Search NASA⌕ Search

SEARCH · Search NASA

Results for “Ionizing Dose”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Design and assembling status of the Mu2e electromagnetic calorimeter mechanical structures

The muon-to-electron conversion (Mu2e) experiment at Fermilab will search for the Charged Lepton Flavour Violating neutrino-less coherent conversion of a muon into an electron in the field of an aluminum nucleus. The observation of this process would be the unambiguous evidence of physics beyond the Standard Model. The detector has been designed as a state-of-the-art crystal calorimeter and employs 1348 pure Cesium Iodide (CsI) crystals readout by UV-extended silicon photosensors and fast front-end and digitization electronics. A design consisting of two identical annular matrices (named disks ) positioned at the relative distance of 70 cm, downstream the aluminum target along the muon beamline, satisfies the Mu2e physics requirements. The hostile Mu2e operational conditions, in terms of radiation levels (total ionizing dose of 12 krad and a neutron fluence of 5 10^{10} n/cm2 @ 1 MeVeq (Si)/y), magnetic field intensity (1 T) and vacuum level (10−4 Torr) have posed tight constraints on the design of the detector mechanical structures and materials choice. The support structure of the two 674 crystal matrices employs two aluminum hollow rings and parts made of open- cell vacuum-compatible carbon fiber. The photosensors and service front-end electronics for each crystal are assembled in a unique mechanical unit inserted in a machined copper holder. The 674 units are supported by a machined plate made of vacuum-compatible plastic material. The plate also integrates the cooling system made of a network of copper lines flowing a low temperature radiation-hard fluid and placed in thermal con- tact with the copper holders. The data acquisition electronics is hosted in aluminum custom crates positioned on the external lateral surface of the two disks. The crates also integrate the electronics cooling system. In this poster we will review the constraints on the calorimeter mechanical structures, the technological choices, and the status of assembling at Fermilab.

Pasciuto, D.↗

Van de Graaff Irradiation Studies of Oxygen Sensor and Hydrated Zirconia Sorbent

Commercial-scale production of Mo-99 demands a facility-wide assessment of radiation-induced degradation across process equipment, instrumentation, and purification media. Key factors— total ionizing dose, dose rate, radiolysis-driven chemistry, thermal loads, activation, and any neutron-related effects—should inform material selection, shielding, and component layout. Purification materials (sorbents, resins, filters, seals, housing) require particular attention to ensure that irradiation does not alter selectivity or capacity, generate fines, or introduce leachables that could compromise Mo-99 purity or downstream Tc-99m generator performance. Dose mapping, accelerated irradiation testing, and studies of extractables/leachables together provide the basis for setting maintenance, calibration, and replacement intervals and for qualifying materials that retain mechanical integrity, chemical compatibility, and radiopurity over their service life.

36 MATERIALS SCIENCE↗

Development, construction and qualification tests of the mechanical structures of the electromagnetic calorimeter of the Mu2e experiment at Fermilab

The “muon-to-electron conversion” (Mu2e) experiment at Fermilab will search for the Charged Lepton Flavour Violating neutrino-less coherent conversion of a muon into an electron in the field of an aluminum nucleus. The observation of this process would be the unambiguous evidence of physics beyond the Standard Model. Mu2e detectors comprise a straw-tracker, an electromagnetic calorimeter and an external veto for cosmic rays. The calorimeter provides excellent electron identification, complementary information to aid pattern recognition and track reconstruction, and a fast calorimetric online trigger. The detector has been designed as a state-of-the-art crystal calorimeter and employs 1340 pure Cesium Iodide (CsI) crystals readout by UV-extended silicon photosensors and fast front-end and digitization electronics. A design consisting of two identical annular matrices (named “disks”) positioned at the relative distance of 70 cm downstream the aluminum target along the muon beamline satisfies the Mu2e physics requirements.The hostile Mu2e operational conditions, in terms of radiation levels (total ionizing dose of 12 krad and a neutron fluence of 5x1010 n/cm2 @ 1 MeVeq (Si)/y), magnetic field intensity (1 T) and vacuum level (10$^{-4}$ Torr) have posed tight constraints on the design of the detector mechanical structures and materials choice. The support structure of the two 670 crystal matrices employs two aluminum hollow rings and parts made of open-cell vacuum-compatible carbon fiber. The photosensors and service front-end electronics for each crystal are assembled in a unique mechanical unit inserted in a machined copper holder. The 670 units are supported by a machined plate made of vacuum-compatible plastic material. The plate also integrates the cooling system made of a network of copper lines flowing a low temperature radiation-hard fluid and placed in thermal contact with the copper holders to constitute a low resistance thermal bridge. The data acquisition electronics is hosted in aluminum custom crates positioned on the external lateral surface of the two disks. The crates also integrate the electronics cooling system as lines running in parallel to the front-end system.The constraints on the calorimeter mechanical structures design, the development from the conceptual design to the specifications of all the structural components, the status of components production and the components quality assurance tests are presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The Readout Electronics of the Mu2e Electromagnetic Calorimeter

