Search NASA⌕ Search

SEARCH · Search NASA

Results for “Inverter Controls”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Smart Inverters, Dumb Risk: Taking Control of IBR Security in the Digital Age

This presentation addresses the security challenges posed by Inverter-Based Resources (IBRs) in the modern energy landscape. The presentation highlights the vulnerabilities and risks associated with IBRs, including the potential for cyber-attacks, the impact of insecure defaults, and the systemic risks posed by supply chain dependencies. Key topics covered include: 1) The increasing digital transformation in energy systems and the associated security risks. 2) Specific vulnerabilities in IBRs, including weak passwords, hardcoded credentials, and insecure web application interfaces. 3) The implications of persistent connectivity and the strategic risks posed by foreign-manufactured components. 4) The role of regulatory frameworks, such as NERC CIP, in addressing these challenges and the limitations of current oversight. 5) Practical solutions for mitigating risks, including secure design practices, vendor risk assessments, and the importance of strong passwords and role-based access control. The presentation underscores the necessity of a comprehensive, system-of-systems approach to securing IBRs, emphasizing the need for collaboration across various stakeholders, including operators, developers, and regulators, to ensure the resilience and security of the energy grid.

24 - POWER TRANSMISSION AND DISTRIBUTION↗

Control and protection system for paralleled modular static inverter-converter systems

A control and protection system was developed for use with a paralleled 2.5-kWe-per-module static inverter-converter system. The control and protection system senses internal and external fault parameters such as voltage, frequency, current, and paralleling current unbalance. A logic system controls contactors to isolate defective power conditioners or loads. The system sequences contactor operation to automatically control parallel operation, startup, and fault isolation. Transient overload protection and fault checking sequences are included. The operation and performance of a control and protection system, with detailed circuit descriptions, are presented.

Birchenough, A. G.↗

Robust Control Algorithm for a Two Cart System and an Inverted Pendulum

The Rectilinear Control System can be used to simulate a launch vehicle during liftoff. Several control schemes have been developed that can control different dynamic models of the rectilinear plant. A robust control algorithm was developed that can control a pendulum to maintain an inverted position. A fluid slosh tank will be attached to the pendulum in order to test robustness in the presence of unknown slosh characteristics. The rectilinear plant consists of a DC motor and three carts mounted in series. Each cart s weight can be adjusted with brass masses and the carts can be coupled with springs. The pendulum is mounted on the first cart and an adjustable air damper can be attached to the third cart if desired. Each cart and the pendulum have a quadrature encoder to determine position. Full state feedback was implemented in order to develop the control algorithm along with a state estimator to determine the velocity states of the system. A MATLAB program was used to convert the state space matrices from continuous time to discrete time. This program also used a desired phase margin and damping ratio to determine the feedback gain matrix that would be used in the LabVIEW program. This experiment will allow engineers to gain a better understanding of liquid propellant slosh dynamics, therefore enabling them to develop more robust control algorithms for launch vehicle systems

Wilson, Chris L.↗

Advanced Mathematics for Control System Design: Guidance, Navigation, and Control (GN&C) Studies

The study and control of inverted pendulum dynamics is of interest to NASA to better control the stability of a rocket. The different compartments of a rocket can move within a rocket during launch (i.e., rocket fuel slosh) and can affect its overall trajectory. Focusing on the inverted pendulum robot, PENNY, the dynamics are reduced to a simpler model which can prove to be more insightful for deriving more complex models and control laws. From the inverted pendulum bot, we can incorporate complexity into our physical model and approximate to the dynamics of a rocket (i.e., flexible inverted pendulum, multistage pendulum).

Autonomy↗

Terminology and concepts of control and Fuzzy Logic

Viewgraphs on terminology and concepts of control and fuzzy logic are presented. Topics covered include: control systems; issues in the design of a control system; state space control for inverted pendulum; proportional-integral-derivative (PID) controller; fuzzy controller; and fuzzy rule processing.

Aldridge, Jack↗

NASA's X-57 High Lift Motor Controller: Detailed Design, Test Results, and Outcomes

NASA's X-57 all-electric aircraft was a research project aimed at investigating lightweight and efficient electric propulsion components. The general approach was to utilize a distributed electric propulsion (DEP) design. An essential component of this design was the High Lift Motor Controller (HLMC), a motor drive which provided power to the High Lift Motors (HLMs) and High Lift Propellers (HLPs) responsible for providing additional thrust for take-off and landing. This paper presents the detailed design, test results, and outcomes from the development of the HLMC, a 14 kW, 1kg, 98.3% efficient, outer mold line (OML) cooled, silicon carbide (SiC) MOSFET-based inverter and controller.

