Search NASA⌕ Search

SEARCH · Search NASA

Results for “LABORATORY EQUIPMENT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

To automate or not to automate : this is the question.

New protocols and instrumentation significantly boost the outcome of structural biology, which has resulted in significant growth in the number of deposited Protein Data Bank structures. However, even an enormous increase of the productivity of a single step of the structure determination process may not significantly shorten the time between clone and deposition or publication. For example, in a medium size laboratory equipped with the LabDB and HKL-3000 systems, we show that automation of some (and integration of all) steps of the X-ray structure determination pathway is critical for laboratory productivity. Moreover, we show that the lag period after which the impact of a technology change is observed is longer than expected.

59 BASIC BIOLOGICAL SCIENCES↗

Smartphone-Based Device for Colorimetric Detection of MicroRNA Biomarkers Using Nanoparticle-Based Assay

The detection of microRNAs (miRNAs) is emerging as a clinically important tool for the non-invasive detection of a wide variety of diseases ranging from cancers and cardiovascular illnesses to infectious diseases. Over the years, miRNA detection schemes have become accessible to clinicians, but they still require sophisticated and bulky laboratory equipment and trained personnel to operate. The exceptional computing ability and ease of use of modern smartphones coupled with fieldable optical detection technologies can provide a useful and portable alternative to these laboratory systems. Herein, we present the development of a smartphone-based device called Krometriks, which is capable of simple and rapid colorimetric detection of microRNA (miRNAs) using a nanoparticle-based assay. The device consists of a smartphone, a 3D printed accessory, and a custom-built dedicated mobile app. We illustrate the utility of Krometriks for the detection of an important miRNA disease biomarker, miR-21, using a nanoplasmonics-based assay developed by our group. We show that Krometriks can detect miRNA down to nanomolar concentrations with detection results comparable to a laboratory-based benchtop spectrophotometer. With slight changes to the accessory design, Krometriks can be made compatible with different types of smartphone models and specifications. Thus, the Krometriks device offers a practical colorimetric platform that has the potential to provide accessible and affordable miRNA diagnostics for point-of-care and field applications in low-resource settings.

Krishnan, Tushar (ORCID:0000000342610336)↗

Establishing ZIF‐8 as a reference material for hydrogen cryoadsorption: An interlaboratory study

Abstract Hydrogen storage by cryoadsorption on porous materials has the advantages of low material cost, safety, fast kinetics, and high cyclic stability. The further development of this technology requires reliable data on the H 2 uptake of the adsorbents, however, even for activated carbons the values between different laboratories show sometimes large discrepancies. So far no reference material for hydrogen cryoadsorption is available. The metal‐organic framework ZIF‐8 is an ideal material possessing high thermal, chemical, and mechanical stability that reduces degradation during handling and activation. Here, we distributed ZIF‐8 pellets synthesized by extrusion to 9 laboratories equipped with 15 different experimental setups including gravimetric and volumetric analyzers. The gravimetric H 2 uptake of the pellets was measured at 77 K and up to 100 bar showing a high reproducibility between the different laboratories, with a small relative standard deviation of 3–4 % between pressures of 10–100 bar. The effect of operating variables like the amount of sample or analysis temperature was evaluated, remarking the calibration of devices and other correction procedures as the most significant deviation sources. Overall, the reproducible hydrogen cryoadsorption measurements indicate the robustness of the ZIF‐8 pellets, which we want to propose as a reference material.

08 HYDROGEN↗

Design and application of a mobile ground-based observatory for continuous measurements of atmospheric trace gas and criteria pollutant species

Ground-based measurements of atmospheric trace gas species and criteria pollutants are essential for understanding emissions dynamics across space and time. Gas composition in the lower 50 m of the atmosphere has the greatest direct impacts on human health as well as ecosystem processes; hence data at this level are necessary for addressing carbon-cycle- and public-health-related questions. However, such surface data are generally associated with stationary measurement towers, where spatial representation is limited due to the high cost of establishing and maintaining an extensive network of measurement stations. We describe here a compact mobile laboratory equipped to provide high-precision, high-frequency, continuous, on-road synchronous measurements of CO 2 , CO, CH 4 , H 2 O, NO x , O 3 , aerosol, meteorological, and geospatial position data. The mobile laboratory has been deployed across the western USA. In addition to describing the vehicle and its capacity, we present data that illustrate the use of the laboratory as a powerful tool for investigating the spatial structure of urban trace gas emissions and criteria pollutants at spatial scales ranging from single streets to whole ecosystem and regional scales. We assess the magnitude of known point sources of CH 4 and also identify fugitive urban CH 4 emissions. We illustrate how such a mobile laboratory can be used to better understand emissions dynamics and quantify emissions ratios associated with trace gas emissions from wildfire incidents. Lastly, we discuss additional mobile laboratory applications in health and urban metabolism.

