EPCAPE-PT-LANL Measurements: Ground based counterflow virtual impactor

Coastal cities offer a unique environment for studying aerosol-cloud interactions and the effects of urban emissions on cloud properties. As part of the Eastern Pacific Cloud Aerosol Precipitation Experiment (EPCAPE), the Partitioning Thrust by Los Alamos National Laboratory (EPCAPE-PT-LANL) was conducted. Our campaign focused on measuring the optical and chemical properties of aerosols and their interactions within marine stratocumulus clouds in La Jolla, California. EPCAPE-PT-LANL enhances the primary goals of EPCAPE through innovative observations of vapor-phase transitions between aerosols and cloud droplets, the impact of black carbon on aerosol-cloud dynamics, and the effects of cloud processing on aerosol optical properties. Instrument: Ground based counter flow virtual impactor (Brechtel Inc) Data Notes: A factor of 6.7 needs to be applied to all cloud droplet residual concentration to correct the enhancement of the concentration because all the residual samples collected at 100 lpm were delivered into the 15 lpm of CVI sample flow. [https://amt.copernicus.org/articles/5/1259/2012/amt-5-1259-2012.html] Header: - Visibility[m]: The atmospheric visibility at the time of measurement, expressed in meters. - QualityControl_Flag[bool]: A boolean flag indicating whether the measurement passed quality control checks. - Temperature[C]: The ambient temperature at the time of the measurement, expressed in degrees Celsius. - CVI_Flag[bool]: A boolean flag indicating whether the Counterflow Virtual Impactor (CVI) was active (true) or inactive (false) during the measurement. - RelativeHumidity[%]: The relative humidity at the time of the measurement, expressed as a percentage

54 ENVIRONMENTAL SCIENCES↗

The Dynamics of Shock Dispersion and Interactions in Supersonic Freestreams with Counterflowing Jets

An active flow control concept using counterflowing jets to significantly modify the external flowfields and strongly weaken or disperse the shock-waves of supersonic and hypersonic vehicles to reduce the aerothermal loads and wave drag was investigated. Experiments were conducted in a trisonic blow-down wind-tunnel, complemented by pre-test computational fluid dynamics (CFD) analysis of a 2.6% scale model of Apollo capsule, with and without counterflowing jets, in Mach 3.48 and 4.0 freestreams, to assess the potential aerothermal and aerodynamic benefits of this concept. The model was instrumented with heat flux gauges, thermocouples and pressure taps, and employed five counterflowing jet nozzles (three sonic and other two supersonic with design Mach numbers of 2.44 and 2.94) and nozzle exit diameters ranging from 0.25 to 0.5 inch. Schlieren data show that at low jet flow rates of 0.05 and 0.1lb(sub m)/sec, the interactions result in a long penetration mode (LPM) jet, while the short penetration mode (SPM) jet is observed at flow rates greater than 0.1 lb(sub m)/sec., consistent with the pre-test CFD predictions. For the LPM, the jet appears to be nearly fully-expanded, resulting in a very unsteady and oscillatory flow structure in which the bow shock becomes highly dispersed such that it is no longer discernable. Higher speed camera Schlieren data reveal the shock to be dispersed into striations of compression waves, which suddenly coalesce to a weaker bow shock with a larger standoff distance as the flow rate reached a critical value. The pronounced shock dispersion could significantly impact the aerodynamic performance (L/D) and heat flux reduction of spacecraft in atmospheric entry and re-entry, and could also attenuate the entropy layer in hypersonic blunt body flows. For heat transfer, the results show significant reduction in heat flux, even giving negative heat flux for some of the SPM interactions, indicating that the flow wetting the model is cooling, instead of heating the model, which could significantly impact the requirements and design of thermal protection system. These findings strongly suggest that the application of counterflowing jets as active flow control could have strong impact on supersonic and hypersonic vehicle design and performance.

