At least 73 records · Page 4

Liquid Nitrogen Testing of an Integrated Reaction Control System

Integrated Reaction Control Systems (IRCS) are considered an enabling technology for future human exploration of the solar system. An IRCS uses the same fuel and oxidizer as the main propulsion system, allowing for increased performance and simplified cryogenic fluid management operations. The IRCS team at Marshall Spaceflight Center is currently evaluating an IRCS system that uses a combination of electric pumps and pressure-regulation devices to provide a constant flow of conditioned propellant to a thruster bank during operation. In contrast to accumulator and gasifier designs, the recirculation loop design is less massive and can provide large, sustained flowrates to the thruster inlet. In the summer 2021 test series presented herein, the feasibility of this concept was evaluated using liquid nitrogen as a simulant for liquid oxygen. The goals of this test series were to demonstrate the ability of the pump and pressure regulator to maintain adequate thruster inlet conditions during transient operation, and to demonstrate the ability for the system to operate in an “idle mode” that maintains system chill between activations. During test operations, the back-pressure regulator responded more slowly than the opening/closing of valves in the thruster simulant, but it was still able to attenuate the pressure fluctuation at the pump discharge and ensure a stable flowrate through the pump. Similarly, the pump was able to be run far below its nominal operating point and successfully flow sufficient fluid to maintain chill conditions.

RCS↗

Liquid Nitrogen Testing of An Integrated Reaction Control System

Integrated Reaction Control Systems (IRCS) are considered an enabling technology for future human exploration of the solar system. An IRCS uses the same fuel and oxidizer as the main propulsion system, allowing for increased performance and simplified cryogenic fluid management operations. The IRCS team at Marshall Spaceflight Center is currently evaluating an IRCS system that uses a combination of electric pumps and pressure-regulation devices to provide a constant flow of conditioned propellant to a thruster bank during operation. In contrast to accumulator and gasifier designs, the recirculation loop design is less massive and can provide large, sustained flowrates to the thruster inlet. In the summer 2021 test series presented herein, the feasibility of this concept was evaluated using liquid nitrogen as a simulant for liquid oxygen. The goals of this test series were to demonstrate the ability of the pump and pressure regulator to maintain adequate thruster inlet conditions during transient operation, and to demonstrate the ability for the system to operate in an “idle mode” that maintains system chill between activations. During test operations, the back-pressure regulator responded more slowly than the opening/closing of valves in the thruster simulant, but it was still able to attenuate the pressure fluctuation at the pump discharge and ensure a stable flowrate through the pump. Similarly, the pump was able to be run far below its nominal operating point and successfully flow sufficient fluid to maintain chill conditions.

RCS↗

Liquid Nitrogen Testing of an Integrated Reaction Control System

Integrated Reaction Control Systems (IRCS) are considered an enabling technology for future human exploration of the solar system. An IRCS uses the same fuel and oxidizer as the main propulsion system, allowing for increased performance and simplified cryogenic fluid management operations. The IRCS team at Marshall Spaceflight Center is currently evaluating an IRCS system that uses a combination of electric pumps and pressure-regulation devices to provide a constant flow of conditioned propellant to a thruster bank during operation. In contrast to accumulator and gasifier designs, the recirculation loop design is less massive and can provide large, sustained flowrates to the thruster inlet. In the summer 2021 test series presented herein, the feasibility of this concept was evaluated using liquid nitrogen as a simulant for liquid oxygen. The goals of this test series were to demonstrate the ability of the pump and pressure regulator to maintain adequate thruster inlet conditions during transient operation, and to demonstrate the ability for the system to operate in an “idle mode” that maintains system chill between activations. During test operations, the back-pressure regulator responded more slowly than the opening/closing of valves in the thruster simulant, but it was still able to attenuate the pressure fluctuation at the pump discharge and ensure a stable flowrate through the pump. Similarly, the pump was able to be run far below its nominal operating point and successfully flow sufficient fluid to maintain chill conditions.

