Search NASA⌕ Search

SEARCH · Search NASA

Results for “Ions Separations”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Assessing Collision Cross Section Calibration Strategies for Traveling Wave-Based Ion Mobility Separations in Structures for Lossless Ion Manipulations

The collision cross section (CCS) is an important property that aids in the structural characterization of molecules. Here, we investigated the CCS calibration accuracy with traveling waves ion mobility spectrometry (TWIMS) separations in structures for lossless ion manipulations (SLIM) using three sets of calibrants. A series of singly negatively-charged phospholipids and bile acids were calibrated in nitrogen buffer gas using two different TW waveform profiles (square and sine) and amplitudes (20 V0-p, 25 V0-p, and 30 V 0-p ). The calibration errors for the three calibrant sets Agilent tuning mixture and polyalanine, and one assembled in-house showed negligible differences using a sine-shaped TW waveform. Furthermore, calibration errors were all within 1-2 % of the DTIMS measurements, with lower errors for sine waveforms, presumably due to the lower average and maximum fields experienced by ions. Finally, ultrahigh resolution multi-pass (long path length) SLIM TWIMS demonstrated improved CCS calibration for phospholipid and bile acid isomers.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Squeezing of Ion Populations and Peaks in Traveling Wave Ion Mobility Separations and Structures for Lossless Ion Manipulations using Compression Ratio Ion Mobility Programming

In this work, we report an approach for spatial and temporal gas phase ion population manipulation, and demonstrate its application for the collapse of the ion distributions in ion mobility (IM) separations into tighter packets providing higher sensitivity measurements in conjunction with mass spectrometry (MS). We do this for ions moving from a conventionally traveling wave (TW)-driven region to a region where the TW is intermittently halted or ‘stuttered’. This approach causes the ion packets spanning a number of TW-created traveling traps (TT) to be redistributed into fewer TT, resulting in spatial compression. The degree of spatial compression is controllable and determined by the ratio of stationary time of the TW in the second region to its moving time. This compression ratio ion mobility programming (CRIMP) approach has been implemented using Structures for Lossless Ion Manipulations (SLIM) in conjunction with MS. CRIMP with the SLIM-MS platform is shown to provide increased peak intensities, reduced peak widths, and improved S/N ratios with MS detection. CRIMP also provides a foundation for extremely long path length and multi-pass IM separations in SLIM providing greatly enhanced IM resolution by reducing the detrimental effects of diffusional peak broadening due to increasing peak widths.

Environmental Molecular Sciences Laboratory↗

Evaluation of Waveform Profiles for Traveling Wave Ion Mobility Separations in Structures for Lossless Ion Manipulations

Structures for lossless ion manipulations (SLIM) have recently enabled a powerful implementation of traveling wave ion mobility spectrometry (TWIMS) for ultra-high resolution separations. However, optimization of experimental parameters remains challenging. Most TWIMS separations have utilized square-shaped waveforms applied by time-dependent voltage stepping across a repeating sets of electrodes; however, alternative waveforms may provide further improvements to resolution. In this work, we characterize five waveforms (including square and sine) in terms of their transmission efficiency, IMS resolution, and resolving power, and explore the effects of TW amplitude and speed on the performance of each. We found, consistent with previous work, separations were generally improved with higher TW amplitudes, moderately improved by lower speeds (limited by ion ‘surfing’ with the waves), and found decreases in signal intensity at the extremes of operating conditions. The triangle and asymmetric ‘ramp forward’ shaped profiles were found to provide modestly greater resolution and resolving power, an observation we tentatively attribute to their relatively uniform fields and minimal low-field regions.

59 BASIC BIOLOGICAL SCIENCES↗

Method and device for ion mobility separations

Methods and devices for ion separations or manipulations in gas phase are disclosed. The device includes a single non-planar surface. Arrays of electrodes are coupled to the surface. A combination of RF and DC voltages are applied to the arrays of electrodes to create confining and driving fields that move ions through the device. The DC voltages are static DC voltages or time-dependent DC potentials or waveforms.

47 OTHER INSTRUMENTATION↗

Method and device for ion mobility separation

Methods and devices for ion separations or manipulations in gas phase are disclosed. The device includes a non-planar surface having a first, second and third region. An inner arrays of electrodes is positioned on the first region. A first set of electrodes of the inner array of electrodes is configured to receive RF voltages and generate a first potential upon the receipt of the RF voltage. A first and second outer arrays of electrodes are coupled to the second and third region, respectively. The first and second outer arrays are configured to receive a first DC voltage and generate a second potential upon the receipt of the first DC voltages. The first and second generated potential manipulate movement of ions.

