Search NASA⌕ Search

SEARCH · Search NASA

Results for “LOADS, STEADY - WINGS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Multi-Physics System-level Simulations of a Generic Pebble Bed High-Temperature Gas Cooled Reactor with Coupled SAM/Griffin Model

A SAM model for a 200 MWth generic pebble bed high-temperature gas-cooled reactor (PBHTGR) is presented in this work. As an extension to the modeling effort from FY-22 (Ooi et al. (2022)), an improved core channel approach is used to model the pebble bed of the reactor. The improvement greatly simplifies the model and reduces the run time of the model. Furthermore, the SAM model is coupled to the Griffin reactor physics model from Stewart et al. (2021) using the MOOSE MultiApp system where neutronics calculations are performed by the Griffin model and thermal hydraulics calculations by the SAM model. Favorable predictions are produced by the SAM/Griffin coupled model for steady-state normal operating condition. A load-following transient is also simulated with the coupled model where the neutronics and thermal hydraulics responses of the core are predicted correctly by the model. A protected Pressurized Loss of Forced Cooling (PLOFC) accident is simulated with the SAM model, in which the reactor power is determined using the decay heat curve, and therefore the Griffin model is not needed and thus decoupled. A simplified RCCS (Reactor Cavity Cooling System) loop is added to the model to remove decay heat from the core during the transient. Qualitatively, the prediction by the SAM model matches the expected behavior of a PB-HTGR during a PLOFC accident.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Grid-Following Inverters and Synchronous Condensers: A Grid-Forming Pair?

As power systems across the globe continue to achieve higher instantaneous penetrations of power electronic converter-interfaced renewable sources, the stability of these power systems is challenged because of the removal of synchronous machines, from which stability is traditionally derived. Although technological solutions to these stability challenges are on the horizon, such as the use of grid-forming inverters, they are not yet widely applied to larger power systems, which presents operational challenges for power systems achieving these high instantaneous penetrations today. A potential interim solution using existing technologies is to pair synchronous condensers with grid-following inverters, which might prolong the stability of an operating power system while synchronous generators are turned off during periods of high renewable energy availability. This work examines the transient stability of such a solution using PSCAD simulations of a two-bus system coupled to a varied-length transmission line, with a synchronous condenser at one bus and a grid-following inverter with grid-support functionality at the other. The system is exposed to load step, balanced fault, and unbalanced fault perturbations. It was found that this simple system returned to a steady state for transmission line lengths up to 125 km after 10% load steps, or a variety of fault types.

grid-following inverters↗

Comprehensive Margin Assessment of the ASME Section III, Division 5, Class A Primary Load Design Rules

This report provides a comprehensive margin assessment of the ASME Section III, Division 5, Subsection HB, Subpart B rules for the design of high temperature reactor components against load controlled stress limits. These rules, often called the Code primary load design rules, provide protection against creep rupture and plastic collapse under steady conditions. The method adopted here is to compare the deterministic ASME design life, according to the primary load design rules, against the expected, statistical service life of the component, considering creep rupture as the relevant failure mode. The report provides the design margin of the ASME rules in terms of the probability of premature failure -- the probability that the component fails in service before reaching the ASME design life. To complete this assessment, the report describes the development of a statistical creep life assessment procedure accounting for variations in the component loading, material creep rate, and the material rupture time. This includes a novel method for correlating creep rupture data using a Gaussian process accounting for heat-to-heat variation in the Larson-Miller time-temperature parameter. The report applies the complete margin assessment process to quantify the design margin inherent in the ASME primary load design rules as a function of temperature for relevant component geometries and materials. The overall conclusion is that the ASME rules are conservative, providing designs with very small probability of premature failure, but some optimization of the Code design rules is possible to provide a more uniform design margin.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Grid-Following Inverters and Synchronous Condensers: A Grid-Forming Pair?: Preprint