integrated RCS↗

Liquid Nitrogen Testing of an Integrated Reaction Control System

Integrated Reaction Control Systems (IRCS) are considered an enabling technology for future human exploration of the solar system. An IRCS uses the same fuel and oxidizer as the main propulsion system, allowing for increased performance and simplified cryogenic fluid management operations. The IRCS team at Marshall Spaceflight Center is currently evaluating an IRCS system that uses a combination of electric pumps and pressure-regulation devices to provide a constant flow of conditioned propellant to a thruster bank during operation. In contrast to accumulator and gasifier designs, the recirculation loop design is less massive and can provide large, sustained flowrates to the thruster inlet. In the summer 2021 test series presented herein, the feasibility of this concept was evaluated using liquid nitrogen as a simulant for liquid oxygen. The goals of this test series were to demonstrate the ability of the pump and pressure regulator to maintain adequate thruster inlet conditions during transient operation, and to demonstrate the ability for the system to operate in an “idle mode” that maintains system chill between activations. During test operations, the back-pressure regulator responded more slowly than the opening/closing of valves in the thruster simulant, but it was still able to attenuate the pressure fluctuation at the pump discharge and ensure a stable flowrate through the pump. Similarly, the pump was able to be run far below its nominal operating point and successfully flow sufficient fluid to maintain chill conditions.

integrated RCS↗

Test data analysis of the thermodynamic vent system-augmented top spray injector liquid nitrogen transfer experiments

Traditionally, a cryogenic tank must be pre-chilled to some “target” temperature before the main vent valve can be closed to attempt a non-vented fill (NVF) of cryogenic liquid propellant. This methodology is particularly attractive for performing in-space transfer of cryogens due to the unknown location of the liquid/vapor interface in microgravity and the high likelihood of venting liquid if the vent valve is opened during transfer. This paper presents in-depth test data analysis of a Thermodynamic Vent System (TVS) augmented injector used for cryogenic tank chilldown and fill experiments of a thin-walled Titanium tank. Eight tests were conducted using liquid nitrogen across a range of inlet conditions and boundary conditions, and three different chilldown/fill methods. For four of the tests, the injector sprays liquid into the tank as normal, but also uses a TVS heat exchanger to cool the metallic injector itself as well as the main incoming liquid stream. Results show that using the TVS augmented injector simplifies transfer operation via enhanced condensation at the injector surface at the cost of sacrificing only a small amount of propellant.

No-vent Fill↗

Liquid Nitrogen (Oxygen Simulent) Thermodynamic Venting System Test Data Analysis

In designing systems for the long-term storage of cryogens in low gravity space environments, one must consider the effects of thermal stratification on excessive tank pressure that will occur due to environmental heat leakage. During low gravity operations, a Thermodynamic Venting System (TVS) concept is expected to maintain tank pressure without propellant resettling. The TVS consists of a recirculation pump, Joule-Thomson (J-T) expansion valve, and a parallel flow concentric tube heat exchanger combined with a longitudinal spray bar. Using a small amount of liquid extracted by the pump and passing it though the J-T valve, then through the heat exchanger, the bulk liquid and ullage are cooled, resulting in lower tank pressure. A series of TVS tests were conducted at the Marshall Space Flight Center using liquid nitrogen as a liquid oxygen simulant. The tests were performed at fill levels of 90%, 50%, and 25% with gaseous nitrogen and helium pressurants, and with a tank pressure control band of 7 kPa. A transient one-dimensional model of the TVS is used to analyze the data. The code is comprised of four models for the heat exchanger, the spray manifold and injector tubes, the recirculation pump, and the tank. The TVS model predicted ullage pressure and temperature and bulk liquid saturation pressure and temperature are compared with data. Details of predictions and comparisons with test data regarding pressure rise and collapse rates will be presented in the final paper.

