Search NASA⌕ Search

SEARCH · Search NASA

Results for “Installation Testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Enhancing Thomson scattering polychromator performance with multi-pass spectral filters

In photon-deficient, noncollective Thomson scattering diagnostics, filter polychromators are typically employed in the spectral analysis of Thomson-scattered signals to achieve acceptable signal-to-noise performance. Currently, the most common polychromator filter configuration employs a set of single-passband optical filters that define individual spectral channels. Here, we introduce a new spectral analysis method for Thomson scattering based on spectral filters with multiple passbands, referred to as Thomson scattering spectral multiplexing. Implementing multi-bandpass spectral filters on polychromators increases the achievable range of electron temperature measurement for a given number of filters employed. In addition, Thomson scattering spectral multiplexing reduces systematic measurement uncertainty, with fewer required spectral channels, thereby decreasing light loss from reduced optical element interactions. A multi-bandpass filter set, optimized by a genetic algorithm, has been successfully installed and tested on the Helically Symmetric eXperiment (HSX), demonstrating the benefits of the Thomson scattering spectral multiplexing method.

Instruments & Instrumentation↗

A Short-Lived Isotope Counting System (SLICS) to measure reaction cross sections producing light, beta-decaying nuclei on OMEGA

A new activation detector optimized for short-lived isotopes was designed, installed, and tested on OMEGA. The Short-Lived Isotope Counting System (SLICS) can be positioned as close as 35 cm from the OMEGA target chamber center in a ten-inch-manipulator. Stable target samples can be mounted on the front end of the detector assembly to undergo triton-, deuteron-, or neutron-induced reactions that produce short-lived reaction products that beta decay. The emitted betas are detected in a phoswich configuration to eliminate the gamma background. The detector is optimized for isotopes with half-lives from 150 ms to 20 s, filling a gap in OMEGA’s current activation detectors for isotopes with half-lives >5 min. In a pilot study, SLICS achieved an efficiency of 24.5% ± 2.0% for counting 8Li, with a total of 505.8 ± 4.4 qualifying events. Using the existing triton laser-ion acceleration platform on OMEGA, this detector can be used to measure rarely studied tritium-induced reactions on light nuclei with an estimated uncertainty of 12%. As a result, the design of the detector and its performance during a first experiment employing deuterium as a surrogate will be discussed.

Beta spectrometry↗

Control Algorithms for Dual-wavefront Sensor Single-conjugate Adaptive Optics

High-contrast imaging systems using active control with adaptive optics (AO) are often limited by non-common path (NCP) aberrations that are seen only at the final science image. AO systems employing focal-plane wavefront sensors (FP-WFSs) are able to simultaneously correct NCP aberrations and measure science images, but they typically require a second stage of control that adds system cost and complexity. We present control algorithms to augment AO systems with FP-WFSs within their existing control setup. We demonstrate inter-arm NCP aberration transfer can be mitigated through temporal filtering, present frequency- and time-domain validation of controller stability and performance, and discuss the optimality of the chosen controllers. This work will enable the development, testing, and installation of FP-WFS technologies for direct imaging of exoplanets.

79 ASTRONOMY AND ASTROPHYSICS↗

A measurement of absolute efficiency of the ARAPUCA photon detector in liquid argon

In the Fall of 2017, two photon detector designs for the Deep Underground Neutrino Experiment (DUNE) Far Detector were installed and tested in the TallBo liquid argon (LAr) cryostat at the Proton Assembly (PAB) facility, Fermilab. The designs include two light bars developed at Indiana University and a photon detector based on the ARAPUCA light trap engineered by Colorado State University and Fermilab. The performance of these devices is determined by analyzing 8 weeks of cosmic ray data. The current paper focuses solely on the ARAPUCA device as the performance of the light bars will be reported separately. The article briefly describes the ARAPUCA concept, the TallBo setup, and focuses on data analysis and results.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Hands-On Computer Science: The Array of Things Experimental Urban Instrument

Chicago's Array of Things (AoT) project is aptly described as a technology experiment or a "smart city" prototype. The concept of such an extensible "instrument" arose within a larger translational research vision applying computer science and engineering research for the multidimensional benefit of people and communities in cities. The AoT project hypothesized that wireless intelligent sensor networks could enable both quantitative social science and urban monitoring while also stimulating youth interest in science and technology. Successful deployment of such sensor networks could provide open data from urban measurements not only in support of diverse research questions-in environmental dynamics, urban architecture, engineering, and social sciences-but also informing community groups and city planners. Further, the AoT project and its successor SAGE project are a computer science and engineering experiment, but its success is inextricably tied to community engagement and experiential education. Simply put, community acceptance is a prerequisite to installing and testing the instrument.

