Topical Report – Findings on Subtask 2.7 – Wet ESP and Aerosol Testing at Coal Creek Station

Growing concerns over the impact of CO 2 emissions from combustion sources on global climate change have prompted numerous research and development projects aimed at developing cost-effective technologies for CO 2 capture. One family of technologies being demonstrated at pilot and full scale globally is postcombustion carbon capture (PCCC) systems that employ amine-based solvents. The captured CO 2 can be compressed and permanently stored underground or used for enhanced oil recovery. The proximity of North Dakota’s lignite-fired fleet of power plants to potential CO 2 storage options creates a unique atmosphere for PCCC within the state. However, the unique components present in lignite flue gas present a challenge for large-scale PCCC at North Dakota power plants by contributing to aerosol formation. Aerosols can negatively impact the long-term performance of amine-based solvents for CO 2 capture. Amine-based solvents are volatile, and flue gas particulate provides nucleation sites where amine vapors can condense as aerosols. Because aerosols cannot be easily captured at the column outlet using conventional technologies, the amine-laden aerosols escape the system and lead to accelerated solvent losses. Moreover, particulate components can chemically react with amines to form degradation products that can permanently deactivate the amine, cause fouling, and lead to hazardous emissions. Many of the elements that have been shown to catalyze solvent degradation are present in lignite coals and can exacerbate solvent replacement economics. Understanding this issue is critical to the implementation of solvent-based CO 2 capture systems as applied to lignite-fired generation systems. The Energy & Environmental Research Center (EERC) designed and carried out this project to fully characterize aerosol behavior with various control technologies installed to better optimize aerosol mitigation technology for CO 2 capture. To meet the goal of this project, the following objectives were identified: Determine the effectiveness of a wet electrostatic precipitator (WESP) on mitigating formation of problematic aerosols at Great River Energy’s Coal Creek Station, upstream of the PCCC system. Determine the effectiveness of the Mitsubishi Heavy Industries (MHI) proprietary amine emission reduction unit (AERU) as a postcapture solvent recovery system for reducing aerosol emissions and extending solvent life downstream of the PCCC system. Determine the impact of aerosols on the efficiency and degradation products of both commercial and advanced solvents within the PCCC system. Work was conducted at Coal Creek Station Unit 1 using a slipstream of flue gas from the outlet of the plant’s flue gas desulfurization (FGD) unit. Flue gas was routed through a pilot-scale FGD unit to remove SO 2 to very low levels (~1 ppm) and then through a direct contact cooler (DCC) to further cool the gas and to remove moisture. The gas exiting the DCC was then optionally routed through a WESP before passing to the CO 2 absorber columns. The MHI solvent was used to scrub CO 2 from the slipstream through a set of two absorber columns. The rich solvent was regenerated in a stripper column by heating to drive off captured CO 2 . Flue gas exiting the absorber column was routed to MHI’s proprietary AERU to recover entrained solvent. The system operated using a catch-and-release method where the CO 2 was separated to provide data on the process, but the captured CO 2 was released back into the host site stack. Particulate was measured, collected, and analyzed from multiple locations throughout the pilot-scale system. Unlike the performance observed in prior work, the inlet FGD and DCC did not remove significant particulate matter from the flue gas. This appears to be due to a difference in the nature of the particulate. The DCC seemed to increase particulate size and count, most likely owing to water condensing onto the surfaces of fly ash particles. When the WESP was operated, it achieved >95% particulate capture. Very little particulate matter or indications of solvent were detected at the AERU outlet. When operating with advanced KS 21 solvent, the particulate material at the AERU outlet was even further decreased. Solvent analysis showed that some species derived from flue gas and ash were slowly concentrating in the solvent over the duration of the test. The levels observed were reported to be within expected ranges and were not of concern to MHI. A high-level techno-economic assessment of installing CO 2 capture at Coal Creek Station suggested that, when using a standard monoethanolamine (MEA)-based solution with simple heat integration, the energy penalty to net generation would be 34%. The bulk of this was due to steam losses for regenerating solvent, followed by parasitic electrical demand for CO 2 compression and then by increased parasitic load for pushing flue gas through the absorber column. These demands could be decreased with a more advanced solvent that exhibits lower heat of regeneration and lower pressure drop than does a simple MEA solution. Further energy could be saved with more thorough heat integration to recover useful energy from the steam used for solvent regeneration. Installing a WESP was predicted to increase the cost of electricity by nearly $5/MWh. This would become cost-effective if solvent losses were roughly 10 times the baseline estimate when not using a WESP but could be returned to baseline by installing the WESP. Piping CO 2 for storage in more favorable geology could help with carbon capture and storage economics. Although storing off-site would necessitate construction of a CO 2 transport pipeline, the cost of this pipeline might be more than offset by reducing the number of wells required, the depths of the wells required, and the electrical demand for the CO 2 compressor. Additional factors that favor off-site storage costs include smaller expected CO 2 plume sizes, which translates to less monitoring and fewer landowner agreements. More detailed assessment of the specific geology in the region under and around Coal Creek Station would be needed to accurately assess the costs and benefits of different storage site options. This subtask was cofunded through the Energy & Environmental Research Center–U.S. Department of Energy Joint Program on Research and Development for Fossil Energy-Related Resources Cooperative Agreement No. DE-FE0024233. Nonfederal funding was provided by the North Dakota Industrial Commission.

