Search NASA⌕ Search

SEARCH · Search NASA

Results for “Inverter Controls”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

PRECISE™ PREconfiguring and Controlling Inverter SEt-points: A Solution for Easy Solar Integration

PRECISE™ is a software solution for preconfiguring solar inverter settings. It can be used by utilities and system operators to efficiently process new inverter applications at much less the time and effort, and with greater precision for settings that optimize stability and energy savings. PRECISE has received an R&D 100 award, and has been used to dramatically cut wait times and labor costs for new residential solar installations.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Modbus RTU for Embedded Cyber Secure Inverter Controller

The Modbus communication protocol is a widely adopted communication standard in industrial control systems. This communication protocol is known for being reliable and straightforward to implement while being versatile in terms of its operating parameters while supporting multiple formats over various hardware infrastructures and architectures. Many intelligent devices such as Programmable Logic Controllers (PLCs), Human-Machine Interfaces (HMIs), Internet-of-Things (IoT), and various Operational Technologies (OT) utilize Modbus for their communication systems. These types of systems must communicate with each other through a standardized and central communication process. To support the integration of these modular systems, a Field-Programmable Gate Array (FPGA) can act as an embedded central routing fabric for this communication to take place. Embedded systems are versatile enough to interface with various devices and systems to accomplish various goals. Additionally, embedded systems require relatively small physical designs to minimize the required resources to facilitate the intended application by providing low-level system access. This minimization of system resources goes hand in hand with reducing the financial cost of a proposed solution or system. As remotely collaborating researchers often use FPGAs to prototype designs that are required to have a method for data transmission among systems, it is imperative to provide a baseline standard for communications among devices and systems. A typical method of implementing the Modbus RTU communication protocol in an embedded environment is using integrated logic architectures within the FPGA called “Intellectual Property (IP) cores.” IP cores can be designed using integrated logic or circuit designs to function as an embedded processor. These IP cores can then perform the required computational actions to support the Modbus RTU communication protocol by utilizing high-level programming languages such as the C programming language. The hardware description language of Very High-Speed Integrated Circuit Hardware Description Language (VHDL) allows for the control of real hardware at the logic gate and signal level. These logic gates and signals can be designed and controlled to perform desired actions based on the system design. Programming an FPGA using VHDL allows an individual to access the lowest abstraction level of the system during FPGA development. This level of abstraction is referred to as the register-transfer level (RTL), which gives access to manipulating values and variables at the register level. This register-level manipulation provides precision over creating the logical circuit within the FPGA, thus minimizing the required code to perform desired operations. The Modbus RTU communication protocol can be implemented within an FPGA using VHDL programming to establish a standardized and embedded serial communication pathway. This implementation provides a standardized communication protocol to streamline research efforts among researchers, thus increasing the efficiency of research efforts. Additionally, this Modbus RTU implementation requires fewer resources when compared to typical communication protocol implementations that utilize an IP core, reducing the hardware requirement for effective research efforts.

communication↗

Analysis to Inform CA Grid Integration Rules for PV: Final Report on Inverter Settings for Transmission and Distribution System Performance

The fourth solicitation of the California Solar Initiative (CSI) Research, Development, Demonstration and Deployment (RD&D) Program established by the California Public Utilities Commission (CPUC) supported the Electric Power Research Institute (EPRI), National Renewable Energy Laboratory (NREL), and Sandia National Laboratories (SNL) with data provided from Pacific Gas and Electric (PG&E), Southern California Edison (SCE), and San Diego Gas and Electric (SDG&E) conducted research to determine optimal default settings for distributed energy resource advanced inverter controls. The inverter functions studied are aligned with those developed by the California Smart Inverter Working Group (SIWG) and those being considered by the IEEE 1547 Working Group. The advanced inverter controls examined to improve the distribution system response included power factor, volt-var, and volt-watt. The advanced inverter controls examined to improve the transmission system response included frequency and voltage ride-through as well as Dynamic Voltage Support. This CSI RD&D project accomplished the task of developing methods to derive distribution focused advanced inverter control settings, selecting a diverse set of feeders to evaluate the methods through detailed analysis, and evaluating the effectiveness of each method developed. Inverter settings focused on the transmission system performance were also evaluated and verified. Based on the findings of this work, the suggested advanced inverter settings and methods to determine settings can be used to improve the accommodation of distributed energy resources (PV specifically). The voltage impact from PV can be mitigated using power factor, volt-var, or volt-watt control, while the bulk system impact can be improved with frequency/voltage ride-through.

