Search NASA⌕ Search

SEARCH · Search NASA

Results for “Ion probe data”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Planetary nebulae

The role of the IUE in the study of planetary nebulae (PN) is discussed as well as extinction, the central star and nebular spectra, plasma diagnostics, the chemical compositions of PN, and nebular models. Some information on the spatial distribution of C(2+) or C(3+) ions may be acquired for extended PN from IUE data, making it possible to probe ionization zones different from those observable in the visual region. For high resolution pertaining to filamentary structure and clumpiness, optical region images and data obtained with the Hubble Space Telescope are needed.

Koeppen, J.↗

Observations of the nightside Venus ionosphere: Final encounter of the Pioneer Venus Orbiter Ion Mass Spectrometer

During the last orbital sequences of the Pioneer-Venus spacecraft prior to final encounter and atmospheric entry, data were obtained by the Orbiter Ion Mass Spectrometer (OIMS) at the lowest periapsis altitudes of the mission. These data verified OIMS observations of the nightside ionospheric peak reported earlier in the mission, and revealed additional details related to composition, energetics and maintenance of the nightside ionosphere. OIMS observations of the ion peak during the final encounter sequence are compared with radio occultation data and OIMS peak observations obtained earlier. OIMS ion density and Orbiter Electron Temperature Probe (OETP) electron density are found to correlate near the peak. Coupling of mass channels 30 and 32 during nightside passes is observed and its interpretation considered. Changes in high altitude composition of the nightside ionosphere, especially the relative changes in O(+) and H(+), are described.

Cloutier, P. A.↗

Observations of the Nightside Venus Ionosphere: Final Encounter of the Pioneer Venus Orbiter Ion Mass Spectrometer

During the last orbital sequences of the Pioneer Venus spacecraft prior to final encounter and atmospheric entry, data were obtained by the Orbiter Ion Mass Spectrometer (OIMS) at the lowest periapsis altitudes of the mission. These data verified OIMS observations of the nightside ionospheric peak reported-earlier in the mission, and revealed additional details related to composition, energetics and maintenance of the nightside ionosphere. OIMS observations of the ion peak during the final encounter sequence are compared with radio occultation data and OIMS peak observations obtained earlier. OIMS ion density and Orbiter Electron Temperature Probe (OETP) electron density are found to correlate near the peak. Coupling of mass channels 30 and 32 during nightside passes is observed and its interpretation considered. Changes in high altitude composition of the nightside ionosphere, especially the relative changes in O(+) and H(+), are described.

Cloutier, P. A.↗

Langmuir Probe Measurements of Inductively Coupled Plasmas in CF4/Ar/O2 Mixtures

Fluorocarbon gases, such as CF4, and their mixtures are widely used in contemporary low-pressure and high-density plasma processing techniques. In such plasmas Langmuir probe is one of the most commonly employed diagnostic techniques to obtain electron number density (ne), electron temperature (Te), electron energy distribution function (EEDF), mean electron energy (Ee), ion number density (ni), and plasma potential (Vp). In this paper we report probe data for planar inductively coupled plasmas in CF4/O2/Ar mixtures. By varying the relative concentrations in the mixture, radial profiles of ne, ni, Te, Ee, Vp, EEDF were measured in the mid-plane of the plasma at 10 mTorr and 20 mTorr of gas pressures, and 200 W and 300 W of RF powers. Data show that ne and ni decrease with increase of CF4 content and decrease of gas-pressure but they increase with increase of RF-power, whereas Vp increases with decrease of gas-pressure and remains independent of RF-power. However, they all peak at the center of the plasma and decrease towards the edge while Te follows the other way and increases a little with increase of power. The measured EEDFs exhibit Druyvesteyn-like distribution at all pressures and powers. Data are analyzed and will be presented.

