Modeling activities on the negative-ion-based Neutral Beam Injectors of the Large Helical Device

At the National Institute for Fusion Science (NIFS) large-scaled negative ion sources have been widely used for the Neutral Beam Injectors (NBIs) mounted on the Large Helical Device (LHD), which is the world-largest superconducting helical system. These injectors have achieved outstanding performances in terms of beam energy, negative-ion current and optics, and represent a reference for the development of heating and current drive NBIs for ITER.In the framework of the support activities for the ITER NBIs, the PRIMA test facility, which includes a RF-drive ion source with 100 keV accelerator (SPIDER) and a complete 1 MeV Neutral Beam system (MITICA) is under construction at Consorzio RFX in Padova.An experimental validation of the codes has been undertaken in order to prove the accuracy of the simulations and the soundness of the SPIDER and MITICA design. To this purpose, the whole set of codes have been applied to the LHD NBIs in a joint activity between Consorzio RFX and NIFS, with the goal of comparing and benchmarking the codes with the experimental data. A description of these modeling activities and a discussion of the main results obtained are reported in this paper.

43 PARTICLE ACCELERATORS↗

Stability of High Power Beam Injection in Negative-Ion-Based LHD-NBI

We describe the characteristic of stable beam injection in a neutral beam injector (NBI) for Large Helical Device (LHD) in high injection power of more than 6 MW. In the NBI, it takes a week after starting Cs seeding to finish the pre-injection conditioning. The injection starts with the beam power {approx}6.2 MW, and the maximum power reaches {approx}7 MW. The Cs-seeding rate affects the beam stability in such high power injections. By optimizing the rate to 0.65 mg/shot, the success ratio, which is defined as a ratio of actual pulse duration to setting one, increases to 85-90% in the power and energy range of more than 6.2 MW and 185 keV, respectively. The weights of Cs adsorbed on several surfaces in the ion sources of the NBI are measured by means of Inductively-Coupled Plasma Atomic Emission Spectroscopy (ICP-AES), and averaged surface densities are calculated by dividing with the several surface areas. The seeded Cs of 99.5% is condensed in the plasma generator, and very tiny amount of Cs reaches the surfaces of the accelerator grids. This very low amount of Cs on the grids is interpreted that most of the Cs atom evaporated from the inner walls is ionized during the arc discharges, and repelled to the source plasmas by the electrostatic field for H- extraction.

43 PARTICLE ACCELERATORS↗

Cavity Ring-Down System for Density Measurement of Negative Hydrogen Ion on Negative Ion Source

A Cavity Ring-Down (CRD) system was applied to measure the density of negative hydrogen ion (H{sup -}) in vicinity of extraction surface in the H{sup -} source for the development of neutral beam injector on Large Helical Device (LHD). The density measurement with sampling time of 50 ms was carried out. The measured density with the CRD system is relatively good agreement with the density evaluated from extracted beam-current with applying a similar relation of positive ion sources. In cesium seeded into ion-source plasma, the linearity between an arc power of the discharge and the measured density with the CRD system was observed. Additionally, the measured density was proportional to the extracted beam current. These characteristics indicate the CRD system worked well for H{sup -} density measurement in the region of H{sup -} and extraction.

43 PARTICLE ACCELERATORS↗

Z{sub eff} profile diagnostics using visible bremsstrahlung continuum for nonaxisymmetric plasmas with finite {beta} in large helical device

