Search NASA⌕ Search

SEARCH · Search NASA

Results for “LUT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

CloudSat-Constrained Cloud Ice Water Path and Cloud Top Height Retrievals from MHS 157 and 183.3 GHz Radiances

Ice water path (IWP) and cloud top height (ht) are two of the key variables in determining cloud radiative and thermodynamical properties in climate models. Large uncertainty remains among IWP measurements from satellite sensors, in large part due to the assumptions made for cloud microphysics in these retrievals. In this study, we develop a fast algorithm to retrieve IWP from the 157, 183.3+/-3 and 190.3 GHz radiances of the Microwave Humidity Sounder (MHS) such that the MHS cloud ice retrieval is consistent with CloudSat IWP measurements. This retrieval is obtained by constraining the empirical forward models between collocated and coincident measurements of CloudSat IWP and MHS cloud-induced radiance depression (Tcir) at these channels. The empirical forward model is represented by a lookup table (LUT) of Tcir-IWP relationships as a function of ht and the frequency channel.With ht simultaneously retrieved, the IWP is found to be more accurate. The useful range of the MHS IWP retrieval is between 0.5 and 10 kg/sq m, and agrees well with CloudSat in terms of the normalized probability density function (PDF). Compared to the empirical model, current operational radiative transfer models (RTMs) still have significant uncertainties in characterizing the observed Tcir-IWP relationships. Therefore, the empirical LUT method developed here remains an effective approach to retrieving ice cloud properties from the MHS-like microwave channels.

cloud top height↗

Minimizing the Standard Deviation of Spatially Averaged Surface Cross-Sectional Data from the Dual-Frequency Precipitation Radar

For an airborne or spaceborne radar, the precipitation-induced path attenuation can be estimated from the measurements of the normalized surface cross section, sigma 0, in the presence and absence of precipitation. In one implementation, the mean rain-free estimate and its variability are found from a lookup table (LUT) derived from previously measured data. For the dual-frequency precipitation radar aboard the global precipitation measurement satellite, the nominal table consists of the statistics of the rain-free 0 over a 0.5 deg x 0.5 deg latitude-longitude grid using a three-month set of input data. However, a problem with the LUT is an insufficient number of samples in many cells. An alternative table is constructed by a stepwise procedure that begins with the statistics over a 0.25 deg x 0.25 deg grid. If the number of samples at a cell is too few, the area is expanded, cell by cell, choosing at each step that cell that minimizes the variance of the data. The question arises, however, as to whether the selected region corresponds to the smallest variance. To address this question, a second type of variable-averaging grid is constructed using all possible spatial configurations and computing the variance of the data within each region. Comparisons of the standard deviations for the fixed and variable-averaged grids are given as a function of incidence angle and surface type using a three-month set of data. The advantage of variable spatial averaging is that the average standard deviation can be reduced relative to the fixed grid while satisfying the minimum sample requirement.

spaceborne meteorological radar↗

Assessment of Terra MODIS Thermal Emissive Band Calibration Using Cold Targets and Measurements in Lunar Roll Events

Terra MODIS has provided continuous global observations for science research and applications for more than 18 years. The MODIS Thermal emissive bands (TEB) radiometric calibration uses a quadratic function for instrument response. The calibration coefficients are updated using the response of an on-board blackbody (BB) in quarterly warm-up and cool-down (WUCD) events. As instrument degradation and electronic crosstalk of long-wave infrared (LWIR) bands 27 to 30 developed substantial issues, accurate calibration is crucial for a high-quality L1B product. The on-board BB WUCD temperature ranges from 270 K to 315 K and the derived nonlinear response has a relatively large uncertainty for the offset, especially for these LWIR bands, which affects the measurements of low brightness temperature (BT) scenes. In this study, the TEB radiometric calibration impact on the L1B product is assessed using selected cold targets and the measurements during regular lunar rolls. The cold targets include Antarctic Dome Concordia (Dome-C) and deep convective clouds (DCC) for the calibration assessment, focusing on bands 27 to 30. Dome-C area is covered with uniformly-distributed permanent snow, and the atmospheric effect is small and relatively constant. Usually the DCC is treated as an invariant earth target to evaluate the reflective solar band calibration. The DCC can also be treated as a stable target to assess the performance of TEB calibration. During a scheduled lunar observation event with a spacecraft roll maneuver to view the moon through the space view port, the instrument cavity provides a stable reference for calibration assessment. The long-term trending of BT measurements and the relative difference between scan mirror sides and detectors are used for the assessment of the calibration consistency and stability. The comparison of L1B products over the selected targets before and after the calibration coefficients update can be used to assess the impact of a calibration look-up table (LUT) update. This assessment is beneficial for future calibration algorithm and LUT update procedure improvements for enhancing the L1B product quality.