As power systems across the globe continue to achieve higher instantaneous penetrations of power electronic converterinterfaced renewable sources, the stability of these power systems is challenged because of the removal of synchronous machines, from which stability is traditionally derived. Although technological solutions to these stability challenges are on the horizon, such as the use of grid-forming inverters, they are not yet widely applied to larger power systems, which presents operational challenges for power systems achieving these high instantaneous penetrations today. An interim solution using existing technologies is to pair synchronous condensers with grid-following inverters, which might prolong the stability of an operating power system while synchronous generators are turned off during periods of high renewable energy availability. This work examines the transient stability of such a solution using PSCAD simulations of a two-bus system coupled to a variedlength transmission line, with a synchronous condenser at one bus and a grid-following inverter with grid-support functionality at the other. The system is exposed to load step, balanced fault, and unbalanced fault perturbations. It was found that this simple system returned to a steady state for transmission line lengths up to 125 km after 10% load steps, or a variety of fault types.

14 SOLAR ENERGY↗

Utah FORGE: Fault Shear Reactivation Experimental Data for Fluid Injection-Rate Controls on Seismic Moment

Included are experimental data recorded from shear experiments that specifically explore the link between fluid-injection rate and seismic moment resulting from shear reactivation of laboratory faults. Raw mechanical data from three experiments are included alongside corresponding MATLAB scripts that import and plot the data, as well as use it to calculate shear and normal stress. Experiments are performed on 2.5-3 inch long granitoid cores from the Utah FORGE EGS demonstration site, containing a single inclined fracture with small-scale roughness added to the fracture surface. The raw data included here were recorded from an aluminum triaxial pressure vessel (TEMCO) configured with three independent servo-controlled pumps, with distilled water used as the working fluid. The pumps control confining pressure, upstream pore pressure, and axial pressure, with each pump connected to a LabView interface to record applied pressures, cumulative injected water volumes, and pump flow rates. The downstream outlet from the fracture is closed to allow pressurization, which is measured by an external pressure transducer. A linear variable differential transformer (LVDT) attached to the axial piston measures axial displacement, from which we calculate shear displacement along the fracture. Additionally, P-wave transducers are used to record acoustic signatures, where acoustic emission events and maximum amplitudes are compared against seismic moment and shear slip velocity. Fluid injection rates range between 0.05 mL/min, 0.25 mL/min, and 0.75 mL/min for each experiment. Along-fault pressure distributions are progressively less uniform as injection rates increase, representing a switch from steady-state to transient conditions. Triggered shear displacement is used as a proxy for seismic moment and is indexed against cumulative injection volume and rate. Each experiment is performed under constant shear stress conditions, and the sample is fully saturated with DI water. Axial and confining stresses are applied to 3 MPa through pressure-stepping in 500 kPa increments. The pore pressure is held constant at 200 kPa prior to initiating the experiment, and initial axial displacement is recorded. The axial stress is then increased to initiate shear mobilization during the loading phase (run-in) until a peak steady state is achieved. The initial shear stress is reduced to approximately 80% of the peak shear stress by decreasing the axial stress, then held constant for the duration of each experiment.

15 GEOTHERMAL ENERGY↗

Predicted Heat Flux Performance of Actively Cooled Tungsten-Armored Graphitic Foam Monoblocks

