Search NASA⌕ Search

SEARCH · Search NASA

Results for “LAMP”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

LAMPS software

The dynamic prediction model along with its macro-processor capability and data flow system from the Drexel Limited-Area and Mesoscale Prediction System (LAMPS) were converted and recorded for the Perkin-Elmer 3220. The previous version of this model was written for Control Data Corporation 7600 and CRAY-1a computer environment which existed until recently at the National Center for Atmospheric Research. The purpose of this conversion was to prepare LAMPS for porting to computer environments other than that encountered at NCAR. The emphasis was shifted from programming tasks to model simulation and evaluation tests.

Perkey, D. J.↗

Orienting Arc Lamps for Longest Life

Temperature distribution strongly affects performance. Tests on floodlights for Space Shuttle payload bay show useful life of metal halide dc arc lamp prolonged by mounting "anode down" and wiring for maximum heat conduction away from electrodes. Anode-down configuration, anode and cathode temperatures stabilize at 333 degrees and 313 degrees C, respectively, after 1 hour of operation. Temperatures both below limit for quartz-to-metal seals, and lamps able to withstand a 2,000-hour life test with satisfactory light output at end.

Kiss, J.↗

Evaluation of miniature vacuum ultraviolet lamps for stability and operating characteristics, Lyman-Alpha task

Modifications required to change the near ultraviolet source in the Optical Contamination Monitor to a source with output at or near the Lyman-Alpha hydrogen line are discussed. The effort consisted of selecting, acquiring and testing candidate miniature ultraviolet lamps with significant output in or near 121.6 nm. The effort also included selection of a miniature dc high-voltage power supply capable of operating the lamp. The power supply was required to operate from available primary power supplied by the Optical Effect Module (DEM) and it should be flight qualified or have the ability to be qualified by the user.

Hurd, W. A.↗

Fundamental studies on a heat driven lamp

A detailed theoretical study of a heat-driven lamp has been performed. This lamp uses a plasma produced in a thermionic diode. The light is produced by the resonance transition of cesium. An important result of this study is that up to 30% of the input heat is predicted to be converted to light in this device. This is a major improvement over ordinary thermionic energy converters in which only approx. 1% is converted to resonance radiation. Efficiencies and optimum inter-electrode spacings have been found as a function of cathode temperature and the radiative escape factor. The theory developed explains the operating limits of the device.

Lawless, J. L.↗

Halogen lamp experiment, HALEX

The main purpose of the Halogen Lamp Experiment (HALEX) was to investigate the operation of a Halogen lamp during an extended period in a microgravity environment and to prove its behavior in space. Halex was funded by the European Space Agency under two separate contracts. The payload was designed and built by Kayser-Threde, who also coordinated the mission with NASA. The experiment was defined, built and maintained by Dornier System.

Gunter Schmitt↗

A spectral radiance comparison of a noise tube and a HgXe arc lamp between 60 GHz and 600 GHz

The relative spectral radiance of a noise tube, model TN-167, designed for the frequency range 90-140 GHz (3.3 mm to 2.1 mm) was compared to that from a 200-watt high pressure HgXe arc lamp over the wavelength region from 0.5 to about 5 mm. A Michelson Fourier transform spectrometer and a lamellar grating instrument were used in conjunction with liquid helium-cooled bolometers of NEP 10 to the -12th to 10 to the -14th watt/(Hz) exp 1/2 to measure relative spectral radiant power. With this instrumental arrangement, the noise tube exhibited a very sharp low frequency cutoff at about 2.2/cm. The HgXe arc lamp emitted more radiant power than the noise tube in the wavelength region below 3 mm (100 GHz) down to 0.5 mm. Above 3 mm, the noise tube had a stronger output. The noise tube spectral radiance shifted to lower frequencies when the input current was lowered from 125 mA to 50 mA.

Heaney, J. B.↗

Current Regulator For Sodium-Vapor Lamps

Regulating circuit maintains nearly-constant alternating current in sodium-vapor lamp. Regulator part of dc-to-ac inverter circuit used to supply power to street lamp from battery charged by solar-cell array.

Mclyman, W. T.↗

Monte Carlo simulation of the radiant field produced by a multiple-lamp quartz heating system

A method is developed for predicting the radiant heat flux distribution produced by a reflected bank of tungsten-filament tubular-quartz radiant heaters. The method is correlated with experimental results from two cases, one consisting of a single lamp and a flat reflector and the other consisting of a single lamp and a parabolic reflector. The simulation methodology, computer implementation, and experimental procedures are discussed. Analytical refinements necessary for comparison with experiment are discussed and applied to a multilamp, common reflector heating system.

Turner, Travis L.↗

Absolute Doppler shift calibration of laser induced fluorescence signals using optogalvanic measurements in a hollow cathode lamp

The paper investigates the use of optogalvanic (OG) measurements on the neutral 3P1 and 3P2 levels of argon in a hollow cathode lamp for the purpose of calibrating Doppler shifts of laser-induced fluorescence signals from an arcjet plume. It is shown that, even with non-Doppler-free OG detection, accuracy to better than 10 MHz is possible but that, depending on the experiment geometry, corrections of 10-35 MHz may be necessary to offset small axial drift velocities of neutral atoms in the hollow cathode lamp.

