Search NASA⌕ Search

SEARCH · Search NASA

Results for “Intense exercise”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Exercise and osteoporosis: Methodological and practical considerations

Physical activity may have important implications for enhancing bone density prior to the initiation of space flight, for preserving bone density during zero gravity, and for rehabilitating the skeleton upon return to Earth. Nevertheless, the beneficial effects of exercise upon the skeleton have not been proven by controlled trials and no consensus exists regarding the type, duration, and intensity of exercise necessary to make significant alterations to the skeleton. The following sections review our current understanding of exercise and osteoporosis, examine some of the methodological shortcomings of these investigations, and make research recommendations for future clinical trials.

Block, Jon E.↗

Exercise during long term exposure to space: Value of exercise during space exploration

There appear to be two general physiological reasons why exercise will be beneficial to space travelers who will experience a weightless and isolated environment for many months or a few years: (1) to alleviate or prevent tissue atrophy (principally bone and muscle), to maintain cardiovascular function, and to prevent deleterious changes in extracellular and cellular fluid volumes and plasma constituents, especially electrolytes; and (2) to maintain whole organism functional physical and physiological status with special reference to neuromuscular coordination (physical skill) and physical fitness (muscle strength and power, flexibility, and aerobic endurance). The latter reason also relates well to the ability of the crew members to resist both general and local fatigue and thus ensure consistent physical performance. Various forms of exercise, performed regularly, could help alleviate boredom and assist the travelers in coping with stress, anxiety, and depression. The type, frequency, duration and intensity of exercise and ways of ensuring that crew members engage in it are discussed.

Source record↗

Carotid baroreflex regulation of sympathetic nerve activity during dynamic exercise in humans

We sought to determine whether carotid baroreflex (CBR) control of muscle sympathetic nerve activity (MSNA) was altered during dynamic exercise. In five men and three women, 23.8 +/- 0.7 (SE) yr of age, CBR function was evaluated at rest and during 20 min of arm cycling at 50% peak O(2) uptake using 5-s periods of neck pressure and neck suction. From rest to steady-state arm cycling, mean arterial pressure (MAP) was significantly increased from 90.0 +/- 2.7 to 118.7 +/- 3.6 mmHg and MSNA burst frequency (microneurography at the peroneal nerve) was elevated by 51 +/- 14% (P < 0.01). However, despite the marked increases in MAP and MSNA during exercise, CBR-Delta%MSNA responses elicited by the application of various levels of neck pressure and neck suction ranging from +45 to -80 Torr were not significantly different from those at rest. Furthermore, estimated baroreflex sensitivity for the control of MSNA at rest was the same as during exercise (P = 0.74) across the range of neck chamber pressures. Thus CBR control of sympathetic nerve activity appears to be preserved during moderate-intensity dynamic exercise.

Non-NASA Center↗

NASA Exercise Physiology and Countermeasures Project Overview

Efficient exercise countermeasures are necessary to offset or minimize spaceflight-induced deconditioning and to maximize crew performance of mission tasks. These countermeasure protocols should use the fewest crew and vehicle resources. NASA s Exercise Physiology and Countermeasures (ExPC) Project works to identify, collect, interpret, and summarize evidence that results in effective exercise countermeasure protocols which protect crew health and performance during International Space Station (ISS) and future exploration-class missions. The ExPC and NASA s Human Research Program are sponsoring multiple studies to evaluate and improve the efficacy of spaceflight exercise countermeasures. First, the Project will measure maximal aerobic capacity (VO2max) during cycle ergometry before, during, and after ISS missions. Second, the Project is sponsoring an evaluation of a new prototype harness that offers improved comfort and increased loading during treadmill operations. Third, the Functional Tasks Test protocol will map performance of anticipated lunar mission tasks with physiologic systems before and after short and long-duration spaceflight, to target system contributions and the tailoring of exercise protocols to maximize performance. In addition to these studies that are actively enrolling crewmember participants, the ExPC is planning new studies that include an evaluation of a higher-intensity/lower-volume exercise countermeasure protocol aboard the ISS using the Advanced Resistive Exercise Device and second-generation treadmill, studies that evaluate bone loading during spaceflight exercise, and ground-based studies that focus on fitness for duty standards required to complete lunar mission tasks and for which exercise protocols need to protect. Summaries of these current and future studies and strategies will be provided to international colleagues for knowledge sharing and possible collaboration.