Tungsten (W)–armored graphitic foam monoblocks were developed for applications requiring high-Z plasma-facing material in long-pulse fusion experiments and ultimately deuterium-tritium fusion reactors. The monoblocks are an integrated material system combining the advantages of a chemical vapor deposited (CVD) W coating with a high-conductivity graphitic foam. The W is a high-melting-point, high-Z material with low tritium retention. The graphitic foam coupled to a swirl tube serves as a high-thermal-conductivity heat sink that cannot melt, although it can sublime at much higher temperatures than copper melts. Together, they comprise a robust plasma-facing component (PFC) weighing roughly 5% of an all-W component or 17% of a traditional W-coated copper heat sink.A single-channel mock-up consisting of four graphitic foam monoblocks equipped with a water-cooled swirl tube was fabricated for eventual testing in the 60-kW, EB-60, rastered electron beam at the Applied Research Laboratory of The Pennsylvania State University. Two monoblocks have a thin 50-μm-thick coating of pure W chemically vapor deposited over NbC and pure Nb interlayers. Two others have a 2-mm-thick pure W coating CVD on graphitic monoblocks using the same interlayers. The mock-up will be cooled with available 10 m/s, 0.7 MPa water with a 22°C inlet temperature and subjected to varying uniform heat loads up to 20 MW/m 2 . It is equipped with type-K thermocouples at various depths, and calibrated infrared thermography and spot pyrometry will be used to characterize the heated surface. Real-time water calorimetry will be used to ascertain the absorbed steady-state power and infer the heat flux during testing. Since testing cannot be done under prototypic divertor flow conditions, it is necessary to predict the thermal response of this novel PFC system and investigate the power sharing between radiation and convection at divertor heat flux levels and its inherent ability to avoid critical heat flux. Results are reported for predictions obtained from computational fluid dynamics models up to 30 MW/m 2 of steady-state uniform heat flux. Leading-edge heat loads of 30 MW/m 2 on a 2-mm-wide side strip were also investigated to ascertain if coating delamination is likely.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Steady-State Analysis of Microgrid Distributed Control Under Denial of Service Attacks

Distributed control is an effective method to coordinate multiple components in a microgrid. It usually has mandatory requirements for communication graph topology; changing the topology unexpectedly could disrupt the operation of a distributed controller. A denial of service (DoS) attack blocks communication channels to cause variations in communication graph. Unforeseen topology changes render a controller to receive incomplete system information. Control decisions made based on incorrect information can lead to significantly reduced grid supporting capability. As a result, the vital power balance between generation and load may be challenged. Determining power balance requires steady-state power flow analysis; however, the cyber-induced steady-state analysis is not well studied in the literature. Here, in this article, we show that a cyber–physical microgrid with unknown DoS attacks has augmented uncertain power flow equations, whose special structure creates new computational issue to determining power balance. To deal with the issue, we develop a novel cyber-induced microgrid model: the cyber–physical system is transformed into a pure physical model, where the disruption effects of DoS in the cyber layer are shown to be equivalent to the variations of the physical model parameters. With the transformed system, we develop a sufficient condition to ascertain the system power balance under unknown DoS attacks. In addition, practical insights for resilient distributed control design are shown as well.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Impact of the Cathode Pt Loading on PEMFC Contamination by Several Airborne Contaminants

Proton exchange membrane fuel cells (PEMFCs) with 0.1 and 0.4 mg Pt cm -2 cathode catalyst loadings were separately contaminated with seven organic species: Acetonitrile, acetylene, bromomethane, iso-propanol, methyl methacrylate, naphthalene, and propene. The lower catalyst loading led to larger cell voltage losses at the steady state. Three closely related electrical equivalent circuits were used to fit impedance spectra obtained before, during, and after contamination, which revealed that the cell voltage loss was due to higher kinetic and mass transfer resistances. A significant correlation was not found between the steady-state cell voltage loss and the sum of the kinetic and mass transfer resistance changes. Major increases in research program costs and efforts would be required to find a predictive correlation, which suggests a focus on contamination prevention and recovery measures rather than contamination mechanisms.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

An error-in-constitutive equations strategy for topology optimization for frequency-domain dynamics

This paper presents a topology optimization formulation for frequency-domain dynamics to reduce solution dependence upon initial guess and considered loading conditions. Due to resonance phenomena in undamped steady-state dynamics, objectives measuring dynamic response possess many local minima that may represent poor solutions to a design problem, an issue exacerbated for design with respect to multiple frequencies. In this work, we propose an extension of the modified error-in-constitutive-equations (MECE) method, used previously in material identification inverse problems, as a new approach for frequency-domain dynamics topology optimization to mitigate these issues. The main idea of the proposed framework is to incorporate an additional penalty-like term in the objective function that measures the discrepancy in the constitutive relations between stresses and strains and between inertial forces and displacements. Then, the design problem is cast within a PDE-constrained optimization formulation in which we seek displacements, stresses, inertial forces, and a density-field solution that minimize our new objective subject to conservation of linear momentum plus some additional constraints. We show that this approach yields superior designs to conventional gradient-based optimization approaches that solely use a functional of displacements as the objective, while strictly enforcing the constitutive equations. The MECE strategy integrates into a density-based topology optimization scheme for void–solid or two-phase material structural design. We highlight the merits of our approach in a variety of scenarios for direct frequency response design, considering multiple frequency load cases and structural objectives.