Chang, Tiejun↗

Can OMPS and VIIRS Be Used as a Single Virtual Sensor for Aerosol Retrieval?

Satellite earth observation of aerosols using a single sensor have been done for more than three decades. The retrieved global distribution of column integrated aerosol optical depth (AOD) has been refined with higher accuracy and finer resolutions. However, the other aerosol properties, such as aerosol absorption and aerosol height, haven not been mapped as extensively using passive sensors. The detectors sensitive to these properties (UV-based sensors such as Aura-OMI) lack the adequate visible channels to tease out the absorption, height and loading contributions. In addition, their spatial resolution is prone to frequent cloud contamination impacting aerosol loading retrievals using only these spectral ranges. However, the deployment of the VIIRS and OMPS-NM sensors on the same Suomi NPP platform provides a first opportunity to carry out retrievals of aerosol single scattering albedo (SSA) and AOD with little cloud contamination using an expanded spectral range from the UV to the near-IR wavelengths. After collocated VIIRS pixel within the large OMPS footprint during the high resolution OMPS observing mode, we compared the radiance from OMPS and VIIRS to ensure the calibration from individual sensors are comparable. Then a look up table (LUT) was created for a smoke case over central Africa. The LUT is generated using 10 channels from 0.357 to 2.1 micron with 44 combinations of aerosol models and 4 different aerosol heights. With CALIOP and AERONET observation nearby, the possibility of using OMPS and VIIRS radiance as a single virtual sensor to simultaneously and consistently retrieve AOD, SSA, and aerosol height is explored.

Shi, Yingxi↗

MODIS TEB Calibration Algorithm Improvements for Future L1B Collection

Terra and Aqua MODIS have provided continuous global observations for scientific applications for more than 20 and 18 years, respectively. The radiometric calibration of the MODIS thermal emissive bands (TEB) is based on a quadratic approximation of the instrument response. The calibration coefficients look-up tables (LUTs) are updated using the response of the MODIS on-board blackbody (BB)with the response background subtracted by space view. The quarterly on-board BB warm-up and cool-down activity temperature ranges from 270 K to 315 K, and the derived offset has a relatively large uncertainty. Electronic cross-talk, an artifact that affects both instrument calibration and Earth view (EV) radiance retrievals, is corrected based on lunar observations. Calibration assessments using EV observations (e.g. ocean, desert, Antarctic Dome Concordia, and deep convective clouds) provide useful information to evaluate the impact of the Terra safe mode (February 2016) and Aqua MODIS formatter reset (January 2018) events on both MODIS instruments. This study focuses on the TEB radiometric calibration algorithm improvements for future collections based on calibration assessments using EV measurements and analytical modeling. Measurement stability and consistency over specific Earth scenes with a wide temperature range, as well as their brightness temperature (BT) dependency, are used for bias estimations in the calibration coefficients. Calibration coefficients are derived and updated after adjusting the current fitting algorithm. Thereafter, using the test LUTs, their impact on the Level 1B (L1B) data for different EV scenes is analyzed.