Strege, Joshua↗

Reactivity of pulverized coals during combustion catalyzed by CeO{sub 2} and Fe{sub 2}O{sub 3}

Effects of CeO{sub 2} and Fe{sub 2}O{sub 3} on combustion reactivity of several fuels, including three ranks of coals, graphite and anthracite chars, were investigated using thermo-gravimetric analyzer. The results indicated that the combustion reactivity of all the samples except lignite was improved with CeO{sub 2} or Fe{sub 2}O{sub 3} addition. It was interesting to note that the ignition temperatures of anthracite were decreased by 50 C and 53 C, respectively, with CeO{sub 2} and Fe{sub 2}O{sub 3} addition and that its combustion rates were increased to 15.4%/min and 12.2%/min. Ignition temperatures of lignite with CeO{sub 2} and Fe{sub 2}O{sub 3} addition were 250 C and 226 C, and the combustion rates were 12.8% and 19.3%/min, respectively. When compared with those of lignite without catalysts, no obvious catalytic effects of the two catalysts on its combustion reactivity were revealed. The results from the combustion of the three rank pulverized coals catalyzed by CeO{sub 2} and Fe{sub 2}O{sub 3} indicated significant effects of the two catalysts on fixed carbon combustion. And it was found that the higher the fuel rank, the better the catalytic effect. The results of combustion from two kinds of anthracite chars showed obvious effects of anthracite pyrolysis catalyzed by CeO{sub 2} and Fe{sub 2}O{sub 3} on its combustion reactivity. (author)

01 COAL, LIGNITE, AND PEAT↗

Conversion Of Coal To Li-Ion Battery Grade (Potato) Graphite (Final Technical Report)

It was previously shown that biomass could be readily transformed to Li-ion battery grade graphite with performance that is equivalent to commercial graphite. This project extended that result to lignite coal, an abundant and inexpensive resource in the United States. It was found that lignite from North Dakota (ND), following charring and exposure to near-infrared light from a laser in the presence of an iron metal catalyst, graphitizes with high yield, crystallinity and purity. Furthermore, spheroidal (“potato”) shaped graphite agglomerates can be produced from ND lignite with performance that rivals that of commercial graphite. Finally, the process was found to be potentially economical, to that extent that it may be able to disrupt the current market, if the laboratory results obtained under this project can be successfully translated to industrial scale.