Electric Aircraft↗

NASA's X-57 High Lift Motor Controller: Detailed Design, Test Results, and Outcomes

NASA's X-57 all-electric aircraft was a research project aimed at investigating lightweight and efficient electric propulsion components. The general approach was to utilize a distributed electric propulsion (DEP) design. An essential component of this design was the High Lift Motor Controller (HLMC), a motor drive which provided power to the High Lift Motors (HLMs) and High Lift Propellers (HLPs) responsible for providing additional thrust for take-off and landing. This paper presents the detailed design, test results, and outcomes from the development of the HLMC, a 14 kW, 1kg, 98.3% efficient, outer mold line (OML) cooled, silicon carbide (SiC) MOSFET-based inverter and controller.

Electric Aircraft↗

Circuit controls transients in SCR inverters

Elimination of starting difficulties in SCR inverters is accomplished by the addition of two taps of the output winding of the inverter. On starting or under transient loads, the two additional taps deliver power through diodes without requiring quenching of SCR currents in excess of normal starting load.

Moore, E. T.↗

Silicon controlled rectifier polyphase bridge inverter commutated with gate-turn-off thyristor

A polyphase SCR inverter (10) having N switching poles, each comprised of two SCR switches (1A, 1B; 2A, 2B . . . NA, NB) and two diodes (D1B; D1B; D2A, D2B . . . DNA, DNB) in series opposition with saturable reactors (L1A, L1B; L2A, L2B . . . LNA, LNB) connecting the junctions between the SCR switches and diodes to an output terminal (1, 2 . . . 3) is commutated with only one GTO thyristor (16) connected between the common negative terminal of a dc source and a tap of a series inductor (14) connected to the positive terminal of the dc source. A clamp winding (22) and diode (24) are provided, as is a snubber (18) which may have its capacitance (c) sized for maximum load current divided into a plurality of capacitors (C.sub.1, C.sub.2 . . . C.sub.N), each in series with an SCR switch S.sub.1, S.sub.2 . . . S.sub.N). The total capacitance may be selected by activating selected switches as a function of load current. A resistor 28 and SCR switch 26 shunt reverse current when the load acts as a generator, such as a motor while braking.

Edwards, Dean B.↗

Demonstrating the Need for Adaptive Droop Control for Grid-Forming Inverters in Islanded and Grid-Connected Modes

This paper demonstrates the need of adaptive droop of grid-forming (GFM) inverters operating in different operation modes (grid-connected and islanded). A pure hardware microgrid comprising multiple grid-forming (GFM) inverters from different vendors, multiple grid-following inverters, and a diesel generator is used for the demonstration. The key findings are summarized as follows: Tighter droop slope should be used in the islanded mode, and looser droop slope should be used in the grid-connected mode to ensure stability. It is important to have adaptive droop control in GFM inverters to ensure stable and reliable microgrid operation.

14 SOLAR ENERGY↗

Variable frequency inverter for ac induction motors with torque, speed and braking control

A variable frequency inverter was designed for driving an ac induction motor which varies the frequency and voltage to the motor windings in response to varying torque requirements for the motor so that the applied voltage amplitude and frequency are of optimal value for any motor load and speed requirement. The slip frequency of the motor is caused to vary proportionally to the torque and feedback is provided so that the most efficient operating voltage is applied to the motor. Winding current surge is limited and a controlled negative slip causes motor braking and return of load energy to a dc power source.

Nola, F. J.↗

Manual control

Man's nonlinear characteristics and his use of control with compatible and incompatible multiple inputs, both visual and vestibular were studied. Experiments were also made with pulse and bang-bang controllers and the effects of sudden changes in control stick mechanical impedance. Closing the loop through the dynamics of the controlled vehicle allowed experiments on the limits of control of unstable vehicles with and without motion cues. The inverted pendulum controlled element, programmed as a self pacing element, was used extensively as a scalar performance index. In addition, the motorbike equations of motion were studied with regard to required human equalization. Abstracts are included for a series of published data on manual control.

