At least 73 records · Page 4

The Nimbus 7 LIMS map archival tape

The development of the Langley Map Archival Tape (LAMAT) is described. The role of the Nimbus 7 orbit characteristics in the analysis and interpretation of LAMAT data is discussed. The pressure ranges and heights for the LAMAT components are given and the synoptic fields for each pressure and latitude were modeled as Fourier series in longitude with time-dependent coefficients. Examples of LAMAT temperature fields are presented and the accuracies of the LAMAT fields are evaluated. The fit between the Langley inverted profile archival tape (LAIPAT) and LAMAT is examined by comparing averaged zonal mean fields and standard deviations. Consideration is given to diurnal variations of LAIPAT data, and the time and spatial smoothing of the data.

Haggard, K. V.↗

The water vapour budget of the stratosphere studied using LIMS and SAMS satellite data

Monthly zonal mean observations of H2O and CH4 made by the limb infrared monitor of the stratosphere and the stratospheric and mesospheric sounder instruments on Nimbus 7 have been used to investigate whether the H2O mixing ratios in the stratosphere are consistent with a source via the oxidation of CH4. While both sets of data show considerable seasonally varying structure, total hydrogen (neglecting molecular hydrogen) is relatively featureless with a mean value over the stratosphere of 6.0 + or - 0.35 ppmm(1sigma) for the five-month period studied. The uniformity of the total hydrogen fields points to the validity of the CH4 oxidation hypothesis. The derived fields of total hydrogen are used to deduce a mean H2O mixing ratio for air as it enters the stratosphere of 2.7 + or - 0.35 ppmv (1sigma) from which a desiccation temperature may be deduced.

Jones, R. L.↗

Equatorial semiannual oscillation in zonally averaged temperature observed by the Nimbus 7 SAMS and LIMS

Zonally averaged equatorial temperatures obtained aboard Nimbus 7 by the stratospheric and mesospheric sounder (SAMS) are compared to comparable data obtained from the limb IR monitor of the stratosphere. The SAMS data are shown to confirm the seasonal asymmetry in semiannual wind regimes previously noted in rocketsonde observations near the equator. Two explanations for the asymmetry are considered: (1) an improved Kelvin and gravity wave transmissivity in stronger equatorial easterlies (resulting from planetary Rossby wave momentum transport), implying stronger westerly mean flow acceleration in the first cycle than in the second; and (2) evidence of strong polar-tropical coupling in the northern winter indicating that mean meridional circulations are present on a global scale.

Delisi, Donald P.↗

Time series comparisons of satellite and rocketsonde temperatures in 1978-1979

The Limb Infrared Monitor of the Stratosphere (LIMS) experiment on Nimbus 7 yielded temperature-versus-pressure (T(p)) profiles for each radiance scan. The present report describes time series comparisons between LIMS and rocketsonde T(p) values at rocketsonde station locations. Sample size has increased up to 665 by this new approach, leading to better statistics for a T(p) validation. The results indicate no clearly significant bias for LIMS versus Datasonde from 10 kPa at low and mid latitudes. There is a positive LIMS bias of 2 to 3 K in the upper stratosphere at high latitudes for the Northern Hemisphere in both winter and spring. LIMS is progressively colder than Datasonde from 0.4 kPa (about -3 K) to 0.1 kPa (about -9 K) at all latitudes. A similar comparison between LIMS and the more accurate falling sphere measurements reveals an equivalent mid-latitude LIMS bias at 0.4 kPa but a much smaller bias at 0.1 kPa (-4.6 K). Because the biases do not vary noticeably with season, it is concluded that they are not a function of atmospheric state. This result confirms the robustness of the LIMS temperature retrieval technique.

