Ames T-3 fire test facility - Aircraft crash fire simulation

There is a need to characterize the thermal response of materials exposed to aircraft fuel fires. Large scale open fire tests are costly and pollute the local environment. This paper describes the construction and operation of a subscale fire test that simulates the heat flux levels and thermochemistry of typical open pool fires. It has been termed the Ames T-3 Test and has been used extensively by NASA since 1969 to observe the behavior of materials exposed to JP-4 fuel fires.

Fish, R. H.↗

Computer Program for the Design and Off-Design Performance of Turbojet and Turbofan Engine Cycles

The rapid computer program is designed to be run in a stand-alone mode or operated within a larger program. The computation is based on a simplified one-dimensional gas turbine cycle. Each component in the engine is modeled thermo-dynamically. The component efficiencies used in the thermodynamic modeling are scaled for the off-design conditions from input design point values using empirical trends which are included in the computer code. The engine cycle program is capable of producing reasonable engine performance prediction with a minimum of computer execute time. The current computer execute time on the IBM 360/67 for one Mach number, one altitude, and one power setting is about 0.1 seconds. about 0.1 seconds. The principal assumption used in the calculation is that the compressor is operated along a line of maximum adiabatic efficiency on the compressor map. The fluid properties are computed for the combustion mixture, but dissociation is not included. The procedure included in the program is only for the combustion of JP-4, methane, or hydrogen.

Morris, S. J.↗

Carbon fiber plume sampling for large scale fire tests at Dugway Proving Ground

Carbon fiber sampling instruments were developed: passive collectors made of sticky bridal veil mesh, and active instruments using a light emitting diode (LED) source. These instruments measured the number or number rate of carbon fibers released from carbon/graphite composite material when the material was burned in a 10.7 m (35 ft) dia JP-4 pool fire for approximately 20 minutes. The instruments were placed in an array suspended from a 305 m by 305 m (1000 ft by 1000 ft) Jacob's Ladder net held vertically aloft by balloons and oriented crosswind approximately 140 meters downwind of the pool fire. Three tests were conducted during which released carbon fiber data were acquired. These data were reduced and analyzed to obtain the characteristics of the released fibers including their spatial and size distributions and estimates of the number and total mass of fibers released. The results of the data analyses showed that 2.5 to 3.5 x 10 to the 8th power single carbon fibers were released during the 20 minute burn of 30 to 50 kg mass of initial, unburned carbon fiber material. The mass released as single carbon fibers was estimated to be between 0.1 and 0.2% of the initial, unburned fiber mass.

Chovit, A. R.↗

Measurement of the spatial dependence of temperature and gas and soot concentrations within large open hydrocarbon fuel fires

A series of large-scale JP-4 fuel pool fire tests was conducted to refine existing mathematical models of large fires. Seven tests were conducted to make chemical concentration and temperature measurements in 7.5 and 15 meter-diameter pool fires. Measurements were made at heights of 0.7, 1.4, 2.9, 5.7, 11.4, and 21.3 meters above the fires. Temperatures were measured at up to 50 locations each second during the fires. Chemistry samples were taken at up to 23 locations within the fires and analyzed for combustion chemistry and soot concentration. Temperature and combustion chemistry profiles obtained during two 7.5 meter-diameter and two 15 meter-diameter fires are included.

Johnson, H. T.↗

Assessment of crash fire hazard of LH sub 2 fueled aircraft

The relative safety of passengers in LH2 - fueled aircraft, as well as the safety of people in areas surrounding a crash scene, has been evaluated in an analytical study. Four representative circumstances were postulated involving a transport aircraft in which varying degrees of severity of damage were sustained. Potential hazard to the passengers and to the surroundings posed by the spilled fuel was evaluated for each circumstance. Corresponding aircraft fueled with liquid methane, Jet A, and JP-4 were also studied in order to make comparisons of the relative safety. The four scenarios which were used to provide a basis for the evaluation included: (1) a small fuel leak internal to the aircraft, (2) a survivable crash in which a significant quantity of fuel is spilled in a radial pattern as a result of impact with a stationary object while taxiing at fairly low speed, (3) a survivable crash in which a significant quantity of fuel is spilled in an axial pattern as a result of impact during landing, and (4) a non-survivable crash in which a massive fuel spill occurs instantaneously.

Brewer, G. D.↗

Feasibility of a nuclear gauge for fuel quantity measurement aboard aircraft

Capacitance fuel gauges have served as the basis for fuel quantity indicating systems in aircraft for several decades. However, there have been persistent reports by the airlines that these gauges often give faulty indications due to microbial growth and other contaminants in the fuel tanks. This report describes the results of a feasibility study of using gamma ray attenuation as the basis for measuring fuel quantity in the tanks. Studies with a weak Am-241 59.5-keV radiation source indicate that it is possible to continuously monitor the fuel quantity in the tanks to an accuracy of better than 1 percent. These measurements also indicate that there are easily measurable differences in the physical properties and resultant attenuation characteristics of JP-4, JP-5, and Jet A fuels. The experimental results, along with a suggested source-detector geometrical configuration are described.

