At least 73 records · Page 4

Architecting Space Exploration Campaigns: A Decision-Analytic Approach

This paper shows the benefits of Decision Analysis techniques for campaign design and evaluation. Important concepts of decision analysis are reviewed through the lens of designing a campaign to find exploitable equatorial water on Mars. The method developed herein is general to any search campaign. The paper concludes with a discussion of the challenges and opportunities in applying similar techniques to other types of campaigns.

campaigns↗

Polarization aberrations in the solar activity measurements experiments (SAMEX) solar vector magnetograph

An optical design and polarization analysis of the Air Force/NASA Solar Activity Measurements Experiments solar vector magnetograph optical system is performed. Polarization aberration theory demonstrates that conventional telescope coating designs introduce unacceptably high levels of polarization aberrations into the optical system. Several ultralow polarization mirror and lens coatings designs for this instrument are discussed. Balancing of polarization aberrations at different surfaces is demonstrated.

Mcguire, James P., Jr.↗

Spaceborne multifunction imaging radar antenna development

Past and present studies of Multifunction Synthetic Aperture Radar Technology at NASA's Johnson Space Center have given attention to the design of lens antennas, planar arrays, and continuous apertures, such as reflectors. Current emphasis is on an interleaved, open ended waveguide array and microstrip antenna, with design work proceeding for multifrequency operation L, C, and X-band antennas, all of which possess multipolarization. In order to meet ground swath and azimuth resolution requirements, the antennas are designed to provide a beamwidth of 6.2 deg in elevation and 1 deg in azimuth.

Schaeper, H. R. A.↗

Neurophysiology

Studies in neural network stability and transition matrixes, impalement techniques for myoelectric fiber studies in cats, and method for lens fabrication by square plate deformation

MYOELECTRIC POTENTIAL↗

An upward looking airborne millimeter wave radiometer for atmospheric water vapor sounding and rain detection

A 90/180 GHz multichannel radiometer is currently under development for NASA's 1985 Hurricane Mission onboard the Convair 990 research aircraft. The radiometer will be a fixed beam instrument with dual corrugated horns and a common lens antenna designed to operate simultaneously at 90 and 180 GHz. The all solid state front-end will contain three double side band data channels at 90 + or - 3 GHz, 180 + or - 3 GHz, and 180 + or - 7 GHz. The airborne radiometer will mount in a window port on the CV-990 and will maintain a fixed beam view approximately 14 degrees off zenith. The radiometer design is a Dicke chopper arrangement selected to achieve maximum absolute temperature accuracy and minimum brightness temperature sensitivity. Analog outputs of the three data channels will be calibrated dc voltages representing the observed radiometric brightness temperatures over the selected integration time.

Gagliano, J. A.↗

Two component laser velocimeter measurements of turbulence parameters downstream of an axisymmetric sudden expansion

Simultaneous two-component laser velocimeter measurements were made in an axisymmetric sudden expansion flowfield. A specially designed correction lens was employed to correct optical aberrations introduced by the circular tube. This lens system allowed the accurate simultaneous measurement of axial and radial velocities in the test section. The experimental measurements were compared to predictions generated by a code which employed the k-epsilon turbulence model. Possible sources of differences observed between model predictions and the measurements are discussed.

Gould, Richard D.↗

Investigation of turbulent transport in an axisymmetric sudden expansion

Simultaneous two-component laser velocimeter measurements were made in the incompressible turbulent flowfield following an axisymmetric sudden expansion. Mean velocities, Reynolds stresses, and triple products were measured and are presented at axial positions ranging from x/H = 0.2-14. A balance of the turbulent kinetic energy in the flow was performed. The production, convection, and diffusion of turbulent kinetic energy were computed directly from the experimental data using central differencing. A specially designed correction lens was employed to correct for optical aberrations introduced by the circular tube. This lens system allowed the accurate simultaneous measurement of axial and radial velocities in the test section. The experimental measurements were compared to predictions generated by a code that employed the k-epsilon turbulence model. Agreement was good for mean axial velocities, turbulent kinetic energy, and turbulent shear stresses. However, the modeled turbulent normal stresses where in poor agreement with the measured values. The modeled diffusion of turbulent kinetic energy was underpredicted in the region between the shear layer and the centerline of the flow giving lower values of turbulent kinetic energy downstream of the potential core than measured.