14 SOLAR ENERGY↗

Controller-Hardware-in-the-Loop Test Bed for Fast-Switching SiC-Based 50-kW PV Inverter

The recent advent of wideband gap power semiconductor devices will lay the path to the future power converters. These devices provide the advantage of high switching speed and lower losses. The high cost and high switching speeds of these devices provide a challenge in the development and validation of the fast switching inverter controls with accuracy of that of a hardware setup. In this paper an FPGA real-time simulator-based controller-hardware-in-the-loop (CHIL) testbed is used to verify the low-level and advanced inverter controls fast switching wide bandgap-based string photovoltaic inverter. The paper also includes development of the CHIL testbed, which is run at a time-step of 500 ns in order to implement 20 kHz switching frequency. The developed CHIL testbed is validated through experimental results from a three-phase, 50 kW, 480 VLLrms SiC devices based inverter.

14 SOLAR ENERGY↗

Overvoltage Prevention and Curtailment Reduction Using Adaptive Droop-Based Supplementary Control in Smart Inverters

Recent developments in the renewable energy sector have seen an unprecedented growth in residential photovoltaic (PV) installations. However, high PV penetration levels often lead to overvoltage problems in low-voltage (LV) distribution feeders. Smart inverter control such as active power curtailment (APC)-based overvoltage control can be implemented to overcome these challenges. The APC technique utilizes a constant droop-based approach which curtails power rigidly, which can lead to significant energy curtailment in the LV distribution feeders. In this paper, different variations of the APC technique with linear, quadratic, and exponential droops have been analyzed from the point-of-view of energy curtailment for a LV distribution network in North America. Further, a combinatorial approach using various droop-based APC methods in conjunction with adaptive dynamic programming (ADP) as a supplementary control scheme has also been proposed. The proposed approach minimizes energy curtailment in the LV distribution network by adjusting the droop gains. Simulation results depict that ADP in conjunction with exponential droop reduces the energy curtailment to approximately 50% compared to using the standard linear droop.

42 ENGINEERING↗

Synthesizing Virtual Oscillators to Control Islanded Inverters

Virtual oscillator control (VOC) is a decentralized control strategy for islanded microgrids where inverters are regulated to emulate the dynamics of weakly nonlinear oscillators. Compared to droop control, which is only well defined in sinusoidal steady state, VOC is a time-domain controller that enables interconnected inverters to stabilize arbitrary initial conditions to a synchronized sinusoidal limit cycle. However, the nonlinear oscillators that are elemental to VOC cannot be designed with conventional linear-control design methods. We address this challenge by applying averaging- and perturbation-based nonlinear analysis methods to extract the sinusoidal steady-state and harmonic behavior of such oscillators. The averaged models reveal conclusive links between real- and reactive-power outputs and the terminal-voltage dynamics. Similarly, the perturbation methods aid in quantifying higher order harmonics. The resultant models are then leveraged to formulate a design procedure for VOC such that the inverter satisfies standard ac performance specifications related to voltage regulation, frequency regulation, dynamic response, and harmonic content. Experimental results for a single-phase 750 VA, 120 V laboratory prototype demonstrate the validity of the design approach. They also demonstrate that droop laws are, in fact, embedded within the equilibria of the nonlinear-oscillator dynamics. This establishes the backward compatibility of VOC in that, while acting on time-domain waveforms, it subsumes droop control in sinusoidal steady state.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Standard Library Plant Controller Model Specification for a Grid-Forming Hybrid Control Inverter-Based Resource (REPCGFM_C1)

This document describes a standard library plant controller model to interface with the grid-forming hybrid control inverter-based resource (IBR) model. The initial version of model specification was jointly developed by Pacific Northwest National Laboratory (PNNL), Tesla Energy, and EPRI, and it was revised multiple times later to incorporate suggestions from WECC MVS members. Tesla Energy provided main control algorithms to support the development of this model specification. This standard library model is developed to help the utility industry better understand the GFM technology. The model could be used to represent equipment for long-term planning studies where vendor-specific models are not available. As equipment matures and improves, standard library models will be updated to capture the new functionalities of GFMs. It is not intended that these models will always remain representative of all future GFM technologies.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Standard Library Grid-Forming Hybrid Control Inverter-Based Resource Model Specification (REGFM_C1)

This document describes a standard library grid-forming (GFM) hybrid control inverter-based resource (IBR) model. The GFM hybrid control approach implements both a typical GFM control and a typical grid-following (GFL) control inside one single inverter simultaneously, so that it can take advantage of both methods without comprising the benefits of a typical GFM. The initial version of model specification was jointly developed by Pacific Northwest National Laboratory (PNNL), Tesla Energy, and EPRI, and it was revised multiple times later to incorporate suggestions from WECC MVS members. Tesla Energy provided main control blocks to support the development of this model specification. This standard library model is developed to help the utility industry better understand the GFM technology. The model could be used to represent equipment for long-term planning studies where vendor-specific models are not available. As equipment matures and improves, standard library models will be updated to capture the new functionalities of GFMs. It is not intended that these models will always remain representative of all future GFM technologies.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Model Identification of Inverter Nonlinear Control Dynamics