Daso, Endwell O.↗

Cleaning Up Large Groundwater Plumes to Drinking Water Standards: Dynamic Groundwater Recirculation at Reese Air Force Base - 17248

Overall cleanup of large plumes is perceived as being impossible because of issues of scale, contaminant mass accessibility, time to achieve cleanup, and cost. As a result, when a groundwater pump and treat (P and T) remedy is applied to larger plumes, the focus is usually hydraulic containment of contaminated groundwater to prevent further plume migration, rather than a total restoration objective. Recent experience with dynamic operation of groundwater extraction, treatment, and strategic reinjection (collectively referred to as dynamic groundwater recirculation [DGR]) demonstrates that large plume remediation can be accomplished cost effectively and in a timely manner. The insight from operating DGR remedies at multiple sites has demonstrated that contaminant mass residing in a complex aquifer setting is most appropriately described by a three-compartment model, which is a new revelation in contaminant hydrogeology redefining what is possible in restoration. A large-scale application of DGR was implemented under a firm fixed price contract at former Reese Air Force Base (AFB) located in Lubbock, Texas. The strategy was successful in restoration of a sole-source drinking water aquifer affected by a 3-mile long trichloroethene (TCE) plume. DGR allowed groundwater P and T rates to be decreased from over 3,400 liters per minute (lpm) to less than 1,500 lpm through initial optimization efforts. The DGR strategy focused extraction and reinjection on two key objectives: 1) maximizing contaminant mass recovery and 2) maintaining hydraulic control of the plume. Extraction and injection wells were dynamically operated and cycled to maintain a remediation pace that restored 0.8 to 1.2 hectares of the plume per week over a 6-year period. Plume cleanup to drinking water standards was achieved in 9 years of optimized operation. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Hydraulic and mixing evaluations for SRS miscible liquid solutions

The hydraulic results demonstrate that pump head pressure of 20 psi recirculates about 5.6 liters/min flowrate through the existing 0.131-inch orifice when a valve connected to NT-41 is closed. In case of the valve open to NT-41, the solution flowrates to Savannah River Site (SRS) tanks, NT-21 and NT-41, are found to be about 0.5 lpm and 5.2 lpm, respectively. The modeling calculations for the mixing operations of miscible fluids contained in the SRS HB-Line tank NT-21 were performed by taking a three-dimensional Computational Fluid Dynamics (CFD) approach. The CFD modeling results were benchmarked against the literature results and the previous SRNL test results to validate the model. Final performance calculations were performed for the nominal case by using the validated model to quantify the mixing time for the HB-Line tank. The results demonstrate that when a pump recirculates a solution volume of 5.7 liters every minute out of the 72-liter tank contents containing two acid solutions of 2.7 M and 0 M concentrations (i.e., water), a minimum mixing time of 1.5 hours is adequate for the tank contents to get the tank contents adequately mixed. In addition, the sensitivity results for the tank contents of 8 M existing solution and 1.5 M incoming species show that the mixing time takes about 2 hours to get the solutions mixed. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

lpm.a1

Datastream for the Laser Precipitation Monitor (LPM) instrument

54 ENVIRONMENTAL SCIENCES↗

Improved opacity expansion at NNLO for medium induced gluon radiation

When an energetic parton propagates in a hot and dense QCD medium it loses energy by elastic scatterings or by medium-induced gluon radiation. The gluon radiation spectrum is suppressed at high frequency due to the LPM effect and encompasses two regimes that are known analytically: at high frequencies &#x03C9;<!-- ω --> > &#x03C9;<!-- ω --> c = q &#x005E;<!-- ^ --> L 2 , where q &#x005E;<!-- ^ --> is the jet quenching transport coefficient and L the length of the medium, the spectrum is dominated by a single hard scattering, whereas the regime ω < ωc is dominated by multiple low momentum transfers. In this paper, we extend a recent approach (dubbed the Improved Opacity Expansion (IOE)), which allows an analytic (and systematic) treatment beyond the multiple soft scattering approximation, matching this result with the single hard emission spectrum. We calculate in particular the NNLO correction analytically and numerically and show that it is strongly suppressed compared to the NLO indicating a fast convergence of the IOE scheme and thus, we conclude that it is sufficient to truncate the series at NLO. We also propose a prescription to compare the GW and the HTL potentials and relate their parameters for future phenomenological works.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Holographic measurement and bulk teleportation

