Search NASA⌕ Search

SEARCH · Search NASA

Results for “Kinetic Inductance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Overview of the Design, Fabrication and Performance Requirements of Micro-Spec, an Integrated Submillimeter Spectrometer

Micro-Spec is a compact submillimeter (350-700 GHz) spectrometer which uses low loss superconducting niobium microstrip transmission lines and a single-crystal silicon dielectric to integrate all of the components of a grating-analog spectrometer onto a single chip. Here we present details of the fabrication and design of a prototype Micro-Spec spectrometer with resolution, R64, where we use a high-yield single-flip wafer bonding process to realize instrument components on a 0.45 m single-crystal silicon dielectric. We discuss some of the electromagnetic design concerns (such as loss, stray-light, cross-talk, and fabrication tolerances) for each of the spectrometer components and their integration into the instrument as a whole. These components include a slot antenna with a silicon lens for optical coupling, a phase delay transmission line network, parallel plate waveguide interference region, and aluminum microstrip transmission line kinetic inductance detectors with extremely low cross-talk and immunity to stray light. We have demonstrated this prototype spectrometer with design resolution of R64. Given the optical performance of this prototype, we will also discuss the extension of this design to higher resolutions suitable for balloon-flight.

spectrometer↗

Heat Capacity and Thermal Conductance Measurements of a Superconducting-Normal Mixed State by Detection of Single 3 eV Photons in a Magnetic Penetration Thermometer

We report on measurements of the detected signal pulses in a molybdenum-gold Magnetic Penetration Thermometer (MPT) in response to absorption of one or more 3 eV photons. We designed and used this MPT sensor for x-ray microcalorimetry. In this device, the diamagnetic response of a superconducting MoAu bilayer is used to sense temperature changes in response to absorbed photons, and responsivity is enhanced by a Meissner transition in which the magnetic flux penetrating the sensor changes rapidly to minimize free energy in a mixed superconducting normal state. We have previously reported on use of our MPT to study a thermal phonon energy loss to the substrate when absorbing x-rays. We now describe results of extracting heat capacity C and thermal conductance G values from pulse height and decay time of MPT pulses generated by 3 eV photons. The variation in C and G at temperatures near the Meissner transition temperature (set by an internal magnetic bias field) allow us to probe the behavior in superconducting normal mixed state of the condensation energy and the electron cooling power resulting from quasi-particle recombination and phonon emission. The information gained on electron cooling power is also relevant to the operation of other superconducting detectors, such as Microwave Kinetic Inductance Detectors.

superconductivity↗

Optical Probe of the Superconducting Normal Mixed State in a Magnetic Penetration Thermometer

Using ultraviolet photon pulses, we have probed the internal behavior of a molybdenum-gold Magnetic Penetration Thermometer (MPT) that we designed for x-ray microcalorimetry. In this low-temperature detector, the diamagnetic response of a superconducting MoAu bilayer is used to sense temperature changes in response to absorbed photons. We have previously described an approximate model that explains the high responsivity of the detector to temperature changes as a consequence of a Meissner transition of the molybdenum-gold film in the magnetic field applied by the superconducting circuit used to bias the detector. We compare measurements of MPT heat capacity and thermal conductance, derived from UV photon pulse data, to our model predictions for the thermodynamic properties of the sensor and for the electron cooling obtained by quasiparticle recombination. Our data on electron cooling power is also relevant to the operation of other superconducting detectors, such as Microwave Kinetic Inductance Detectors.

superconductivity↗

The Impact of Standard Semiconductor Fabrication Processes on Polycrystalline Nb Thin Film Surfaces