To comprehensively predict in silico potential disruptive dynamic performance of converter-based generation and develop solutions, the application of electromagnetic transient programs is desirable. However, these accurate simulations highly depend on inverter models of actual field implementations, which are often unavailable because they are proprietary. To address this problem, we propose a time-domain model identification method that can be used to determine the control models of inverters in continuous time from multiple experimental studies. The focus is on identifying the dynamic representation of controls because they dominate the dynamic response of renewable assets. To illustrate the applicability of the technique, we consider a subclass of inverter controllers for autonomous grid applications that rely on nonlinear oscillators.

24 POWER TRANSMISSION AND DISTRIBUTION↗

LLM-Based Adaptive Distribution Voltage Regulation Under Frequent Topology Changes: An In-Context MPC Framework

This paper proposes a large language model (LLM) based adaptive inverter control for distribution voltage regulation under frequent topology changes. We leverage the ability of the LLM to perform in-context learning and create a topology-adaptive surrogate model for power flow calculation. The surrogate model is then integrated with a long short-term memory-based load forecaster and a model predictive control (MPC) scheme to achieve the optimal inverter control that adapts to frequent topology changes. Unlike many existing works that assume fixed-topology grids or require the knowledge of all possible topologies when training a model, the proposed in-context MPC method tackles the distribution voltage control problem under various topologies and adapts to unknown topologies with limited data requirement for fine-tuning. The effectiveness of our method is demonstrated on a modified IEEE 123-bus test system.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Large-Scale Adoption of Self-Synchronized Universal Droop Controller-Based Inverters to Enable Ancillary Services for Different Modes of Distribution System Operations

This work proposes the large-scale adoption of self-synchronized universal droop controller (SUDC)-based inverters to enable ancillary services for different modes of distribution system operations. The IEEE 123 bus system was modeled on a real-time simulator to study the performance of large-scale adoption of SUDC inverters in a distribution system. The resulting data collected shows that the voltage and the frequency were regulated within ranges, such as less than 5% for voltage and less than 0.5% for frequency, under different load variations and grid operations. Also, the black start was achieved within 0.4 s without any voltage overshoot. Through the simulation and validation on a small microgrid and the IEEE 123 bus distribution system, it can be concluded that the SUDC was successfully adopted to regulate the voltage and the frequency within the given ranges, and black start achieved within 1 s without voltage overshoot for different modes of distribution system operations.

14 SOLAR ENERGY↗

Photovoltaic Inverter Momentary Cessation: Recovery Process is Key

Momentary cessation refers to an inverter control mode. When the inverter terminal voltage falls below (or exceeds) a certain level, the inverter ceases to output any current, but attempts to maintain (or quickly regain) phase-locked loop synchronization to allow for quick reinjection of current when the voltage recovers to a certain point. This paper presents a photovoltaic (PV) momentary cessation model developed in PSS/E. Simulations are presented for a high voltage transmission line fault contingency in the Hawaiian island of Oahu power system on a validated PSS/E model, modified to include a custom distributed PV inverter model, and different near-future distributed PV penetration levels. Simulations for the island power system include different penetration levels of PV, and different recovery times (ramp rates and delays) after momentary cessation. The results indicate that during low voltage events, such as faults, momentary cessation can produce severe under frequency events, causing significant load shed and shortly thereafter, in some cases, over frequency events that cause generation to trip offline. The problem is exacerbated with higher penetration levels of PV. If momentary cessation is used (as is typically the case for distribution-connected resources), the recovery process after momentary cessation should be carefully considered to minimize impacts to bulk power system stability.

14 SOLAR ENERGY↗

Optimal Structures for Voltage Controllers in Inverters: Preprint

Output voltage regulation is a primary performance objective in power electronics systems which are not supported by a stiff voltage source. In this paper, we pose an optimal voltage control problem for ac inverter systems and study the structure of the resulting feedback laws. Here, it is demonstrated that the solution to the optimal voltage regulation control problem exhibits an inner current-controller structure even though there are no explicit objectives on tracking current which are targeted. Furthermore, the outer-loop voltage control and inner-loop current control structure is insensitive to the weighting transfer functions used in the optimal control problem. Although the inner-outer structure has been used in prior works, the optimal nature of such a structure was not known. In deriving the optimal controller, we also present a systematic design framework which is cognizant of the physical properties of inverters. Case studies are used to study the optimal controller and its performance.

24 POWER TRANSMISSION AND DISTRIBUTION↗