97 MATHEMATICS AND COMPUTING↗

Design and Prototyping of a Novel Toroidal Magnet System for MOLLER Experiment at Jefferson Lab

The Thomas Jefferson National Accelerator Facility (JLab) has designed a unique spectrometer system to measure the weak interaction between electrons. The experiment— Measurement of Lepton-Lepton Electroweak Reaction (MOLLER)—requires leveraging the recent 12 GeV electron beam upgrade and will run in JLab for three years. Focusing the signal for the MOLLER experiment requires five water-cooled toroidal magnets, each with unique geometry and with 7-fold symmetry. The five magnets operate in a vacuum and provide the magnetic field required to separate the incident beam electrons scattered from the target electrons (Møller scattering) and protons (elastic e-p scattering) in a liquid hydrogen target. The conceptual design was developed by the MOLLER Collaboration and was given to JLab in the form of amp turns and physical location, with additional physics requirements. This article presents prototyping of the coils and magnet support system and discusses the lessons learned during the process along with the plans for full magnet testing and installation. The JLab Magnet Group along with the MOLLER Collaboration developed the specification document that includes keep out zones to design the set of magnets. JLab contracted the design of the first toroid magnet (TM0) of the magnet system to Massachusetts Institute of Technology. The other four toroid magnets (TM1 through TM4) have been designed by JLab and are in the process of fabrication and assembly. Prototype coils of TM1-TM4 were fabricated by Everson-Tesla Incorporated, PA (USA). Finally, this article presents the unique challenges of the design, alignment, high current density, operating range, high radiation dose, and vacuum environment.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Modifications to the JET Shattered Pellet Injector to Optimize Disruption Mitigation Experiments for Supporting ITER’s DMS Design

Shattered pellet injection (SPI) experiments on Joint European Torus (JET) are an important element in determining the physics basis for mitigating disruptions in ITER. Here, the initial design of the JET SPI system included three barrels to produce pellets with diameters of 4.5, 8.1, and 12.5 mm. The variability of the pellet speed by operating with and without a mechanical punch was limited and led to poor pellet integrity, so the mechanical punch was removed. Fragment size distribution is a function of pellet speed and the desire to change the resulting fragment size distribution was not originally a requirement. After the first set of SPI experiments on JET, different pellet sizes were considered to enable dual injection experiments with identical pellet diameters. It was also determined that speed control is necessary to improve experimental repeatability and to determine how the fragment size distribution impacts mitigation performance. Two barrels were fabricated to form pellets of 10 mm diameter and a third to form an 8.1 mm diameter pellet. New propellant valves were also fabricated and characterized to improve repeatability and overall performance. To have fine control of pellet speed, inserts to reduce the breech volume were fabricated and installed. Laboratory testing was conducted to ensure pellet release and provide a comparison of propellant gas delivered versus pellet speeds for a range of pellet types and mixtures. This article will also discuss how lessons learned from the JET SPI modifications can be applied to other SPI systems, such as the ITER SPI system, as controlling pellet release with the least amount of propellant gas is essential for optimal SPI effectiveness.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

CFD-Enhanced Calibration of a Multihole Probe for Small Uncrewed Aircraft Systems

A robust calibration method with a 9-hole probe (9HP) for inertial wind vector measurements from a small uncrewed aircraft system (sUAS) is presented. Calibration accuracy is improved by using computational fluid dynamics (CFD) to estimate corrections, such as those for test section blockage, that are generally applied in wind tunnel testing. A method for estimating experimental bias is presented to account for flow variations over the pressure taps as the 9HP is repositioned in the test section. Installation effects from flow over the airframe and upwash produced by the wings are estimated from CFD simulations of the entire airframe at the expected cruise speed. An initial CFD analysis has demonstrated a quantifiable linear relationship between the measured and actual angle of attack as measured from the relative wind frame. In conclusion, the objective of these additional steps is to increase the accuracy of 9HP calibration.