Signh, J. J.↗

Gamma-Ray Fuel Gauges for Airplanes

Accurate system overcomes problems of capacitance gauges. Feasibility study conducted on use of attenuation of gamma rays to measure quantities of fuel in tanks. Studies with weak Am241 59.5-keV radiation source indicate it is possible to monitor continuously fuel quantity in tanks to accuracy of better than 1 percent. Measurements also indicate easily measurable differences in physical properties and resultant attenuation characteristics of JP-4, JP-5, and Jet A fuels. Am241-based densitometers currently in use aboard some aircraft . Estimated complete system, including microprocessor and associated display devices, assembled at cost of less than $10,000 per fuel tank.

Singh, Jag J.↗

Aviation fuel property effects on altitude relight

The major objective of this experimental program was to investigate the effects of fuel property variation on altitude relight characteristics. Four fuels with widely varying volatility properties (JP-4, Jet A, a blend of Jet A and 2040 Solvent, and Diesel 2) were tested in a five-swirl-cup-sector combustor at inlet temperatures and flows representative of windmilling conditions of turbofan engines. The effects of fuel physical properties on atomization were eliminated by using four sets of pressure-atomizing nozzles designed to give the same spray Sauter mean diameter (50 + or - 10 micron) for each fuel at the same design fuel flow. A second series of tests was run with a set of air-blast nozzles. With comparable atomization levels, fuel volatility assumes only a secondary role for first-swirl-cup lightoff and complete blowout. Full propagation first-cup blowout were independent of fuel volatility and depended only on the combustor operating conditions.

Venkataramani, K.↗

Phase 1 results from the Stirling-powered vehicle project

The NASA Technology Utilization (TU) Office is sponsoring a multiyear, multiphase demonstration program to assess the technology developed under the DOE/NASA automotive Stirling engine (ASE) program with engines installed in various Air Force vehicles while being evaluated by independent third parties under realistic conditions. This paper reviews the operational history of Phase 1 with a Mod 1 Stirling engine installed in an Air Force multistop van in a variety of missions. Ten months of operation were with Air Force personnel at Langley Air Force Base, Virginia, where over 1100 hr and 4000 mi were logged on the Langley flight line. The Stirling-powered van operated on unleaded gasoline, JP-4 aircraft fuel, and diesel fuel at Langley Air Force Base. Two months of operation were completed with Deere and Company personnel in the Moline, Illinois area where over 175 hr and 2650 mi were logged on a Deere mail delivery route.

Shaltens, Richard K.↗

Detonability of hydrocarbon fuels in air

Studies were conducted of the detonation of gas-phase mixtures of n-hexane and JP-4, with oxidizers as varied as air and pure oxygen, measuring detonation velocities and cell sizes as a function of stoichiometry and diluent concentration. The induction length of a one-dimensional Zeldovich-von Neumann-Doering detonation was calculated on the basis of a theoretical model that employed the reaction kinetics of the hydrocarbon fuels used. Critical energy and critical tube diameter are compared for a relative measure of the heavy hydrocarbon fuels studied; detonation sensitivity appears to increase slightly with increasing carbon number.

Beeson, H. D.↗

Some Effects of Exposure to Exhaust-gas Streams on Emittance and Thermoelectric Power of Bare-wire Platinum Rhodium - Platinum Thermocouples

Thermocouples were exposed to exhaust gases from the combustion of propane, 72-octane gasoline, and JP-4 fuel. Exposure increased the emissivity of the thermocouple wire, which increased its radiation error. Two methods are presented for determining the emittance of the wires. The emissivity of a clean platinum rhodium-platinum thermocouple was approximately 0.2 in the temperature range investigated, while the emittance of an exposed thermocouple coated with exhaust residue was about 0.5. The exposure caused negligible change in the thermoelectric power of the thermocouples.

Glawe, George E↗

Effect of Dissolved Oxygen on the Filterability of Jet Fuels for Temperatures Between 300 Degrees and 400 Degrees F

The effect of dissolved oxygen in the filter-clogging characteristics of three JP-4 and two JP-5 fuels was studied at 300 degrees to 400 degrees F in a bench- scale rig, employing filter paper as the filter medium. The residence time of the fuel at the high temperature was approximately 6 seconds. For these conditions, the clogging characteristics of the fuels increased with both increasing temperature and increasing concentration of dissolved oxygen. The amount of insoluble material formed at high temperatures necessary to produce clogging of filters was very small, of the order of 1 milligram per gallon of fuel.

Mckeown, Anderson B↗

Analysis of ram-jet engine performance including effects of component changes

Calculated design-point performance of ram-jet engines using JP-4 fuel is presented for a wide range of engine total-temperature ratios and combustion-chamber-inlet Mach numbers for flight numbers from 1.5 to 4.0. The results include engine thrust, drag, fuel consumption, and area ratios. Data are also presented to illustrate the sensitivity of the results to variations in the assumed component parameters. A brief comparison is included between fixed-and variable-geometry engines.

