Electromagnetic Analysis of ITER Electron Cyclotron Emission Model
The ITER electron cyclotron emission (ECE) diagnostic system is located at diagnostics shielding module 2 (DSM2), equatorial port 9 (EP9), to measure electron temperature profile and electron temperature fluctuations, and also assess nonthermal electron distributions via the oblique view. Therefore, ECE has both radial and oblique views with two hot sources for calibration and two couples of mirrors for two different optical views. It shall receive that the large electromagnetic (EM) loads up to 100-MN/m3 force density due to the eddy currents on the copper mirrors generated by the short transient plasma disruption. The simplified EM analysis model using magnetic field ( B ) data and flux variations (dB/dt) method based on the worst case of plasma disruption, MD_DW_EXP16MS_CATIII, has been developed to calculate the force and moments for each ECE component and support structure for EP9 DSM2 Bay2 and Bay3. The B and dB/dt methods use the constant B and dB/dt assumed for each local bay space, but the real B and dB/dt are basically varied along the radial direction of each bay. The complex global model with the local ECE components and support structure using Maxwell transient has been developed to do EM analysis to compare the results of the B and dB/dt models. The volumetric EM force density of the whole ECE components and support structure can be used for the subsequent structural analysis. In conclusion, combined with the thermal and nuclear loads and seismic and initial loads, the ECE integration analysis can be finalized for the operation case.