The Mu2e electromagnetic calorimeter has been designed to measure ~100 MeV electrons with energy resolution σE/E <10%, time resolution σt < 500ps and position resolution σx < 1cm. The detector is composed of 1348 un-doped CsI crystals coupled to two large area Silicon Photomultipliers (SiPMs). Each SiPM is connected to a Front End Electronics (FEE) chip which hosts the shaping amplifier and the high voltage linear regulator. A group of 20 FEE is controlled by one Mezzanine Board (MB) which transmits the amplified signals to one Digitizer ReAdout Controller board (DiRAC). The DiRAC samples the waveforms at 200 MHz with 12-bit ADCs, packs the data according to the Mu2e custom format and transmits them to the event builder through an optical transceiver. To limit the number of pass-through connectors and the length of the cables, the readout and digitization electronics is located inside the detector cryostat and close to the interaction target. The boards will have to sustain a neutron fluence of about 5x10 10 n/cm 2 @ 1 MeVeq (Si)/y and a Total Ionizing Dose of about 12 krad, while working into a 1T magnetic field and a vacuum of 10 (-4) Torr. This harsh operational environment has made the electronics design challenging and required an extended campaign of tests to select and qualify the employed electronic components. In this paper we report on the board architecture and design, on the qualification of the prototypes, as well as on the results of the first vertical slice test of the Mu2e calorimeter.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Radiation tolerance of the PNI RM3100 magnetometer for a Europa lander mission

The results of two radiation test campaigns on a low-cost commercial off-the-shelf magnetometer are presented. The test setup and the total ionization dose (TID) levels studied were designed to meet the requirements of a mission to land on Europa. Based on the Europa Lander Science Definition Team report, instruments inside an aluminum vault at the surface of Europa would need to withstand TID of up to 300 krad(SI). In order to evaluate the performance of the PNI RM3100 magnetometer, nine separate sensors were irradiated at two different facilities during two separate campaigns and under different configurations, including passive and active tests. Of the nine sensors, seven survived the TID of 300 krad(SI) while the other two sensors started presenting failures after reaching 150 krad(SI). Post-irradiation tests showed that eight of the nine sensors continued to work without appreciable degradation after stopping exposure, while one sensor stopped working altogether.

58 GEOSCIENCES↗

The Analog Front-end for the LGAD Based Precision Timing Application in CMS ETL

The analog front-end for the Low Gain Avalanche Detector (LGAD) based precision timing application in the CMS Endcap Timing Layer (ETL) has been prototyped in a 65 nm CMOS mini-ASIC named ETROC0. Serving as the very first prototype of ETL readout chip (ETROC), ETROC0 aims to study and demonstrate the performance of the analog frontend, with the goal to achieve 40 to 50 ps time resolution per hit with LGAD (therefore reach about 30ps per track with two detector-layer hits per track). ETROC0 consists of preamplifier and discriminator stages, which amplifies the LGAD signal and generates digital pulses containing time of arrival and time over threshold information. This paper will focus on the design considerations that lead to the ETROC front-end architecture choice, the key design features of the building blocks, the methodology of using the LGAD simulation data to evaluate and optimize the front-end design. The ETROC0 prototype chips have been extensively tested using charge injection and the measured performance agrees well with simulation. The initial beam test results are also presented, with time resolution of around 33 ps observed from the preamplifier waveform analysis and around 41 ps from the discriminator pulses analysis. A subset of ETROC0 chips have also been tested to a total ionizing dose of 100 MRad with X-ray and no performance degradation been observed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