Bush, S. E.↗

Light Water Reactor Sustainability Program: Complete Report on Development of Weld Repair Technology

This report summarizes recent post-welding activities on irradiated alloys at the Irradiated Materials Examination and Testing (IMET) and the Low Activation Materials Development and Analysis (LAMDA) facilities at Oak Ridge National Laboratory. Equipment and capabilities were developed jointly by the U.S. Department of Energy, Office of Nuclear Energy, Light Water Reactor Sustainability Program, the Electric Power Research Institute, Long Term Operations Program (and the Welding and Repair Technology Center), and Oak Ridge National Laboratory. The preliminary helium measurements and microstructure characterization revealed successful advanced laser and friction stir welding procedures on high helium content stainless steel. The significant, on-going effort to weld irradiated alloys with high helium concentrations and comprehensively analyze the results will eventually yield validated repair techniques and guidelines for use by the nuclear industry in extending the operational lifetimes of nuclear power plants. The nuclear industry welding workshop was successfully held at ORNL on September 18 – 19, 2018.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Project LASER

NASA formally launched Project LASER (Learning About Science, Engineering and Research) in March 1990, a program designed to help teachers improve science and mathematics education and to provide 'hands on' experiences. It featured the first LASER Mobile Teacher Resource Center (MTRC), is designed to reach educators all over the nation. NASA hopes to operate several MTRCs with funds provided by private industry. The mobile unit is a 22-ton tractor-trailer stocked with NASA educational publications and outfitted with six work stations. Each work station, which can accommodate two teachers at a time, has a computer providing access to NASA Spacelink. Each also has video recorders and photocopy/photographic equipment for the teacher's use. MTRC is only one of the five major elements within LASER. The others are: a Space Technology Course, to promote integration of space science studies with traditional courses; the Volunteer Databank, in which NASA employees are encouraged to volunteer as tutors, instructors, etc; Mobile Discovery Laboratories that will carry simple laboratory equipment and computers to provide hands-on activities for students and demonstrations of classroom activities for teachers; and the Public Library Science Program which will present library based science and math programs.

Source record↗

Condensation Processes in Astrophysical Environments

Astrophysical systems present an intriguing set of challenges for laboratory chemists. Chemistry occurs in regions considered an excellent vacuum by laboratory standards and at temperatures that would vaporize laboratory equipment. Outflows around Asymptotic Giant Branch (AGB) stars have timescales ranging from seconds to weeks depending on the distance of the region of interest from the star and, on the way significant changes in the state variables are defined. The atmospheres in normal stars may only change significantly on several billion-year timescales. Most laboratory experiments carried out to understand astrophysical processes are not done at conditions that perfectly match the natural suite of state variables or timescales appropriate for natural conditions. Experimenters must make use of simple analog experiments that place limits on the behavior of natural systems, often extrapolating to lower-pressure and/or higher-temperature environments. Nevertheless, we argue that well-conceived experiments will often provide insights into astrophysical processes that are impossible to obtain through models or observations. This is especially true for complex chemical phenomena such as the formation and metamorphism of refractory grains under a range of astrophysical conditions. Data obtained in our laboratory has been surprising in numerous ways, ranging from the composition of the condensates to the thermal evolution of their spectral properties. None of this information could have been predicted from first principals and would not have been credible even if it had.