Remsberg, Ellis E.↗

Preliminary Results of the Third Test Series of Nonmetal Material Flammability Evaluation In SKOROST Apparatus on the Space Station Mir

The work has been done according to the US/Russian Joint Project "Experimental Evaluation of the Material Flammability in Microgravity" a continued combustion study in the SKOROST test apparatus on the OS Mir. The objective of the project was to evaluate the flammability and flame-spread rate for the selected polymer materials in low velocity flow in microgravity. Lately, the issue of nonmetal material combustion in microgravity has become of great importance, based on the necessity to develop the fire safety system for the new International Space Station (ISS). Lack of buoyant flow in microgravity reduces oxygen transfer into the combustion zone, which leads to flame extinction when the flow velocity is less than the limiting flow velocity V(sub lim) for the material. The ISS FGB fire-safety system was developed based on this phenomenon. The existence of minimum flow velocity V(sub lim) to sustain fire for the selected materials was determined both theoretically and experimentally. In the latter, it is shown that, even for thermally thin nonmetal materials with a very low oxygen index C(sub lim) of 12.5% (paper sheets with the thickness of 0.1 mm), a limiting flow velocity V(sub lim) exists at oxygen concentration Co(sub OX) = 17-21%, and is about 1.0 - 0.1 cm/sec. This might be explained by the relative increase in thermal losses due to radiation from the surface and from the gaseous phase. In the second series of experiments in Skorost apparatus on Orbital Station Mir the existence of the limiting flow velocity V(sub lim) for combustion was confirmed for PMMA and glass-epoxy composite strip samples 2 mm thick at oxygen concentration C(sub OX) = 21.5%. It was concluded that V(sub lim) depends on C(sub OX) for the PMMA sample with a low oxygen index of 15.5%, the limiting flow velocity V(sub lim) was less than 0.5 cm/sec, and for the glass-epoxy composite sample with a high oxygen index of 19%, the limiting flow velocity V(sub lim) was higher than 15 cm/sec. As of now only those materials that maintain their integrity during combustion were investigated. The materials that disintegrate when burning present more danger for fire safety because the flame can spread farther with the parts of the structure, ejected melt drops, et cetera. Materials such as polyethylene are of great interest since they form a lengthy melt zone during the combustion in normal gravity. This melt zone generates drops of liquids that promote faster flame spread compared to usual combustion. The preliminary results of polyethylene insulation flammability evaluation in microgravity are shown in the NASA Wire Insulation Flammability (WIF) experiment during Space Shuttle flight STS-50. A lot of interesting data was collected during the WIF test program. However, one of the most important results was that, in microgravity, the extinction of the polyethylene occurred almost immediately when the flow of relatively low oxygen concentration (C(sub OX)=21%) was stopped. The purpose of the work reported here is to expand the existing data base on material flammability in microgravity and to conduct the third series of the space experiment using Skorost apparatus on Orbiatl Station Mir with melting polymers, which might increase the probability of fire and its propagation in ventilated microgravity environment of orbiting spacecraft.

Ivanov, A. V.↗

Laser microprobe characterization of C species in Interplanetary Dust Particles (IDP)

Preliminary results of a study whose aim is the characterization of carbon (C) species in microvolumes of materials by means of laser ionization mass spectrometry (LIMS) are presented. The LIMS instrument employs a pulsed UV laser to produce nearly instantaneous vaporization and ionization of materials, followed by acceleration and time-of-flight analysis of the ions produced. LIMS provides a survey technique with nearly simultaneous acquisition of mass spectra covering the entire elemental range. The main limitation of the LIMS technique at present is its limited ability to perform quantitative analysis, due in part to insufficient knowledge of the mechanism of laser-solid interaction. However, considerable effort is now being directed at making LIMS a more quantitative technique. A variety of different C samples, both natural and man made were analyzed to establish the ability of LIMS to differentiate among the various C phases. The results of preliminary analyses performed on meteoritical and interplanetary dust samples are also presented. The C standards selected for the LIMS characterization range from essentially amorphous soot to diamond, which exhibits the highest degree of ordering.