Polycrystalline superconducting Nb thin films are extensively used for submillimeter and millimeter transmission line applications and, less commonly, used in microwave kinetic inductance detector (MKID) applications. The microwave and mm-wave loss in these films is impacted, in part, by the presence of surface nitrides and oxides. In this study, glancing incidence x-ray diffraction was used to identify the presence of niobium nitride and niobium monoxide surface layers on Nb thin films which had been exposed to chemicals used in standard photolithographic processing. A method of mitigating the presence of ordered niobium monoxide surface layers is presented. Furthermore, we discuss the possibility of using glancing incidence x-ray diffraction as a non-destructive diagnostic tool for evaluating the quality of Nb thin films used in MKIDs and transmission lines. For a given fabrication process, we have both the x-ray diffraction data of the surface chemistry and a measure of the mm-wave and microwave loss, the latter being made in superconducting resonators.

superconducting films↗

The Impact of Standard Semiconductor Fabrication Processes on Polycrystalline Nb Thin Film Surfaces

Polycrystalline Nb thin films are extensively used for microwave kinetic inductance detectors (MKIDs) and superconducting transmission line applications. The microwave and mm-wave loss in these films is impacted, in part, by the presence of surface nitrides and oxides. In this study, glancing incidence x-ray diffraction was used to identify the presence of niobium nitride and niobium monoxide surface layers on Nb thin films which had been exposed to chemicals used in standard photolithographic processing. A method of mitigating the presence of ordered niobium monoxide surface layers is presented. Furthermore, we discuss the possibility of using glancing incidence x-ray diffraction as a non-destructive diagnostic tool for evaluating the quality of Nb thin films used in MKIDs and transmission lines. For a given fabrication process, we have both the X-ray diffraction data of the surface chemistry and a measure of the mm-wave and microwave loss, the latter being made in superconducting resonators.

superconducting films↗

The Impact of Standard Semiconductor Fabrication Processes on Polycrystalline Nb Thin Film Surfaces

Polycrystalline Nb thin films are extensively used for microwave kinetic inductance detectors (MKIDs) and superconducting transmission line applications. The microwave and mm-wave loss in these films is impacted, in part, by the presence of surface nitrides and oxides. In this study, glancing incidence x-ray diffraction was used to identify the presence of niobium nitride and niobium monoxide surface layers on Nb thin films which had been exposed to chemicals used in standard photolithographic processing. A method of mitigating the presence of ordered niobium monoxide surface layers is presented. Furthermore, we discuss the possibility of using glancing incidence x-ray diffraction as a non-destructive diagnostic tool for evaluating the quality of Nb thin films used in MKIDs and transmission lines. For a given fabrication process, we have both the X-ray diffraction data of the surface chemistry and a measure of the mm-wave and microwave loss, the latter being made in superconducting resonators.

superconducting films↗

Superconducting Sensors for Microwave and Optical Photon-Starved Communications (Plenary)

NASA mission modeling indicates a desire for approximately a tenfold data improvement per decade from the Deep Space Network through the year 2040. Some of this improvement will come from aperture enhancement and antenna arraying, increased use of Ka-band over X-band, and high performance optical terminals (e.g. 12 m ground telescope). The remainder will depend on "disruptive" technologies. Deep-space communications differs from near earth communications. One way light travel times are measured in minutes rather than seconds and distances involved are large enough such that optical signals are photon limited and microwave signals have extremely low flux density. High frequency SQIF receivers and single photon detectors for optical communications will be described. Specifically, progress towards a "noiseless" receiver based on arrays of incommensurate area SQUIDs, and single photon counting detectors based on superconducting nanowires and kinetic inductance effects, will be discussed. Finally, the design of an optimal array of optical telescopes to emulate performance of a monolithic 12 m telescope will be outlined. In this case, optimal means minimizing the initial capital investment and operational cost while maintaining performance requirements of the deep-space link.