01 COAL, LIGNITE, AND PEAT↗

Roles of mineral matter in the early stages of coal combustion

In a recent study, we discovered that oxygen from the gas phase, organic portions of the coal, and minerals in the coal have profound influence on the formation and desorption of stable surface oxides in the early stages of coal combustion. In an attempt to isolate the effects of minerals, demineralized coals (DMC) are oxidized in O{sub 2} with a contact time less than 1 s, and the amount and strength of stable surface oxides are characterized by temperature-programmed desorption (TPD) up to 1650{sup o}C. Young chars derived from both demineralized lignite and bituminous coals show low and flat TPD profiles over a wide temperature range, signifying the minerals' catalytic activities in forming stable surface oxides for both coals. Indeed, the oxidation rates of chars from both bituminous coals and lignite, estimated based on the O{sub 2} concentrations entering and exiting the Al{sub 2}O{sub 3} reactor, were higher than their DMC counterparts. Moreover, graphite, containing no minerals and organically bound oxygen, has an even lower oxidation rate. Similar to those for the raw coals, the combined oxygen balance and elemental analysis of chars from DMC suggests that the oxygen in the organic portion of the lignite activates oxygen turnover and carbon oxidation during its combustion; neither chars from raw nor demineralized bituminous coals possess these properties. X-ray photoelectron spectroscopy (XPS) of raw and demineralized bituminous coals and their char show peaks at around 532.0 eV in the O(1s) difference spectrum, suggesting the possible existence of intercalated stable surface oxides. 35 refs., 7 figs., 4 tabs.

01 COAL, LIGNITE, AND PEAT↗

CO 2 utilization potential of a novel calcium ferrite based looping process fueled with coal: Experimental evaluation of various coal feedstocks and thermodynamic integrated process analysis

Here, conversion of CO 2 to CO was performed at 800-850C via reduction of calcium ferrite (CaFe 2 O 4 ) with coal followed by oxidation of reduced CaFe 2 O 4 with CO 2 to produce CO and partially oxidized Ca ferrite. The process was evaluated with several types of coals which included lignite, sub-bituminous, bituminous, anthracite and pet-coke. Reduction of CaFe 2 O 4 with sub-bituminous coal and lignite coal was more favorable than that with higher rank coals. Stable reactivity performance was demonstrated for 35-cycle test conducted with lignite coal/CaFe 2 O 4 at 800°C and with high conversion of CO 2 to CO. The rate of conversion of CO 2 to CO with reduced CaFe 2 O 4 was found to be 1st order with respect to CO 2 and had a low activation energy of 7.4 kJ/mol. Thermodynamic integrated process assessments suggest that two and three reactor process concepts can be realized and net CO 2 utilization achievable. The two reactor configuration shows the highest potential for CO 2 utilization while generating a value-added CO rich syngas stream.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Microbe-Encapsulated Silica Gel Biosorbents for Selective Extraction of Scandium from Coal Byproducts

Establishing an inexpensive and environmentally friendly scandium (Sc) supply is critical for the development of clean energy technologies. However, refining Sc from Sc-bearing sources using current technologies poses economic and environmental challenges due to its low concentration relative to base metals and chemically similar lanthanides. In this work, we developed a biosorption-based flow-through process for extraction of Sc from low-grade feedstocks. A novel biosorbent material was synthesized by encapsulating Arthrobacter nicotianae, a bacterium that selectively adsorbs Sc, within a porous silica matrix. Through the use of several complementary microscopy techniques, we demonstrated a highly porous biosorbent structure with a high cell-loading density and a homogenous cell distribution. Batch adsorption assays revealed selective Sc adsorption over lanthanides and common based metals, with the exception of Fe(III), as evidenced by separation factors greater than 50. The MESG particles were packed into fixed-bed columns to enable adsorption under flow-through conditions, which demonstrated effective Sc extraction at flow rates up to 0.08 cm/s and high stability for reuse; greater than 95% of the adsorption capacity was maintained after 10 consecutive adsorption/desorption cycles. When applied to a lignite coal leachate, whose Fe content was depleted through pH-mediated precipitation, the MESG particles yielded Sc breakthrough at 30 bed volumes, whereas all other metals broke through after only a few bed volumes. Following desorption, an eluate with a 124-fold increase in Sc purity was achieved relative to the lignite leachate with Sc constituting 96.4% of the total REEs. This study established a rapid, facile, and scalable cell immobilization approach that enables the use of microbial biomass for Sc recovery from low-grade sources.