An astigmatism-corrected Czerny-Turner-type visible spectrometer coupled with a charge-coupled device has been installed in large helical device (LHD) to measure visible bremsstrahlung continuum. A full vertical profile has been observed from the elliptical plasmas at horizontally elongated plasma cross section through a 44 fiber parallel array with vertical observation length of {approx}1 m. Line emissions can be easily eliminated by use of the visible spectrometer instead of an interference filter. A nonmonotonic bremsstrahlung emission profile, which is originated in the thick ergodic layer surrounding the main plasma, has been observed for normal discharges in all the magnetic configurations of LHD. After analyzing the detailed structure, the lower half of the vertical bremsstrahlung emission profile is found to be free of the strong edge bremsstrahlung emission in inwardly shifted magnetic configurations (R{sub ax{<=}}3.60 m). The nonmonotonic bremsstrahlung emission disappeared in extremely high-density discharges (n{sub e{>=}}10{sup 14} cm{sup -3}) because of the reduction of the plasma outside boundary. When the local emissivity is calculated using Abel inversion, the solution is very sensitive to the distortion of the magnetic surface structure. The influence of the magnetic surface distortion based on the finite {beta} effect is examined as error estimation in addition to unclear edge plasma boundary due to the presence of the ergodic layer. The result indicates that the determination of the normalized minor radius for each observation chord gives a larger influence on the Abel inversion rather than the determination of the chord length. When the observed chord-integrated bremsstrahlung intensity profile is flat, the resultant uncertainty seen in the bremsstrahlung emissivity profile becomes large, in particular, at the plasma center. The Z{sub eff} profile calculated with consideration of density and temperature profiles is verified in neutral-beam-heated discharges with H{sub 2} and C pellet injections, where the Z{sub eff} values should be close to 1 and 6, respectively. Analysis on the flat and hollow electron density profiles results in a fairly flat Z{sub eff} profile.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Space-resolved extreme ultraviolet spectrometer for impurity emission profile measurement in Large Helical Device

A space-resolved extreme ultraviolet (EUV) spectrometer working in 60-400 A range has been developed to observe impurity emission profiles in core and edge plasmas of Large Helical Device (LHD). A flat focus is made for plane surface detector by using a varied line spacing holographic grating with an angle of incidence of 87 deg. An excellent spectral resolution of 0.22 A at 200 A is then obtained after careful adjustment of the optical components. In the profile measurement of the LHD plasmas, the toroidal resolution is important as well as the radial resolution because the magnetic surfaces of LHD quickly change when the observation chord is tilted at a slightly different toroidal location. Horizontal dispersion is therefore selected for the present spectrometer. As a result, the toroidal resolution of 75 mm is achieved at the plasma position. An enough radial resolution of 10 mm is also obtained at spatial-resolution slit width of 0.2 mm. In order to measure the full radial profile of LHD plasmas the spectrometer is placed at a distance of {approx}9200 mm away from the plasma center and a backilluminated charge-coupled device with a size of 6.6x26.6 mm{sup 2} is set vertical to the horizontal dispersion. Half of the LHD plasma, i.e., {approx}50 cm, can be measured along the vertical direction at horizontally elongated plasma cross section. A full vertical profile can be obtained by changing the vertical angle of the EUV spectrometer. As an example the full vertical profile of edge C IV (312.4 A) emission is presented. A wavelength interval of 35-65 A can be simultaneously observed, which varies according to the wavelength to be measured. A local emission profile of Fe XX (132.67 A) is also presented after Abel inversion as a typical example of the core EUV emission. Finally, the EUV spectrometer is absolutely calibrated using EUV bremsstrahlung continuum profile in comparison with absolute values of visible bremsstrahlung continuum profile because the bremsstrahlung continuum can be easily detected in high-density discharges of LHD.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