Holography has taught us that spacetime is emergent and its properties depend on the entanglement structure of the dual theory. In this paper, we describe how changes in the entanglement due to a local projective measurement (LPM) on a subregion A of the boundary theory modify the bulk dual spacetime. We find that LPMs destroy portions of the bulk geometry, yielding post-measurement bulk spacetimes dual to the complementary unmeasured region A c that are cut off by end-of-the-world branes. Using a bulk calculation in AdS 3 and tensor network models of holography (in particular, the HaPPY code and random tensor networks), we show that the portions of the bulk geometry that are preserved after the measurement depend on the size of A and the state we project onto. The post-measurement bulk dual to A c includes regions that were originally part of the entanglement wedge of A prior to measurement. This suggests that LPMs performed on a boundary subregion A teleport part of the bulk information originally encoded in A into the complementary region A c . In semiclassical holography an arbitrary amount of bulk information can be teleported in this way, while in tensor network models the teleported information is upper-bounded by the amount of entanglement shared between A and A c due to finite-N effects. When A is the union of two disjoint subregions, the measurement triggers an entangled/disentangled phase transition between the remaining two unmeasured subregions, corresponding to a connected/disconnected phase transition in the bulk description. Our results shed new light on the effects of measurement on the entanglement structure of holographic theories and give insight on how bulk information can be manipulated from the boundary theory. They could also represent a first step towards a holographic description of measurement-induced phase transitions.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Coastal-Fog Microphysics Using In-Situ Observations and GOES-R Retrievals

Here, the objective of this work is to evaluate GOES-R based fog conditions occurred during the C-FOG (Toward Improving Coastal Fog Prediction) field campaign. C-FOG is designed to advance understanding of fog formation, development, and dissipation over coastal environments to improve its predictability. The project took place along coastlines and open water environments of Eastern Canada (Nova Scotia, NS and the Island of Newfoundland, NL) during August-October of 2018 where environmental conditions play an important role for late season’s fog formation. During the C-FOG field campaign, instruments were located at the Ferryland Supersite, NL, with 2 main sites, and five satellite sites, as well as on the Research Vessel (R/V) Hugh R. Sharp. Key measurement instruments included a Gondola carrying a CDP (cloud droplet probe) and a BCP (backscatter cloud probe) was used for measuring droplet spectra from 1-75 µm on the R/V. A LPM (laser precipitation monitor) with 100 µm-1 cm size range and an OPC (optical particle counter) with 0.3-17 µm at 16 spectral channels provided information for fog and drizzle discrimination. Remote sensing platforms (e.g. profiling microwave radiometer, PMWR), Ceilometer, Lidar), meteorological towers, tethered balloons, and GOES-R products (e.g. fog coverage and droplet size and liquid water path) were used to evaluate fog over horizontal and vertical dimensions. Results suggest that effective radius, phase, liquid water path, and liquid water content values obtained from GOES-R and PMWR were comparable to ground based in-situ observations. It is concluded that integration of observations and nowcasting products may help improve short term local fog predictions.

54 ENVIRONMENTAL SCIENCES↗

The molten salt tritium transport experiment: A pumped fluoride salt loop for hydrogen isotope experimentation

Molten salt reactors (MSRs) and fusion reactors propose to use molten salts as coolants and breeder blanket materials, respectively. Tritium, however, poses safety concerns in both reactor types due to its ability to permeate through reactor materials and potential for environmental release. This manuscript addresses the tritium transport phenomena in molten salts and presents the design and analysis of the Molten Salt Tritium Transport Experiment (MSTTE). MSTTE is a forced-convection fluoride salt loop intended to measure hydrogen isotope permeation through structural materials in a flowing salt system. In the first phase, MSTTE will use FLiNaK salt and deuterium as surrogates for FLiBe and tritium, with future plans to utilize tritium and FLiBe. MSTTE couples a Copenhagen Atomics pumped salt loop with an external test section that introduces hydrogen isotopes into the loop and measures transport phenomena. The Hydrogen Injection System (HIS) controls hydrogen isotope introduction into the molten salt loop. Here, the permeation test section measures the permeation rate through stainless steel tubing in contact with flowing salt. Computational fluid dynamics (CFD) analysis ensures fully developed salt flow in the permeation test section. MSTTE is modeled with MELCOR-TMAP to predict the permeation rate as a function of experimental variables such as source term, salt flow rate, and salt temperature. Results indicate that the source term is the only parameter with a significant effect on the permeation rate. Pressure drop analysis suggests that the loop should operate below 200 LPM to maintain a pressure drop below 200 kPa. Additionally, finite-element analysis assesses thermal stress during loop operation to ensure the experiment's safe design. MSTTE will provide semi-integral data on tritium transport phenomena in molten salts and serve as a testbed for advancing molten salt technology.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Dissolved carbonic anhydrase for enhancing post-combustion carbon dioxide hydration in aqueous ammonia