MODIS↗

Dust Aerosol Retrieval Over the Oceans With the MODIS/VIIRS Dark Target Algorithm: 2. Nonspherical Dust Model

The Dark‐target (DT) aerosol algorithm retrieves spectral Aerosol Optical Depth (AOD) and other aerosol properties from Moderate‐resolution Imaging Spectrometer (MODIS) reflectance observations. Over the ocean, the DT algorithm is known to contain scattering‐angle‐dependent biases in its retrievals of AOD, Angstrom Exponent (AE), and Fine Mode Fraction (FMF) for dust aerosols. Following a two‐step strategy to improve the DT retrieval of dust over ocean, for which the first step is to identify dusty pixels (reported in “Part 1”), in this “Part 2,” we report on construction of a new dust model lookup table (LUT) and the strategy for applying it within the existing DT algorithm. In particular, we evaluate different characterizations of dust optical properties from a variety of frameworks and databases, and compare them with the current DT retrieval assumptions. Substituting the standard operational LUT with a spheroid dust model with identified dusty pixels shows significant improvement when compared with collocated AERONET‐identified dusty pixels. Specifically, the application of the new dust model to dusty pixels reduces their AOD bias from 0.06 to 0.02 while improving the fraction of retrievals within expected error from 64% to 82%. At the same time, the overall bias in AE is reduced from 0.13 to 0.06, and the scattering‐angle‐dependent AE bias is largely eliminated. In testing on two full months of data (April and July), the new retrieval will reduce the monthly mean AOD by up to 0.1 and 0.2 in the north Atlantic and Arabian seas, respectively. The average AE and FMF are also reduced in these dust heavy regions

dust aerosol retrieval↗

MODIS Reflective Solar Band Calibration Improvements using Pseudo-Invariant Desert Targets

To provide the best science data quality, an accurate characterization of the response versus scan angle (RVS) function is critical for the MODIS reflective solar bands (RSB) on-orbit calibration. In every MODIS operational scan, the Earth’s surface, referred to here as Earth view (EV), the space view (SV) port, and the onboard calibrators are viewed via a two-sided scan mirror. The RVS is defined as the sensor’s relative response as a function the angle of incidence (AOI) to the scan mirror. Many different approaches have been developed to derive the time-dependent RVS and its look-up table (LUT) applied to MODIS Level 1B (L1B) products since calibration Collection 4. For most MODIS RSB, the on-board calibrators can reasonably track the RVS change with time. In practice, their RVS is derived using data from on-board calibrators and the EV mirror side ratio (for mirror side 2). For Terra bands 1-4, 8-10 and Aqua bands 1-4, 8-9, an enhancement has been employed in Collections 6 and 6.1 (C6/C6.1) by using Earth scene response trending from pseudo-invariant desert sites in addition to the onboard calibrators. The current C6/C6/1 RVS algorithm is focused on fitting the EV data at each AOI over time and then deriving the relative change at different AOI. The EV response trending is currently fitted with multiple segments over time. Alternatively, the EV responses can be fit first as a function of AOI before fitting temporally in order to reduce the dependence on the stability of the desert site. These pre-treatment methods on the EV data provide improvement in the derived calibration coefficients. However, evidence of insufficient calibration is still observed in the MODIS L1B reflectance data, especially in the form of differences between the mirror sides. In this paper, we review the current methodologies that utilize the EV response trends from the pseudo-invariant Libyan desert targets to supplement the gain derived from the onboard calibrators. An improvement is then proposed and investigated such that a sliding window average (SWA) is used to pre-process the raw EV data. The SWA parameters are carefully selected using trade-off studies to accurately track the Earth scene response trending in multiple cases to overcome the reflectance differences between two mirror sides. Calibration results show improvements for both Aqua and Terra MODIS RSB L1B data products. This new adjustment has been included in the recently delivered Collection 7 LUT that will be evident in the L1B products expected to be released in late 2021.