Dong, Ziye↗

Evaluation of Thermal Evolution Profiles and Estimation of Kinetic Parameters for Pyrolysis of Coal/Corn Stover Blends Using Thermogravimetric Analysis

The thermal evolution profiles and kinetic parameters for the pyrolysis of two Montana coals (DECS-38 subbituminous coal and DECS-25 lignite coal), one biomass sample (corn stover), and their blends (10%, 20%, and 30% by weight of corn stover) have been investigated at a heating rate of 5°C/min in an inert nitrogen atmosphere, using thermogravimetric analysis. The thermal evolution profiles of subbituminous coal and lignite coal display only one major peak over a wide temperature distribution, ~152–814°C and ~175–818°C, respectively, whereas the thermal decomposition profile for corn stover falls in a much narrower band than that of the coals, ~226–608°C. The nonlinearity in the evolution of volatile matter with increasing percentage of corn stover in the blends verifies the possibility of synergistic behavior in the blends with subbituminous coal where deviations from the predicted yield ranging between 2% and 7% were observed whereas very little deviations (1%–3%) from predicted yield were observed in blends with lignite indicating no significant interactions with corn stover. In addition, a single first-order reaction model using the Coats-Redfern approximation was utilized to predict the kinetic parameters of the pyrolysis reaction. The kinetic analysis indicated that each thermal evolution profile may be represented as a single first-order reaction. Three temperature regimes were identified for each of the coals while corn stover and the blends were analyzed using two and four temperature regimes, respectively.

Bhagavatula, Abhijit↗

Advanced Fossil Energy Separations and Analysis Research – Thermal Desorption Using Spouted Beds

Mercury and other contaminants in emissions from coal-fired power plants are of interest due to the cost associated with capture and disposal of toxic mercury species. It had recently been postulated in the fossil energy community that spouted beds may be a viable coal pre-treatment technique for thermal desorption of mercury. Spouted beds have the potential to be a near-ideal solid-gas contactor for desorption of mercury species, especially with a few proposed design changes specific for this application. Introduction of draft tubes for spouted beds has addressed some issues with scale-up to better handle the throughput and particle size found in coal-fired power plants. In Phase I, Mainstream Engineering invented and developed a Venturi draft tube spouted bed (VDTSB) to enable process scale-up with fine coal particles and to improve heat and mass transfer. The VDTSB concept increases suction at the bottom of the bed to better entrain material (and reduce the propensity for bridging) at the bottom of the conical vessel. The main advantages of this patent-pending approach are the ability to accept a wide range of coal particle sizes, good heat/mass transfer, process scalability, and robustness. The desorber design was optimized through bed flow visualization experiments; these experiments demonstrated the increased throughput and ease of process scale-up. A high-temperature pilot-scale VDTSB desorber system was designed, fabricated, commissioned, and tested. The heat and mass transfer rates with the VDTSB were measured and compared to a baseline spouted bed with and without a conventional straight draft tube. Pilot-scale VDTSB system performance tests were completed with the Energy and Environmental Research Center (EERC) to measure the rate of mercury desorption over a range of pulverized coal particle sizes, bed temperatures, and reactor geometry. Based on performance results, an initial technoeconomic analysis (TEA) was completed to estimate the cost reduction for emissions treatment compared to current flue-gas mercury capture systems. The following was accomplished in Phase I: Developed scalable design correlations for high-throughput spouted bed systems; Determined cycle time distribution (CTD) and turnover time for straight and Venturi draft tube spouted beds, and showed the VDTSB had lower cycle time (faster turnover) than the straight draft tube (SDT); Reduced weighted-average turnover time by 14% to 43% with Venturi draft tube; narrowed the CTD by up to 75%; Measured heat and mass transfer within the pilot-scale VDTSB desorber and showed that the highest heat transfer rate was 2.98 kW/m 2 ·s with 400 µm particles at a 10 L/min motive gas flowrate; Measured mercury (Hg) desorption rate for lignite, bituminous, and subbituminous coal at 200 °C, 225 °C, 250 °C and 275 °C; Achieved 5.6×10 -10 kg/m 2 -h, 2.6×10 -10 kg/m 2 -h, and 6.5×10 -11 kg/m 2 -h Hg removal rates for lignite, bituminous, and sub-bituminous coals, respectively with no loss in volatile matter and an increase in heating value due to a reduction in moisture content; The unoptimized VDTSB pilot desorber decreased the total mercury concentration of lignite and bituminous coal tests by 61% (dry basis). The subbituminous Powder River Basin (PRB) coal showed a reduction of 18%; Based on our TEA of coal-fired power plants, implementing the VDTSB for coal pretreatment could reduce the mercury capture capital and operating expenses by 36% and 38%, respectively, which exceeded the target goal of 25% reduction; A patent application was prepared, and the results were presented at the 2017 AIChE Annual Meeting (Minneapolis, MN).