Loerch, Linda↗

Ambulation Increases Decompression Sickness in Altitude Exposure

INTRODUCTION - Exercise accelerates inert gas elimination during oxygen breathing prior to decompression (prebreathe), but may also promote bubble formation and increase the risk of decompression sickness (DCS). The timing, pattern and intensity of exercise are likely critical to the net effect. The NASA Prebreathe Reduction Program (PRP) combined oxygen prebreathe and exercise preceding a 4.3 psi exposure in non-ambulatory subjects (a microgravity analog) to produce two protocols now used by astronauts preparing for extravehicular activity (CEVIS and ISLE). Additional work is required to investigate whether exercise normal to 1 G environments increases the risk of DCS over microgravity simulation. METHODS - The CEVIS protocol was replicated with one exception. Our subjects completed controlled ambulation (walking in place with fixed cadence and step height) during both preflight and at 4.3 psi instead of remaining non-ambulatory throughout. Decompression stress was graded with aural Doppler (Spencer 0-IV scale). Two-dimensional echocardiographic imaging was used to look for left heart gas emboli (the presence of which prompted test termination). Venous blood was collected at three points to correlate Doppler measures of decompression stress with microparticle (cell fragment) accumulation. Fisher Exact Tests compared test and control groups. Trial suspension would occur when DCS risk >15% or grade IV venous gas emboli (VGE) risk >20% (at 70% confidence). RESULTS - Eleven person-trials were completed (9 male, 2 female) when DCS prompted suspension. DCS was greater than in CEVIS trials (3/11 [27%] vs. 0/45 [0%], respectively, p=0.03). Statistical significance was not reached for peak grade IV VGE (2/11 [18%] vs. 3/45 [7%], p=0.149) or cumulative grade IV VGE observations per subject-trial (8/128 [6%] vs. 26/630 [4%], p=0.151). Microparticle data were collected for 5/11 trials (3 with DCS outcomes), with widely varying patterns that could not be resolved statistically. CONCLUSION - We did find that that ambulation increases decompression stress. Additional trials would improve the statistical power to assess differences in VGE and to evaluate the relationship between decompression stress and microparticles.

Conkin, Johnny↗

Resistance exercise as a countermeasure to disuse-induced bone loss

During spaceflight, skeletal unloading results in loss of bone mineral density (BMD). This occurs primarily in the spine and lower body regions. This loss of skeletal mass could prove hazardous to astronauts on flights of long duration. In this study, intense resistance exercise was used to test whether a training regimen would prevent the loss of BMD that accompanies disuse. Nine subjects (5 men, 4 women) participated in a supine maximal resistance exercise training program during 17 wk of horizontal bed rest. These subjects were compared with 18 control subjects (13 men, 5 women) who followed the same bed rest protocol without exercise. Determination of treatment effect was based on measures of BMD, bone metabolism markers, and calcium balance obtained before, during, and after bed rest. Exercisers and controls had significantly (P < 0.05) different means, represented by the respective following percent changes: lumbar spine BMD, +3% vs. -1%; total hip BMD, +1% vs. -3%; calcaneus BMD, +1% vs. -9%; pelvis BMD, -0.5% vs. -3%; total body BMD, 0% vs. -1%; bone-specific alkaline phosphatase, +64% vs. 0%; alkaline phosphatase, +31% vs. +5%; osteocalcin, +43% vs. +10%; 1,25 dihydroxyvitamin D, +12% vs. -15%; parathyroid hormone intact molecule, +18% vs. -25%; and serum and ionized calcium, -1% vs. +1%. The difference in net calcium balance was also significant (+21 mg/day vs. -199 mg/day, exercise vs. control). The gastrocnemius and soleus muscle volumes decreased significantly in the exercise group, but the loss was significantly less than observed in the control group. The results indicate that resistance exercise had a positive treatment effect and thus might be useful as a countermeasure to prevent the deleterious skeletal changes associated with long-duration spaceflight.