Romanofsky, Bob↗

Second-Generation Micro-Spec: A Compact Spectrometer for Far-Infrared and Submillimeter Space Missions

Micro-Spec is a direct-detection spectrometer which integrates all the components of a diffraction-grating spectrometer onto a ≈ 10-sq.cm chip through the use of superconducting microstrip transmission lines on a single- crystal silicon substrate. The second generation of Micro-Spec is being designed to operate with a spectral re- solution of at least 512 in the far-infrared and submillimeter (420–540 GHz, 714–555 μm) wavelength range, a band of interest for NASA's experiment for cryogenic large-aperture intensity mapping called EXCLAIM. EXCLAIM will be a balloon-borne telescope that is being designed to map the emission of redshifted carbon monoxide and singly-ionized carbon lines over a redshift range 0 < z < 3.5 and it will be the first demonstration of the Micro-Spec technology in a space-like environment. This work reviews the status of the Micro-Spec design for the EXCLAIM telescope, with emphasis on the spectrometer's two-dimensional diffractive region, through which light of different wavelengths is focused on kinetic inductance detectors along the instrument focal plane. An optimization process is used to generate a geometrical configuration of the diffractive region that satisfies l range and performance. An initial optical design optimized for n terms of geometric layout, spectral purity and efficiency.

Cataldo, Giuseppe↗

The Experiment for Cryogenic Large-Aperture Intensity Mapping (EXCLAIM)

The EXperiment for Cryogenic Large-Aperture Intensity Mapping (EXCLAIM) is a cryogenic balloon-borne instrument which will survey galaxy and star formation history over cosmological time scales. Rather than identifying individual objects, EXCLAIM will be a pathfinder to demonstrate an intensity mapping approach, which measures the cumulative redshifted line emission. EXCLAIM will operate at 420-540 GHz with a spectral resolution R=512 to measure the integrated CO and [CII] in redshift windows spanning \exclaimz. CO and [CII] line emissions are key tracers of the gas phases in the interstellar medium involved in star-formation processes. EXCLAIM will shed light on questions such as why the star formation rate declines at z < 2, despite continued clustering of the dark matter. The instrument will employ an array of six superconducting integrated grating-analog spectrometers (µ-Spec) coupled to microwave kinetic inductance detectors (MKIDs). Here we present an overview of the EXCLAIM instrument design and status.

Instrumentation and Photography↗

u-Spec Spectrometers for the EXCLAIM Instrument

The EXperiment for Cryogenic Large-aperture Intensity Mapping (EXCLAIM) is a cryogenic balloon-borne instrument that will map carbon monoxide and singly-ionized carbon emission lines across redshifts from 0to 3.5, using an intensity mapping approach. EXCLAIM will broaden our understanding of these elemental and molecular gases, and the role they play in star formation processes across cosmic time scales. The focal plane of EXCLAIM’s cryogenic telescope features sixμ-Spec spectrometers.μ-Spec is a compact, integrated grating-analog spectrometer, which uses meandered superconducting niobium microstrip transmission lines on a single-crystal silicon dielectric to synthesize the grating. It features superconducting aluminum microwave kinetic inductance detectors (MKIDs), also in a microstrip architecture. The spectrometers for EXCLAIM couple to the telescope optics via a hybrid planar antenna coupled to a silicon lenslet. The spectrometers operate from420−540 GHz with a resolving power R=λ/∆λ= 512, and employ an array of 355 MKIDs on each spectrometer. The spectrometer design targets a noise equivalent power (NEP) of 2×10−18W/√Hz (defined at the input to the main lobe of the spectrometer lenslet beam, within a 9◦half width), enabled by the cryogenic telescope environment, the sensitive MKID detectors, and the low dielectric loss of single-crystal silicon. We report on these spectrometers under development for EXCLAIM, providing an overview of the spectrometer and component designs, the spectrometer fabrication process, fabrication developments since previous prototype demonstrations, and the current status of their development for the EXCLAIM mission.