LLNL Low dose-related research

LLNL has a long history of involvement in research into biological and biophysical methods for assessing ionizing radiation dose, and LLNL staff continue to participate in reviews of low dose related data as well as technology development for national security and population health purposes. A list of recent projects and funding agencies is provided in Table 1. LLNL has also maintained expertise in mammalian biology, radiobiology and cancer (computational and biological) over the last 5 years.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Ionization detail parameters and cluster dose: a mathematical model for selection of nanodosimetric quantities for use in treatment planning in charged particle radiotherapy

Abstract Objective . To propose a mathematical model for applying ionization detail (ID), the detailed spatial distribution of ionization along a particle track, to proton and ion beam radiotherapy treatment planning (RTP). Approach . Our model provides for selection of preferred ID parameters ( I p ) for RTP, that associate closest to biological effects. Cluster dose is proposed to bridge the large gap between nanoscopic I p and macroscopic RTP. Selection of I p is demonstrated using published cell survival measurements for protons through argon, comparing results for nineteen I p : N k , k = 2, 3, …, 10, the number of ionizations in clusters of k or more per particle, and F k , k = 1, 2, …, 10, the number of clusters of k or more per particle. We then describe application of the model to ID-based RTP and propose a path to clinical translation. Main results . The preferred I p were N 4 and F 5 for aerobic cells, N 5 and F 7 for hypoxic cells. Significant differences were found in cell survival for beams having the same LET or the preferred N k . Conversely, there was no significant difference for F 5 for aerobic cells and F 7 for hypoxic cells, regardless of ion beam atomic number or energy. Further, cells irradiated with the same cluster dose for these I p had the same cell survival. Based on these preliminary results and other compelling results in nanodosimetry, it is reasonable to assert that I p exist that are more closely associated with biological effects than current LET-based approaches and microdosimetric RBE-based models used in particle RTP. However, more biological variables such as cell line and cycle phase, as well as ion beam pulse structure and rate still need investigation. Significance . Our model provides a practical means to select preferred I p from radiobiological data, and to convert I p to the macroscopic cluster dose for particle RTP.

Engineering↗

Human perception of ionizing radiation

Here, in this work, we address the question of whether humans can perceive ionizing radiation. We conducted a thorough review of the clinical and experimental literature related to ionizing radiation, with a focus on its acute effects. Specifically, we examined the three domains of X-ray perception found in animals (abdominal, olfactory, and retinal), which led us to instances of ionizing radiation-induced hearing and taste sensory phenomena in humans thus suggesting that humans can perceive X-rays across various sensory modalities via multiple mechanisms. We also analyzed literature to understand the mechanisms associated with reported symptoms, this led us to the concept of radiomodulation, an understudied modulatory effect of sub-ablative ionizing radiation doses on neurons. Based on this review of the literature we propose the hypothesis that a significant radiomodulation mechanism is the formation of reactive oxygen species from radiolysis which activates immune and sensory signal transduction mechanisms specifically related to the redox activity in TRP and K+ channels. Additionally, we find evidence to support the previous claims of perception stemming from Cherenkov radiation and ozone production which are perceived using canonical sensory modalities. Finally, for we provide a concise summary of the applications of ionizing radiation in clinical imaging and therapy, as well as prospects for future developments of radiation technologies for biomedical and fundamental research.

Ionizing radiation↗

Effects of Ionizing Radiation on the Thermodynamic Stability of Boehmite and Gibbsite

Here, in this study, we examined the effect of gamma radiation on the stabilities of aluminum hydroxide (gibbsite) and aluminum oxyhydroxide (boehmite) nanoparticles in relation to their thermal decomposition. X-ray diffraction (XRD) patterns and scanning electron microscopy (SEM) images revealed no significant differences in mineral components or morphology before and after radiation. However, thermogravimetric and differential scanning calorimetry (TGA/DSC) analyses showed that both boehmite and gibbsite nanoparticles experienced decreased mass loss following irradiation. Raman and attenuated total reflection-Fourier transfer infrared (ATR-FTIR) spectra indicated that a fraction of the hydroxyl content in both cases was selectively cleaved by radiation, primarily at the particle surfaces. Quantitative analyses of thermal mass loss behavior demonstrated that irradiated boehmite and gibbsite nanoparticles had higher activation energies than their pristine counterparts, with the extent of the increase dependent on the total dose. Taken together, these findings suggest that exposure to a sufficient dose of ionizing radiation alters these materials such that they are less prone to decomposition by dehydration. This increased stability may be due to the decreased hydrous nature of the samples after radiation exposure, which was supported by further high temperature drop calorimetry. Additionally, a radiation-induced amorphous phase on the nanoparticle surfaces appears to have a permanent and positive influence on their thermodynamic stabilities.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Exposure to ionizing radiation disrupts normal epigenetic aging in Japanese medaka