Clinical Trial↗

Bluetooth Heart Rate Monitors For Spaceflight

Heart rate monitoring is required for crewmembers during exercise aboard the International Space Station (ISS) and will be for future exploration missions. The cardiovascular system must be sufficiently stressed throughout a mission to maintain the ability to perform nominal and contingency/emergency tasks. High quality heart rate data are required to accurately determine the intensity of exercise performed by the crewmembers and show maintenance of VO2max. The quality of the data collected on ISS is subject to multiple limitations and is insufficient to meet current requirements. PURPOSE: To evaluate the performance of commercially available Bluetooth heart rate monitors (BT_HRM) and their ability to provide high quality heart rate data to monitor crew health aboard the ISS and during future exploration missions. METHODS: Nineteen subjects completed 30 data collection sessions of various intensities on the treadmill and/or cycle. Subjects wore several BT_HRM technologies for each testing session. One electrode-based chest strap (CS) was worn, while one or more optical sensors (OS) were worn. Subjects were instrumented with a 12-lead ECG to compare the heart rate data from the Bluetooth sensors. Each BT_HRM data set was time matched to the ECG data and a +/-5bpm threshold was applied to the difference between the 2 data sets. Percent error was calculated based on the number of data points outside the threshold and the total number of data points. RESULTS: The electrode-based chest straps performed better than the optical sensors. The best performing CS was CS1 (1.6% error), followed by CS4 (3.3% error), CS3 (6.4% error), and CS2 (9.2% error). The OS resulted in 10.4% error for OS1 and 14.9% error for OS2. CONCLUSIONS: The highest quality data came from CS1, but unfortunately it has been discontinued by the manufacturer. The optical sensors have not been ruled out for use, but more investigation is needed to determine how to obtain the best quality data. CS2 will be used in an ISS Bluetooth validation study, because it simultaneously transmits magnetic pulse that is integrated with existing exercise hardware on ISS. The simultaneous data streams allow for beat-to-beat comparison between the current ISS standard and CS2. Upon Bluetooth validation aboard ISS, the research team will down select a new BT_HRM for operational use.

Buxton, R. E.↗

Exercise Within LBNP to Produce Artificial Gravity

Integrated physiologic countermeasures are needed to maintain orthostatic tolerance after spaceflight or bed rest. We hypothesized that supine exercise during LBNP would prevent bed rest-induced loss of orthostatic tolerance by preventing hemoconcentration. In a study conducted jointly with NASA Johnson Space Center and the University of Texas Medical Branch, Galveston, TX, fifteen male subjects underwent 5 days of 6 deg head-down bed rest: 5 control subjects did not exercise, and 10 performed 30 min/day of supine interval treadmill exercise at intensities up to 90% VO(sub 2peak). We will undertake two 14 day bed-rest studies (6 deg head-down tilt bed rest, HDT) to investigate the mechanism of action and efficacy of our partial vacuum exerciser concept. These 14 day bed rest studies were chosen to simulate current microgravity exposures for Space Shuttle crew members.

Hargens, Alan R.↗

Bluetooth(Registered Trademark) Heart Rate Monitors for Spaceflight

Heart rate monitoring is required during exercise for crewmembers aboard the International Space Station (ISS) and will be for future exploration missions. The cardiovascular system must be sufficiently stressed throughout a mission to maintain the ability to perform nominal and contingency/emergency tasks. High quality heart rate data is required to accurately determine the intensity of exercise performed by the crewmembers and show maintenance of VO2max. The quality of the data collected on ISS is subject to multiple limitations and is insufficient to meet current requirements. PURPOSE: To evaluate the performance of commercially available Bluetooth® heart rate monitors (BT_HRM) and their ability to provide high quality heart rate data to monitor crew health on board ISS and during future exploration missions. METHODS: Nineteen subjects completed 30 data collection sessions of various intensities on the treadmill and/or cycle. Subjects wore several BT_HRM technologies for each testing session. One electrode-based chest strap (CS) was worn, while one or more optical sensors (OS) was worn. Subjects were instrumented with a 12-lead ECG to compare the heart rate data from the Bluetooth sensors. Each BT_RHM data set was time matched to the ECG data and a +/-5bpm threshold was applied to the difference between the two data sets. Percent error was calculated based on the number of data points outside the threshold and the total number of data points. REULTS: The electrode-based chest straps performed better than the optical sensors. The best performing CS was CS1 (1.6%error), followed by CS4 (3.3%error), CS3 (6.4%error), and CS2 (9.2%error). The OS resulted in 10.4% error for OS1 and 14.9% error for OS2. CONCLUSIONS: The highest quality data came from CS1, unfortunately it has been discontinued by the manufacturer. The optical sensors have not been ruled out for use, but more investigation is needed to determine how to get the best quality data. CS2 will be used in an ISS Bluetooth validation study, because it simultaneously transmits Magnetic Pulse which is integrated with existing exercise hardware on ISS. The simultaneous data streams allow for beat to beat comparison between the current ISS standard and CS2.Upon Bluetooth(Registered Trademark) validation aboard ISS, down select of a new BT_HRM for operational use will be made.