20 FOSSIL-FUELED POWER PLANTS↗

Less-costly activated carbon for sewage treatment

Lignite-aided sewage treatment is based on absorption of dissolved pollutants by activated carbon. Settling sludge is removed and dried into cakes that are pyrolyzed with lignites to yield activated carbon. Lignite is less expensive than activated carbon previously used to supplement pyrolysis yield.

Ingham, J. D.↗

System analysis of nuclear-assisted syngas production from coal - article no. 042901

A system analysis has been performed to assess the efficiency and carbon utilization of a nuclear-assisted coal gasification process. The nuclear reactor is a high-temperature helium-cooled reactor that is used primarily to provide power for hydrogen production via high-temperature electrolysis. The supplemental hydrogen is mixed with the outlet stream from an oxygen-blown coal gasifier to produce a hydrogen-rich gas mixture, allowing most of the carbon dioxide to be converted into carbon monoxide, with enough excess hydrogen to produce a syngas product stream with a hydrogen/carbon monoxide molar ratio of about 2:1. Oxygen for the gasifier is also provided by the high-temperature electrolysis process. The results of the analysis predict 90.5% carbon utilization with a syngas production efficiency (defined as the ratio of the heating value of the produced syngas to the sum of the heating value of the coal plus the high-temperature reactor heat input) of 64.4% at a gasifier temperature of 1866 K for the high-moisture-content lignite coal considered. Usage of lower moisture coals such as bituminous can yield carbon utilization approaching 100% and 70% syngas production efficiency.

01 COAL, LIGNITE, AND PEAT↗

Characterization of sorbent properties of soil organic matter and carbonaceous geosorbents using n-alkanes and cycloalkanes as molecular probes

Nonspecific interactions and modes (i.e., adsorption vs absorption) of sorption by noncondensed, amorphous organic phases (here termed organic matter; OM) in soils and by rigid, aromatic, and condensed phases (termed carbonaceous geosorbents; CGs) were investigated using n-alkanes and cycloalkanes as molecular probes. Sorption isotherms of and cyclooctane from water for seven CGs (charcoal, lignite coke, activated carbon, graphite, partially oxidized graphite, diesel soot, bituminous coal), four sorbents with a predominance of OM (lignite, peat, two sapric soils), and two soils containing OM and high amounts of CGs were measured in batch systems. The peat and the sapric soils showed extensively linear sorption, while the CGs exhibited highly nonlinear and strong (K{sub oc} values being up to 105 times those for the OM-rich materials at low concentrations) sorption for the alkanes studied, showing that enhanced sorption by CGs can occur to completely apolar sorbates that do not undergo any specific interaction. The n-octane-to-cyclooctane sorption coefficient ratios for adsorption to CGs were {ge}1, being distinctly different from those for absorption to the OM-rich materials. The measured sorption isotherms and the CG compositions in the soils determined by quantitative petrography analysis suggest, however, that CGs occurring in soils may be far less effective sorbents than the reference CGs used in the sorption experiments at least for nonspecifically interacting sorbates, probably because of competitive sorption and/or pore blocking by natural OM. The presented approaches and results offer a basis for interpreting sorption data for other organic compounds, as nonspecific interactions and sorption modes are relevant for any compound. 47 refs., 4 figs., 2 tabs.