54 ENVIRONMENTAL SCIENCES↗

RFA Measurement of E-Cloud Generation Process at Fermilab Main Injector

Fermilab aims to provide greater beam power for the neutrino physics program. As the beam power increases, the unwanted production of secondary electrons in the beam pipe, known as ‘electron cloud’ or ‘E-cloud’ may become disruptive to high intensity operation. Instrumentation has been deployed in the Fermilab Main Injector (MI) to study E-cloud. One of these is a Retard Field Analyzer (RFA) that can be used to directly measure E-cloud generation at the location of the instrument. Studies of the dependence of E-cloud on beam intensity and bunch length have been carried out. The experimental results are compared to POSINST simulations. These simulations are guided by measurements from a Secondary Electron Yield (SEY) test stand installed in the MI to measure the SEY of materials such as the beam pipe stainless steel. The SEY has a strong influence on the E-cloud density. Results of these comprehensive studies comparing the RFA data with realistic MI simulations will be presented.

43 PARTICLE ACCELERATORS↗

SRF Cavity Instability Detection with Machine Learning at CEBAF

During the operation of CEBAF, one or more unstable superconducting radio-frequency (SRF) cavities often cause beam loss trips while the unstable cavities themselves do not necessarily trip off. Identifying an unstable cavity out of the hundreds of cavities installed at CEBAF is difficult and time-consuming. The present RF controls for the legacy cavities report at only 1 Hz, which is too slow to detect fast transient instabilities. A fast data acquisition system for the legacy SRF cavities is being developed which samples and reports at 5 kHz to allow for detection of transients. A prototype chassis has been installed and tested in CEBAF. An autoencoder based machine learning model is being developed to identify anomalous SRF cavity behavior. The model is presently being trained on the slow (1 Hz) data that is currently available, and a separate model will be developed and trained using the fast (5 kHz) DAQ data once it becomes available. This paper will discuss the present status of the new fast data acquisition system and results of testing the prototype chassis. This paper will also detail the initial performance metrics of the autoencoder model.

Carpenter, A.↗

Historical Context and Perspective on Allowable Stresses and Design Parameters in ASME Section III, Division 5, Subsection HB, Subpart B

In the 1970s, the U.S. Nuclear Regulatory Commission (NRC) issued Regulatory Guide (RG) 1.87 (Rev 1, June 1975) to provide interim licensing guidelines to aid applicants in implementing the 10 CFR Part 50 requirements with respect to American Society of Mechanical Engineers (ASME) Boiler Pressure and Vessel Code (BPVC) Class 1 components operating at elevated temperatures for high-temperature gas-cooled reactors, liquid-metal fast-breeder reactors, and gas-cooled fast-breeder reactors. RG 1.87 referenced ASME Code Case 1592 for materials and design and Code Cases 1593, 1594, 1595, and 1596 for fabrication and installation, examination, testing, and overpressure protection, respectively.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Characterization of the Redesigned Extended MITL for HERMES III

Modeling and simulation of the legacy HERMES III Magnetically Insulated Transmission Line (MITL) has been performed using EMPHASIS, an unstructured time-domain electromagnetic (UTDEM) particle-in-cell (PIC) simulation software. This design when used lost roughly half of its current before the pulse reached the load. The cause of the current loss in the MITL was found to be the vacuum impedance changes along the MITL. The MITL was then redesigned to maintain constant impedance and simulated in EMPHASIS once again. Following predicting simulation results, the new MITL was then built, installed, and tested, showing minimal current loss and good agreement with simulation and theoretical results, all of which are reported here. Additionally, an analysis of experimental voltage calculation techniques using cathode and anode currents is performed and compared to simulation results.