Aqueous ammonia solvents that capture CO2 as ionic complexes of carbonates with ammonium have recently been advanced as alternatives to amine-based solvents due to their lower energy requirements for thermal regeneration. In ammonia based solvents, the hydration of CO2 to form bicarbonate may become a rate-limiting step as the CO2 loading increases and the resulting pH level of the solvent decreases. Variants of the enzyme carbonic anhydrase can accelerate the reversible hydration of CO2 to yield bicarbonate by more than 10(6)-fold. The possible benefit of bovine carbonic anhydrase (BCA) addition to solutions of aqueous ammonia to enhance CO2 hydration was investigated in semi-batch reactions within continuously stirred tank reactors or in a bubble column gas-liquid contactor. Adding 154 mg/liter of BCA to 2 M aqueous ammonia provided a 34.1% overall increase in the rate of CO2 hydration (as indicated by the production of [H+]) as the pH declined from 9.6 to 8.6 during sparging with a 15% CO2, 85% N-2 gas at a flow rate of 3 lpm. The benefits of adding BCA to enhance CO2 hydration were only discernable below similar to pH 9. The implications of the apparent pH limitations on the utility of BCA are discussed in the context of absorber unit operation design. Possible embodiments of carbonic anhydrase as either an immobilized catalyst or as a dissolved, recirculating catalyst in potential plant scale aqueous ammonia systems are considered as well. (C) 2010 Published by Elsevier Ltd.

59 BASIC BIOLOGICAL SCIENCES↗

Design of ECH launcher for KSTAR advanced Tokamak operation

For the advanced tokamak operation in Korea Superconducting Tokamak Advanced Research (KSTAR), up to 6 MW of electron cyclotron heating (ECH) is planned. The ECH launcher should be able to operate in steady state and serve as a central/off-axis heating and current drive, q-profile control, and control of the neoclassical tearing mode (NTM) and sawtooth. The water cooled launchers have been upgraded to include continuous operation with precise, high-speed real-time control of the beams by integration with the plasma control system (PCS) for supporting the experiments, in particular for suppressing NTM. Here, the launcher was successfully operated for 78 s with about 650 kW EC power, where the temperature of the coolant, with a flow rate of 9.6 lpm, is saturated and approximately 2 °C. The launcher control system had a maximum control cycle of 5 kHz and a motor latency of about 10 ms, and the poloidal scanning speed of the beam was 20 °/s. Additionally, for the higher localization of power deposition, the curvature and size of the mirrors in the launcher were optimized. This paper presents the ECH launcher design and its control system with the operation results.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Performance analysis of single-phase immersion cooling system of data center using FC-40 dielectric fluid

Immersion cooling technologies have become an emerging cooling method for data center cooling. The studies available in open literature dealt with immersion cooling performance of data servers using mineral oil, EC-100, and Opticool 872552, but the studies focusing on the performance of FC-40 dielectric fluid is not available. Therefore, this study aimed to develop a single-phase liquid immersion cooling system using FC-40 dielectric fluid for a 1U (44.45 mm height) data server. The present study experimentally investigated the influence of different design and operating parameters, including the inlet/outlet port configuration (T and Z configurations), the bypass effect, the flowrate (1–3 LPM), the heating load (200–600 W), the inlet fluid temperature (15–35 °C), the presence of suction fan with various arrangements, and different heat sink bases (solid base, vapor chamber and heat pipe base). The results showed that the T-configuration could provide a 12.6% and 0.5–2.8 °C reduction in thermal resistance and case temperature compared to the Z-configuration, respectively. Additionally, the heat sink with heat pipe and vapor chamber base offered a minimum case temperature of 56.7 °C and 55.2 °C against the 60 °C experienced in the heat sink with flat plate base, respectively.