01 COAL, LIGNITE, AND PEAT↗

Application of model-free methods for analysis of combustion kinetics of coals with different ranks

Model-free kinetic approaches were employed to investigate the combustion kinetics of coals with different ranks, namely, lignite, bituminous coal, and anthracite. The experimental data were provided under non-isothermal conditions at different heating rates in the range of 2-25C min{sup -1}. The activation energy values were estimated by two model-free methods, that is, Ozawa-Flynn-Wall and Kissinger-Akahira-Sunose methods. Slightly higher activation energy values were obtained by Ozawa-Flynn-Wall method at a wide range of conversion extent. Variation of activation energy was found to be comparably more significant for lower rank lignite (between 44.82 and 287.56 kJ mol{sup -1}) while less significant for higher rank bituminous coal (between 101.97 and 155.64 kJ mol{sup -1}) and anthracite (between 106.04 and 160.31 kJ mol{sup -1}).

01 COAL, LIGNITE, AND PEAT↗

Turkey's energy demand and supply

The aim of the present article is to investigate Turkey's energy demand and the contribution of domestic energy sources to energy consumption. Turkey, the 17th largest economy in the world, is an emerging country with a buoyant economy challenged by a growing demand for energy. Turkey's energy consumption has grown and will continue to grow along with its economy. Turkey's energy consumption is high, but its domestic primary energy sources are oil and natural gas reserves and their production is low. Total primary energy production met about 27% of the total primary energy demand in 2005. Oil has the biggest share in total primary energy consumption. Lignite has the biggest share in Turkey's primary energy production at 45%. Domestic production should be to be nearly doubled by 2010, mainly in coal (lignite), which, at present, accounts for almost half of the total energy production. The hydropower should also increase two-fold over the same period.

01 COAL, LIGNITE, AND PEAT↗

The role of natural purified humic acids in modifying mercury accessibility in water and soil

We investigated the influence of different humic acids (HAs, extracted from lignite, compost, and forest soil) on mercury mobility and availability both in a model solution and in soil samples from a mercury-polluted region. The technique of diffusive gradients in thin-films (DGT), which is capable of measuring: (i) free metal in solution: (ii) dissociated metal complexes previously mobilized by HA; (iii) mobilized metal-HA complexes that liberate metals by dissociation or by exchange reaction between the metal-HA complexes and the chelating groups on the resin-gel, was used in solutions and soils. The DGT measurements in solution, together with ultrafiltration, allowed estimation of the lability of Hg-HA complexes. Ultrafiltration results were also compared with predictions made by the windermere humic-aqueous model (WHAM). According to both these different approaches, Hg{sup 2+} resulted nearly 100% complexed by HAs, whereas results from ultrafiltration showed that 32 to 72% of the CH{sub 4}Hg{sup +} was bound to the HAs, with higher values for compost and lower values for forest and Aldrich HA. The DGT-measured mercury in soils was below 0.20 {mu}g L{sup -1}, irrespective of the extent of the contamination. Addition of HA increased the concentration of DGT-measured mercury in soil solution up to 100-fold in the contaminated soil and up to 30-fold in the control soil. The level of the increase also depended on the HA. The smallest increase (about 10 times) was found for lignite HA in both control and contaminated soils. The addition of forest HA gave the largest increases in DGT-measured mercury, in particular for the contaminated soil. Overall, the results demonstrated that DGT can be used for estimating the lability of mercury complexes in solution and for verifying enhanced mercury mobility when HA is added to contaminated soils.