MHD MODES DESTABILIZED BY ENERGETIC IONS ON LHD

nergetic ion driven magnetohydrodynamic instabilities such as Alfven eigenmodes (AEs), energetic particle modes (EPMs), and their impacts on energetic ion confinement are being studied on the Large Helical Device (LHD). The magnetic configuration of this device is three dimensional and has negative magnetic shear over a whole radial region in the low-beta regime. Two types of toroidicity-induced Alfven eigenmodes (TAEs) are typically observed in LHD plasmas that are heated by tangential neutral beam injection: One is localized in the plasma core region near a central TAE gap and the other is a global TAE having a radially extended eigenfunction. Core-localized TAEs with even and odd radial mode parities are often observed. The global TAE is usually observed in medium- to high-beta plasmas where broad regions with low magnetic shear are present. Helicity-induced Alfven eigenmodes (HAEs), which exist in gaps unique to three-dimensional plasmas that have both toroidal and poloidal mode couplings, were detected for the first time. Recently, reversed magnetic shear Alfven eigenmodes (RSAEs) having characteristic frequency sweeping were discovered in reversed magnetic shear (RS) plasmas produced by intense counter-neutral beam current drive. In the RS plasma, the geodesic acoustic mode (GAM) excited by energetic ions, which is a global-type mode different from localized GAM excited by drift waves, was also detected for the first time in a helical plasma. Nonlinear couplings between RSAE and GAM modes and also between two TAEs were observed. Bursts of TAEs and EPMs often enhance radial transport and loss of energetic ions at low toroidal magnetic field (<0.75 T).

Toi, K.↗

Evaluation of Magnetic Diagnostics for MHD Equilibrium Reconstruction of LHD Discharges

Equilibrium reconstruction is the process of determining the set of parameters of an MHD equilibrium that minimize the difference between expected and experimentally observed signals. This is routinely performed in axisymmetric devices, such as tokamaks, and the reconstructed equilibrium solution is then the basis for analysis of stability and transport properties. The V3FIT code [1] has been developed to perform equilibrium reconstruction in cases where axisymmetry cannot be assumed, such as in stellarators. The present work is focused on using V3FIT to analyze plasmas in the Large Helical Device (LHD) [2], a superconducting, heliotron type device with over 25 MW of heating power that is capable of achieving both high-beta ({approx}5%) and high density (>1 x 10{sup 21}/m{sup 3}). This high performance as well as the ability to drive tens of kiloamperes of toroidal plasma current leads to deviations in the equilibrium state from the vacuum flux surfaces. This initial study examines the effectiveness of using magnetic diagnostics as the observed signals in reconstructing experimental plasma parameters for LHD discharges. V3FIT uses the VMEC [3] 3D equilibrium solver to calculate an initial equilibrium solution with closed, nested flux surfaces based on user specified plasma parameters. This equilibrium solution is then used to calculate the expected signals for specified diagnostics. The differences between these expected signal values and the observed values provides a starting {chi}{sup 2} value. V3FIT then varies all of the fit parameters independently, calculating a new equilibrium and corresponding {chi}{sup 2} for each variation. A quasi-Newton algorithm [1] is used to find the path in parameter space that leads to a minimum in {chi}{sup 2}. Effective diagnostic signals must vary in a predictable manner with the variations of the plasma parameters and this signal variation must be of sufficient amplitude to be resolved from the signal noise. Signal effectiveness can be defined for a specific signal and specific reconstruction parameter as the dimensionless fractional reduction in the posterior parameter variance with respect to the signal variance. Here, {sigma}{sub i}{sup sig} is the variance of the ith signal and {sigma}{sub j}{sup param} param is the posterior variance of the jth fit parameter. The sum of all signal effectiveness values for a given reconstruction parameter is normalized to one. This quantity will be used to determine signal effectiveness for various reconstruction cases. The next section will examine the variation of the expected signals with changes in plasma pressure and the following section will show results for reconstructing model plasmas using these signals.