Alterations to the epigenome are a hallmark of biological aging and age-dependent patterning of the DNA methylome (“epigenetic aging”) can be modeled to produce epigenetic age predictors. Rates of epigenetic aging vary amongst individuals and correlate to the onset of age-related disease and all-cause mortality. Yet, the origins of epigenetic-to-chronological age discordance are not empirically resolved. Here, we investigate the relationship between aging, DNA methylation, and environmental exposures in Japanese medaka (Oryzias latipes). We find age-associated DNA methylation patterning enriched in genomic regions of low CpG density and that, similar to mammals, most age-related changes occur during early life. We construct an epigenetic clock capable of predicting chronological age with a mean error of 61.1 days (~8.4% of average lifespan). To test the role of environmental factors in driving epigenetic age variation, we exposed medaka to chronic, environmentally relevant doses of ionizing radiation. Because most organisms share an evolutionary history with ionizing radiation, we hypothesized that exposure would reveal fundamental insights into environment-by-epigenetic aging interactions. Radiation exposure disrupted epigenetic aging by accelerating and decelerating normal age-associated patterning and was most pronounced in cytosines that were moderately associated with age. These findings empirically demonstrate the role of DNA methylation in integrating environmental factors into aging trajectories.

60 APPLIED LIFE SCIENCES↗

Electrochemical Manipulation and Radiolytic Evaluation of Organic Phase Neptunium

Presentation for Seed LDRD proposal presentation: This Seed LDRD research proposes to test an innovative approach to precisely control the oxidation state distribution of neptunium (Np) under used nuclear fuel (UNF) reprocessing conditions using novel electrochemical methods. Current UNF reprocessing technologies are not financially viable in the US, requiring significant scientific and technological innovation to improve cost efficiency. Reducing the number of process cycles is one avenue for increasing cost efficiency, of which resolving the challenge associated with isolating Np is critical. Under envisioned process conditions, Np is present in a mixture of extractable (Np(IV) and Np(VI)) and inextractable (Np(V)) oxidation states, the distribution of which is dependent on several factors, including ionizing radiation dose, that change throughout a reprocessing scheme. Consequently, Np unintentionally partitions into various UNF reprocessing phases and product streams, ultimately increasing the number of process cycles to isolate UNF components. Here, we propose to employ novel, high surface area, optically transparent, Ligand Modified tin-doped indium oxide Electrodes (LMES). These LMEs bind Np, and therefore enable concurrent generation and spectroscopic characterization of Np oxidation states in organic solutions. These proof-of-concept experiments will: (i) facilitate optimization of the proposed electrochemical system conditions for Np oxidation state manipulation; (ii) identify the accessible electrochemical window for Np complexes in the organic phase; (iii) report characteristic optical spectra for each accessible complexed Np oxidation state; and (iv) determine the lifetime and partitioning of a given atypical Np oxidation state in the organic phase in the presence and absence of ionizing radiation fields. The data gathered by this Seed LDRD will provide support for the design of an electrochemical process concept for the precise manipulation of Np oxidation states in UNF reprocessing solvent systems, with the intention of providing advanced control over Np mass transfer, and thus greater process efficiency and economy.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

An electrochemical generator for the continual supply of 213 Bi from 225 Ac for use in targeted alpha therapy applications

Bismuth-213 is a radionuclide of interest for targeted alpha therapy and is supplied via a radiochemical generator system through the decay of 225 Ac. Radionuclide generators employ longer lived “parent” radionuclides to routinely supply shorter-lived “daughter” radionuclides. The traditional 225 Ac/ 213 Bi radiochemical generator relies on an organic cation exchange resin where 225 Ac binds to the resin and 213 Bi is routinely eluted. These resins degrade when they absorb large doses of ionizing radiation (>1 × 10 6 Gy/mg), which has been observed when the loading activity of 225 Ac exceeds 2.59*10 9 Bq (70 mCi). Herein we report the development of an electrochemical generator for the supply of 213Bi that has the potential to overcome this limitation. Bismuth-213 spontaneously electrodeposits onto nickel foils in 0.1 M hydrochloric acid at 70 °C. Using this method, we were able to plate an average of 73 ± 4 % of the 213 Bi in solution and obtain a final 213 Bi recovery of 65 ± 8 % in 0.1 M citrate pH 4.5 via reverse electrolysis using titanium as the cathode. The recovered 213Bi had an average radiochemical purity of >99.8 % and was successfully used to radiolabel DOTATATE with an average radiochemical yield of 85.1 % (not optimized).