Dibrozolo, F. R.↗

Limb Infrared Monitor of the Stratosphere /LIMS/ experiment

The Limb Infrared Monitor of the Stratosphere (LIMS) radiometer is a satellite-borne six-channel multispectral scanning radiometer using a two-stage methane and ammonia solid-cryogen cooler to cool the (Hg, Cd)Te focal plane to 65 K. The LIMS experiment employs thermal IR limb sounding to provide vertical-profile measurement of temperature and of concentrations of O3, NO3, and H2O in the stratosphere on a global scale. The goals of the experiment and the expected accuracies of the measurements are outlined, and the radiance measured by the radiometer is analyzed. A program of correlative measurements designed for verification and augmentation of the LIMS data is discussed. Detailed descriptions are given of the LIMS components and optics, the detector capsule assembly, the solid-cryogen cooler, the four operational modes of the LIMS system, and the data-processor electronics. It is noted that prelaunch acceptance testing thus far completed indicates that the LIMS specification design requirements have been met, and the experiment's performance goals can be achieved.

Drozewski, R. W.↗

Validation of water vapor results measured by the Limb Infrared Monitor of the Stratosphere experiment on Nimbus 7

In the LIMS experiment using thermal IR limb scanning to sound the composition and structure of the upper atmosphere, one of the LIMS channels was spectrally centered at 6.9 micrometers to measure the vertical profile and global distribution of stratospheric water vapor. This channel's characteristics, the data from it, and the steps taken to validate results are described. The mean difference between the LIMS measurements and data from 13 balloon underflights is about 0.6 ppmv with LIMS mixing ratios biased high; this difference is of about the same order as estimated LIMS accuracy and less than the sum of the errors for LIMS and the balloon techniques. In-orbit precision is 0.2-0.3 ppmv and accuracy is estimated at 20-30 percent from 50 mbar to the stratopause. An unexplained diurnal variation exists in the vertical profile data which is largest at the 1-mbar level and virtually nonexistent at 10 mbar; day values are higher than night. More confidence is placed in zonal mean distributions averaged over several days than in single profiles. A zonal mean pressure-latitude cross section is described for January 5-9, 1979.

Russell, J. M., III↗

A comparison of Nimbus 7 limb infrared monitor of the stratosphere and radiosonde temperatures in the lower stratosphere poleward of 60N

The quality of the more widely used, mapped version of the LIMS temperature data set (LAMAT) is assessed for the polar lower stratosphere by comparison with lower stratospheric radiosonde (RAOB) temperatures at a set of 22 stations. Average LIMS minus uncorrected RAOB values are within +/-0.3 K at 30, 50, and 70 hPa, and -1.2 +/-2.2 K at 100 hPa. The generally excellent LIMS/RAOB temperature comparisons at 10 to 70 hPa support the contention that there are no significant temperature bias errors in the LIMS constituent distributions for polar regions. LIMS minus RAOB differences at 100 hPa are slightly negative for the present station set, in agreement with that found by Grose et al. (1988). The month-by-month LIMS minus RAOB analysis at 100 hPa showed that LIMS is -1.9 +/-1.8 K too cold in November and December.

Remsberg, Ellis E.↗

Sensitivity of calculated odd nitrogen distributions to the diabatic wind fields

This paper compares atmospheric total odd nitrogen and ozone computed with two different advective wind fields, one using climatological averages of ozone and temperature to obtain monthly averaged horizontal and vertical winds and the other using measurements from the LIMS instrument. Calculations using the former data show stronger poleward and downward motion in the winter season compared to those using the LIMS data. This leads to NO(y) mixing ratios in the lower stratosphere that are about 20 percent larger in the polar regions of both hemispheres and about 40 percent higher in the equatorial region for climatological transport fields compared to those derived from LIMS data. Consequently, the NO(y) distributions calculated with the LIMS advective field show worse agreement with the NO(y) values inferred from the LIMS measurements than similar results obtained with the climatological wind field.