74 ATOMIC AND MOLECULAR PHYSICS↗

Laser‐ablation electrospray ionization mass spectrometry with ion mobility separation reveals metabolites in the symbiotic interactions of soybean roots and rhizobia

Summary Technologies enabling in situ metabolic profiling of living plant systems are invaluable for understanding physiological processes and could be used for rapid phenotypic screening (e.g., to produce plants with superior biological nitrogen‐fixing ability). The symbiotic interaction between legumes and nitrogen‐fixing soil bacteria results in a specialized plant organ (i.e., root nodule) where the exchange of nutrients between host and endosymbiont occurs. Laser‐ablation electrospray ionization mass spectrometry ( LAESI ‐ MS ) is a method that can be performed under ambient conditions requiring minimal sample preparation. Here, we employed LAESI ‐ MS to explore the well characterized symbiosis between soybean ( Glycine max L. Merr.) and its compatible symbiont, Bradyrhizobium japonicum . The utilization of ion mobility separation ( IMS ) improved the molecular coverage, selectivity, and identification of the detected biomolecules. Specifically, incorporation of IMS resulted in an increase of 153 differentially abundant spectral features in the nodule samples. The data presented demonstrate the advantages of using LAESI – IMS – MS for the rapid analysis of intact root nodules, uninfected root segments, and free‐living rhizobia. Untargeted pathway analysis revealed several metabolic processes within the nodule (e.g., zeatin, riboflavin, and purine synthesis). Compounds specific to the uninfected root and bacteria were also detected. Lastly, we performed depth profiling of intact nodules to reveal the location of metabolites to the cortex and inside the infected region, and lateral profiling of sectioned nodules confirmed these molecular distributions. Our results established the feasibility of LAESI – IMS – MS for the analysis and spatial mapping of plant tissues, with its specific demonstration to improve our understanding of the soybean‐rhizobial symbiosis.

Stopka, Sylwia A.↗

Ion Mobility Separations Using Cocentric Architecture

Ion mobility separations are usually performed in linear channels, which, when extended, can have a large footprint. In this work, we explored the performance of an ion mobility device with a curved architecture which can have a more compact form. The Co-centric Ion Mobility Spectrometer (CIMS) works by manipulating ions between two co-centric surfaces, each containing a serpentine track. The mobility separation inside CIMS is achieved using traveling waveforms (TWs). We initially evaluated the device using ion trajectory simulations using SIMION, which indicated that when ions traveled circularly inside CIMS, they resulted in similar resolving powers and transmitted m/z range as traveling in a straight path in structures for lossless ion manipulations (SLIM). We then performed experimental validation of CIMS in conjunction with a TOF MS. The CIMS was made of 2 flexible printed circuit board materials folded into concentric cylinders separated by a gap of 2.8 mm. The device was about 50 mm diameter × 152 mm long and provided 1.846 m of serpentine path length. Three sets of mixtures (Agilent tune mixture, tetraalkylammonium salts, and 8 peptide mixture) and four traveling waveform profiles (square, sine, triangle, and sawtooth) were used. The sawtooth TW profile produced a slightly higher resolving power for the Agilent tuning mixture and tetraalkylammonium ions. The average resolving power for Agilent tune mixture ions ranged from 37 (using sawtooth TW) to 27 (using square TW). For tetraalkylammonium ions, the average resolving powers ranged from 45 (sawtooth TW) to 31 (square TW). For the peptide mixture ions, the resolving power was similar among the four TW profiles and ranged from 51 to 56. The average percent error in TW CCS for the peptide mixture ions ranged was about 0.4%. In conclusion, the new device showed promising results for a device made of a flexible printed circuit board material, but improvements are needed to further increase the resolving power.

59 BASIC BIOLOGICAL SCIENCES↗

Achieving High Resolution Ion Mobility Separations Using Traveling Waves in Compact Multiturn Structures for Lossless Ion Manipulations

We report on ion mobility separations (IMS) achievable using traveling waves in a Structures for Lossless Ion Manipulations (TW-SLIM) module having a 44-cm path length and sixteen 90º turns. The performance of the TW-SLIM module was evaluated for ion transmission, and ion mobility separations with different RF, TW parameters and SLIM surface gaps in conjunction with mass spectrometry. In this work TWs were created by the transient and dynamic application of DC potentials. The TW-SLIM module demonstrated highly robust performance and the ion mobility resolution achieved even with sixteen close spaced turns was comparable to a similar straight path TW-SLIM module. We found an ion mobility peak capacity of ~ 31 and peak generation rate of 780 s-1 for TW speeds of <210 m/s using the current multi-turn TW-SLIM module. The separations achieved for isomers of peptides and tetrasaccharides were found to be comparable to those from a ~ 0.9-m drift tube-based IMS-MS platform operated at the same pressure (4 torr). The combined attributes of flexible design, low voltage requirements and lossless ion transmission through multiple turns for the present TW-SLIM module provides a basis for SLIM devices capable of achieving much greater ion mobility resolutions via greatly extended ion path lengths and compact serpentine designs that do not significantly impact the instrumentation profile, a direction described in a companion manuscript.