42 ENGINEERING↗

Load Margin Constrained Moving Target Defense against False Data Injection Attacks

Cyber physical security of power systems with high penetration of renewable generation has attracted attention from researchers. One critical issue is that cyber-physical attacks, disguised as uncertain renewable generation, can target conventional power system state estimation (SE). Moving target defense (MTD) is a promising defense strategy to detect stealthy false data injection (FDI) attacks against SE. However, all existing studies myopically perturb the reactance of transmission lines equipped with distributed flexible AC transmission system (D-FACTS) devices without adequately considering the system voltage stability. Exacerbated by the renewable generation uncertainty, existing MTD may cause voltage instability when the power grid is under stress. To address this issue, we propose a novel MTD framework that explicitly considers system voltage stability by using continuation power flow. We utilize the sensitivity matrix of power injection to line impedance, on which an optimization problem for maximizing load margin is formulated. This framework is validated on the IEEE 14-bus system and the IEEE 118-bus system, in which net load redistribution attacks are launched by sophisticated attackers. Steady-state simulations and dynamic simulations on PSS/E show the effectiveness of the proposed framework in circumventing the voltage instability while maintaining the detection effectiveness of MTD. The impact of the proposed method on attack detection effectiveness is also revealed.

Zhang, Hang↗

Deadband Voltage Control and Power Buffering for Extreme Fast Charging Station

Voltage fluctuation is one of the most common challenges that electric vehicle charging station (EVCS) may introduce to the power grid. Local reactive power compensation (Q-compensation) capability of bi-directional electric vehicle (EV) chargers can mitigate the steady-state voltage violations caused by the EV charging itself or changes in the neighboring loads. Power buffering, using energy storage system (ESS), can be utilized to address the voltage transients (sags and swells) as a result of EV charging at the EVCS. To address PI controller’s ‘hunting’ issue, this paper proposes a Q-sign triggered deadband voltage control (V-control) method at the point of common coupling (PCC). In addition, to ensure the ramp rate of EV charging is within the allowable limits set forth by the grid code, a ramp rate control is proposed that uses the ESS as a ‘power buffer’. Lastly, different from most reported work in the literature where no explicit limit of the power electronic converters (PECs) is considered, this work considers a reasonable apparent power capacity limit of the PECs when achieving the V-control. This limit also affects the amount of active power that can be obtained from the grid, and subsequently may require ESS to function as ‘load sharing’ device to provide supplemental active power to satisfy EV load. A case study simulated in MATLAB (interfaced with PLECS) is presented to demonstrate the effectiveness of the proposed approaches for EVCS operation.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Vertical-Axis Wind Turbine Steady and Unsteady Aerodynamics for Curved Deforming Blades

Vertical-axis wind turbines’ simpler design and low center of gravity make them ideal for floating wind applications. However, efficient design optimization of floating systems requires fast and accurate models. Low-fidelity vertical-axis turbine aerodynamic models, including double multiple streamtube and actuator cylinder theory, were created during the 1980s. Commercial development of vertical-axis turbines all but ceased in the 1990s until around 2010 when interest resurged for floating applications. Despite the age of these models, the original assumptions (2-D, rigid, steady, straight bladed) have not been revisited in full. When the current low-fidelity formulations are applied to modern turbines in the unsteady domain, aerodynamic load errors nearing 50% are found, consistent with prior literature. However, a set of steady and unsteady modifications that remove the majority of error is identified, limiting it near 5%. This paper shows how to reformulate the steady models to allow for unsteady inputs including turbulence, deforming blades, and variable rotational speed. A new unsteady approximation that increases numerical speed by 5–10× is also presented. Combined, these modifications enable full-turbine unsteady simulations with accuracy comparable to higher-fidelity vortex methods, but over 5000× faster.