Boughner, R. E.↗

Analysis of observations of the middle atmosphere from satellites

Satellite data are being used to investigate problems in middle atmosphere chemistry and dynamics. Efforts have been focused primarily on studies to determine the quality of observed distributions of trace species and derived dynamical quantities. Those data have been used as diagnostics for model-derived constituent profiles and fields and for improving our understanding of some of the fundamental processes occurring in the middle atmosphere. Temperatures and derived winds from Nimbus 7 Limb Infrared Monitoring of the Stratosphere (LIMS) data were compared with long-time series of rawinsonde data at Invercargill, New Zealand, and Berlin, West Germany, and the results are excellent for both quantities. It was also demonstrated that more highly-derived dynamical quantities can be obtained reliably from those LIMS fields. Furthermore, both the diabatic and residual-mean circulations derived using LIMS data agree qualitatively with changes in the distribution of trace species determined independently with the Nimbus 7 SAMS and LIMS experiments. Subsequently, an examination of LIMS data at mid to high latitudes of the Southern Hemisphere has revealed a synoptic-scale, upper stratospheric instability during late autumn that is associated with the development of the stratospheric polar jet. Investigation of this phenomenon continues with Stratospheric Sounding Unit (SSU) data sets.

Remsberg, Ellis E.↗

Satellite observation and mapping of wintertime ozone variability in the lower stratosphere

Comparison is made between 30 mbar ozone fields that are generated by a transport chemistry model utilizing the winds from the Goddard Space Flight Center stratospheric data assimilation system (STRATAN), observations from the LIMS instrument on Nimbus-7, and the ozone fields that result from 'flying a mathematical simulation of LIMS observations through the transport chemistry model ozone fields. The modeled ozone fields were found to resemble the LIMS observations, but the model fields show much more temporal and spatial structure than do the LIMS observations. The 'satellite mapped' model results resemble the LIMS observations much more closely. These results are very consistent with the earlier discussions of satellite space-time sampling by Salby.

Geller, Marvin A.↗

Satellite observation and mapping of wintertime ozone variability in the lower stratosphere

Comparison is made between 30 mbar ozone fields that are generated by a transport chemistry model utilizing the winds from the Goddard Space Flight Center stratospheric data assimilation system (STRATAN), observations from the LIMS instrument on Nimbus-7, and the ozone fields that result from 'flying' a mathematical simulation of LIMS observations through the transport chemistry model ozone fields. The modeled ozone fields were found to resemble the LIMS observations, but the model fields show much more temporal and spatial structure than do the LIMS observations. The 'satellite mapped' model results resemble the LIMS observations much more closely. These results are very consistent with the earlier discussions of satellite space-time sampling by Salby.

Geller, M. A.↗

The accuracy of temperature distributions used to derive the net transport for a zonally averaged model

Comparisons of satellite-derived temperatures with correlative temperatures indicate that the LIMS temperatures are accurate and contain more of the needed vertical resolution for calculating a residual mean circulation for transporting tracer-like species. Generally, the LIMS temperatures are accurate to at least 2 K. Other satellite data sets are comprised of temperatures with coarser vertical resolution, leading to biases that occur with an error pattern that is characteristic of their resolution. Their biases exceed 2 K at some altitudes. Retrievals of species using an infrared limb emission technique are sensitive to any temperature bias. Generally, the IMS comparisons with other data sets for ozone and water vapor are good to better than 20 percent; this represents an independent confirmation of the quality of LIMS and temperatures. Zonal mean comparisons between LIMS and SAMS temperatures also indicate agreement to better than 2 K from about 7 to 2hPa. Therefore, we are confident that SAMS N2O and CH4 are relatively free of temperature bias in that region. These factors support the generally good agreement in G90 between model N2O transported using a LIMS-derived RMC and the N2O contours from SAMS.

Remsberg, Ellis E.↗

On the determination of biases in satellite-derived temperature profiles

Comparisons are presented between Nimbus 7 LIMS (Limb Infrared Monitor of the Stratosphere) mapped temperatures and both Datasonde and sphere in situ rocketsonde temperature measurements. With this approach up to 666 LIMS/Datasonde pairs were obtained for various pressure levels to look for small biases in LIMS temperatures as a function of altitude, latitude and season. Between 10-1 hPa LIMS and Datasonde agree everywhere to better than +/- 2 K with the exception of a warm bias of about 3 K at 2 hPa at high latitudes. However, LIMS is colder than the Datasonde by about 4 K at 0.4 hPa and by about 8-10 K at 0.1 hPa. When compared with the more accurate sphere temperatures the bias at 0.1 hPa is reduced by nearly one-half. These results indicate that the LIMS zonal mean constituent profiles are nearly free of temperature bias, except perhaps at 0.1 hPa.