42 ENGINEERING↗

Metal additively manufactured wavy fin cold-plate architecture for improved thermal-hydraulic performance

Rapid growth in artificial intelligence and data center workloads demands high-performance liquid cooling to manage increasing chip power. This study presents two metal-additive-manufactured cold plates with sinusoidal fins, constant-amplitude wavy fins and linearly variable-amplitude wavy fins and compares them against metal-additive-manufactured straight fins using experiments conducted at 1 kW heat dissipation as well as high-fidelity 3D conjugate computational fluid dynamic simulations. The cold plates were printed in AlSi10Mg material and underwent design using a Python-automated workflow prior to manufacture and testing. The experiments show that wavy fins reduce the normalized thermal resistance by 35 to 45 % at water flow rates from 1 to 4 LPM. At a fixed 20 kPa pressure drop, the variable-waviness design lowered peak surface temperature by 9 °C and thermal resistance by 51 %, while edge-channel maldistribution in the constant wavy fin design limited gains. A thermal resistance breakdown revealed that 55–63 % of the total thermal resistance in wavy designs comes from base heat conduction, 27–33 % from fin heat conduction, and 9–13 % from fin heat convection, indicating the need to address conduction bottlenecks. Parametric sweeps identify a 3 mm fin pitch as optimal, and that horizontal inlet/outlet manifolds further reduce pressure drop by 30–60 % and thermal resistance by 9–16 % relative to vertical inlet-outlet manifolds. The results yield comprehensive guidelines for fin geometry, manifold alignment, material selection and additive-manufacturing constraints to realize high-performance liquid-cooled cold plates for power-dense electronics.

3d printing↗

A cost-effective differential mobility analyzer (cDMA) for multiple DMA column applications

In aerosol research and applications, a differential mobility analyzer (DMA) is now considered the standard tool for sizing and classifying monodisperse particles in the sub-micrometer and nanometer size ranges. However, DMA application at the pilot or industrial production scale remains infeasible because of the low mass throughput. A simple way to scale up DMA operation is to use multiple DMA columns. The manufacture and maintenance costs of existing DMAs, however, limit such a scale-up. A cost-effective DMA column (named cDMA) has thus been developed in this work to address the above issue. To reduce its manufacturing cost, the prototype was constructed using parts requiring little machining. The cDMA column was also designed for easy maintenance and easy variation of the classification length for any application-specified size range. In this study, prototypes with two particle classification lengths, 1.75 and 4.50 cm, were constructed and their performance was experimentally evaluated at sheath-to-aerosol flowrate ratios of 5:1, 10:1, and 15:1 via the tandem DMA (TDMA) technique. It was concluded that both prototype cDMAs, operated at a sheath/aerosol flowrate ratio less than 15:1 and with a polydisperse aerosol flowrate of 1.0 lpm, achieved sizing resolution comparable to that offered by Nano-DMA. The longer cDMA had comparable transmission efficiency to that of Nano-DMA, and the shorter cDMA exceeded the performance of Nano-DMA. Hence, the cDMA with the shorter (1.75 cm) classification length is better suited for the characterization of macromolecular samples.

54 ENVIRONMENTAL SCIENCES↗

Warm Cleanup of Coal-Derived Syngas: Multicontaminant Removal Process Demonstration

Warm cleanup of coal- or biomass-derived syngas requires sorbent and catalytic beds to protect downstream processes and catalysts from fouling. Sulfur is particularly harmful because even parts-per-million amounts are sufficient to poison downstream synthesis catalysts. Zinc oxide (ZnO) is a conventional sorbent for sulfur removal; however, its operational performance using real gasifier-derived syngas and in an integrated warm cleanup process is not well reported. In this paper, we report the optimal temperature for bulk desulfurization to be 450oC, while removal of sulfur to parts-per-billion levels requires a lower temperature of approximately 350oC. Under these conditions, we found that sulfur in the form of both hydrogen sulfide and carbonyl sulfide could be absorbed equally well using ZnO. For long-term operation, sorbent regeneration is desirable to minimize process costs. Over the course of five sulfidation and regeneration cycles, a ZnO bed lost about a third of its initial sulfur capacity, however sorbent capacity stabilized. Here, we also demonstrate, at the bench-scale, a process and materials used for warm cleanup of coal-derived syngas using five operations: 1) Na2CO3 for HCl removal, 2) regenerable ZnO beds for bulk sulfur removal, 3) a second ZnO bed for trace sulfur removal, 4) a Ni-Cu/C sorbent for multi-contaminant inorganic removal, and 5) a Ir-Ni/MgAl2O4 catalyst employed for ammonia decomposition and tar and light hydrocarbon steam reforming. Syngas cleanup was demonstrated through successful long-term performance of a poison-sensitive, Cu-based, water-gas-shift catalyst placed downstream of the cleanup process train. The tar reformer is an important and necessary operation with this particular gasification system; its inclusion was the difference between deactivating the water-gas catalyst with carbon deposition and successful 100-hour testing using 1 LPM of coal-derived syngas.