Rao, M. V. V. S.↗

Studies of the chemistry of the nightside ionosphere of Venus

A combination of numerical modeling and analysis of the Pioneer Venus UADS data base is studied, specifically data from the orbiter ion mass spectrometer (OIMS), orbiter neutral mass spectrometer (ONMS), and orbiter electron temperature probe (OETP). A one dimensional model of the Venus nightside ionosphere was set up in which downward fluxes of atomic ions are introduced at the upper boundary to simulate transport of ions from the dayside. The model shows that the densities of mass-28 ions, CO(+) + N(2+), resulting from an influx of atomic ions from the dayside are quite small, due to the high ionization potentials of CO and N2 that make chemical production difficult. A look at the data reveals that the actual densities of mass-28 ions are quite variable, from values near 10 to more than 10(exp 4) cm(exp -3). The excess mass-28 ions are assumed to be produced by electron precipitation and that the presence of high densities of mass-28 ions is a signature of auroral precipitation. A discussion of the atomic oxygen green line in the nightglow of Venus, which is produced mainly by dissociative recombination of O(2+), is presented. Original calculations of production rates of excited states for models based on Pioneer Venus data are also presented.

Fox, J. L.↗

The nightward ion flow scenario at Venus revisited

We indicate how existing Pioneer Venus Orbiter (PVO) data might be used to gain a better understanding of nightward ion flow in the Venusian ionosphere. Calculations based on PVO measurements made at solar maximum suggest that the global nightward flow of O(+) may be signifcantly greater than is required to maintain the observed nightside ionosphere densities. The validity of this conclusion depends upon (1) the accuracy with which the flow can be determined from the PVO ion density and velocity measurements and (2) the validity of the ionosphere theory used to estimate the required downward O(+) flux on the night side. If the measurements and theory are assumed to be accurate, the excess nightward flow implies a significant rate of ion escape from the planet, particularly at times of low solar wind dynamic pressure, Psw, when the ionopause rises to allow increased nightward flow. To illustrate a potentially important mechanism for ion escape from Venus, we present Orbiter Electron Temperature Probe (OETP) observations of plasma clouds and scavenged ionospheric plasma observed above the ionopause. We then employ OETP and Orbiter Retarding Potential Analyzer (ORPA) data to reexamine the global ion flow for average Psw conditions.

Brace, L. H.↗

Bayesian Model for HOPE Mass Spectrometers on Van Allen Probes

Space instruments rely heavily on modeling to predict and understand the instrument response, enabling a determination of the capabilities and resolution. The Bayesian approach provides a framework to incorporate prior knowledge and propagate uncertainty to predict the instrument response. We present an empirical Bayes model for the end-to-end performance of the Helium, Oxygen, Proton, and Electron mass spectrometers aboard the Van Allen Probes mission. In this model, we use a combination of external modeling, laboratory calibration, and expert opinion to construct the time-of-flight spectra and demonstrate good agreement with on-orbit data. The empirical Bayes model is applied to explore doubly charged ions and carbon, nitrogen, oxygen discrimination during the Van Allen Probes mission.

47 OTHER INSTRUMENTATION↗

Estimating Electron Temperature and Density Using Van Allen Probe Data: Typical Behavior of Energetic Electrons in the Inner Magnetosphere

Abstract The Earth's inner magnetosphere contains multiple electron populations influenced by different factors. The cold electrons of the plasmasphere, warm plasma that contributes to the ring current, and the relativistic plasma of the radiation belts often seem to behave independently. Using omni‐directional flux and energy measurements from the HOPE and Magnetic Electron Ion Spectrometer instruments aboard the Van Allen Probes, we provide a detailed density and temperature description of the inner magnetosphere, offering a comprehensive statistical analysis of the entire Van Allen Probe era. While number density and temperature data at geosynchronous orbit are available, this study focuses on the warm plasma in the inner magnetosphere . Values of density and temperature are extracted by fitting energy and phase space density to obtain the distribution function. The fitted distributions are related to the zeroth and second moments to estimate the number density and temperature. Analysis has indicated that a two Maxwellian fit is sufficient over a wide range of and that there are two independent plasma populations. The more energetic population has a median number density of approximately and a temperature of around 130 keV, with a temperature peak observed between L * = 4 and L * = 4.5. This population is relatively uniform in magnetic local time (MLT). In contrast, the less energetic warm electron population has a median number density of about and a temperature of 7.4 keV. Strong statistical trends in density and temperature across both L * and MLT are presented, along with potential sources driving these variations.