Nuth, Joseph A., III↗

Systems integration for the Kennedy Space Center (KSC) Robotics Applications Development Laboratory (RADL)

A laboratory for developing robotics technology for hazardous and repetitive Shuttle and payload processing activities is discussed. An overview of the computer hardware and software responsible for integrating the laboratory systems is given. The center's anthropomorphic robot is placed on a track allowing it to be moved to different stations. Various aspects of the laboratory equipment are described, including industrial robot arm control, smart systems integration, the supervisory computer, programmable process controller, real-time tracking controller, image processing hardware, and control display graphics. Topics of research include: automated loading and unloading of hypergolics for space vehicles and payloads; the use of mobile robotics for security, fire fighting, and hazardous spill operations; nondestructive testing for SRB joint and seal verification; Shuttle Orbiter radiator damage inspection; and Orbiter contour measurements. The possibility of expanding the laboratory in the future is examined.

Davis, V. Leon↗

Geospatial Education and Research Development: A Laboratory for Remote Sensing and Environmental Analysis (LaRSEA)

Old Dominion University has claimed the title "University of the 21st Century," with a bold emphasis on technology innovation and application. In keeping with this claim, the proposed work has implemented a new laboratory equipped for remote sensing as well as curriculum and research innovations afforded for present and future faculty and students. The developments summarized within this report would not have been possible without the support of the NASA grant and significant cost-sharing of several units within the University. The grant effectively spring-boarded the university into major improvements in its approach to remote sensing and geospatial information technologies. The university has now committed to licensing Erdas Imagine software for the laboratory, a campus-wide ESRI geographic information system (GIS) products license, and several smaller software and hardware utilities available to faculty and students through the laboratory. Campus beneficiaries of this grant have included faculty from departments including Ocean, Earth. and Atmospheric Sciences, Political Science and Geography, Ecological Sciences, Environmental Health, and Civil and Environmental Engineering. High student interest is evidenced in students in geology, geography, ecology, urban studies, and planning. Three new courses have been added to the catalog and offered this year. Cross-cutting curriculum changes are in place with growing enrollments in remote sensing, GIS, and a new co-taught seminar in applied coastal remote sensing. The enabling grant has also allowed project participants to attract external funding for research grants, thereby providing additional funds beyond the planned matching, maintenance and growth of software and hardware, and stipends for student assistants. Two undergraduate assistants and two graduate assistants have been employed by full-time assistantships as a result. A new certificate is offered to students completing an interdisciplinary course sequence in remote sensing and coastal environments. Subsequent phases of the project are under planning. including seminars for regional coastal managers and public dissemination of remote sensing science through the local media and university publications.

Allen, Thomas R., Jr.↗

Permanent Magnet Synchronous Motors for Commercial Refrigeration (Final Report)