17 WIND ENERGY↗

Empirical Study of the Effect of Thermal Loading on the Heating Efficiency of Variable-Speed Air Source Heat Pumps

Heating buildings with air source heat pumps (ASHPs) has the potential to save energy compared to utilizing conventional heat sources. Accurate understanding of the efficiency of ASHPs is important to maximize the energy savings. While it is well understood that, in general, ASHP efficiency decreases with decreasing outdoor temperature, it is not well understood how the ASHP efficiency changes with different levels of thermal loading, even though it is an important consideration for sizing and controlling ASHPs. The goal of this study was to create an empirical model of the ASHP efficiency as a function of two independent variables–outside temperature and level of thermal loading. Four ductless mini-split ASHPs were evaluated in a cold chamber where the temperature (representing the outdoor temperature) was varied over a wide range. For each temperature, the ASHP performance data were collected at several levels of thermal loading. The data for all four ASHPs were combined and approximated with an analytical function that can be used as a general model for the ASHP steady-state efficiency as a function of the outside temperature and level of thermal loading. To the knowledge of the authors, no such empirical model that is solely based on third-party test data has been published before. While limitations exist, the model can be used to help guide future selection and operation of ASHPs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

TRANSIENT THERMAL MODELING OF THE HIGH BURNUP DEMONSTRATION RESEARCH PROJECT CASK USING STAR-CCM+ AND COBRA-SFS

The Department of Energy in collaboration with the Electric Power Research Institute is in the process of conducting the High Burnup Demonstration Project. Where the objective is to characterize the performance of high-burnup fuel in long term storage. As part of this demonstration, a TN-32B dry storage cask was instrumented and loaded with spent nuclear fuel at North Anna Nuclear Generating Station in November 2017. The project cask provides a unique opportunity to gain information on spent fuel and cask performance from an in-service operational system. The cask was instrumented with thermocouples inside of the fuel assemblies, then loaded and dried using normal procedures. After the drying process a thermal soak period where the cask was left indoors was used to obtain steady temperatures for model comparison along with surface temperatures. This paper details thermal modeling validation work that was done to model both the steady state and transient cases. Two modeling tools were used to predict temperatures in the cask. The general purpose CFD and heat transfer code STAR-CCM+ was used with both a detailed pin-by-pin model was used along with a more efficient k-effective simplification. The other code is COBRA-SFS, a purpose-built detailed thermal modeling tool developed and maintained at PNNL. Results from all the modeling tools were compared blind to the test data. Each model utilized general design information and compared reasonably well to the blind steady state data using convection and surface temperature boundary conditions. Post-test adjustments were later made to better reflect the “as built” conditions of the cask. Based on lessons learned from the steady state analysis the vacuum drying process was modeled in both codes. Utilizing the measured loading conditions the transient models were able to compare very well with the measured data. Overall the project showed an ability to model spent fuel storage conditions very well and future work is planned to generalize the methodology used for vacuum drying.

Thermal Analysis, Spent Fuel, Dry Storage↗

Report on High-Fidelity Dynamic Modeling of a Coal-Fired Steam Power Plant

As a result of the growth of renewables including solar and wind energy with fluctuating production, fossil fuel power plants are being required to cycle between high and low power production. This cycling is both at a greater frequency and over a wider range than in the past. In many cases, power plants are not designed for this type of cycling operation but can nonetheless endure these challenging operation requirements under the right conditions. In this project, optimal solution for enhanced flexible operations are being investigated using model based estimation and control techniques. To support the development of model-based estimator and model-based controls at GE Global Research, GE Steam Power configured a dynamic model using a reference steam plant design including the boiler, turbine, and water/steam conditioning systems as well as the controls needed for plant cycling with stability and reliability. The dynamic model was built using the APROS® software from VTT, and then calibrated to multiple load conditions from full load (100%TMCR) to partial loads (75%TMCR, 50%TMCR and 25%TMCR) based on internally developed steady state heat balance models at the unit level. These internal heat balance models are based on first principles and extensive engineering experiences from GE Steam Power as an OEM and a services provider. This topical report presents the structure of the unit level dynamic model, the tuning process, and representative simulation results from typical load cycling simulations using the dynamic model.