Spies, Kurt A.↗

Electrocoagulation Combined with Ultrafiltration Membranes as Pretreatment for RO Desalination of Synthetic Cooling Tower Blowdown Water

Electrocoagulation (EC), an electrochemical water treatment process, is commonly used to remove particulate and colloidal matter from water. Here, in this study, we demonstrate that EC, when coupled with membrane filtration, is also capable of removing dissolved species, such as Ca + , Mg 2+ , and SiO x . The removal of such species is important for downstream membrane-based desalination treatment of the water that can suffer from reduced performance due to membrane scaling. Here, we describe how EC can be combined with a low-pressure membrane (LPM) system to offer efficient (and potentially universal) pretreatment for downstream membrane desalination. Synthetic water, simulating cooling tower blowdown (CTBD) with elevated concentrations of hardness and silicates (Ca: 418 ppm, Mg: 63 ppm, SiO 2 : 50 ppm) is treated using EC coupled to ultrafiltration (UF) to remove Mg up to 30 ± 1%, Ca up to 29 ± 1%, and silica up to 99 ± 1%. We evaluated the effectiveness of the EC-UF pretreatment system in reducing downstream RO scaling using thermodynamic modeling to predict the saturation index (SI) at the RO membrane/water interface. An SI value below zero (SI < 0) indicates under-saturated conditions (with respect to a particular mineral) where mineral scaling does not take place, which correlates with improved water recovery. Our findings suggest that the EC-UF pretreatment system was able to increase water recovery by up to 30%, compared to 0% recovery without pretreatment, under optimal conditions (feed solution pH of 7 and an EC charge loading of 1800 C/L). Finally, we conducted an economic analysis showing that implementing an EC-UF system for CTBD water could yield a cost benefit of up to $\$$14.13 per m 3 compared to direct brine disposal.

cooling tower blowdown↗

How to Solve Schroedinger Problems by Approximating the Potential Function

We give a survey over the efforts in the direction of solving the Schroedinger equation by using piecewise approximations of the potential function. Two types of approximating potentials have been considered in the literature, that is piecewise constant and piecewise linear functions. For polynomials of higher degree the approximating problem is not so easy to integrate analytically. This obstacle can be circumvented by using a perturbative approach to construct the solution of the approximating problem, leading to the so-called piecewise perturbation methods (PPM). We discuss the construction of a PPM in its most convenient form for applications and show that different PPM versions (CPM,LPM) are in fact equivalent.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Performance of pumped counterflow virtual impactors to study aerosol interactions with laboratory generated warm clouds

Pumped Counterflow Virtual Impactors (PCVI) are designed to separate aerosols based on aerodynamic diameter, which is particularly useful for isolating cloud droplets and ice crystals from smaller particles. However, the PCVI transmission efficiency (TE) values reported in the literature show considerable variability, and little information is available on the TEs for cloud liquid droplets. Here, we determined the optimal flow conditions for PCVI sampling for different activation ratios from the MTU Pi-cloud chamber, highlighting the conditions that maximize droplet residual sampling while minimizing interstitial transmission. Even for a lower limit cloud activation ratio = 1:10, an add flow of 1.5 LPM achieves a residual fraction greater than 0.80, with a droplet TE of ∼15% for typical Pi-Chamber droplets with diameters between 3.5 to 10 µm. This framework can be adapted for field cloud measurements based on the cloud conditions of interest. TE for cloud droplets under flow conditions at which ∼99% of the unactivated submicron particles were removed was substantially lower between 8 and 16% than for supermicron dry particles (∼30 to 40% for 3 µm polystyrene latex spheres). In addition, we conducted a comparison of the performances of three similar PCVI units to assess repeatability for dry aerosols and cloud droplets. All three PCVIs performed similarly in rejecting submicron particles smaller than the desired cutoff diameter. One of the units showed lower TEs due to a misalignment of the internal orifice. We discuss a procedure that improved alignment and performance.