Bhatt, Praful P.↗

Inversion of limb radiance measurements - An operational algorithm

The limb radiance inversion radiometer (LRIR) and limb infrared monitor of the stratosphere (LIMS) experiments aboard the Nimbus 6 and 7 spacecraft have made observations of infrared emission by CO2, O3, H2O, HNO3, and NO2 at the earth's limb. This paper describes a method by which such measurements can be inverted to give vertical distributions of temperature and mixing ratios as functions of pressure. The simple and efficient approach was successfully applied to the LRIR data and subsequently in the initial assessment of the LIMS data. Inversion of synthetic data indicates the size of the errors to be expected as a result of the assumptions and instrumental errors. Retrievals of measured LIMS radiances are shown as examples and compared to in situ observations. The differences are comparable to those obtained with the more complex retrieval scheme used to process the LIMS archival products. Some problems are noted.

Bailey, P. L.↗

Ground-based microwave observations of ozone in the upper stratosphere and mesosphere

A 9-month-long series of mesurements of ozone in the upper stratosphere and mesosphere is reported. The measurements are presented as monthly averages of profiles in blocks of roughly 20 min local time and as night-to-day ratios. An error analysis predicts accuracies of 5-26% for the monthly profiles and 2.5-9% for the ratios. The data are compared to historical data from Solar Mesosphere Explorer (SME) and limb infrared monitor of the stratosphere (LIMS), and it is shown how to remove the effect of different vertical resolution from the comparisons. The microwave data typically agree to better than 10% with SMF and nighttime LIMS ozone at all altitudes below the 0.1-mbar surface. Comparison of the microwave night-to-day ratio with the corresponding ratio from LIMS suggests that nonlocal thermodynamic equilibrium effects in the LIMS daytime data exceed 10% at all pressures less than or equal to 1 mbar.

Connor, Brian J.↗

Atmospheric Effects of Energetic Particle Precipitation in the Arctic Winter 1978-1979 Revisited

The Limb Infrared Monitor of the Stratosphere (LIMS) measured polar stratospheric enhancements of NO2 mixing ratios due to energetic particle precipitation (EPP) in the Arctic winter of 1978-1979. Recently reprocessed LIMS data are compared to more recent measurements from the Michelson Interferometer for Passive Atmospheric Sounding (MIPAS) and the Atmospheric Chemistry Experiment Fourier transform spectrometer (ACE-FTS) to place the LIMS measurements in the context of current observations. The amount of NOx (NO + NO2) entering the stratosphere that has been created by EPP in the mesosphere and lower thermosphere (EPP-NOx) has been quantified for the 1978-1979 and 2002-2003 through 2008-2009 Arctic winters. The NO2 enhancements in the LIMS data are similar to those in MIPAS and ACE-FTS data in the Arctic winters of 2002-2003, 2004-2005, 2006-2007, and 2007-2008. The largest enhancement by far is in 2003-2004 (approximately 2.2 Gmol at 1500 K), which is attributed to a combination of elevated EPP and unusual dynamics that led to strong descent in the upper stratosphere/lower mesosphere in late winter. The enhancements in 2005-2006 and 2008-2009, during which large stratospheric NOx enhancements were caused by a dynamical situation similar to that in 2003 2004, are larger than in all the other years (except 2003-2004) at 3000 K. However, by 2000 K the enhancements in 2005-2006 (2008-2009) are on the same order of magnitude as (smaller than) all other years. These results highlight the importance of the timing of the descent in determining the potential of EPP-NOx for reaching the middle stratosphere.

Holt, L. A.↗