58 GEOSCIENCES↗

Electron and ion temperature data for ionospheric modelling

The major sources ionospheric temperature data are the incoherent scatter radars and in situ instruments (Langmuir probe, retarding potential analyzer) flown on several long-lasting satellite missions. The paper provides an overview over the different data sets and discusses their volume, temporal and spatial resolution, accuracy, and their availability. The state-of-the-art of empirical modeling of ionospheric plasma temperatures is examined, and present shortcomings and future data needs are pointed out. Special emphasis is given to the representation of auroral features, temperature anisotropies, and of solar-cycle variations. Finally, the possibility of using theoretical results to fill data gaps for empirical modeling is considered.

Bilitza, Dieter↗

Relativistic Electron Response to the Combined Magnetospheric Impact of a Coronal Mass Ejection Overlapping with a High-Speed Stream: Van Allen Probes Observations

During early November 2013, the magnetosphere experienced concurrent driving by a coronal mass ejection (CME) during an ongoing high-speed stream (HSS) event. The relativistic electron response to these two kinds of drivers, i.e., HSS and CME, is typically different, with the former often leading to a slower buildup of electrons at larger radial distances, while the latter energizing electrons rapidly with flux enhancements occurring closer to the Earth. We present a detailed analysis of the relativistic electron response including radial profiles of phase space density as observed by both Magnetic Electron and Ion Sensor (MagEIS) and Relativistic Electron Proton Telescope instruments on the Van Allen Probes mission. Data from the MagEIS instrument establish the behavior of lower energy (<1 MeV) electrons which span both intermediary and seed populations during electron energization. Measurements characterizing the plasma waves and magnetospheric electric and magnetic fields during this period are obtained by the Electric and Magnetic Field Instrument Suite and Integrated Science instrument on board Van Allen Probes, Search Coil Magnetometer and Flux Gate Magnetometer instruments on board Time History of Events and Macroscale Interactions during Substorms, and the low-altitude Polar-orbiting Operational Environmental Satellites. These observations suggest that during this time period, both radial transport and local in situ processes are involved in the energization of electrons. The energization attributable to radial diffusion is most clearly evident for the lower energy (<1 MeV) electrons, while the effects of in situ energization by interaction of chorus waves are prominent in the higher-energy electrons.

Magnetosphere↗

The Fixed-bias Langmuir Probe on the Communication-navigation Outage Forecast System Satellite: Calibration and Validation

A fixed-bias spherical Langmuir probe is included as part of the Vector Electric Field Instrument (VEFI) suite on the Communication Navigation Outage Forecast System (CNOFS) satellite.CNOFS gathers data in the equatorial ionosphere between 400 and 860 km, where the primary constituent ions are H+ and O+. The ion current collected by the probe surface per unit plasmadensity is found to be a strong function of ion composition. The calibration of the collected current to an absolute density is discussed, and the performance of the spherical probe is compared to other in situ instruments on board the CNOFS satellite. The application of the calibration is discussed with respect to future xed-bias probes; in particular, it is demonstrated that some density fluctuations will be suppressed in the collected current if the plasma composition rapidly changes along with density. This is illustrated in the observation of plasma density enhancements on CNOFS.