EXCLAIM Instrument↗

Optical Design of the EXperiment for Cryogenic Large-Aperture Intensity Mapping (EXCLAIM)

This work describes the optical design of the EXperiment for Cryogenic Large-Aperture Intensity Mapping(EXCLAIM). EXCLAIM is a balloon-borne telescope that will measure integrated line emission from carbonmonoxide (CO) at redshiftsz <1 and ionized carbon ([CII]) at redshiftsz= 2.5−3.5 to probe star forma-tion over cosmic time in cross-correlation with galaxy redshift surveys. The EXCLAIM instrument will observeat frequencies of 420–540 GHz using six microfabricated silicon integrated spectrometers with spectral resolv-ing powerR= 512 coupled to kinetic inductance detectors (KIDs). A completely cryogenic telescope cooledto a temperature below 5 K provides low-background observations between narrow atmospheric lines in thestratosphere. Off-axis reflective optics use a 90-cm primary mirror to provide 4.2′full-width at half-maximum(FWHM) resolution at the center of the EXCLAIM band over a field of view of 22.5′. Illumination of the 1.7 Kcold stop combined with blackened baffling at multiple places in the optical system ensures low (<−40 dB) edgeillumination of the primary to minimize spill onto warmer elements at the top of the dewar.

Thomas Essinger-Hileman↗

Far-infrared Imager and Polarimeter for the Origins Space Telescope

The far-infrared imager and polarimeter (FIP) for the Origins Space Telescope (Origins) is a basic far-infrared imager and polarimeter. The camera will deliver continuum images and polarization measurements at 50 and 250μm. Currently available detector technologies provide sufficient sensitivity for background limited observations from space, at least on a single pixel basis. FIP incorporates large next-generation superconducting detector arrays and our technology development plan will push the pixel numbers for the arrays to the required size of 8000. Two superconducting detector technologies are currently candidates for the instrument: transition edge sensors or microwave kinetic inductance devices. Using these detectors and taking advantage of the cryogenic telescope that is provided by Origins, FIP will achieve mapping speeds of up to eight orders of magnitude faster than what has been achieved by existing observatories. The science drivers for FIP include observations of solar system objects, dust properties, and magnetic field studies of the nearby interstellar medium, and large scale galaxy surveys to better constrain the star formation history of the universe to address one of the main themes of Origins: “How does the Universe work?” In addition to the science, the FIP instrument plays a critical functional role in aligning the mirrors during on orbit observatory commissioning.

Astronomy↗

EXCLAIM: A New Balloon Mission to Map the Cosmological History of Galaxies

The EXperiment for Cryogenic Large-Aperture Intensity Mapping (EXCLAIM) is a cryogenic balloon-borne instrument that will survey galaxy and star formation history over cosmological time scales. Rather than identifying individual objects, EXCLAIM will be a pathfinder to demonstrate an intensity mapping approach, which measures the cumulative redshifted line emission. EXCLAIM will operate at 420-540 GHz with a spectral resolution R=512 to measure the integrated CO and [CII] in redshift windows spanning 0 < z < 3.5. CO and [CII] line emissions are key tracers of the gas phases in the interstellar medium involved in star-formation processes. EXCLAIM will shed light on questions such as why the star formation rate declines at z < 2, despite continued clustering of the dark matter. The instrument will employ an array of six superconducting integrated grating-analog spectrometers (micro-spec) coupled to microwave kinetic inductance detectors (MKIDs). I will present an overview of the EXCLAIM instrument design and status.

Eric Switzer↗

The Experiment for Cryogenic Large-aperture Intensity Mapping (EXCLAIM)

Submillimeter and far-IR spectroscopy provides insight into galaxy evolution through measurement of atomic and molecular line emission. The EXperiment for Cryogenic Large-Aperture Intensity Mapping (EXCLAIM) is a cryogenic balloon-borne instrument designed to carry out intensity mapping to measure the cumulative redshifted line emission from carbon monoxide and singly-ionized carbon to probe star formation in windows from the present to z=3.5. During this time, the rate of star formation dropped dramatically, while dark matter continued to cluster. Intensity mapping permits a blind and complete survey of emitting gas through statistics of cumulative brightness fluctuations. EXCLAIM achieves high sensitivity using a cryogenic telescope coupled to six integrated spectrometers with spectral resolving power R=512 and employing microwave kinetic inductance detectors. Here we summarize the status of the mission.

