Search NASA⌕ Search

SEARCH · Search NASA

Results for “LABORATORY ANIMALS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Second-order Kinetics of DTPA and Plutonium in Rat Plasma

We report that in 2008, Serandour et al. reported on their in vitro experiment involving rat plasma samples obtained after an intravenous intake of plutonium citrate. Different amounts of DTPA were added to the plasma samples and the percentage of low-molecular-weight plutonium measured. Only when the DTPA dosage was three orders of magnitude greater than the recommended 30 μmol/kg was 100% of the plutonium apparently in the form of chelate. These data were modeled assuming three competing chemical reactions with other molecules that bind with plutonium. Here, time-dependent second-order kinetics of these reactions are calculated, intended eventually to become part of a complete biokinetic model of DTPA action on actinides in laboratory animals or humans. The probability distribution of the ratio of stability constants for the reactants was calculated using Markov Chain Monte Carlo. In conclusion, these calculations substantiate that the inclusion of more reactions is needed in order to be in agreement with known stability constants.

61 RADIATION PROTECTION AND DOSIMETRY↗

Proposed Occupational Exposure Limits for Furans

This report documents the re-evaluation of Hanford Tank Farm occupational exposure limits ( HTF OEL) for furan and 13 associated substituted furans identified as Chemicals of Potential Concern. Furan causes liver toxicity and cancer in laboratory animals. Recent toxicity studies in animal models have established a non-genotoxic mechanism of action and new data to support re-evaluation of the furan HTF OEL. As such, PNNL proposes to adjust the HTF OEL for furan from 1 ppb to 1.9 ppb based on a no-observed-adverse-effect level in Fischer-344 rats (the most sensitive species tested) exposed to subchronic oral administration of furan as a point of departure modified by species extrapolation of dose and route, inter- and intra-species uncertainty factors, and adjustments for life-time versus occupational exposure periods. Because of limited data and similar hypothesized mechanisms of toxicity, PNNL recommends continuing to use the furan HTF OEL as a surrogate for substituted furans until further data for substituted furans become available. Further toxicity investigations or new OELs proposed by authoritative organizations (e.g., National Institute of Occupational Safety and Health, Occupational Safety and Health Administration, and the American Conference of Government Industrial Hygienists) would warrant re-evaluation of HTF OEL for furan and substituted furans.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

Whole-Brain Mapping of Neuronal Activity in the Learned Helplessness Model of Depression

Some individuals are resilient, whereas others succumb to despair in repeated stressful situations. The neurobiological mechanisms underlying such divergent behavioral responses remain unclear. Here, we employed an automated method for mapping neuronal activity in search of signatures of stress responses in the entire mouse brain. We used serial two-photon tomography to detect expression of c-FosGFP – a marker of neuronal activation – in c-fosGFP transgenic mice subjected to the learned helplessness (LH) procedure, a widely used model of stress-induced depression-like phenotype in laboratory animals. We found that mice showing “helpless” behavior had an overall brain-wide reduction in the level of neuronal activation compared with mice showing “resilient” behavior, with the exception of a few brain areas, including the locus coeruleus, that were more activated in the helpless mice. In addition, the helpless mice showed a strong trend of having higher similarity in whole-brain activity profile among individuals, suggesting that helplessness is represented by a more stereotypic brain-wide activation pattern. This latter effect was confirmed in rats subjected to the LH procedure, using 2-deoxy-2[18F]fluoro-D-glucose positron emission tomography to assess neural activity. In conclusion, our findings reveal distinct brain activity markings that correlate with adaptive and maladaptive behavioral responses tostress, and provide a framework for further studies investigating the contribution of specific brain regions to maladaptive stress responses.

60 APPLIED LIFE SCIENCES↗

Comparison of a Micro-Neutralization Test with the Rapid Fluorescent Focus Inhibition Test for Measuring Rabies Virus Neutralizing Antibodies

The rapid fluorescent focus inhibition test (RFFIT) is routinely used in the United States to measure rabies virus neutralizing antibodies (rVNA). RFFIT has a long history of reproducible and reliable results. The test has been modified over the years to use smaller volumes of reagents and samples, but requires a 50 µL minimum volume of test serum. To conduct pathogenesis studies, small laboratory animals such as mice are regularly tested for rVNA, but the minimum volume for a standard RFFIT may be impossible to obtain, particularly in scenarios of repeated sampling. To address this problem, a micro-neutralization test was developed previously. In the current study, the micro-neutralization test was compared to the RFFIT using 129 mouse serum samples from rabies vaccine studies. Using a cut-off value of 0.1 IU/mL, the sensitivity, specificity, and concordance of the micro-neutralization test were 100%, 97.5%, and 98%, respectively. The geometric mean titer of all samples above the cut-off was 2.0 IU/mL using RFFIT and 3.4 IU/mL using the micro-neutralization test, indicating that titers determined using the micro-neutralization test are not equivalent to RFFIT titers. Based on four rVNA-positive hamster serum samples, the intra-assay coefficient of variability was 24% and inter-assay coefficient of variability was 30.4%. These results support continued use of the micro-neutralization test to determine rabies virus neutralizing antibody titers for low-volume serum samples.