97 MATHEMATICS AND COMPUTING↗

Evaluation of the Generation-2 Dechlorination Apparatus for Treating Salt Wastes

This document satisfies the requirements for two milestones, i.e., M2FT-21PN030103021 and M3FT-21PN030103026, which are described in detail below. Also, details for the work package at the Pacific Northwest National Laboratory (PNNL) are provided below. The goal of this milestone was to demonstrate the generation-2 dechlorination apparatus (G2DA) for removing Cl from chloride-based electrochemical salt simulants. The two salts chosen for this initial study were KCl to simulate a component from the eutectic salt (LiCl is harder to detect with analytical instruments) and CsCl to simulate a fission product chloride that might be present in these types of waste streams. The overall scope of this work included receiving, installing, and testing the G2DA. This new system was designed to address several shortcomings identified with the generation-1 apparatus (G1DA), which are described in detail within this document. The G2DA was designed to address all of these shortcomings. The studies presented in here show that the G2DA worked as intended and will help provide scaled-up batches for additional testing at Argonne National Laboratory.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

MCNP ® Code Version 6.3.0 Build Guide

This is a build guide for the MCNP ® code, version 6.3.0, that expands upon the README.md included with the source code. It covers compilers, dependencies, building, testing, and installing the code in one of its supported configurations.

97 MATHEMATICS AND COMPUTING↗

Strain measurements of Nb₃Sn coils with optical fibers

The HL-LHC at CERN will be using new superconducting quadrupole magnets (MQXFA) made of Nb₃Sn that are in the process of being tested before installation in the LHC tunnel. MQXFA07 and MQXFA08 magnets failed because of high stress developed at the coil wedge/end spacer interface, where the Nb₃Sn coil, the stainless-steel end parts, and copper wedges exhibit different strain responses. Interrogating a cut piece of coil QXFP06 with optical fibers, we expect to get a better understanding of the stress response of the coil wedge/end spacer interface.

Nisa, Kuvvetn↗

Design and Prototyping of a Novel Toroid Magnet System for the MOLLER Experiment at Jefferson Lab

The Thomas Jefferson National Accelerator Facility (JLab) has designed a unique spectrometer system to measure the weak interaction between electrons. The experiment ?Measurement of Lepton-Lepton Electroweak Reaction? (MOLLER) requires leveraging the recent 12 GeV electron beam upgrade and will run in JLab for 3 years. Focusing the signal for the MOLLER experiment requires five water-cooled toroidal magnets, each with unique geometry and with 7-fold symmetry. This system of magnets provides the magnetic field required to separate the incident beam electrons scattered from the target electrons (Møller scattering) and protons (elastic e-p scattering) in a liquid hydrogen target. The conceptual design was developed by the MOLLER collaboration and was given to JLab in the form of amp turns and physical location, with additional physics requirements. This paper presents prototyping of the coils and magnet support system and discusses the lessons learned during the process along with the plans for full magnet testing and installation. The JLab Magnet Group along with the MOLLER collaboration developed the specification document that includes keep out zones to design the set of magnets. JLab contracted the design of the first toroid magnet in the magnet (TM0) to Massachusetts Institute of Technology. The other four toroid magnets (TM1 through TM4) have been designed by JLab and are in the process of fabrication and assembly. Prototype coils of TM1-TM4 have been fabricated by Everson-Tesla Incorporated, PA (USA). The manuscript presents the unique challenges of the design, alignment, high current density, operating range, high radiation dose, and vacuum environment.

Kashy, David↗

SRF Cavity Instability Detection with Machine Learning at CEBAF

During the operation of CEBAF, one or more unstable superconducting radio-frequency (SRF) cavities often cause beam loss trips while the unstable cavities themselves do not necessarily trip off. Identifying an unstable cavity out of the hundreds of cavities installed at CEBAF is difficult and time-consuming. The present RF controls for the legacy cavities report at only 1 Hz, which is too slow to detect fast transient instabilities. A fast data acquisition system for the legacy SRF cavities is being developed which samples and reports at 5 kHz to allow for detection of transients. A prototype chassis has been installed and tested in CEBAF. An autoencoder based machine learning model is being developed to identify anomalous SRF cavity behavior. The model is presently being trained on the slow (1 Hz) data that is currently available, and a separate model will be developed and trained using the fast (5 kHz) DAQ data once it becomes available. This paper will discuss the present status of the new fast data acquisition system and results of testing the prototype chassis. This paper will also detail the initial performance metrics of the autoencoder model.

Carpenter, A.↗