30 DIRECT ENERGY CONVERSION↗

Effects of hydrogen isotope species on ITG microturbulence in LHD

Abstract The linear and nonlinear effects of hydrogen isotope species on ion temperature gradient (ITG) instability in the Large Helical Device (LHD) stellarator are studied using radially global gyrokinetic simulation. We found that the coupling range of linear toroidal harmonics depends on the ion mass of the hydrogen isotope. The growth rates of ITG mode are almost the same for H, D, and T plasmas, indicating a gyro-Bohm scaling of ion-mass dependence. The nonlinear electrostatic simulations show that the zonal flow breaks the radially elongated eigenmode structures and reduces the size of the turbulence eddies, which suppresses the turbulence and the ion heat transport in the LHD. The turbulence amplitude without the zonal flow is almost the same for H, D, and T plasmas, while it decreases with increasing ion mass of the hydrogen isotope when the zonal flow is present. The reduction of the turbulent transport with larger ion mass is mostly due to the enhancement of zonal flows by larger ion mass. The ion heat conductivity deviates from the gyro-Bohm scaling for both cases with and without the zonal flow.

Physics↗

Progress in Extending the High-Temperature Plasma Regime in the LHD

In this paper, we show the expansion of the high-temperature regime and related physical phenomena in the Large Helical Device (LHD). At the LHD, we have developed a high-temperature operational regime for both ion (T i ) and electron (T e ) temperatures through understanding the physical characteristics of high-temperature plasma, the enhancement of plasma heating, and the development of technical methods such as wall recycling control and impurity control. In particular, the formation of the ion internal transport barrier (i-ITB) and electron internal transport barrier (e-ITB) in the plasma core region is the key to improving plasma performance. In addition, the deuterium experiment that began in 2017 showed that, due to the isotope effect, the thermal transport of both ions and electrons is suppressed in deuterium plasma compared to light hydrogen plasma, and that a high central temperature can be achieved efficiently. Furthermore, the combination of neutral beam injection (NBI) and electron cyclotron heating (ECH) has extended the operating conditions that simultaneously maintain high T i and T e , and comprehensive research on plasma confinement characteristics with an eye to future fusion reactor conditions has progressed.

Large Helical Device↗

Establishment of a low recycling state with full density control by active pumping of the closed helical divertor at LHD

We report superior control of particle recycling and hence full governance of plasma density has been established in the Large Helical Device (LHD) using largely enhanced active pumping of the closed helical divertor (CHD). In-vessel cryo-sorption pumping systems inside the CHD in five out of ten inner toroidal divertor sections have been developed and installed step by step in the LHD. The total effective pumping speed obtained was 67 ± 5 m3 s -1 in hydrogen, which is approximately seven times larger than previously obtained. As a result, a low recycling state was observed with CHD pumping for the first time in LHD featuring excellent density control even under intense pellet fueling conditions. A global particle confinement time ($τ^*_p$) is used for comparison of operation with and without the CHD pumping. The $τ^*_p$ was evaluated from the density decay after the fueling of hydrogen pellet injection or gas puffing in NBI plasmas. A reliably low base density before the fueling and short $τ^*_p$ after the fueling were obtained during the CHD pumping, demonstrating for the first time full control of the particle balance with active pumping in the CHD.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

First impurity powder injection experiments in LHD

Injection of impurities in the form of sub-millimeter powder grains is performed for the first time in the Large Helical Device (LHD) plasma, employing the Impurity Powder Dropper (IPD) [A. Nagy et al., RSI 2018], developed and built by PPPL. Controlled amounts of boron (B) and boron nitride (BN) powder are injected into the helical plasma. Visible camera imaging, UV and charge exchange spectroscopy measurements show that the injected impurities effectively penetrate into the plasma in two different magnetic configurations.The prompt effects of the impurities on the plasma are characterized as the injection rate is scanned. The injected impurities provide a supplemental electron source, causing the plasma density to increase, together with the radiated power. Beneficial effects on the confined plasma temperature are observed at low plasma densities, due to an increased efficiency in NBI power absorption. For $n_{e,av}<10^{19}m^{-3}$ the powder grains penetrate deeper into the plasma, as they can be less effectively deflected by the plasma flow in the divertor leg, which they have to cross first as they are injected from the top of the machine.In this case, the created B ions are observed to move outwards from UV spectroscopy and charge exchange measurements, due to the outwards direction of the radial electric field. This makes low density plasmas a better candidate for powder boronization techniques.