01 COAL, LIGNITE, AND PEAT↗

Dynamic x-ray diffraction and nanosecond quantification of kinetics of formation of β -zirconium under shock compression

We report the atomic- and nanosecond-scale quantification of kinetics of a shock-driven phase transition in Zr metal. We uniquely make use of a multiple shock-and-release loading pathway to shock Zr into the β phase and to create a quasisteady pressure and temperature state shortly after. Coupling shock loading with in situ time-resolved synchrotron x-ray diffraction, we probe the structural transformation of Zr in the steady state. Our results provide a quantified expression of kinetics of formation of β-Zr phase under shock loading: transition incubation time, completion time, and crystallization rate.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Parametric estimation of Poisson's ratio for thin hinged-hinged plates

Cornu's method is an elegant calculation besieged by an impractical approach to obtain accurate estimates for Poisson's ratio. Conventionally, Cornu's method requires several components, and each component can adversely affect the accuracy of the measurement. Furthermore, Cornu's conventional method requires a long beam because beams with short length-to-width ratios cause the estimate of Poisson's ratio to diverge from the true value of Poisson's ratio. We believe that, with the right modifications, Cornu's method can become an attractive approach to obtaining precise estimates for Poisson's ratio from mode shapes. Here we use finite element simulations to show how to use Cornu's method to estimate Poisson's ratio from a mode shape. Our modified Cornu's method removes knife-edges and loading components for a hinged-hinged plate under steady-state excitation. Given the true value of Poisson's ratio, as a performance specification, we show that simple parametric expressions can fit estimates for Poisson's ratio for different length-to-width ratios of thin hinged-hinged plates. Additionally, we show that estimates for Poisson's ratio from higher modes align with the results from the first mode and explain our expectation for this outcome. Furthermore, our results challenge the idea that anticlastic, monoclastic, and synclastic deformation uniquely correspond to positive, zero, and negative estimates of Poisson's ratio, respectively. With the emergence of materials-by-design, we expect that this parametric technique will be able to assist in experimental qualification of thin beam and plate structures with respect to the desired value of Poisson's ratio.

42 ENGINEERING↗

Distribution System Blackstart and Restoration Using DERs and Dynamically Formed Microgrids

Extreme weather events have led to long-duration outages in the distribution system (DS), necessitating novel approaches to blackstart and restore the system. Existing blackstart solutions utilize blackstart units to establish multiple microgrids (MGs), sequentially energize non-blackstart units, and restore loads. However, these approaches often result in isolated MGs. In DERs-aided blackstart, the continuous operation of these MGs is limited by the finite energy capacity of commonly used blackstart units like battery energy storage (BES)-based gridforming inverters (GFMIs). To address this issue, this article proposes a holistic blackstart and restoration framework that incorporates synchronization between dynamic MGs and the entire DS with the transmission grid (TG). To support synchronization, we leveraged virtual synchronous generator-based control for GFMIs to estimate their frequency response to load pick-up events using only initial/final quasi-steady-state points. Subsequently, a synchronization switching condition is developed to model synchronizing switches, aligning them seamlessly with a linearized branch flow problem. Finally, we designed a bottomup blackstart and restoration framework that considers the switching structure of the DS, energizing/synchronizing switches, DERs with grid-following inverters, and BES-based GFMIs with frequency security constraints. In conclusion, the proposed framework is validated in IEEE-123-bus system, considering cases with two and four GFMIs under various TG recovery instants.

24 POWER TRANSMISSION AND DISTRIBUTION↗