Environmental Molecular Sciences Laboratory↗

Material review of Li ion battery separators

Separators for Li Ion batteries have a strong impact on cell production, cell performance, life, as well as reliability and safety. The separator market volume is about 500 million m{sup 2} mainly based on consumer applications. It is expected to grow strongly over the next decade for mobile and stationary applications using large cells. At present, the market is essentially served by polyolefine membranes. Such membranes have some technological limitations, such as wettability, porosity, penetration resistance, shrinkage and meltdown. The development of a cell failure due to internal short circuit is potentially closely related to separator material properties. Consequently, advanced separators became an intense area of worldwide research and development activity in academia and industry. New separator technologies are being developed especially to address safety and reliability related property improvements.

25 ENERGY STORAGE↗

Fast Switching Magnet for Heavy Ion Beam Separation

Fast magnets for multiplexing ion beams between different beamlines are technologically challenging and expensive, but there is an ever-growing need to develop such systems for beam separation at research and industrial facilities. For example, The Argonne Tandem Linac Accelerator System (ATLAS) is planning to expand its operations as a multi-user facility and there is a clear need, presently unmet by the industry, for a switching magnet system with the sub-millisecond transient times.In response to this problem, RadiaBeam Technologies is developing a novel pulsed switching magnet system capable of producing a 1.1T peak field over 45 cm length with a short (<1 ms) rise and fall time. The key enabling innovation in this project is an introduction of a solid-state interposed modulator architecture, which enables to improve magnet performance and reliability and reduce the cost to a practical level.

43 PARTICLE ACCELERATORS↗

Rapid Ion Mobility Separations of Bile Acid Isomers Using Cyclodextrin Adducts and Structures for Lossless Ion Manipulations

Bile acids (BAs) constitute an important class of steroid metabolites with changes implicated in disease states and other health conditions. Current analyses for these structurally similar compounds are limited by a lack of sensitivity, and long separation times with often poor isomeric resolution. To overcome these challenges and provide rapid analyses for the BA isomers, we utilized cyclodextrin adducts and ion mobility (IM) separations in structures for lossless ion manipulations (SLIM). Cyclodextrin was found to interact with both the tauro- and glyco-conjugated BA isomers studied, forming rigid noncovalent host-guest inclusion complexes. SLIM capabilities for the accumulation of large ion populations and peak compression, enabled both the sensitive detection and high-resolution separation of all the isomers studied.

Chouinard, Christopher D.↗

Enhancing Bottom-up and Top-down Proteomic Measurements with Ion Mobility Separations

Proteomic measurements with greater throughput, sensitivity and additional structural information enhance the in-depth characterization of complex mixtures and targeted studies with additional information and higher confidence. While liquid chromatography separation coupled with mass spectrometry (LC-MS) measurements have provided information on thousands of proteins in different sample types, the additional of another rapid separation stage providing structural information has many benefits for analyses. Technical advances in ion funnels and multiplexing have enabled ion mobility separations to be easily and effectively coupled with LC-MS proteomics to enhance the information content of measurements. Finally, herein, we report on applications illustrating increased sensitivity, throughput, and structural information by utilizing IMS-MS and LC-IMS-MS measurements for both bottom-up and top-down proteomics measurements.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

SLIM Ultrahigh Resolution Ion Mobility Spectrometry Separations of Isotopologues and Isotopomers Reveal Mobility Shifts due to Mass Distribution Changes

We report on separations of ion isotopologues and isotopomers using ultrahigh-resolution traveling wave-based Structures for Lossless Ion Manipulations with serpentine ultralong path and extended routing ion mobility spectrometry coupled to mass spectrometry (SLIM SUPER IMS-MS). Mobility separations of ions from the naturally occurring ion isotopic envelopes (e.g., [M], [M+1], [M+2]…ions) showed the first and second isotopic peaks (i.e. [M+1] and [M+2]) for various tetraalkylammonium ions could be resolved from their respective monoisotopic ion peak ([M]) after SLIM SUPER IMS with resolving powers of ~400-600. Similar separations were obtained for other compounds (e.g., tetrapeptide ions). Greater separation was obtained using argon versus helium drift gas, as expected from the greater reduced mass contribution to ion mobility described by the Mason-Schamp relationship. To more directly explore the role of isotopic substitutions, we studied a mixture of specific isotopically substituted (15N, 13C, and 2H) protonated arginine isotopologues. While the separations in nitrogen were primarily due to their reduced mass differences, similar to the naturally occurring isotopologues, their separations in helium, where higher resolving powers could also be achieved, revealed distinct additional relative mobility shifts. These shifts appeared correlated, after correction for the reduced mass contribution, with changes in the ion center of mass due to the different locations of heavy atom substitutions. The origin of these apparent mass distribution- induced mobility shifts was then further explored using a mixture of Iodoacetyl Tandem Mass Tag (iodoTMT) isotopomers (i.e. each having the same exact mass, but with different isotopic substitution sites). Again, the observed mobility shifts appeared correlated with changes in the ion center of mass leading to multiple monoisotopic mobilities being observed for some isotopomers (up to a ~0.04% difference in mobility). These mobility shifts thus appear to reflect details of the ion structure, derived from the changes due to ion rotation impacting collision frequency or momentum transfer, and highlight the potential for new approaches for ion structural characterization.