Maryam Rahmani↗

The Experiment for Cryogenic Large-aperture Intensity Mapping (EXCLAIM)

Submillimeter and far-IR spectroscopy provides insight into galaxy evolution through atomic and molecular line emission. The EXperiment for Cryogenic Large-Aperture Intensity Mapping (EXCLAIM) is a cryogenic balloon-borne instrument designed to carry out an intensity mapping to measure the cumulative redshifted line emission from carbon monoxide and singly-ionized carbon to probe star formation in windows from the present to z=3.5. During this time, the rate of star formation dropped dramatically, while dark matter continued to cluster. Intensity mapping permits a blind and complete survey of emitting gas through statistics of cumulative brightness fluctuations. EXCLAIM achieves high sensitivity using a cryogenic telescope coupled to six integrated spectrometers with spectral resolving power R = 512 and employing kinetic inductance detectors. Here we summarize the status of the mission.

Maryam Rahmani↗

Low-Loss Thin-Film Al-On-Si Microwave Resonators for Astronomy Applications Designing and Characterizing the Next Generation of Microwave Detectors

We present measurements of prototype thin film Al microwave kinetic inductance detectors (MKIDs) intended for application in the sub-mm astronomy balloon experiment EXCLAIM. The device we show is dark, or non-optically coupled, and contains 16 coplanar waveguide (CPW) resonators etched into a 261 nm sputter deposited Al layer on a Si wafer. The resonators span the f0 = 3.5 - 4 GHz range, and include both lambda=2 and lambda=4 resonators. Each resonator is coupled to the feedline using one of three alternating coupling designs. We performed transmission line measurements of the device for a series of excitation powers ranging from -90 dBm to -30 dBm, and at a series of base temperatures ranging from 73 mK to 400 mK. We observed quality factors of up to Qi  107 at a base temperature of 73 mK. The lambda=2 and lambda=4 resonators performed similarly, achieving comparable Qi values. The results of these measurements are actively informing the fi nal design of the EXCLAIM instrument. EXCLAIM will incorporate six spectrometers, each containing an array of over 300 resonators in the 420-540 GHz range.

Carrie Volpert↗

Experiment for Cryogenic Large-Aperture Intensity Mapping: Instrument Design

The EXperiment for Cryogenic Large-Aperture Intensity Mapping (EXCLAIM) is a balloon-borne tele-33scope designed to survey star formation in windows from the present to z=3.5. During this time, the rate of star34formation dropped dramatically, while dark matter continued to cluster. EXCLAIM maps the redshifted emission35of singly-ionized carbon lines and carbon monoxide using intensity mapping, which permits a blind and complete36survey of emitting gas through statistics of cumulative brightness fluctuations. EXCLAIM achieves high sensitivity37using a cryogenic telescope coupled to six integrated spectrometers employing kinetic inductance detectors covering38420540GHz with spectral resolving power R=512and angular resolution⇡40. The spectral resolving power and39cryogenic telescope allow the survey to access dark windows in the spectrum of emission from the upper atmosphere.40EXCLAIM will survey305 deg2in the Sloan Digital Sky Survey Stripe 82 field from a conventional balloon flight41in 2023. EXCLAIM will also map several galactic fields to study carbon monoxide and neutral carbon emission as42tracers of molecular gas. Here, we summarize the design phase of the mission.

Eric R Switzer↗

Absorber Optimization Study for the Terahertz Intensity Mapper (TIM)

We discuss the design and optimization of the absorber for the long-wavelength arm of the Terahertz Intensity Mapper (TIM), a balloon-borne spectrometer employing Kinetic Inductance Detectors (KIDs). Electromagnetic simulations of our design indicate in-band absorption efficiency over 80% in both linear polarization modes. By developing custom transmission line model and mode-matching calculations, we find the absorption efficiency is affected by the absorber’s reactive part and overall shape. These insights into the operation of this design provide guidance for its optimization for low-resistance absorber. materials.

Nie, Rong↗