01 COAL, LIGNITE, AND PEAT↗

Investigation of Rare Earth Element Extraction from North Dakota Coal-Related Feedstocks (Phase 2 Final Technical Report)

There were four major goals of this project: i) identify promising lignite or lignite-related feedstocks with total rare earth element content above 300 parts per million (ppm), ii) evaluate at the lab and bench-scale the extractability of the REE from the material, iii) determine the processing required to generate REE concentrates in excess of 2 wt%, iv) evaluate the economic feasibility of the process and develop a pathway for commercialization. In the Phase 1 study, work was primarily focused upon resource evaluation and labscale extractability of the REE, with a preliminary techno-economic assessment (TEA) conducted, whereas in the Phase 2 work, the extraction process was conducted at the bench scale, a method for cost-effective generation of higher purity mixed REE concentrates (up to 65%) was developed, and a refined TEA on the bench-scale data for a 1,000 kg coal processing test was conducted.

01 COAL, LIGNITE, AND PEAT↗

Rare Earth Extraction and Concentration at Pilot-Scale from North Dakota Coal-Related Feedstocks (Final Technical Report)

The objectives of this project were to design, construct, commission, and operate a pilot-scale system utilizing UND's REE extraction technology from lignite, and complete saleability and economic evaluations of products. The process includes a dilute-acid extraction process from low-rank-coals, followed by selective precipitations and further processing to produce mixed rare earth oxide materials. The pilot was successfully constructed to a 1,000 lb/hr nameplate capacity and tested with over 100 tons of >300-ppm lignite-based feedstocks and produced saleable-quality products during operation. The team successfully attained a TRL status of 6 with the completion and testing of the pilot system, and the technology is poised for demonstration at a commercial scale.

01 COAL, LIGNITE, AND PEAT↗

Field Testing of Activated Carbon Injection Options for Mercury Control at TXU's Big Brown Station

The primary objective of the project was to evaluate the long-term feasibility of using activated carbon injection (ACI) options to effectively reduce mercury emissions from Texas electric generation plants in which a blend of lignite and subbituminous coal is fired. Field testing of ACI options was performed on one-quarter of Unit 2 at TXU's Big Brown Steam Electric Station. Unit 2 has a design output of 600 MW and burns a blend of 70% Texas Gulf Coast lignite and 30% subbituminous Powder River Basin coal. Big Brown employs a COHPAC configuration, i.e., high air-to-cloth baghouses following cold-side electrostatic precipitators (ESPs), for particulate control. When sorbent injection is added between the ESP and the baghouse, the combined technology is referred to as TOXECON{trademark} and is patented by the Electric Power Research Institute in the United States. Key benefits of the TOXECON configuration include better mass transfer characteristics of a fabric filter compared to an ESP for mercury capture and contamination of only a small percentage of the fly ash with AC. The field testing consisted of a baseline sampling period, a parametric screening of three sorbent injection options, and a month long test with a single mercury control technology. During the baseline sampling, native mercury removal was observed to be less than 10%. Parametric testing was conducted for three sorbent injection options: injection of standard AC alone; injection of an EERC sorbent enhancement additive, SEA4, with ACI; and injection of an EERC enhanced AC. Injection rates were determined for all of the options to achieve the minimum target of 55% mercury removal as well as for higher removals approaching 90%. Some of the higher injection rates were not sustainable because of increased differential pressure across the test baghouse module. After completion of the parametric testing, a month long test was conducted using the enhanced AC at a nominal rate of 1.5 lb/Macf. During the time that enhanced AC was injected, the average mercury removal for the month long test was approximately 74% across the test baghouse module. ACI was interrupted frequently during the month long test because the test baghouse module was bypassed frequently to relieve differential pressure. The high air-to-cloth ratio of operations at this unit results in significant differential pressure, and thus there was little operating margin before encountering differential pressure limits, especially at high loads. This limited the use of sorbent injection as the added material contributes to the overall differential pressure. This finding limits sustainable injection of AC without appropriate modifications to the plant or its operations. Handling and storage issues were observed for the TOXECON ash-AC mixture. Malfunctioning equipment led to baghouse dust hopper plugging, and storage of the stagnant material at flue gas temperatures resulted in self-heating and ignition of the AC in the ash. In the hoppers that worked properly, no such problems were reported. Economics of mercury control at Big Brown were estimated for as-tested scenarios and scenarios incorporating changes to allow sustainable operation. This project was funded under the U.S. Department of Energy National Energy Technology Laboratory project entitled 'Large-Scale Mercury Control Technology Field Testing Program--Phase II'.