Ruyten, Wilhelmus M.↗

An analysis of the radiation field beneath a bank of tubular quartz lamps

Equations governing the incident heat flux distribution beneath a lamp-reflector system were developed. Analysis of a particular radiant heating facility showed good agreement between theory and experiment when a lamp power loss correction was used. In addition, the theory was employed to estimate thermal disruption in the radiation field caused by a protruding probe.

Ash, Robert L.↗

Spectral comparisons of sunlight and different lamps

The tables in this report were compiled to characterize the spectra of available lamp types and provide comparison to the spectra of sunlight. Table 1 reports the spectral distributions for various lamp sources and compares them to those measured for sunlight. Table 2 provides the amount of energy in Wm(exp -2) relative to the number of photons of PAR (photosynthetically active radiation) (400-700 nm) for each light source.

Deitzer, Gerald↗

Management of fluorescent lamps in controlled environment chambers

Management of fluorescent lights is recommended to (1) maintain uniformity of light intensity over time and (2) permit reproducibility of lighting conditions during experimental replications. At the McGill Phytotron, the lighting intensity can be controlled to desired level because any individual pair of the 40 lamps in each chamber can be set to be 'on' at any particular time. A lamp canopy service history is maintained for each experiment permitting accurate replication of lighting conditions for subsequent replicate trials.

Romer, Mark↗

Metal halide arc discharge lamp having short arc length

A metal halide arc discharge lamp includes a sealed light-transmissive outer jacket, a light-transmissive shroud located within the outer jacket and an arc tube assembly located within the shroud. The arc tube assembly includes an arc tube, electrodes mounted within the arc tube and a fill material for supporting an arc discharge. The electrodes have a spacing such that an electric field in a range of about 60 to 95 volts per centimeter is established between the electrodes. The diameter of the arc tube and the spacing of the electrodes are selected to provide an arc having an arc diameter to arc length ratio in a range of about 1.6 to 1.8. The fill material includes mercury, sodium iodide, scandium tri-iodide and a rare gas, and may include lithium iodide. The lamp exhibits a high color rendering index, high lumen output and high color temperature.

Muzeroll, Martin E.↗

Absence of a Detectable Lunar Nanodust Exosphere During a Search with LRO's LAMP UV Imaging Spectrograph

The Lyman-Alpha Mapping Project (LAMP) UV spectrograph on board the Lunar Reconnaissance Orbiter (LRO) performed a campaign to observe the Moon's nanodust exosphere, evidence for which was provided by the Lunar Atmosphere and Dust Environment Explorer (LADEE) Ultraviolet and Visible Spectrometer (UVS) during the 2014 Quadrantid meteoroid stream. These LADEE/UVS observations were consistent with a nanodust exosphere modulated by meteoroid impacts. LRO performed off-nadir maneuvers around the peak of the 2016 Quadrantids, in order to reproduce, as closely as possible, the active meteoroid environment and observing geometry of LADEE/UVS. We analyzed LAMP spectra to search for sunlight backscattering from nanodust. No brightness enhancement attributable to dust, of any size, was observed. We determine an upper limit for dust column concentration of ~10(^ 5) sq. cm for grains of radius ~25 nm, and an upper limit for dust column mass of ~10 11 g sq. cm, nearly independent of grain size for radii <100 nm.

Spectrograph↗

The Young Age of the LAMP-Observed Frost in Lunar Polar Cold Traps

The Lunar Reconnaissance Orbiter/Lyman Alpha Mapping Project (LAMP) ultraviolet instrument detected a 0.5–2% icy regolith mix on the floor of some of the southern pole permanently shadowed craters of the Moon. We present calculations indicating that most or all of this icy regolith detected by LAMP (sensed to a depth of <1 μm) has to be relatively young—less than 2,000 years old—due to the surface erosional loss by plasma sputtering (external ionized gas‐surface interactions), meteoric impact vaporization, and meteoric impact ejection. These processes, especially meteoric impact ejection, will disperse water along the crater floor, even onto warm regions where it will then undergo desorption. We have determined that there should be a water exosphere over polar craters (e.g., like Haworth crater) and calculated that a model 40‐km‐diameter crater should emit ~10(exp 19) H2O per second into the exosphere in the form of free molecules and ice‐embedded particulates.

Farrell, W. M.↗

High-Temperature Mechanical Tensile Testing of Unidirectional Sic/Sic Composites Using A Versatile Lamp Furnace

Silicon carbide (SiC) based ceramic matrix composites (CMCs) are of interest for high-temperature structural applications, including use in turbine engine components. To understand damage mechanisms and predict durability of these systems, in-depth knowledge of their behavior at ambient and high temperatures is necessary. A method for high temperature testing of SiC/SiC minicomposite specimens up to 1500oC in both tensile fast fracture and creep conditions to investigate their thermomechanical behavior will be presented. This method utilizes a novel radiation heat furnace, equipped with infrared lamps with ellipsoidal reflectors, to heat the specimen at the furnace center in user-defined atmospheres. The housing structure of the lamps allows for observation of the specimen during testing using optical methods and for conducting other experimental studies. The goal is to employ nondestructive health monitoring techniques in-situ, including acoustic emission (AE), electrical resistance (ER), and digital image correlation (DIC) to evaluate damage initiation and evolution in the minicomposite specimens during tensile testing. Results from mechanical testing and nondestructive techniques will be presented. Electron microscopy and X-ray micro-computed tomography were used to further characterize specimen damage after testing.

Aeronautics↗