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Crossroads Able "Gilda"

At 5:55 am local time on June 30, 1946, a B-29 bomber took to the air carrying a Fat Man bomb, christened Gilda. Named after a Rita Haworth movie character, Gilda was released over a target array of ninety-three ships, including the Japanese battleship Nagato, the German cruiser Prinz Eugen, and the United States aircraft carrier Independence, all of which carried varying amounts of munitions, fuel, and animals. Although Gilda missed its aiming point, the explosion sank five ships and severely damaged eight others. A large number of pigs, goats, and rats were exposed to lethal doses of ionizing radiation. Visually, Gilda was not that impressive, particularly to those expecting an apocalyptic event. As the New York Times reporter William Laurence recalled, “To some of the newspaper men aboard, keyed up to the point of expecting the observer ship to be blown out of the water, the spectacle, obscured somewhat by an intervening white cloud, was a disappointment. To me, who could distinguish between the natural cloud and the atomic cloud, the sight was awesome and spine chilling.”

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Optical and photoelectric properties of surface barrier diodes based on n- Hg3In2Te6 crystals

The high radiation resistance of Hg3In2Te6 (MIT) single crystals to large doses of ionizing radiation makes devices quite attractive. Such a feature of the crystal structure has not only important advantages, but also causes serious technological difficulties in doping and controlling the specific resistance within the required limits and type of conductivity of single crystals. These technological difficulties create serious problems when creating structures with a potential barrier, especially with a p-n junction. At the moment, there are no publications on the creation of a p-n junction based on MIT. The only alternative is to create a potential barrier such as a Schottky diode or a metal-dielectric-semiconductor structure. This limits the use of MIT to produce, for example, rectifier diodes that can operate at relatively high reverse bias voltages. The typical resistivity of single crystals of MIT of n-type conductivity, which are used for the manufacture of diodes and photodiodes, is approximately equal to ρ≈103-104 Ω×cm. Such a specific resistance leads to a relatively large resistance of the neutral part of the single crystal, which in turn limits the direct currents of the rectifier diodes and significantly limits an important parameter of photodiodes - the dynamic range of the watt-ampere characteristic. This problem arises from the relatively high series resistance of the substrate. For rectifier diodes, this relatively large series resistance leads to a significant forward bias voltage drop, which reduces both the rectification factor and the amount of rectified current. We have already created diodes and photodiodes on Cr/MIT/Cr single crystals with a specific resistance of ρ≈103-104 Ω×cm. The diodes had relatively small dark currents but had the disadvantage of a relatively large specific resistance of the substrate, which we have already discussed above [1,2,3].

Sklyarchuk, V.↗

Space weather observations, modeling, and alerts in support of human exploration of Mars

Space weather observations and modeling at Mars have begun but they must be significantly increased to support the future of Human Exploration on the Red Planet. A comprehensive space weather understanding of a planet without a global magnetosphere and a thin atmosphere is very different from our situation at Earth so there is substantial fundamental research remaining. It is expected that the development of suitable models will lead to a comprehensive operational Mars space weather alert (MSWA) system that would provide rapid dissemination of information to Earth controllers, astronauts in transit, and those in the exploration zone (EZ) on the surface by producing alerts that are delivered rapidly and are actionable. To illustrate the importance of such a system, we use a magnetohydrodynamic code to model an extreme Carrington-type coronal mass ejection (CME) event at Mars. The results show a significant induced surface field of nearly 3,000 nT on the dayside that could radically affect unprotected electrical systems that would dramatically impact human survival on Mars. Other associated problems include coronal mass ejection (CME) shock-driven acceleration of solar energetic particles producing large doses of ionizing radiation at the Martian surface. In summary, along with working more closely with international partners, the next Heliophysics Decadal Survey must include a new initiative to meet expected demands for space weather forecasting in support of humans living and working on the surface of Mars. It will require significant effort to coordinate NASA and the international community contributions.

79 ASTRONOMY AND ASTROPHYSICS↗