Search NASA⌕ Search

SEARCH · Search NASA

Results for “LID”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

From PAH to fullerenes: Closing a nano bowl with a nano lid

Quantum chemical DLPNO-CCSD(T)/cc-pVDZ//B3LYP/6–31G(d) calculations have been performed to unravel the formation mechanism of buckminsterfullerene (C 60 ) via the reaction of the C 40 nano bowl (C 40 H 10 ) and corannulene (C 20 H 10 ). The generated potential energy surfaces and molecular properties were further utilized to evaluate equilibrium constants and rate constants of elementary chemical reactions involved in the C 60 synthesis. The overall C 40 H 10 + C 20 H 10 → C 60 + 10H 2 reaction is shown to be highly exoergic and hence thermodynamically favorable at temperatures above 700 K and a kinetically feasible pathway under high-temperature conditions was revealed. This route involves hydrogen atom abstraction steps to activate closed-shell reactants/intermediates alternating with cyclodehydrogenation reactions eventually zipping the edges between the reacting C 40 and C 20 units by consecutive closures of six- and five-membered rings between them. The reaction is driven/catalyzed by hydrogen atoms which carry out the hydrogen abstractions from C 60 H x and are later recovered on the cyclodehydrogenation stages. The initial association reaction, C 40 H 9 + C 20 H 10 → C 60 H 18 + H, linking the two units by a covalent C-C bond appears to represent the kinetic bottleneck of the whole multistep process. This reaction is fast at low temperatures but slows down and has its equilibrium shifted toward the reactants at high temperatures. Here, the feasibility of the proposed mechanism corroborates the hypothesis that C 60 can be produced through a series of elementary reactions typical for the PAH growth.

Equilibrium constant↗

Closing the lid on DNA end-to-end stacking interactions

Recent experiments suggest that short DNA strands associate by end-to-end stacking. Here, we report interactions between DNAs with modified ends. DNA duplexes, 20 bp long, were capped with short T{sub 4} loops at 2, 1 or 0 ends, and were placed in solutions containing 20 mM Mg{sup 2+}. Association was observed only in constructs with one or more uncapped ends. DNA-DNA interactions were characterized by measuring variations in small angle x-ray scattering (SAXS) curves at the lowest scattering angles. Second virial coefficients were computed from the SAXS data. Our results confirm that end-to-end stacking plays an important role in short strand DNA-DNA interactions.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Shock compression experiments on Lithium Deuteride (LiD) single crystals

Shock compression experiments in the few hundred GPa (multi-Mbar) regime were performed on Lithium Deuteride single crystals. This study utilized the high velocity flyer plate capability of the Sandia Z Machine to perform impact experiments at flyer plate velocities in the range of 17–32 km/s. Measurements included pressure, density, and temperature between ~190 and 570 GPa along the Principal Hugoniot—the locus of end states achievable through compression by large amplitude shock waves—as well as pressure and density of reshock states up to ~920 GPa. As a result, the experimental measurements are compared with density functional theory calculations, tabular equation of state models, and legacy nuclear driven results that have been reanalyzed using modern equations of state for the shock wave standards used in the experiments.

36 MATERIALS SCIENCE↗

Time-resolved laser-induced desorption spectroscopy (LIDS) for quantified in-situ hydrogen isotope retention measurement and removal from plasma facing materials

A laboratory scale laser induced thermal desorption spectroscopy system is developed and tested on tungsten-deuterium and titanium-deuterium codeposits, and its feasibility as a hydrogenic inventory measurement diagnostic is demonstrated over a range of retention values from 5 × 10 19 m -2 to 7 × 10 23 m -2 for absorbed laser power densities as low as 8 MW m -2 . Codeposit layer samples are grown by magnetron sputtering and immersed in a weak argon rf plasma. A 1 kW fiber laser (λ = 1100 nm) heats the samples up to a peak surface temperature ranging from 900 to 1500 K using pulse widths of 0.5 and 1 s. Spectral line emission from Balmer series Dα and Hα from thermally desorbed deuterium and hydrogen, as well as line emission from argon, are monitored as a function of time using an optical spectrometer with maximum temporal resolution of 1 ms. To correct for wall recycling and pumping speed, and to accurately measure the time evolution of the laser-induced thermal desorption, the raw Dα signal is deconvolved with the system response function, which is obtained by injecting a short burst of D 2 to approximate an impulse. Calibration is done with a standard D 2 leak, and laser induced desorption spectroscopy deuterium retention values are found to be in good agreement with companion measurements made using conventional temperature programmed desorption on samples from the same codeposit batch.

36 MATERIALS SCIENCE↗

Enzymes with lid-gated active sites must operate by an induced fit mechanism instead of conformational selection

The induced fit and conformational selection/population shift models are two extreme cases of a continuum aimed at understanding the mechanism by which the final key-lock or active enzyme conformation is achieved upon formation of the correctly ligated enzyme. Structures of complexes representing the Michaelis and enolate intermediate complexes of the reaction catalyzed by phosphoenolpyruvate carboxykinase provide direct structural evidence for the encounter complex that is intrinsic to the induced fit model and not required by the conformational selection model. In addition, the structural data demonstrate that the conformational selection model is not sufficient to explain the correlation between dynamics and catalysis in phosphoenolpyruvate carboxykinase and other enzymes in which the transition between the uninduced and the induced conformations occludes the active site from the solvent. The structural data are consistent with a model in that the energy input from substrate association results in changes in the free energy landscape for the protein, allowing for structural transitions along an induced fit pathway.

59 BASIC BIOLOGICAL SCIENCES↗

Instrumented Lid - System Final Design

Work is ongoing to create an instrumented and sampling system for monitoring aluminum clad spent nuclear fuel (ASNF) in dry storage. The anticipated system will be composed of a custom canister assembly and a modular instrument manifold. The conceptual design was first laid out in the Task Technical and Quality Assurance Plan (SRNL-RP-2019-00225). In this document, we outline the project progress to date, and describe the final system design.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

He Leak Testing of 3013 Inner Container Lids

The 3013-container package is used for the long-term storage of plutonium bearing materials at Department of Energy (DOE) sites. The package consists of three nested stainless-steel containers: outer, inner and convenience, which are made of stainless steel. The requirements of the DOE 3013 Standarda, also entail the development of a surveillance program, tasked to ensure structural integrity of the outer container for at least 50 years. The Materials Identification and Surveillance Working Group (MIS-WG) is specified to be responsible for selecting the containers for the surveillance as well as analyzing results. The MIS-WG determined that corrosion is a potential mechanism for container degradation with the most credible type of failure to be stress corrosion cracking (SCC) through wall breach of the inner container closure weld region (ICCWR). A breach of the inner container has the potential of allowing corrosive gases to be released into the safety class outer container.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Finite Element Analysis of Elastomeric Seals for LIDS

Objective: Create a means of evaluating seals w/o prototypes. Motivation: Cost Prototype 54" seal approx.$100k per seal pair FEA license + high end workstation approx. $30k per year. Development time: 6 months lead time for a new seal design Many designs per day (solution time <1 minute) Understanding: Difficult to experimentally measure strains, contact pressure profile, stresses, displacements

Oswald, Jay J.↗