Isotopologues, isotopomers, SLIM, Ion Mobility Spe↗

Ion Mobility Separations of Isomers based upon Long Path Length Structures for Lossless Ion Manipulations Combined with Mass Spectrometry

Mass spectrometry (MS)-based multi-omic measurements, including proteomics, metabolomics, lipidomics, and glycomics, are increasingly transforming our ability to characterize and understand biological systems, but, presently have limitations due to the chemical diversity and range of abundances of biomolecules in complex samples. Advances addressing these challenges increasingly are based upon the ability to quickly separate, react and otherwise manipulate sample components for analysis by MS. Here we report on a new approach using Structures for Lossless Ion Manipulations (SLIM) to enable long serpentine path ion mobility spectrometry (IMS) separations followed by MS analyses. This approach provides previously unachieved mobility biomolecule isomer separations for biomolecular species, in conjunction with more effective ion utilization, and producing a basis for the improved characterization of very small samples.

Environmental Molecular Sciences Laboratory↗

Method for enhancing the resolving power of ion mobility separations over a limited mobility range

A method for raising the resolving power, specificity, and peak capacity of conventional ion mobility spectrometry is disclosed. Ions are separated in a dynamic electric field comprising an oscillatory field wave and opposing static field, or at least two counter propagating waves with different parameters (amplitude, profile, frequency, or speed). As the functional dependencies of mean drift velocity on the ion mobility in a wave and static field or in unequal waves differ, only single species is equilibrated while others drift in either direction and are mobility-separated. An ion mobility spectrum over a limited range is then acquired by measuring ion drift times through a fixed distance inside the gas-filled enclosure. The resolving power in the vicinity of equilibrium mobility substantially exceeds that for known traveling-wave or drift-tube IMS separations, with spectra over wider ranges obtainable by stitching multiple segments. The approach also enables low-cutoff, high-cutoff, and bandpass ion mobility filters.

47 OTHER INSTRUMENTATION↗

Device and method for upgrading petroleum feedstocks and petroleum refinery streams using an alkali metal conductive membrane

A reactor has two chambers, namely an oil feedstock chamber and a source chamber. An ion separator separates the oil feedstock chamber from the source chamber, wherein the ion separator allows alkali metal ions to pass from the source chamber, through the ion separator, and into the oil feedstock chamber. A cathode is at least partially housed within the oil feedstock chamber and an anode is at least partially housed within the source chamber. A quantity of an oil feedstock is within the oil feedstock chamber, the oil feedstock comprising at least one carbon atom and a heteroatom and/or one or more heavy metals, the oil feedstock further comprising naphthenic acid. When the alkali metal ion enters the oil feedstock chamber, the alkali metal reacts with the heteroatom, the heavy metals and/or the naphthenic acid, wherein the reaction with the alkali metal forms inorganic products.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

On electrolyte wetting through lithium-ion battery separators

The wettability by electrolyte is a critical characteristic of lithium-ion battery separators since electrolyte absorption is essential for ionic transport. Most importantly, fast absorption of electrolyte facilitates the electrolyte filling and wetting processes during the battery assembly. However, theoretical or experimental investigation of separator wettability has rarely been reported, and thus very little quantitative data can be found in the existing literature. Here, innovative experimental techniques and associated analytical models have been developed to fully characterize the electrolyte wetting behavior through battery separators. Both in-plane and through-plane imbibition processes are investigated. The results show that, electrolyte needs significantly longer time to wet separators than it does for commercial electrodes. The wetting rate depends significantly on the pore size, porosity, and micro-structure of the separators. Electrolyte in-plane wetting is only observed in the separators manufactured by the wet process. Increasing separator porosity and pore size is shown to be substantially increasing through-plane wetting rate. In addition, ceramic coating is shown to increase in-plane wetting but retard through-plane wetting.

25 ENERGY STORAGE↗