VEFI↗

The Fixed-Bias Langmuir Probe on the Communication-Navigation Outage Forecast System Satellite: Calibration and Validation

A fixed-bias spherical Langmuir probe is included as part of the Vector Electric Field Instrument (VEFI) suite on the Communication Navigation Outage Forecast System (CNOFS) satellite.CNOFS gathers data in the equatorial ionosphere between 400 and 860 km, where the primary constituent ions are H+ and O+. The ion current collected by the probe surface per unit plasma density is found to be a strong function of ion composition. The calibration of the collected current to an absolute density is discussed, and the performance of the spherical probe is compared to other in situ instruments on board the CNOFS satellite. The application of the calibration is discussed with respect to future fixed-bias probes; in particular, it is demonstrated that some density fluctuations will be suppressed in the collected current if the plasma composition rapidly changes along with density. This is illustrated in the observation of plasma density enhancements on CNOFS.

Vector Electric Field Instrument↗

Revealing latent pole and zone line information in atom probe detector maps using crystallographically correlated metrics

Poles and zone lines observed within atom probe field evaporation images are useful for a range of atom probe crystallography studies, including calibration of the reconstruction and crystallographic characterisation of microstructural features such as grain boundaries. However, this information is not always readily apparent. Techniques for plotting crystallographically correlated metrics contained within atom probe data to enhance pole and zone line contrast across the detector space are developed. This includes consideration of the electric field, molecular ions, lattice structure retained within the reconstruction, specific elemental species, the number of pulses between detection events, and the lateral distance between sequential detection events. These approaches are then applied to experimental atom probe tomography datasets on technically pure Al, nanocrystalline Al, highly doped Si, and additively manufactured Inconel 738, Haynes 282, and Ti–6Al–4V. The results facilitate the extension of atom probe crystallography studies to a broader range of crystalline datasets where crystallographic information is not readily apparent from existing methods, as well as a deeper understanding of field evaporation behaviour during an atom probe experiment.

47 OTHER INSTRUMENTATION↗

Multioutput Convolutional Neural Network for Improved Parameter Extraction in Time-Resolved Electrostatic Force Microscopy Data

Time-resolved scanning probe microscopy methods, like time-resolved electrostatic force microscopy (trEFM), enable imaging of dynamic processes ranging from ion motion in batteries to electronic dynamics in microstructured thin film semiconductors for solar cells. Reconstructing the underlying physical dynamics from these techniques can be challenging due to the interplay of cantilever physics with the actual transient kinetics of interest in the resulting signal. Previously, quantitative trEFM used empirical calibration of the cantilever or feed-forward neural networks trained on simulated data to extract the physical dynamics of interest. Both these approaches are limited by interpreting the underlying signal as a single exponential function, which serves as an approximation but does not adequately reflect many realistic systems. Here, we present a multi-branched, multi-output convolutional neural network (CNN) that uses the trEFM signal in addition to the physical cantilever parameters as input. The trained CNN accurately extracts parameters describing both single-exponential and bi-exponential underlying functions, and more accurately reconstructs real experimental data in the presence of noise. This article demonstrates an application of physics-informed machine learning to complex signal processing tasks, enabling more efficient and accurate analysis of trEFM.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Studies of acceleration processes in the corona using ion measurements on the solar probe mission

The energy spectra and composition of particles escaping from the Sun provide essential information on mechanisms responsible for their acceleration, and may also be used to characterize the regions where they are accelerated and confined and through which they propagate. The suprathermal energy range, which extends from solar wind energies (approximately 1 KeV) to about 1 MeV/nucleon, is of special interest to studies of nonthermal acceleration processes because a large fraction of particles is likely to be accelerated into this energy range. Data obtained from near earth observations of particles in the suprathermal energy range are reviewed. The necessary capabilities of an a ion composition experiment in the solar probe mission and the required ion measurements are discussed. A possible configuration of an instrument consisting of an electrostatic deflection system, modest post acceleration, and a time of flight versus energy system is described as well as its possible location on the spacecraft.