Boron↗

High resolution measurements of core density collapse dynamics in LHD

The core density collapse (CDC) is an abrupt instability that degrades the performance of super dense core stellarator plasmas on the Large Helical Device (LHD). In LHD, CDCs have proved to be an operational limit in so-called outward-shifted configurations. New measurements with high time resolution Thomson scattering characterize dynamics of the instability in the core. The density profile is observed to collapse inwards, narrowing the density peak till the core itself collapses. A hot, radially localized feature is also observed in the electron temperature profile during the collapse and disappears within a few hundred microseconds of CDC onset.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Fast-ion confinement in LHD and W7-X (Final Technical Report)

This project was the PhD thesis project for Wataru Hayashi, who graduated in December 2025. In work performed prior to the award while Heidbrink was a Guest Professor at NIFS, we had established conditions for the study of fast-ion confinement in the Large Helical Device (LHD) with fast-ion D-alpha (FIDA) diagnostics. Subsequently, we proposed new sightlines that could augment the existing FIDA measurements with ones that were more sensitive to the highest energy ions. During the project period, the new sightlines were installed by the LHD team and showed the expected enhanced sensitivity to high-energy ions. Many LHD experiments were led by UCI scientists remotely during the pandemic and in-person afterward. One of these, which was led by one of Professor Zhihong Lin’s PhD students (Ethan Green) in collaboration with Hayashi and Heidbrink, resulted in a Nuclear Fusion article on the effect of radial electric fields on fast-ion confinement. The main output of the project, however, is two detailed experimental papers by Hayashi et al. The first of these is a study of neoclassical fast ion confinement in MHD-quiescent plasmas, a key issue in stellarator research. The second is an initial study of the effect of Alfven eigenmodes on fast-ion confinement. In addition to these studies, the project also helped partially support stellarator research with the GTC code by members of Prof. Lin’s group.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Global gyrokinetic particle simulations of microturbulence in W7-X and LHD stellarators

Global gyrokinetic particle simulations of electrostatic ion temperature gradient (ITG) instability show that the most unstable eigenmode is localized to some magnetic fieldlines or discrete locations on the poloidal plane in the Wendelstein 7-X (W7-X) stellarator due to its mirror-like magnetic fields, which vary strongly in the toroidal direction and induce coupling of more toroidal harmonics (n) to form the linear eigenmode than in the Large Helical Device (LHD) stellarator. Nonlinear electrostatic simulation results show that self-generated zonal flows are the dominant saturation mechanism for the ITG instabilities in both the LHD and W7-X. Additionally, radial widths of the fluctuation intensity in both the LHD and W7-X are significantly broadened from the linear phase to the nonlinear phase due to turbulence spreading. Finally, nonlinear spectra in the W7-X are dominated by low-n harmonics, which can be generated both by nonlinear toroidal coupling of high-n harmonics and by linear toroidal coupling with large amplitude zonal flows due to the 3D equilibrium magnetic fields.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Numerical Analyses of Energetic Particles in LHD

The confinement of energetic ions generated by neutral beam injection (NBI) and ion cyclotron resonance frequency heating is studied using GNET simulation code, in which the drift kinetic equation is solved in five-dimensional phase-space. The steady-state distributions of the energetic ions are obtained, and characteristics of the energetic-ion distribution depending on the plasma heating method are shown. The magnetic configuration effect on the energetic-ion confinement is also investigated, and it is found that the energetic-ion confinement is improved by a strong inward shift of the magnetic axis position in the major radius direction. The interaction between energetic particles and Alfven eigenmodes are investigated using the MEGA code and the AE3D code. A reduced version of the MEGA code has been developed to simulate the Alfven eigenmode (AE) evolution in the Large Helical Device (LHD) plasma with NBI and collisions taken into account. The spatial profile and frequency of the AE modes in the LHD plasma are analyzed with the AE3D code. The evolution of energetic particles and AE mode amplitude and phase are followed in a self-consistent way, while the AE spatial profiles are assumed to be constant. It is demonstrated that the AE bursts can be simulated with the new code.