Hedayat, A.↗

Preliminary study of gaseous nitrogen-liquid oxygen mixing and self cleaning

The penetration of gaseous nitrogen into liquid oxygen at a pressure of 150 psi was determined by monitoring the composition of the evaporating liquid in a nitrogen analyzer. For pressurization times of about 1 hr the penetration depth varies between 0.0024 and 0.018 in. at an evaporation rate of about 1 gal/day. These are small compared to the penetration depth of 22.2 in. measured in the 7-inch high temperature tunnel at a pressure of 1500 psi, pressurization time of 5 min, and evaporation rate of 121 gal/day.

Zuckerwar, A. J.↗

Three-Dimensional CFD Simulations in the Film Boiling Regime During Liquid Nitrogen Chilldown Process

The paper presents a three-dimensional CFD simulation for predicting the liquid nitrogen chilldown process through a SS-304 tube. A dispersed mixture model has been employed to predict the two-phase flow behavior whereas the Lee phase change model has been used to predict the boiling process. Cryogenic chilldown process starts with a pure vapor region and proceeds to film, transition and nucleate boiling regimes before reaching the single phase liquid flow and complete chilldown of the transfer line. The present numerical model predicted the film boiling regime accurately and the slope of the chilldown curve deviates slightly from the experimental curve towards the transition and nucleate boiling regime, which needs further investigation. The contours of liquid volume fraction and temperature profiles has been presented to understand the inverted annular film flows in the film boiling regime in detail. In future, the present CFD model will be extended to a wide range of chilldown conditions and different cryogenic fluids to develop a robust methodology.

CFD↗

Polystyrene cryostat facilitates testing tensile specimens under liquid nitrogen

Lightweight cryostat made of expanded polystyrene reduces eccentricity in a tensile system being tested under liquid nitrogen. The cryostat is attached directly to the tensile system by a special seal, reducing misalignment effects due to cryostat weight, and facilitates viewing and loading of the specimens.

Shogan, R. P.↗

Specific cooling capacity of liquid nitrogen

The assumed cooling process and the method used to calculate the specific cooling capacity of liquid nitrogen are described, and the simple equation fitted to the calculated specific cooling capacity data, together with the graphical form calculated values of the specific cooling capacity of nitrogen for stagnation temperatures from saturation to 350 K and stagnation pressures from 1 to 10 atmospheres, are given.

Kilgore, R. A.↗

Correlation of Helium Solubility in Liquid Nitrogen

A correlation has been developed for the equilibrium mole fraction of soluble gaseous helium in liquid nitrogen as a function of temperature and pressure. Experimental solubility data was compiled and provided by National Institute of Standards and Technology (NIST). Data from six sources was used to develop a correlation within the range of 0.5 to 9.9 MPa and 72.0 to 119.6 K. The relative standard deviation of the correlation is 6.9 percent.

VanDresar, Neil T.↗

Liquid-Nitrogen Test for Blocked Tubes

Nondestructive test identifies obstructed tube in array of parallel tubes. Trickle of liquid nitrogen allowed to flow through tube array until array accumulates substantial formation of frost from moisture in air. Flow stopped and warm air introduced into inlet manifold to heat tubes in array. Tubes still frosted after others defrosted identified as obstructed tubes. Applications include inspection of flow systems having parallel legs.

Wagner, W. R.↗

Liquid Nitrogen (Oxygen Simulant) Thermodynamic Vent System Test Data Analysis

In designing systems for the long-term storage of cryogens in low-gravity (space) environments, one must consider the effects of thermal stratification on tank pressure that will occur due to environmental heat leaks. During low-gravity operations, a Thermodynamic Vent System (TVS) concept is expected to maintain tank pressure without propellant resettling. A series of TVS tests was conducted at NASA Marshall Space Flight Center (MSFC) using liquid nitrogen (LN2) as a liquid oxygen (LO2) simulant. The tests were performed at tank til1 levels of 90%, 50%, and 25%, and with a specified tank pressure control band. A transient one-dimensional TVS performance program is used to analyze and correlate the test data for all three fill levels. Predictions and comparisons of ullage pressure and temperature and bulk liquid saturation pressure and temperature with test data are presented.

Hedayat, A.↗