Wind tunnel tests of a wing-installed model VTOL lift fan with coaxial drive turbine
Wing installed VTOL coaxial drive lift fan model in wind tunnel test, investigating performance in crosswind environment
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Wing installed VTOL coaxial drive lift fan model in wind tunnel test, investigating performance in crosswind environment
Conceptual designs of V/STOL lift-fan commercial short-haul transport aircraft for the 1980-85 time period were studied to determine their technical and economic feasibility. Engine concepts studied included both integral remote fans. The scope of the study included definition of the hover control concept for each propulsion system, aircraft design, aircraft mass properties, cruise performance noise, and ride qualities evaluation. Economic evaluation was also studied on a basis of direct operating cost and route structure.
The XV-5B lift-fan aircraft was used to explore the factors affecting handling qualities in the terminal area. A 10 deg ILS approach task was selected to explore these problems. Interception of the glide slope at 457.2 m, glide slope tracking, deceleration along the glide slope to a spot hover were considered. Variations in airplane deck angle, deceleration schedule, and powered-lift management were studied. The overall descent performance envelope was identified on the basis of fan stall, maximum comfortable descent rate, and controllability restrictions. The collective-lift stick provided precise glide slope tracking capability. The pilot preferred a deck-parallel attitude for which he used powered lift to control glide slope and pitch attitude to keep the angle of attack near zero. Workload was reduced when the deceleration schedule was delayed until the aircraft was well established on the glide slope, since thrust vector changes induced flight path disturbances.
Wind-tunnel tests on lifting-fan propulsion system for v/stol aircraft - fan-in-fuselage and fan-in-wing configurations are considered
Theoretical analysis of axisymmetric flow in VTOL lift fan inlets without crossflow
V/STOL aircraft rely on their propulsion systems to provide lift and attitude control moments during hover and low-speed flight. For lift-fan powered V/STOL aircraft, two unconventional propulsion system types have been proposed. The first type uses fans connected by hot gas ducting, and the second type uses fans connected by cross shafting. This paper presents results of an analytical study which identifies the basic steady-state and dynamic characteristics for each type of system. For the gas-coupled system, the control concepts analyzed were variable-area fan turbines and throttling valves in the ducting. For the shaft-coupled system, the control concepts analyzed were variable-pitch fans and variable fan inlet guide vanes. All of these concepts are shown to be capable of meeting V/STOL aircraft control moment and transient response requirements when appropriate propulsion controls are used. Each type of system has unique problem areas which require an integrated approach to aircraft/propulsion control design.
Hand calculation procedures for predicting aerodynamic noise from propellers, rotors, and lift fans
Wind tunnel tests of V/STOL transport model with six wing mounted lift fans
Flight characteristics of V/STOL transport model with four pod-mounted lift fans
Evaluation of air generator-remote lift fan propulsion system for VTOL transports
Wind tunnel investigation of V/STOL transport model with four pod-mounted lift fans
Test results of the LF336/E statorless lift fan with serrated and unserrated rotor leading edges are presented. Fan broadband noise reductions from 2 to 5 dB were achieved in the forward quadrant at frequencies from 100 to 2500 Hz. Broadband noise near and above the blade passing frequency was reduced only at angles of 80 to 100 degrees.
Theoretical analysis of aerodynamic interference induced by cruise and lift fans on transport type aircraft
Cross flow wind tunnel performance tests of 15 in. wing installed lift fan with coaxial drive turbine for VTOL transport aircraft
Aerodynamic characteristics of V/STOL transport model with tandem lift fans mounted at mid-semispan of wing
Free flight tests in hoovering and forward flight free flight tests in hovering and forward flight lift fans
Preliminary engine design studies have been made of two general types of low-pressure-ratio lift fan engines that are receiving increasing attention as a means to provide low-speed lift for large civilian VTOL transports. The two engine types are integral fans and remote powered fans. A portion of the results of these design studies is summarized, including the crucial engine requirements, and some of the characteristics of the emerging engine designs of each type.
Full admission baseline performance was obtained for a 0.4 linear scale of the LF460 lift fan turbine over a range of speeds and pressure ratios without leakage air. These cold-air tests covered a range of speeds from 40 to 140 percent of design equivalent speed and a range of scroll inlet to diffuser exit static pressure ratios from 2.0 to 4.2. Results are presented in terms of specific work, torque, mass flow, efficiency, and total pressure drop.