01 COAL, LIGNITE, AND PEAT↗

JV Task 119 - Effects of Aging on Treated Activated Carbons

For both the United States and Canada, testing has been under way for electric utilities to find viable and economical mercury control strategies to meet pending future mercury emission limits. The technology that holds the most promise for mercury control in low-chlorine lignite to meet the needs of the Clean Air Act in the United States and the Canada-Wide Standards in Canada is injection of treated activated carbon (AC) into the flue gas stream. Most of the treated carbons are reported to be halogenated, often with bromine. Under a previous multiyear project headed by the Energy & Environmental Research Center (EERC), testing was performed on a slipstream unit using actual lignite-derived flue gas to evaluate various sorbent technologies for their effectiveness, performance, and cost. Testing under this project showed that halogenated ACs performed very well, with mercury capture rates often {ge} 90%. However, differences were noted between treated ACs with respect to reactivity and capacity, possibly as a result of storage conditions. Under certain conditions (primarily storage in ambient air), notable performance degradation had occurred in mercury capture efficiency. Therefore, a small exploratory task within this project evaluated possible differences resulting from storage conditions and subsequent effects of aging that might somehow alter their chemical or physical properties. In order to further investigate this potential degradation of treated (halogenated) ACs, the EERC, together with DOE's National Energy Technology Laboratory, the North Dakota Industrial Commission (NDIC), the Electric Power Research Institute (EPRI), SaskPower, and Otter Tail Power Company, assessed the aging effects of brominated ACs for the effect that different storage durations, temperatures, and humidity conditions have on the mercury sorption capacity of treated ACs. No aging effects on initial capture activity were observed for any carbons or conditions in the investigation. As measured by the 50% breakthrough time, no changes in capacity were observed for Norit LH samples stored frozen and likely none for Norit LH samples stored under high humidity conditions. The major aging effects on capacity for the EERC brominated sample were seen as a decrease in capacity during the first week of storage under high humidity conditions. Storage of the Norit LH and the EERC 5% brominated samples under low humidity conditions resulted in slightly improved capacities. Storage of the 15% brominated sample under high humidity conditions also improved the capacity. Surface analysis using x-ray photoelectron spectroscopy (XPS) showed some migration of bromine to and from the surface occurred during storage, although no net loss of bromine was observed. The migration to the surface in the case of the 15% brominated carbon correlates with the increased capacity observed for this sample. The XPS elemental speciation data for the EERC brominated carbons showed a trend toward more bromide being formed at the expense of covalent bromine during storage. This was especially great for the 15% and the 5% stored in low humidity. The Norit LH samples did not show this increase in bromide concentration. This is consistent with the lack of change in capacity for the Norit LH during storage. The carbon speciation data showed generally more oxidization of carbon surfaces with storage, especially formation of carboxylate groups. The least increase in carboxylate groups was seen for the Norit LH stored under low humidity, which correlates with its increased capacity. In conclusion, the observed changes in surface chemistry can be related to the minimal changes in capacity observed, but the factors operate in different directions, so the relationships are complex. High-quality x-ray absorption fine structure spectra were obtained for most of the samples. Significant changes were observed in the x-ray absorption near edge structure and extended x-ray absorption fine structure spectra of the stored carbons, but proved difficult to interpret and correlate with structural changes.