Buxton, Roxanne E.↗

Sweat Rates During Continuous and Interval Aerobic Exercise: Implications for NASA Multipurpose Crew Vehicle (MPCV) Missions

Aerobic deconditioning is one of the effects spaceflight. Impaired crewmember performance due to loss of aerobic conditioning is one of the risks identified for mitigation by the NASA Human Research Program. Missions longer than 8 days will involve exercise countermeasures including those aimed at preventing the loss of aerobic capacity. The NASA Multipurpose Crew Vehicle (MPCV) will be NASA's centerpiece architecture for human space exploration beyond low Earth orbit. Aerobic exercise within the small habitable volume of the MPCV is expected to challenge the ability of the environmental control systems, especially in terms of moisture control. Exercising humans contribute moisture to the environment by increased respiratory rate (exhaling air at 100% humidity) and sweat. Current acceptable values are based on theoretical models that rely on an "average" crew member working continuously at 75% of their aerobic capacity (Human Systems Integration Requirements Document). Evidence suggests that high intensity interval exercise for much shorter durations are equally effective or better in building and maintaining aerobic capacity. This investigation will examine sweat and respiratory rates for operationally relevant continuous and interval aerobic exercise protocols using a variety of different individuals. The results will directly inform what types of aerobic exercise countermeasures will be feasible to prescribe for crewmembers aboard the MPCV.

Ryder, Jeffrey W.↗

Skeletal muscle fiber type composition and performance during repeated bouts of maximal, concentric contractions

Force output and fatigue and recovery patterns were studied during intermittent short-term exercise. 27 men performed three bouts of 30 maximal unilateral knee extensions on 2 different occasions. Blood flow was maintained or occluded during recovery periods (60 s). Blood flow was restricted by inflating a pneumatic cuff placed around the proximal thigh. Muscle biopsies from vastus lateralis were analyzed for identification of fast twitch (FT) and slow twitch (ST) fibers and relative FT area. Peak torque decreased during each bout of exercise and more when blood flow was restricted during recovery. Initial peak torque (IPT) and average peak torque (APT) decreased over the three exercise bouts. This response was 3 fold greater without than with blood flow during recovery. IPT and APT decreased more in individuals with mainly FT fibers than in those with mainly ST fibers. It is suggested that performance during repeated bouts of maximal concentric contractions differs between individuals with different fiber type composition. Specifically, in high intensity, intermittent exercise with emphasis on anaerobic energy release a high FT composition may not necessarily be advantageous for performance.

Muscle Contraction↗

Resistance exercise training and the orthostatic response

Resistance exercise has been suggested to increase blood volume, increase the sensitivity of the carotid baroreceptor cardiac reflex response (BARO), and decrease leg compliance, all factors that are expected to improve orthostatic tolerance. To further test these hypotheses, cardiovascular responses to standing and to pre-syncopal limited lower body negative pressure (LBNP) were measured in two groups of sedentary men before and after a 12-week period of either exercise (n = 10) or no exercise (control, n = 9). Resistance exercise training consisted of nine isotonic exercises, four sets of each, 3 days per week, stressing all major muscle groups. After exercise training, leg muscle volumes increased (P < 0.05) by 4-14%, lean body mass increased (P = 0.00) by 2.0 (0.5) kg, leg compliance and BARO were not significantly altered, and the maximal LBNP tolerated without pre-syncope was not significantly different. Supine resting heart rate was reduced (P = 0.03) without attenuating the heart rate or blood pressure responses during the stand test or LBNP. Also, blood volume (125I and 51Cr) and red cell mass were increased (P < 0.02) by 2.8% and 3.9%, respectively. These findings indicate that intense resistance exercise increases blood volume but does not consistently improve orthostatic tolerance.

NASA Discipline Musculoskeletal↗

Spontaneous running activity in male rats - Effect of age

Variations in the intensity and the patterns of spontaneous running activity in wheel cages were studied in male rats aged 7 weeks to one year. Daily running records were obtained for periods of 12 mo, and 24-hour recordings were made for selected runners in order to study variations in running activity during the day. The data indicate that for rats running over two miles/day, the maximum running intensity can be divided into two groups: a group of high achievers running 8 miles/day; and a group of moderate achievers running 4.8 miles/day. For both groups spontaneous activity reached a maximum after 4-5 weeks. An hourly pattern of running activity during the day was identified in rats of increasing age who averaged 9.0, 4.5, 2.6, and 1.2 miles/day, respectively. Progressive losses were observed in both the speed and the duration of spontaneous running as the rats increased in age, with the intensity of exercise falling below 2 miles/day after 7-8 months of age.