59 BASIC BIOLOGICAL SCIENCES↗

Trihalomethanes in Comerio Drinking Water and Their Reduction by Nanostructured Materials

The formation of disinfection by-products (DBPs) during chlorination of drinking water is an issue which has drawn significant scientific attention due to the possible adverse effects that these compounds have on human health and the formation of another DBPs. Some factors that affect the formation of DBPs include: chlorine dose and residue, contact time, temperature, pH and natural organic matter (NOM). The most frequently detected DBPs in drinking water are trihalomethanes (THMs) and haloacetic acids (HAAs). The MCLs are standards established by the United States Environmental Protection Agency (USEPA) for drinking water quality established in Stage 1, Disinfectants and Disinfection Byproducts Rule (DBPR), and they limit the amount of potentially hazardous substances that are allowed in drinking water. The water quality data for THMs were evaluated in the Puerto Rico Aqueduct and Sewer Authority (PRASA). During this evaluation, the THMs exceeded the maximum contamination limit (MCLs) for the Comerio Water Treatment Plant (CWTP). USEPA classified the THMs as Group B2 carcinogens (shown to cause cancer in laboratory animals). This research evaluated the THMs concentrations in the following sampling sites: CWTP, Río Hondo and Piñas Abajo schools, Comerio Health Center (CDT), and the Vázquez Ortiz family, in the municipality of Comerio Puerto Rcio. The results show that the factors affecting the formation of THMs occur in different concentrations across the distribution line. Furthermore, there are not specific ranges to determine the formation of THMs in drinking water when the chemical and physical parameters were evaluated. Three different nanostructured materials (graphene, mordenite (MOR) and multiwalled carbon nanotubes (MWCNTs)) were used in this research, to reduce the THMs formation by adsorption in specific contact times. The results showed that graphene is the best nanomaterial to reduce THMs in drinking water. Graphene can reduce 80 parts per billion (ppb) of THMs in about 2 hours. In addition mordenite can reduce approximately 80 ppb of THMs and MWCNTs adsorbs 71 ppb of THMs in the same period of time respectively. Finally, in order to complement the adsorption results previously obtained, total organic carbon (TOC) analyses were measured, after different contact times with the nanomaterials.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Decontamination and Management of Human Remains Following Incidents of Hazardous Chemical Release

Abstract Objective: To provide specific procedural guidance and resources for identification, assessment, control, and mitigation of compounds that may contaminate human remains resulting from chemical attack or release. Design: A detailed technical, policy, and regulatory review is summarized. Setting: Guidance is suitable for civilian or military settings where human remains potentially contaminated with hazardous chemicals may be present. Settings would include sites of transportation accidents, natural disasters, terrorist or military operations, mortuary affairs or medical examiner processing and decontamination points, and similar. Patients, Participants: While recommended procedures have not been validated with actual human remains, guidance has been developed from data characterizing controlled experiments with fabrics, materiel, and laboratory animals. Main Outcome Measure(s): Presentation of logic and specific procedures for remains management, protection and decontamination of mortuary affairs personnel, as well as decision criteria for determining when remains are sufficiently decontaminated so as to pose no chemical health hazard. Results: Established procedures and existing equipment/materiel available for decontamination and verification provide appropriate and reasonable means to mitigate chemical hazards from remains. Extensive characterization of issues related to remains decontamination indicates that supra-lethal concentrations of liquid chemical warfare agent VX may prove difficult to decontaminate and verify in a timely fashion. Specialized personnel can and should be called upon to assist with monitoring necessary to clear decontaminated remains for transport and processing. Conclusions: Once appropriate decontamination and verification have been accomplished, normal procedures for remains processing and transport to the decedent s family and the continental United States can be followed.

99 GENERAL AND MISCELLANEOUS↗

Miniature bioelectric device accurately measures and telemeters temperature

Miniature micropower solid-state circuit measures and telemeters the body temperature of laboratory animals over periods up to two years. The circuit employs a thermistor as a temperature sensing element and an fm transmitter. It is constructed from conventional discrete components or integrated circuits.

Fryer, T. B.↗

Miniature biotelemeter giving 10 channels of wideband biomedical data.