Source record↗

Pulse width modulation inverter with battery charger

An inverter is connected between a source of DC power and a three-phase AC induction motor, and a microprocessor-based circuit controls the inverter using pulse width modulation techniques. In the disclosed method of pulse width modulation, both edges of each pulse of a carrier pulse train are equally modulated by a time proportional to sin .theta., where .theta. is the angular displacement of the pulse center at the motor stator frequency from a fixed reference point on the carrier waveform. The carrier waveform frequency is a multiple of the motor stator frequency. The modulated pulse train is then applied to each of the motor phase inputs with respective phase shifts of 120.degree. at the stator frequency. Switching control commands for electronic switches in the inverter are stored in a random access memory (RAM) and the locations of the RAM are successively read out in a cyclic manner, each bit of a given RAM location controlling a respective phase input of the motor. The DC power source preferably comprises rechargeable batteries and all but one of the electronic switches in the inverter can be disabled, the remaining electronic switch being part of a flyback DC-DC converter circuit for recharging the battery.

Slicker, James M.↗

Stability-Constrained Learning for Frequency Regulation in Power Grids With Variable Inertia

The increasing penetration of converter-based renewable generation has resulted in faster frequency dynamics, and low and variable inertia. As a result, there is a need for frequency control methods that are able to stabilize a disturbance in the power system at timescales comparable to the fast converter dynamics. This paper proposes a combined linear and neural network controller for inverter-based primary frequency control that is stable at time-varying levels of inertia. We model the time-variance in inertia via a switched affine hybrid system model. We derive stability certificates for the proposed controller via a quadratic candidate Lyapunov function. We test the proposed control on a 12-bus 3-area test network, and compare its performance with a base case linear controller, optimized linear controller, and finite-horizon Linear Quadratic Regulator (LQR). Our proposed controller achieves faster mean settling time and over 50% reduction in average control cost across 100 inertia scenarios compared to the optimized linear controller. Unlike LQR which requires complete knowledge of the inertia trajectories and system dynamics over the entire control time horizon, our proposed controller is real-time tractable, and achieves comparable performance to LQR.

data-driven control↗

Wind Power as a Virtual Synchronous Generator (WindVSG)

This project investigated the theory, implemented it in hardware, and validated the Wind as a Virtual Isochronous Generator (WindVSG) concept by combining the advantages of modern dynamic inverter technologies with static, dynamic, and transient electromechanical properties of synchronous machines. During this project we demonstrated how to control the inverters of wind turbine generators (wind alone or in parallel with other GFM sources, such battery energy storage) so that wind power behaves like a synchronous machine-based power plant with a conventional prime mover. For this purpose, testing was conducted at NLR ARIES facility with real 2.5 MW wind-turbine generator operating in GFM mode under dynamic and transient conditions. The team also developed models and conducted simulations for GFM wind power to evaluate stability impacts of GFM operation on power grid. This report describes efforts by the NLR team working in collaboration GE Vernova during 3-year project.

17 WIND ENERGY↗

Microgrid Black Start Challenges: The Role of Grid-Forming Inverters

Grid-forming (GFM) inverters are becoming increasingly important for future power systems, particularly in establishing and restarting microgrids after blackouts. The use of GFM inverters enables microgrids to operate independently of utility power and provide key advantages over synchronous generators in black start scenarios, including rapid startup and stable voltage and frequency support for critical loads. However, inverter-driven black start introduces unique challenges and operational considerations. This article examines key challenges and solutions, emphasizing inverter design, control strategies, and microgrid system requirements. Drawing on analysis, simulation, and experimental results, this article highlights the central role of GFM inverters in ensuring reliable and resilient microgrid operations.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Stable and Ultrafast Control for Multiparallel Grid-Tied SiC Inverters With LVRT Capability Considering Cable Impedance

The stability of multiparalleled grid-tied inverters remains a challenging issue especially during low-voltage ride-through (LVRT) in the presence of grid impedance. SiC device-based grid-tied inverters can achieve advantages such as higher efficiency, reduced size of interface filters, and fast dynamics; however, they can exacerbate this stability issue particularly when LVRT occurs along with high inrush current due to their low inertia characteristics. In this article, a direct deadbeat control method without any PI control loop is proposed for multiparallel grid-tied SiC inverters. The proposed control achieves instantaneous current regulations within switching cycles. In addition, it mitigates high inrush currents and maintains stability during LVRT transients without requiring mode transitions between normal and LVRT operation modes, thereby achieving an ultrafast response and seamless operation through this unified control method. The Lyapunov method is applied to analyze the multiparallel inverter stability in the presence of grid impedance with proposed deadbeat control method. The inverter V-I trajectories during LVRT transients are derived to illustrate the ultrafast and stable feature of proposed control. Finally, the experimental results of two grid-tied SiC inverters operating at LVRT transients are provided to verify the advantages of the proposed control method.

14 SOLAR ENERGY↗