MODIS↗

The Thermal Infrared Optical Depth of Mineral Dust Retrieved from Integrated CALIOP and IIR Observations

Recent studies reveal that a higher fraction of coarse mineral dust particles than that estimated by climate model simulations has been observed in the atmosphere, leading to a more significant positive (i.e., warming) longwave (LW) thermal infrared (TIR) direct radiative effect (DRE). However, the magnitude of this DRE remains highly uncertain because our understanding of the radiative properties, quantitatively represented by the optical depth of dust, especially information on the TIR, remains limited. This study presents a simple approach to retrieve the thermal infrared dust aerosol optical depth (DAODTIR) over oceans during nighttime using the observations from the Infrared Imaging Radiometer (IIR) and the Cloud-Aerosol Lidar with Orthogonal Polarization (CALIOP) onboard CALIPSO. For each cloud-free dust-laden profile identified by the IIR-CALIOP observation, a Lookup-Table (LUT) of the 10.6 μm IIR band brightness temperatures difference (dBT) under different DAODTIR with respect to their dust-free BTs is constructed based on the CALIOP retrieved dust vertical profile and pre-assumed dust scattering properties using a fast radiative transfer model. Then the DAODTIR is retrieved by projecting the IIR-observed dBT on the LUT. Sensitivity studies show that the DAODTIR retrieval at 10.6 μm is more susceptible to the dust particle size distribution (PSD) assumption than dust refractive indices. To estimate the uncertainty caused by PSD assumption, two DAODTIR retrieval products, one based on the dust PSD from the AERONET at Cape Verde and the other on an in situ measured PSD from the recent Fennec campaign, are provided. The retrieval uncertainty is mainly contributed by the BT difference between the observation and simulation using auxiliary atmospheric data. The climatology of the retrieval from 2013 to 2019 shows confident spatiotemporal variations of DAODTIR with the global-averaged value of 0.006 and 0.008 based on different pre-assumed dust PSDs. Climatological results agree reasonably well with two independent DAODTIR retrieval products based on the Infrared Atmospheric Sounding Interferometer (IASI) over the active dust transport regions, such as North and Tropical Atlantic (r = 0.904 and 0.819) and Indian Ocean (r = 0.832). The seasonal and interannual variation is also well-compared (r = 0.758) with AERONET coarse-mode AOD at 97 selected sites. The synergic CALIOP observation allows the retrieved DAODTIR to directly compare with the extrapolated DAODTIR from DAOD in visible (i.e., 532 nm), which helps evaluate the observational constraints on DAODTIR. This study offers a unique prospect of collocating active lidar and passive IR observations for retrieving dust DAODTIR.

aerosol↗

MODIS Thermal Emissive Bands Calibration Improvements for Collection 7

The MODIS thermal emissive bands (TEB) radiometric calibration uses a quadratic function for the instrument response, and the calibration coefficients look-up tables (LUTs) are updated using the response of an on-board blackbody (BB). After more than 21 and 19 years on-orbit, the TEB performances for Terra and Aqua MODIS have been generally stable. However, contamination from electronic crosstalk, a known issue since prelaunch, has affected the L1B image quality and measurement accuracy. In addition to the photovoltaic (PV) longwave infrared (LWIR) bands crosstalk correction included in Terra MODIS Collection 6.1 (C6.1), a crosstalk correction for select detectors in the Terra and Aqua mid-wave infrared (MWIR) and Aqua PV LWIR bands are applied in C7. The mission-long crosstalk coefficients for the selected detectors are derived and populated in the form of LUTs. The crosstalk correction is applied to both on-orbit calibration and the algorithm used to generate Earth-view L1B products. Among these detectors, the Aqua MODIS band 24 detector 1 crosstalk has the largest impact on image quality, with striping observed over cold scenes for both Terra and Aqua MODIS. The images of C7 L1B and C6.1 are compared to assess the impact of the correction. Additional assessments using Earthview measurements and inter-comparison also revealed the need for improvement of calibration stability and consistence for select bands. Additional improvements for long-term stability and mirror side consistence were developed using quasideep convective clouds (qDCC), Dome-C, ocean, desert, and inter-comparison with other instruments.

