetry. Dose calculations are performed on a water phantom for a 6 MV x-ray beam. Near d{sub max}, the static valley dose is 0.12D{sub 0}, where D{sub 0} is the peak static dose. For motion in the u{sub ||} direction, the peak and valley doses vary periodically with the amplitude of motion a and the transverse dose profiles are maximally flat near a=0.8 cm and a=1.9 cm. For the cos waveform, the minimum peak dose (D{sub p{sub m{sub i{sub n}}}}) is 0.67D{sub 0} and the maximum valley dose (D{sub v{sub m{sub a{sub x}}}}) is 0.60D{sub 0}. Less dose blurring is seen with the cos{sup 6} waveform, with D{sub p{sub m{sub i{sub n}}}}=0.77D{sub 0} and D{sub v{sub m{sub a{sub x}}}}=0.45D{sub 0}. For motion in the u{sub perpendicular} direction, the maximum flattening of dose profiles occurs at a=1.5 cm. GRIDs with smaller hole separations produce similar blurring at proportionally smaller amplitudes. The reported clinical response data from GRID therapy seem to indicate that mobile tumors, such as those in the thorax and abdomen, respond worse to GRID treatments than stationary tumors, such as those in the head and neck. To establish a stronger correlation between clinical response and tumor motion, and possibly improve the clinical response rates, it is recommended that prospective GRID therapy trials be conducted with motion compensation strategies, such as respiratory gating.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Radiological Characterization of Selected Thermal Centres Based on Indoor Radon Dosimetry - 17507

In countries with long historical tradition in thermal water therapy and with several mineral-medicinal thermal sources, workplaces within thermal centers may be a source of radon exposure which may be intensified if these are located in regions of high level of natural radiation. According to the EU Directive 96/29/Euratom (repealed by the Directive 2013/59/EURATOM) each Member State shall identify, by means of survey or any other adequate mean, the work activities where a significant increase in the exposure from natural radiation sources may occur, including thermal centers where the exposure to thoron/radon daughters or gamma radiation may occur. The purpose of this work was to perform a radiological characterization of selected thermal centers based on indoor dosimetry. The effective doses received by workers due to radon inhalation were estimated and gamma dose rates were measured through continuous periods. The radon risk for indoor exposure was assessed on a probabilistic basis both on thermal centers and workers' dwellings. Radon levels within the thermal centers ranged from 73 to 4335 Bq/m{sup 3} and the values within the workers dwellings are of the same order of magnitude, 68-4051 Bq/m{sup 3}. Approximately 66 % of indoor radon concentration values are above the maximum EU reference (300 Bq/m{sup 3}) and 94 % of the effective dose is higher than 1 mSv/year. In some situations, radon levels at residential environments are much higher than at workplaces and effective doses are higher than 6 mSv/year, both at residential and work environments. (authors)

61 RADIATION PROTECTION AND DOSIMETRY↗

Development of a military-specific mesh-type computational phantom library and its application to internal dosimetry and in-field radiological triage screening

Estimates of organ-absorbed and committed doses to individuals exposed to radioactive materials via acute inhalation often rely on internal dose coefficients and detector responses from reference human computational models. To achieve more accurate dose assessments to United States Armed Forces service members exposed in-field, computational models with varying morphometric parameters representative of this population are necessary. The International Commission on Radiological Protection (ICRP) Publication 145 provides detailed mesh reference computational phantoms (MRCPs) for adult males and females, with morphometric parameters matched to the 50th percentile. Previously, these phantoms were 2D and 3D scaled to match desired height, mass, and secondary anthropomorphic parameters in the creation of the University of Florida / Memorial Sloan Kettering (UF/MSK) computational phantom library. To achieve body fat percentage targets required for accession into the US Armed Forces, muscle and fat volumes were adjusted accordingly, thus, creating the UF/Department of Defence computational phantom library presented in this study. A comprehensive library of mesh-type computational human phantoms was created, including 57 adult males and 49 adult females with morphometric parameters aligned with United States Armed Forces service members. Phantoms were restricted to a body mass index between 19 and 27.5, with body fat percentages below 26% for males and 36% for females. Specific absorbed fractions were computed for selected source and target combinations, demonstrating how variations in height and body mass influence energy absorption in target regions relative to the ICRP MRCPs. Radiation detector responses were also computed, revealing that higher body masses resulted in decreased registered counts in the detection volume. These findings highlight the importance of incorporating morphometric variability in computational phantoms to achieve more accurate dose assessments and radiation detection responses for United States Armed Forces service members who inhale radioactive materials in-field.

computational phantoms↗