This report provides background information on various fractional-horsepower electric motor technologies used for evaporator fan applications in commercial refrigeration and summarizes data from a DOE-sponsored evaporator fan motor laboratory and field demonstration project. This report also extrapolates that data to project the potential economic and environmental benefits resulting from upgrading the current installed base of commercial refrigeration evaporator fan motors to permanent magnet synchronous (PMS) motors.Evaporator fan motors used in commercial refrigeration applications are fractional horsepower in size, responsible for moving air across the evaporator coil, and typically run at one speed. Historically, shaded-pole induction motors have been the most commonly used evaporator fan motors in commercial refrigeration equipment and beverage vending machines. These are the simplest and least expensive type of fractional-horsepower motor, with an efficiency of approximately 20%. Electronically commutated (EC) permanent magnet motors, also known as brushless DC motors, were initially commercialized in the late 1980s, and their use in commercial refrigeration applications has increased within the last 10 to 15 years because of economic incentives and regulatory requirements. State-of-the-art EC motors are approximately 66% efficient. Another induction motor type, the permanent split capacitor (PSC) motor, offers a mid-point between shaded-pole and EC motor price and efficiency levels. PSC motors are typically about 29% efficient.A permanent magnet synchronous (PMS) AC motor that can directly use grid-supplied AC current without the need to rectify to DC has recently been commercialized. This new motor exhibits a peak efficiency of 75% and has the potential to significantly reduce the energy consumption of evaporator fan motors in commercial refrigeration equipment. Laboratory evaluation of evaporator fan motor technologies was performed to quantify and compare the performance of shaded-pole, PSC, EC, and PMS evaporator fan motors in a controlled environment, so as to minimize the influence of external factors and anomalies. The laboratory evaluation included dynamometer testing of the fan motors and airflow testing of the motor/fan assemblies. It was found that the 6–12 W PMS motor exhibited a peak efficiency of 75% with a power factor of approximately 0.9 at a power output of 11 W. It was also found that a 38–50 W PMS motor exhibited a peak efficiency of 82% with a power factor of approximately 0.9 at a power output of 35 W.Airflow testing of shaded-pole, PSC, EC, and PMS motor/fan assemblies was performed using an airflow test chamber, which was designed in accordance with ANSI/AMCA Standard 210-16/ASHRAE Standard 51-16, to measure the performance of the subject motor/fan assembly and to determine the incumbent display case system impedance (AMCA 2016). A family of fan curves (static pressure vs airflow rate and electrical power input vs airflow rate) was generated for the 6–12 W PMS motor/fan assemblies with 8-inch fan blades pitched from 17 to 32 degrees. A similar set of curves was generated for the 38–50 W motors paired with 10 and 12-inch blades. Various incumbent motor/fan assemblies were also tested in the laboratory airflow test chamber and their fan curves were generated.Field evaluation of refrigerated display case evaporator fan motors was accomplished by performing side-by-side comparisons of 6–12 W PMS motors to 6–12 W shaded-pole and EC evaporator fan motors. It was found that, on average, a PMS motor consumes 79% less power and draws 82% less current than a shaded pole motor, and on average, 34% less power and 49% less current than an EC motor. In addition, the PMS motor exhibits an average power factor of approximately 0.82, which is on average 40% greater than that of existing evaporator fan motors.Two field test sites were selected to evaluate the performance of the larger 38 to 50 W PMS evaporator fan motors in walk-in cooler/freezer applications. At each supermarket, two walk-in units were selected for investigation: one walk-in dairy cooler and one walk-in freezer. A 61% decrease in fan motor power was measured when retrofitting existing evaporator fan motors with PMS motors in the walk-in cooler. In addition, a 48% decrease in fan motor power was measured when retrofitting existing evaporator fan motors with PMS motors in the walk-in freezer.The culmination of the field evaluation of fan motor technologies was a whole-store retrofit conducted at a supermarket. Pre- and post-retrofit measurement of evaporator fan motor power in medium- and low-temperature refrigerated display cases and walk-in coolers/freezers was performed. Overall for the whole-store retrofit, the current supplied to all monitored evaporator fan motors was reduced by 52%, the real power was reduced by 46% and the apparent power was reduced by 51% following the retrofit of the 262 evaporator fan motors that w

42 ENGINEERING↗

Precise calibration of Mg concentration in Mg{sub x}Zn{sub 1-x}O thin films grown on ZnO substrates

The growth techniques for Mg{sub x}Zn{sub 1-x}O thin films have advanced at a rapid pace in recent years, enabling the application of this material to a wide range of optical and electrical applications. In designing structures and optimizing device performances, it is crucial that the Mg content of the alloy be controllable and precisely determined. In this study, we have established laboratory-based methods to determine the Mg content of Mg{sub x}Zn{sub 1-x}O thin films grown on ZnO substrates, ranging from the solubility limit of x {approx} 0.4 to the dilute limit of x < 0.01. For the absolute determination of Mg content, Rutherford backscattering spectroscopy is used for the high Mg region above x = 0.14, while secondary ion mass spectroscopy is employed to quantify low Mg content. As a lab-based method to determine the Mg content, c-axis length is measured by x-ray diffraction and is well associated with Mg content. The interpolation enables the determination of Mg content to x = 0.023, where the peak from the ZnO substrate overlaps the Mg{sub x}Zn{sub 1-x}O peak in standard laboratory equipment, and thus limits quantitative determination. At dilute Mg contents below x = 0.023, the localized exciton peak energy of the Mg{sub x}Zn{sub 1-x}O films as measured by photoluminescence is found to show a linear Mg content dependence, which is well resolved from the free exciton peak of ZnO substrate down to x = 0.0043. Our results demonstrate that x-ray diffraction and photoluminescence in combination are appropriate methods to determine Mg content in a wide Mg range from x = 0.004 to 0.40 in a laboratory environment.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

A 3D-Printed, Portable, Optical-Sensing Platform for Smartphones Capable of Detecting the Herbicide 2,4-Dichlorophenoxyacetic Acid