MODIS↗

Look-up Table Approach for Uncertainty Determination for Operational Vicarious Calibration of Earth Imaging Sensors

Understanding the uncertainty of a vicarious calibration is essential for any application to Earth imaging sensors. The Radiometric Calibration Network provides SI-traceable spectral top-of-atmosphere (TOA) reflectance from a network of ground sites and uses a look-up table (LUT) approach for uncertainty determination. The uncertainty LUT was derived using Monte Carlo techniques applied to the relevant solar geometry, surface, and atmospheric variables. While surface reflectance is typically the dominant uncertainty source, atmospheric contributions do play an important role, depending upon the exact scenario and conditions. This approach allows knowledge of TOA reflectance uncertainty to within 0.5%.

Brian N. Wenny↗

MODIS TEB Electronic Crosstalk Correction Update and Impact on L1B Product Uncertainty

The MODIS instruments onboard the Terra and Aqua satellites have been in operation for over22 and 20 years, respectively. The instruments’ calibration accuracy has been maintained, even with instrument degradation. Electronic crosstalk in the thermal emissive bands (TEB) is a known issue with an increasing impact on the calibration and product. The Terra MODIS photovoltaic (PV) longwave infrared (LWIR) bands crosstalk corrections have been applied in Collection 6.1 (C6.1). However, the electronic crosstalk contamination for some detectors in the mid-wave infrared (MWIR) bands and the Aqua PVLWIR bands affect the Level-1B (L1B) product’s measurement accuracy and image quality. In Collection 7 (C7), crosstalk corrections for select detectors in the Terra and Aqua MWIR and Aqua PV LWIR bands are applied. The entire mission crosstalk coefficients for the select detectors and bands are derived from scheduled lunar observations and populated in the form of look-up tables (LUTs). The Aqua PV-LWIR bands exhibit similar downward crosstalk trends as the Terra PV-LWIR bands, especially in recent years. The crosstalk coefficients and their trends provide a guideline for the correction application. Earth measurement analyses before and after the correction provide contamination and correction assessments. It has been shown that the product quality is enhanced with the crosstalk correction applied in C7. For C7, the crosstalk coefficient uncertainty is derived from the fit residuals between the measured values and a linear fit over a three-year sliding window. The uncertainty propagation is modeled and applied in the total uncertainty calculation intheL1B product. The TEB electronic crosstalk LUTs have been processed over the entire Terra and Aqua MODIS missions. This paper presents the C7 crosstalk correction, as well as its assessment and uncertainty propagation algorithm to the TEB uncertainty.

Tiejun Chang↗

Modis TEB Electronic Crosstalk Correction Update and Impact on L1B Product Uncertainty

The MODIS instruments on board the Terra and Aqua satellites have been in operation for over 22 and 20 years, respectively. The instruments’ calibration accuracy has been maintained, even with instrument degradation. Electronic crosstalk in the thermal emissive bands (TEB) is a known issue with an increasing impact on the calibration and product. The Terra MODIS photovoltaic (PV) longwave infrared (LWIR) bands crosstalk corrections have been applied in Collection 6.1 (C6.1). However, the electronic crosstalk contamination for some detectors in the mid-wave infrared(MWIR) bands and the Aqua PVLWIR bands affect the Level-1B(L1B) product’s measurement accuracy and image quality. In Collection 7 (C7), crosstalk corrections for select detectors in the Terra and Aqua MWIR and Aqua PV LWIR bands are applied. The entire mission crosstalk coefficients for the select detectors and bands are derived from scheduled lunar observations and populated in the form of look-up tables (LUTs). The Aqua PV-LWIR bands exhibit similar downward crosstalk trends as the Terra PV-LWIR bands, especially in recent years. The crosstalk coefficients and their trends provide a guideline for the correction application. Earth measurement analyses before and after the correction provide contamination and correction assessments. It has been shown that the product quality is enhanced with the crosstalk correction applied in C7. For C7, the crosstalk coefficient uncertainty is derived from the fit residuals between the measured values and a linear fit over a three-year sliding window. The uncertainty propagation is modeled and applied in the total uncertainty calculation intheL1B product. The TEB electronic cross talk LUT shave been processed over the entire Terra and Aqua MODIS missions. This paper presents the C7 crosstalk correction, as well as its assessment and uncertainty propagation algorithm to the TEB uncertainty.