Mondon, C. E.↗

Carbon dioxide and water vapor production at rest and during exercise. A report on data collection for the Crew and Thermal Systems Division

The current environmental control device in the shuttle uses lithium hydroxide (LiOH) filter canisters to remove carbon dioxide (CO2) from the cabin air, requiring several bulky filter canisters that can only be used once and must be changed frequently. To alleviate a stowage problem and decrease launch weight, the Crew and Thermal Systems Division (CTSD) at the NASA Johnson Space Center has been researching a system to be used on future shuttle missions. This system uses two beds of solid amine material to absorb CO2 and water, later desorbing them to space vacuum. In this way the air scrubbing medium is regenerable and reusable. To identify the efficacy of this regenerable CO2 removal system (RCRS), CTSD began investigations in the shuttle mockup. The purpose of this investigation was to support the CTSD program by determining mean levels of carbon dioxide and water vapor production in normal, healthy males and females age-matched with the astronaut corps. Subjects' responses were measured at rest and during exercise at intensity levels equivalent to normal shuttle operation activities. The results were used to assess the adjustments made to RCRS and are reported as a reference for future investigations in shuttle environmental control.

Lee, Stuart M. C.↗

Uncertainty Analysis of Decomposing Polyurethane Foam

Sensitivity/uncertainty analyses are necessary to determine where to allocate resources for improved predictions in support of our nation's nuclear safety mission. Yet, sensitivity/uncertainty analyses are not commonly performed on complex combustion models because the calculations are time consuming, CPU intensive, nontrivial exercises that can lead to deceptive results. To illustrate these ideas, a variety of sensitivity/uncertainty analyses were used to determine the uncertainty associated with thermal decomposition of polyurethane foam exposed to high radiative flux boundary conditions. The polyurethane used in this study is a rigid closed-cell foam used as an encapsulant. Related polyurethane binders such as Estane are used in many energetic materials of interest to the JANNAF community. The complex, finite element foam decomposition model used in this study has 25 input parameters that include chemistry, polymer structure, and thermophysical properties. The response variable was selected as the steady-state decomposition front velocity calculated as the derivative of the decomposition front location versus time. An analytical mean value sensitivity/uncertainty (MV) analysis was used to determine the standard deviation by taking numerical derivatives of the response variable with respect to each of the 25 input parameters. Since the response variable is also a derivative, the standard deviation was essentially determined from a second derivative that was extremely sensitive to numerical noise. To minimize the numerical noise, 50-micrometer element dimensions and approximately 1-msec time steps were required to obtain stable uncertainty results. As an alternative method to determine the uncertainty and sensitivity in the decomposition front velocity, surrogate response surfaces were generated for use with a constrained Latin Hypercube Sampling (LHS) technique. Two surrogate response surfaces were investigated: 1) a linear surrogate response surface (LIN) and 2) a quadratic response surface (QUAD). The LHS techniques do not require derivatives of the response variable and are subsequently relatively insensitive to numerical noise. To compare the LIN and QUAD methods to the MV method, a direct LHS analysis (DLHS) was performed using the full grid and timestep resolved finite element model. The surrogate response models (LIN and QUAD) are shown to give acceptable values of the mean and standard deviation when compared to the fully converged DLHS model.

Hobbs, Michael L.↗

Evaluation of muscle injury using magnetic resonance imaging

The objective of this study was to investigate spin echo T2 relaxation time changes in thigh muscles after intense eccentric exercise in healthy men. Spin echo and calculated T2 relaxation time images of the thighs were obtained on several occasions after exercise of one limb; the contralateral limb served as control. Muscle damage was verified by elevated levels of serum creatine kinase (CK). Thirty percent of the time no exercise effect was discernible on the magnetic resonance (MR) images. In all positive MR images (70%) the semitendinosus muscle was positive, while the biceps femoris, short head, and gracilis muscles were also positive in 50% and 25% of the total cases, respectively. The peak T2 relaxation time and serum CK were correlated (r = 0.94, p<0.01); temporal changes in muscle T2 relaxation time and serum CK were similar, although T2 relaxation time remained positive after serum CK returned to background levels. We conclude that magnetic resonance imaging can serve as a useful tool in the evaluation of eccentric exercise muscle damage by providing a quantitative indicator of damage and its resolution as well as the specific areas and muscles.