74 ATOMIC AND MOLECULAR PHYSICS↗

Energetic-ion-driven global instabilities in stellarator/helical plasmas and comparison with tokamak plasmas

Comprehensive understanding of energetic-ion-driven global instabilities such as Alfven eigenmodes (AEs) and their impact on energetic ions and bulk plasma is crucially important for tokamak and stellarator/helical plasmas and in the future for deuterium-tritium (DT) burning plasma experiments. Various types of global modes and their associated enhanced energetic ion transport are commonly observed in toroidal plasmas. Toroidicity-induced AEs and ellipticity-induced AEs, whose gaps are generated through poloidal mode coupling, are observed in both tokamak and stellarator/helical plasmas. Global AEs and reversed shear AEs, where toroidal couplings are not as dominant were also observed in those plasmas. Helicity induced AEs that exist only in 3D plasmas are observed in the large helical device (LHD) and Wendelstein 7 Advanced Stellarator plasmas. In addition, the geodesic acoustic mode that comes from plasma compressibility is destabilized by energetic ions in both tokamak and LHD plasmas. Nonlinear interaction of these modes and their influence on the confinement of the bulk plasma as well as energetic ions are observed in both plasmas. In this paper, the similarities and differences in these instabilities and their consequences for tokamak and stellarator/helical plasmas are summarized through comparison with the data sets obtained in LHD. In particular, this paper focuses on the differences caused by the rotational transform profile and the 2D or 3D geometrical structure of the plasma equilibrium. Important issues left for future study are listed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Mode Purity of Electron Cyclotron Waves after Their Passage through the Peripheral Plasma in the Large Helical Device

Plasma heating and current drive with Electron Cyclotron Waves (ECWs) require precise control over the polarization state of ECWs to ensure that the entire input power is deposited where intended. However, due to the magnetic shear in the peripheral plasma, the polarization state can change. This effect is particularly pronounced in the Large Helical Device (LHD), where the magnetic field is sheared strongly. Here, we present a new code PARADE (PAraxial RAy DEscription) that can simulate the evolution of the polarization state along the beam propagation without resorting to full-wave modeling. We apply PARADE to the LHD plasma and simulate the evolution of the beam transverse structure, including the local amplitudes of the two electromagnetic eigenmodes. Here, the results surpass those yielded by the code LHDGauss used in the past. Based on these new results, we discuss how to improve the mode purity of ECWs by controlling the initial polarization state. A remarkable improvement is predicted numerically.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Layout and results from the initial operation of the high-resolution x-ray imaging crystal spectrometer on the Large Helical Device

First results of ion and electron temperature profile measurements from the x-ray imaging crystal spectrometer (XICS) diagnostic on the Large Helical Device (LHD) are presented. This diagnostic system has been operational since the beginning of the 2011 LHD experimental campaign and is the first application of the XICS diagnostic technique to helical plasma geometry. The XICS diagnostic provides measurements of ion and electron temperature profiles in LHD with a spatial resolution of 2cm and a time resolution of ≥ 10ms. Ion temperature profiles from the XICS diagnostic are possible under conditions where charge exchange recombination spectroscopy (CXRS) is not possible (high density) or is perturbative to the plasma (low density or radio frequency heated plasmas). Measurements are made by using a spherically bent crystal to provide a spectrally resolved 1D image of the plasma from line integrated emission of helium-like Ar 16+ . The final hardware design and configuration are detailed along with the calibration procedures. Line-integrated ion and electron temperature measurements are presented, and the measurement accuracy is discussed. Finally central temperature measurements from the XICS system are compared to measurements from the Thomson scattering and CXRS systems, showing excellent agreement.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