Tiejun Chang↗

Digital intermediate frequency QAM modulator using parallel processing

The digital Intermediate Frequency (IF) modulator applies to various modulation types and offers a simple and low cost method to implement a high-speed digital IF modulator using field programmable gate arrays (FPGAs). The architecture eliminates multipliers and sequential processing by storing the pre-computed modulated cosine and sine carriers in ROM look-up-tables (LUTs). The high-speed input data stream is parallel processed using the corresponding LUTs, which reduces the main processing speed, allowing the use of low cost FPGAs.

97 MATHEMATICS AND COMPUTING↗

Reliability concerns with logical constants in Xilinx FPGA designs

In Xilinx Field Programmable Gate Arrays logical constants, which ground unused inputs and provide constants for designs, are implemented in SEU-susceptible logic. In the past, these logical constants have been shown to cause the user circuit to output bad data and were not resetable through off-line rcconfiguration. In the more recent devices, logical constants are less problematic, though mitigation should still be considered for high reliability applications. In conclusion, we have presented a number of reliability concerns with logical constants in the Xilinx Virtex family. There are two main categories of logical constants: implicit and explicit logical constants. In all of the Virtex devices, the implicit logical constants are implemented using half latches, which in the most recent devices are several orders of magnitudes smaller than configuration bit cells. Explicit logical constants are implemented exclusively using constant LUTs in the Virtex-I and Virtex-II, and use a combination of constant LUTs and architectural posts to the ground plane in the Virtex-4. We have also presented mitigation methods and options for these devices. While SEUs in implicit and some types of explicit logical constants can cause data corrupt, the chance of failure from these components is now much smaller than it was in the Virtex-I device. Therefore, for many cases, mitigation might not be necessary, except under extremely high reliability situations.

97 MATHEMATICS AND COMPUTING↗

Unilateral Versus Bilateral Prostatic Arterial Embolization for Lower Urinary Tract Symptoms in Patients with Prostate Enlargement

This study was designed to compare baseline data and clinical outcome between patients with prostate enlargement/benign prostatic hyperplasia (PE/BPH) who underwent unilateral and bilateral prostatic arterial embolization (PAE) for the relief of lower urinary tract symptoms (LUTS). This single-center, ambispective cohort study compared 122 consecutive patients (mean age 66.7 years) with unilateral versus bilateral PAE from March 2009 to December 2011. Selective PAE was performed with 100- and 200-{mu}m nonspherical polyvinyl alcohol (PVA) particles by a unilateral femoral approach. Bilateral PAE was performed in 103 (84.4 %) patients (group A). The remaining 19 (15.6 %) patients underwent unilateral PAE (group B). Mean follow-up time was 6.7 months in group A and 7.3 months in group B. Mean prostate volume, PSA, International prostate symptom score/quality of life (IPSS/QoL) and post-void residual volume (PVR) reduction, and peak flow rate (Qmax) improvement were 19.4 mL, 1.68 ng/mL, 11.8/2.0 points, 32.9 mL, and 3.9 mL/s in group A and 11.5 mL, 1.98 ng/mL, 8.9/1.4 points, 53.8 mL, and 4.58 mL/s in group B. Poor clinical outcome was observed in 24.3 % of patients from group A and 47.4 % from group B (p = 0.04). PAE is a safe and effective technique that can induce 48 % improvement in the IPSS score and a prostate volume reduction of 19 %, with good clinical outcome in up to 75 % of treated patients. Bilateral PAE seems to lead to better clinical results; however, up to 50 % of patients after unilateral PAE may have a good clinical outcome.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Intra-vesical Prostatic Protrusion (IPP) Can Be Reduced by Prostatic Artery Embolization