Weber, Richard J↗

Performance at Simulated High Altitudes of a Prevaporizing Annular Turbojet Combustor Having Low Pressure Loss

An annular prevaporizing turbojet combustor having pressure losses lower than those obtained in current turbojet combustors was developed, Pressure losses of 2 to 4 percent, satisfactory temperature profiles, and combustion efficiencies of 98, 88, and 81 percent were obtained at 56,000, 70,000, and 80,000 feet respectively, for a simulated 5.2- pressure-ratio engine at rated speed and 0.6 flight Mach number with JP-4 fuel. Use of JP-5 fuel resulted in a small penalty in efficiency due, at least in part, to insufficient prevaporizer capacity.

Norgren, Carl T↗

The Appearance of a Boric Oxide Exhaust Cloud from a Turbojet Engine Operating on Trimethylborate Fuel

An investigation was conducted on the size and density of the boric oxide exhaust cloud from a J47-25 turbojet engine operating on trimethylborate fuel at sea-level static condition. Movies and still photographs were taken from the ground and from a helicopter. Objects could not be perceived through the main body of the cloud at distances up to 800 feet from the engine. Data are included on the amount of fallout from the cloud and the concentration of boric oxide in the cloud. A radiation detection device was set up to determine whether the glowing oxide particles would be more susceptible than hydrocarbon exhaust gases to this type of tracking device. The device showed an increase in radiation by a factor of 3 for trimethylborate over that for JP-4.

Lord, Albert M↗

Extended Operation of Turbojet Engine with Pentaborane

A full-scale turbojet engine was operated with pentaborane fuel continuously for 22 minutes at conditions simulating flight at a Mach number of 0.8 at an altitude of 50,000 feet. This period of operation is approximately three times longer than previously reported operation times. Although the specific fuel consumption was reduced from 1.3 with JP-4 fuel to 0.98 with pentaborane, a 13.2-percent reduction in net thrust was also encountered. A portion of this thrust loss is potentially recoverable with proper design of the engine components. The boron oxide deposition and erosion processes within the engine approached an equilibrium condition after approximately 22 minutes of operation with pentaborane.

Useller, James W↗

Acoustic Instabilities Driven by Slip Between a Condensed Phase and the Gas Phase in Combustion Systems

In the context of gas turbine combustion chambers, this study describes how slip affects the response time of fuel sprays to pressure fluctuations in a gaseous flow field. Slip between the condensed and gas phases is shown to cause fuel vapor mass fraction fluctuations upstream of the reaction zone. A resulting oscillating heat release can drive the pressure fluctuations, depending on the phase difference between them. This generates an acoustic instability. With relevance to previous experimental results, differences are explored in the evaporation characteristics among three different fuel sprays (JP-4, JP-5, and D-2) in relation to their effect on the magnitude of the fuel vapor mass fraction perturbations.

DiCicco, M.↗

Experimental Evaluation of Rocket Exhaust Diffusers for Altitude Simulation

An experimental investigation of exhaust diffusers has been conducted to evaluate various methods of minimizing the overall pressure ratio (from chamber to ambient pressure) required to establish and maintain full expansion of the nozzle flow (altitude simulation). Exhaust-diffuser configurations investigated were (1) cylindrical diffusers, (2) diffusers with contraction, and (3) diffusers including a right-angle turn. Cylindrical diffusers were evaluated with primary nozzles of various area ratios and types, as well as two clustered configurations; the other diffusers were evaluated with individual nozzles of constant area ratio and varied type. Air was the working fluid, except for two check points obtained with JP-4 fuel and liquid-oxygen rocket engines and cylindrical diffusers. The minimum length-diameter ratio of cylindrical diffusers was about 6 for minimum pressure-ratio requirements. With cylindrical diffusers of adequate length, the pressure-ratio requirements were primarily a function of the ratio of diffuser to nozzle-throat areas and were essentially independent of primary-nozzle type (including two clustered configurations) or area ratio. The two check points obtained with rocket engines indicated the pressure-ratio requirements at given ratios of diffuser to nozzle-throat areas were lowered, as compared with the requirements with air, as a result of the reduced ratio of specific heats. The minimum length-diameter ratio of the contraction throat of convergent-divergent diffusers was also about 6 for minimum pressure-ratio requirements. With adequate contraction-throat length, the pressure-ratio requirements of such diffusers were appreciably below those of comparable cylindrical diffusers when used with conical and cutoff-isentropic nozzles, but not when used with a bell nozzle. Minimum pressure-ratio requirements of a diffuser including a simple long-radius right-angle turn at maximum diffuser area, obtained with the center of radius of the turn a minimum of 2 diffuser diameters downstream of the nozzle exit, were not appreciably above those of a comparable optimum cylindrical diffuser. A diffuser including a long-radius right-angle turn at a contraction minimum area had somewhat lower pressure-ratio requirements than the aforementioned simple turn.

Sivo, Joseph N.↗