Gould, Richard D.↗

An electronic pan/tilt/zoom camera system

A small camera system is described for remote viewing applications that employs fisheye optics and electronics processing for providing pan, tilt, zoom, and rotational movements. The fisheye lens is designed to give a complete hemispherical FOV with significant peripheral distortion that is corrected with high-speed electronic circuitry. Flexible control of the viewing requirements is provided by a programmable transformation processor so that pan/tilt/rotation/zoom functions can be accomplished without mechanical movements. Images are presented that were taken with a prototype system using a CCD camera, and 5 frames/sec can be acquired from a 180-deg FOV. The image-tranformation device can provide multiple images with different magnifications and pan/tilt/rotation sequences at frame rates compatible with conventional video devices. The system is of interest to the object tracking, surveillance, and viewing in constrained environments that would require the use of several cameras.

Zimmermann, Steve↗

The DS1 Mission and the Validation of the SCARLET Advanced Array

On October 24, 1998, the first of the NASA New Millenium Spacecraft, DS1, was successfully launched into Space. The objectives for this spacecraft are to test advanced technologies that can reduce the cost or risk of future missions. One of these technologies is the SCARLET concentrating solar array. Although part of the advanced technology validation study, the array is also the spacecraft's power source. Funded by BMDO, the SCARLET concentrator solar array is the first application of a refractive lens concentrator designed for space applications. As part of the DS1 validation process, the amount of diagnostics data that will be acquired is more extensive than would be the norm for a more conventional solar array. These data include temperature measurements at numerous locations on the 2-wing, 4-panel per wing, solar array. For each panel, one 5-cell module in one of the circuit strings is wired so that a complete I-V curve can be obtained. This data is used to verify sun pointing accuracy and array output performance. In addition, the spacecraft power load can be varied in a number of discrete steps from a small fraction of the array total power capability, up to maximum power. For each of the power loads, array operating voltage can be measured along with the current output from each wing. Preliminary in-space measurements suggest SCARLET performance is within one (1) percent of predictions made from ground data. This paper will briefly discuss the SCARLET configuration and critical features. Emphasis will be given to the results of the in-space validation, including array performance as a function of changing solar distance and array performance compared to pre-launch predictions.

Stella, Paul M.↗

Cryogenic Refractive Indices of S-LAH55, S-LAH55V, S-LAH59, S-LAM3, S-NBM51, S-NPH2, S-PHM52, and S-TIH14 Glasses

The Transiting Exoplanet Survey Satellite (TESS) is an explorer-class planet finder, whose principal goal is to detect small planets with bright host starts in the solar neighborhood. The TESS payload consists of four identical cameras and a Data Handling Unit (DHU) fitted with CCD detectors and associated electronics. Each camera consist of a lens assembly with seven optical elements that include various types of Ohara glass substrates. The successful implementation of a panchromatic and a thermal lens assembly design for these cameras requires a fairly accurate (up to 0.000001 (1e-6)) knowledge of the temperature- and wavelength-dependent of the refractive index in the wavelength and temperature range of operation. Hence, this paper is devoted to report on measurements of the refractive index over the wavelength range of 0.42-1.15 micrometers and temperature range of 110-300 K for the following Ohara glasses: S-LAH55, S-LAH55V, S-LAH59, S-LAM3, S-NBM51, S-NPH2, S-PHM52, and S-TIH14. The measurements were performed utilizing the Cryogenic High Accuracy Refraction Measuring System (CHARMS) facility at NASA's Goddard Space Flight Center. A dense coverage of the absolute refractive index for all these substrates in the aforementioned wavelength and temperature ranges was used to determine the thermo-optic coefficient (dndT) and dispersion relation (dnd) as a function of wavelength and temperature. A comparison of the measured indices with literature values, specifically the temperature-dependent refractive indices of S-PHM52 and S-TIH14 reported by Yamamuro et al. [Yamamuro et al., Opt. Eng. 45(8), 083401 (2006)], will be presented.

cryogenic temperatures↗