Onsite rapid detection of herbicide and herbicide residuals in environmental and biological specimens is important for agriculture, environment, food safety, and health care. Traditional method for herbicide detection requires expensive laboratory equipment and a long turn-round time. In this work, we developed a single-stripe microliter plate smartphone colorimetric device for rapid and low-cost in-field test. This portable smartphone platform is capable of screening 8 samples in a microplate single-stripe. The device combined the advantages of small size (50×100×160 mm3) and low cost ($10). The platform was calibrated by using two different dye solutions, i.e. methyl blue (MB) and Rhodamine B, for green and red channels. The results showed good correlation with results attained from a traditional laboratory reader. We demonstrated the application of this platform for an herbicide, 2,4-Dichlorophenoxyacetic acid detection in the range of 1 ppb to 80 ppb. Spiked samples of tap water, rat serum, plasma and human serum were tested by our device. Recoveries obtained varied from 95.6% to 105.2% for all spiked samples using the microplate reader and from 93.7% to 106.9% using the smartphone device. This work validated that the smartphone optical sensing platform is comparable to the commercial microplate reader, it is eligible for onsite rapid and low-cost detection of herbicide for environmental evaluation and biological monitoring.

Wang, Yijia↗

Noise Level Hazards due to Agricultural Equipment in a Laboratory

Noise exposure is a common health hazard in the agricultural field due to the continuous use of large pieces of equipment. In lab settings it is not as common to noise exposure due to industrial scale equipment. However, the energy system laboratories at INL are exploring new and inventive ways to create energy from biomaterials. This process requires the use of large pieces of agricultural equipment such as hammer mills, shakers, conveyor belts, etc. As the researchers continuously refine this process, they not only test the limits of renewable resources for energy but also test the noise exposure threshold limits. The purpose of this project was to determine the noise level hazards which are present due to the use of large agricultural equipment in a laboratory setting.

99 GENERAL AND MISCELLANEOUS↗

An Extended Study on the Uncertainty Quantification of a Photodiode's Spectral Responsivity

An extended study was done on the analysis procedure for spectral responsivity of a silicon detector from the range of 200 nm to 1100 nm for the Optical Component Calibration laboratory at Livermore Operations in Livermore California. As a result, the uncertainty of the procedure was quantified to account for variables that contribute to uncertainty; such as the reproducibility and repeatability of the working standards, quantifying Type A and B uncertainties, validating laboratory equipment and associated software, and looking at environmental variables. The findings lead to a revised analysis reporting procedure that reports uncertainties depending on three spectral ranges, 300 nm to 400 nm, 400 nm to 700 nm, and 700 nm to 1100 nm. A proficiency test was done to compare the difference between both methods and a noticeable difference was found. The results showed that the previous reporting method over estimated uncertainty as much as 3.5% for the 300 nm to 400 nm range, 4% in the >400 nm to 700 nm range, and 2% in the >700 nm to 1100 nm range. The findings lead to the use of the revised procedure when producing calibration certificates, better quantified measurement uncertainties, and will be used for the process of updating the scope of accreditation from the National Voluntary Laboratory Accreditation Program.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Tank Waste Characterization: History, Challenges, and Success Stories

The preparation and chemical and radiochemical analysis of Hanford tank waste samples can be performed with standard laboratory equipment and instruments as relatively routine processes that are not particularly challenging. Rather, the main challenges of tank waste characterization are associated with radiological dose and sampling limitations. Accurate, representative and effective sampling techniques are difficult with the waste tanks because they were not designed for routine sampling. There are a finite number of sampling locations for each tank based on riser positioning, depth and the operational functionality of the sampling riser. For example, in one recently emptied SST, there was one riser that was found to have had concrete dumped down it, thereby eliminating that sampling port. Additionally, the waste within the tank; especially true for the saltcake and sludge, is not homogenous. The ability to adequately mix a million-gallon double shell tank (DST) is a concern for data reproducibility. Another real challenge that must be addressed for sampling single shell tanks, is how to dissolve the salt cake waste in a compromised (leaking) SST. These physical constraints mean that uncertainty in the representativeness of samples must be considered when applying analytical results to the bulk contents of the tank. The tank waste is highly radioactive and thus can only be handled initially by facilities that can receive samples into concrete-shielded hot cells with remote operation with an example provided in Figure 1. The shielding protects the worker from the radiological dose while mineral oil windows and remotely operated manipulators enables the samples to be handled. At Hanford, analytical laboratories with these hot cell capabilities are limited to the Pacific Northwest National Laboratory and the main Hanford operations support laboratory, 222-S Laboratory. Because of their highly radioactive nature, samples must be sufficiently diluted to facilitate their analysis outside of a shielded cell. In some cases, this means some accuracy must be compromised to complete the analysis beyond that normally encountered for non-radioactive material.