A miniature biotelemeter has been developed for sensing and transmitting multiple channels of wideband biomedical data over a radio link. Its small size and weight make it capable of being carried by free-moving laboratory animals as small as rats. Ten data channels each of 5-kHz data bandwidth are provided to permit monitoring of a wide variety of physiological signals. Multichannel telemetry of electroencephalograms, electrocardiograms, electromyograms, state functions, and dynamic processes such as blood flow and body chemistry are possible applications. Utilization of newly available monolithic chip components, low-power COS/MOS MSI digital logic, and state-of-the-art hybrid mounting techniques makes this novel device useful for both research and clinical bioinstrumentation.

Carraway, J.↗

Microbiological and experimental-histological investigations of lunar samples returned by the Lunar 16 automatic station

Lunar surface material was studied for its content of viable microorganisms (aerobic and anaerobic, fungi, and viruses); the effect of the lunar surface material on the growth of microorganisms and its interaction with somatic cells of mammals was also observed. No viable microorganisms were detected; the samples exhibited neither stimulant or inhibitory action on the growth of microorganisms, and also showed no cytopathogenic action on tissue cultures. A suspension of lunar surface material particles was not toxic when parenterally administered to certain laboratory animals. The particles were subjected to intense phagocytosis by connective tissue cells in vivo and in vitro.

Kaulen, D. R.↗

Fluid infusion system

Performance testing carried out in the development of the prototype zero-g fluid infusion system is described and summarized. Engineering tests were performed in the course of development, both on the original breadboard device and on the prototype system. This testing was aimed at establishing baseline system performance parameters and facilitating improvements. Acceptance testing was then performed on the prototype system to verify functional performance. Acceptance testing included a demonstration of the fluid infusion system on a laboratory animal.

Source record↗

Stress, temperature, heart rate, and hibernating factors in hamsters

Pathophysiological conditions resulting from prolonged exposure to zero gravity, cabin constraint, altered ambient environment, whether it be noise, vibrations, high temperatures, or combinations of such factors, are studied in laboratory animals and applied to manned space flight. Results and plans for further study are presented. Specific topics covered include: thermoregulation and its role in reflecting stress and adaptation to the gravity free environment and cabin confinement with its altered circadian forcings; renal function and its measurement in electrolyte distribution and blood flow dynamics; gastronintestinal function and an assessment of altered absorptive capacity in the intestinal mucosa; and catecholamine metabolism in terms of distribution and turnover rates in specific tissues.

Musacchia, X. J.↗

Relative toxicity of pyrolysis products of some foams and fabrics

A limited number of foams and fabrics was evaluated in the course of developing test procedures for determining the relative toxicity of materials. The principal variable studied, heating rate, did not affect the relative ranking of the materials tested. Two pyrolysis test procedures using the same basic approach but employing different sample weights, chamber volumes, laboratory animals, heating rates, and upper temperature limits, resulted in identical rankings of relative toxicity. The data obtained show that modification of conventional flexible polyurethane foams with flame retardants to comply with California upholstered furniture flammability regulations seems to consistently reduce toxicity under pyrolysis conditions.

Hilado, C. J.↗

Evaluation of the smoke density chamber as an apparatus for fire toxicity screening tests

The smoke density chamber is perhaps the most widely used apparatus for smoke measurements. Because of its availability, it has been proposed as an apparatus for evaluating fire toxicity. The standard apparatus and procedure were not found suitable for toxicity screening tests using laboratory animals, because not enough materials of interest produced animal mortality or even incapacitation under standard test conditions. With modifications, the chamber offers greater promise as a screening tool, but other tests specifically designed to measure relative toxicity may be more cost-effective. Where one-dimensional heat flux is a requirement, the chamber is the most suitable apparatus available. It should be improved in regard to visibility of animals and ease of cleaning.

Hilado, C. J.↗

Dual-purpose laboratory cage/antenna

Part of steel cage enclosing laboratory animals is used as an antenna to transmit biotelemetry over short distances. Receiving and signal processing equipment are located above ground potential to avoid transmission-path difficulties.

Lalande, B. H.↗

Batteryless implanted echosonometer

Miniature ultrasonic echosonometer implanted within laboratory animals obtains energy from RF power oscillator that is electronically transduced via induction loop to power receiving loop located just under animal's skin. Method of powering device offers significant advantages over those in which battery is part of implanted package.

Kojima, G. K.↗

Concepts in health evaluation of commercial and industrial chemicals

A method is described for determining no toxic effect exposure levels based on short-term testing of industrial and commercial chemicals. Procedures for monitoring all organs and body functions for the presence or absence of toxicological effects are demonstrated using various laboratory animals.

Mcnamara, B. P.↗

SMD 3 post test medical report

One of several reports that were prepared to document the results of the Spacelab Mission Development Test 3 is presented. This report covers clinical support to the crew as well as assistance and counsel to others in crew selection, health stabilization of the crew and the laboratory animals, and habitability and duty schedules.

Hordinsky, J. R.↗