NASA Discipline Number 26-10↗

Influence of Exercise Modality on Cerebral-Ocular Hemodynamics and Pressures

Background: Moderate and high intensity aerobic or resistance exercise has clearly identified benefits for cardiac, muscle, and bone health. However, the impact of such exercise - either as a mitigating or an exacerbating factor - on the development of the visual impairment and intracranial pressure syndrome (VIIP) is unknown. Accordingly, our aim was to characterize the effect of an acute bout of resistance (RE), moderate-intensity continuous (CE), and high-intensity interval exercise (IE) during a cephalad fluid shift on cerebral-ocular hemodynamics and pressures. Methods: 10 male subjects (36 plus or minus 9 years) completed 4 testing days in a 15 degree head-down tilt (HDT): (1) assessment of maximum volume of O (sub 2), (2) RE session (4 sets of 12 repetition maximum leg press exercise), (3) CE session (30 minutes of cycling at 60 percent maximum volume of O (sub 2)), and (4) IE session (4 by 4-minute intervals of exercise at 85 percent maximum volume of O (sub 2) with 3-minute active rest periods). During each session, blood flow (Vivid-e, GE Healthcare) in extracranial arteries (common carotid artery, CCA; internal carotid artery, ICA; external carotid artery, ECA and vertebral artery, VA), and mean blood flow velocity in middle cerebral artery (MCA), internal jugular pressure (IJP; VeinPress), and intraocular pressure (IOP; Icare PRO) were measured at rest, at the end of each resistance or interval set, and every 5 minutes during continuous exercise. Translaminar pressure gradient (TLPG) was estimated by subtracting IJP from IOP. Results: There were no differences across days in pre-exercise resting blood flows or pressures. IOP decreased slightly from HDT rest (20.2 plus or minus 2.3 millimeters of mercury) to exercise (RE: 19.2 plus or minus 2.8 millimeters of mercury; CE: 18.9 plus or minus 3.2 millimeters of mercury; IE: 20.1 plus or minus 2.8 millimeters of mercury), while IJP decreased during CE (31.6 plus or minus 9.5 millimeters of mercury) and RE (32.0 plus or minus 8.1 millimeters of mercury), and increased during IE (35.1 plus or minus 9.5 millimeters of mercury) from HDT rest (33.3 plus or minus 6.5 millimeters of mercury). Estimated TLPG was increased during IE only. Compared to RE and CE, IE resulted in the greatest increase in MCA blood flow velocity and extracranial artery blood flow. Conclusions: These preliminary results suggest that high-intensity IE acutely increases cerebral blood flow, IJP, and TLPG. Alterations in TLPG is one mechanism that may contribute to optic nerve sheath edema in astronauts. Accordingly, acutely raising IOP and/or orbital pressure during exercise could optimize cerebral-ocular pressures during spaceflight.

Scott, J.↗

Comparison of different cooling regimes within a shortened liquid cooling/warming garment on physiological and psychological comfort during exercise

The aim of this study was to compare the effectiveness of different cooling regime intensities to maintain physiological and subjective comfort during physical exertion levels comparable to that engaged in during extravehicular activities (EVA) in space. We studied eight subjects (six males, two females) donned in our newly developed physiologically based shortened liquid cooling/warming garment (SLCWG). Rigorous (condition 1) and mild (condition 2) water temperature cooling regimes were compared at physical exertion levels comparable to that performed during EVA to ascertain the effectiveness of a lesser intensity of cooling in maintaining thermal comfort, thus reducing energy consumption in the portable life support system. Exercise intensity was varied across stages of the session. Finger temperature, rectal temperature, and subjective perception of overall body and hand comfort were assessed. Finger temperature was significantly higher in the rigorous cooling condition and showed a consistent increase across exercise stages, likely due to the restriction of heat extraction because of the intensive cold. In the mild cooling condition, finger temperature exhibited an overall decline with cooling, indicating greater heat extraction from the body. Rectal temperature was not significantly different between conditions, and showed a steady increase over exercise stages in both rigorous and mild cooling conditions. Ratings of overall comfort were 30% higher (more positive) and more stable in mild cooling (p<0.001). The mild cooling regime was more effective than rigorous cooling in allowing the process of heat exchange to occur, thus maintaining thermal homeostasis and subjective comfort during physical exertion.

NASA Discipline Life Sciences Technologies↗