Gloeckler, G.↗

On Ba(+) production in the CRIT 2 experiment

Analysis of partical data from the CRIT 2 experiment, studying Alfven's critical ionization velocity (CIV) effect, shows that the density of newly created ions (presumably Ba(+) from the shaped-charge beam) is consistent with the increase in total plasma density measured by the independent RF plasma probe on board (Swenson et al., 1990) at the most active time period. We model this ion production using the measured electron flux data and the neutral barium model of Stenbaek-Nielsen et al. (1990a). To identify the main source mechanisms which may contribute most to the barium ionization, a simple model for the barium ion density at the payload location is developed based on Liouvilles theorem. We estimate that the electron impact ionization is responsible for 90% of the barium ion production observed by CRIT 2 in the first release and up to 45% in the second release. By employing a two-state approximation calculation (Rapp and Francis, 1962), the Ba-O(+) charge exchange cross section is found to range from about 2.0 X 10(exp -17) sq cm at a velocity of 4 km/s to 2.0 X 10(exp -15) sq cm at a velocity of 20 km/s. This result suggests that the Ba-O(+) charge exchange is probably dominant among all the non-CIV ionization processes. By considering the charge exchange process in our density model, the barrium ion densities are calculated for the two releases on CRIT II. The comparison between the model results and the observed data is found to be resonably consistent if the cross sections, as calculated above, are multiplied by 0.3 for the first release and 1.0 for the second release. Our result suggests that the charge exchange process could be the most important non-CIV ionization mechanism in the CRIT II experiment and it should be considered carefully case by case in CIV experiments.

Liou, K.↗

The formation of FeO-rich pyroxene and enstatite in unequilibrated enstatite chondrites: A petrologic-trace element (SIMS) study

Enstatite (En) chondrites record the most reducing conditions known in the early solar system. Their oxidation state may be the result of condensation in a nebular region having an enhanced C/O ratio, reduction of more oxidized materials in a reducing nebula, reduction during metamorphic reheating in a parent body, or a combination of these events. The presence of more oxidized Fe-rich silicates, two types of En (distinguished by red and blue CL), and the juxtaposition of FeO-rich pyroxenes (Fe-pyx) surrounded by blue En (enstatite) in the UEC's (unequilibrated enstatite chondrites) is intriguing and led to the examination of the question of enstatite chondrite formation. Previously, data was presented on the petrologic-geochemical characteristics of the Fe-pyx and coexisting red and blue En. Here minor and trace element abundances (determined by ion probe-SIMS) on these three types of pyroxenes are reported on in the following meteorites: Kota Kota and LEW87223 (EH3), MAC88136 (EL3), St. Marks (EH4), and Hvittis (EL6). More data are currently being collected.

Weisberg, M. K.↗

Transversely accelerated ions in the topside ionosphere

Data from the rocket campaigns Mechanism in the Auroral Region for Ion Energization (MARIE) and TOpside Probe of the Auroral Zone (TOPAZ) III, within regions of low-altitude transversely accelerated ions, are interpreted to explain the acceleration of the ions. Using the Monte Carlo kinetic technique to evaluate the ion heating produced by the simultaneously observed lower hybrid waves, we find that their observed electric field amplitudes are sufficient to explain the observed ion energies in the MARIE event. Much of the uncertainty in evaluating the efficiency of a plasma wave induced particle heating process which is dependent on a velocity resonance comes from the lack of information on the phase velocities of the waves. In the case of the MARIE observations, our modeling efforts show that features in the ion velocity distribution are consistent with the wave phase velocities inferred from interferometer measurements of wavelengths. The lower hybrid waves with which low-altitude transversely accelerated ions are associated are frequently observed to be concentrated in small-scale wave packets called 'spikelets'. We demonstrate through the scaling of the size of these wave packets that they are consistent with the theory of lower hybrid collapse. Using the Monte Carlo technique, we find that if the lower hybrid field energy is concentrated in these wave packets, it is still adequate to accelerate the ionospheric ions to the observed energies.

Retterer, John M.↗