Waste Characterization, BBI, PHOENIX: Tank Farms: ↗

A thioacidolysis method tailored for higher‐throughput quantitative analysis of lignin monomers

Abstract Thioacidolysis is a method used to measure the relative content of lignin monomers bound by β‐O‐4 linkages. Current thioacidolysis methods are low‐throughput as they require tedious steps for reaction product concentration prior to analysis using standard GC methods. A quantitative thioacidolysis method that is accessible with general laboratory equipment and uses a non‐chlorinated organic solvent and is tailored for higher‐throughput analysis is reported. The method utilizes lignin arylglycerol monomer standards for calibration, requires 1–2 mg of biomass per assay and has been quantified using fast‐GC techniques including a Low Thermal Mass Modular Accelerated Column Heater (LTM MACH). Cumbersome steps, including standard purification, sample concentrating and drying have been eliminated to help aid in consecutive day‐to‐day analyses needed to sustain a high sample throughput for large screening experiments without the loss of quantitation accuracy. The method reported in this manuscript has been quantitatively validated against a commonly used thioacidolysis method and across two different research sites with three common biomass varieties to represent hardwoods, softwoods, and grasses.

09 BIOMASS FUELS↗

Laboratory Enrichment of Radioactive Assemblages and Estimation of Thorium and Uranium Radioactivity in Fractions Separated from Placer Sands in Southeast Bangladesh

The present study reports the likely first attempt of separating radioactive minerals for estimation of activity concentration in the beach placer sands of Bangladesh. Several sand samples from heavy mineral deposits located at the south-eastern coastal belt of Bangladesh were processed to physically upgrade their radioactivity concentrations using plant and laboratory equipment. Following some modified flow procedure, individual fractions were separated and investigated using gamma-ray spectrometry and powder-XRD analysis. The radioactivity measurements indicated contributions of the thorium and uranium radioactive series and of {sup 40}K. The maximum values of {sup 232}Th and {sup 238}U, estimated from the radioactivity of {sup 208}Tl and {sup 234}Th in secular equilibrium, were found to be 152,000 and 63,300 Bq/kg, respectively. The fraction of the moderately conductive part in electric separation contained thorium predominantly, while that of the non-conductive part was found to be uranium rich. The present arrangement of the pilot plant cascade and the fine tuning of setting parameters were found to be effective and economic separation process of the radioactive minerals from placer sands in Bangladesh. Probable radiological impacts and extraction potentiality of such radioactive materials are also discussed.

54 ENVIRONMENTAL SCIENCES↗

Laboratory-Based Micro-X-ray Computed Tomography of Energy Materials at Idaho National Laboratory

Abstract The Idaho National Laboratory (INL) has implemented laboratory-based micro-X-ray computed tomography in a laboratory equipped for the examination of highly radioactive samples. This capability provides nondestructive three-dimensional volumetric information on samples to inform subsequent traditional destructive examinations as well as real-world inputs for high-fidelity scientific modeling. Samples can be imaged with spatial resolutions ranging from several hundred nm/voxel up to ~ 100 µm/voxel. The best usable spatial resolution achieved to date is 384 nm/voxel with this instrument, while the highest radiological dose rate of a sample imaged is ~ 60 R/h β/γ on contact. Advanced data analysis, including custom tomographic reconstruction and segmentation methods, have also been developed to support this capability. In addition to traditional digital X-ray radiography and tomography, this instrument is also able to visualize in situ tensile and compression testing as well as perform diffraction contrast tomography. This work describes the X-ray computed tomography post-irradiation examination capabilities at INL, as well as detailing a variety of applications this instrument has examined.

36 MATERIALS SCIENCE↗