BackgroundProstate artery embolization (PAE) is a new approach to improve lower urinary tract symptoms (LUTS) related to benign prostatic hyperplasia. PAE results in global reduction of prostate volume (PV). There are no data available on the efficacy of PAE in reducing intra-vesical prostatic protrusion (IPP), an anatomic feature that is clinically related with bladder outlet obstruction and LUTS.ObjectiveTo assess the results of PAE in patients with significant IPP due to median lobe hyperplasia and to compare the IPSS decrease and IPP change.Material and MethodsProspective analysis of 18 consecutive patients with significant IPP (>5 mm) related to median lobe hyperplasia undergoing PAE using 30–500-μm-calibrated trisacryl microspheres. We measured IPP on sagittal T2-weighted images before and 3 months after PAE. IPSS and clinical results were also evaluated at 3 months.ResultsPAE resulted in significant IPP reduction (1.57 cm ± 0.55 before PAE and 1.30 cm ± 0.46 after PAE, p = 0.0005) (Fig. 1) with no complication. IPSS, quality of life (QoL), total prostate-specific antigen (PSA) level, and PV showed significant reduction after PAE, and maximum urinary flow rate (Q{sub max}) showed significant increase after PAE. No significant change of International Index of Erectile Function (IIEF) for clinical evaluation after PAE. A significant correlation was found between the IPP change and the IPSS change (r = 0.636, p = 0.0045).ConclusionPatients had significant IPP reduction as well as significant symptomatic improvement after PAE, and these improvements were positively correlated.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Clinical Results After Prostatic Artery Embolization Using the PErFecTED Technique: A Single-Center Study

BackgroundProstatic artery embolization (PAE) has been performed for a few years, but there is no report on PAE using the PErFecTED technique outside from the team that initiated this approach.ObjectiveThis single-center retrospective open label study reports our experience and clinical results on patients suffering from symptomatic BPH, who underwent PAE aiming at using the PErFecTED technique.Materials and MethodsWe treated 32 consecutive patients, mean age 65 (52–84 years old) between December 2013 and January 2015. Patients were referred for PAE after failure of medical treatment and refusal or contra-indication to surgery. They were treated using the PErFecTED technique, when feasible, with 300–500 µm calibrated microspheres (two-night hospital stay or outpatient procedure). Follow-up was performed at 3, 6, and 12 months.ResultsWe had a 100 % immediate technical success of embolization (68 % of feasibility of the PErFecTED technique) with no immediate complications. After a mean follow-up of 7.7 months, we observed a 78 % rate of clinical success. Mean IPSS decreased from 15.3 to 4.2 (p = .03), mean QoL from 5.4 to 2 (p = .03), mean Qmax increased from 9.2 to 19.2 (p = .25), mean prostatic volume decreased from 91 to 62 (p = .009) mL. There was no retrograde ejaculation and no major complication.ConclusionPAE using the PErFecTED technique is a safe and efficient technique to treat bothersome LUTS related to BPH. It is of interest to note that the PErFecTED technique cannot be performed in some cases for anatomical reasons.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Safety and Efficacy of Occlusion of Large Extra-Prostatic Anastomoses During Prostatic Artery Embolization for Symptomatic BPH

IntroductionDuring PAE, preembolization angiography of the prostatic artery can show large extra-prostatic shunts, at high risk, if embolized, of rectal or penile necrosis. We report our experience with 11 consecutive patients who underwent protective embolization of large extra-prostatic shunts before successful PAE.Materials and MethodsWe treated 11 consecutive male patients (mean age 67 years), part of a series of 55 consecutive male patients referred for PAE to treat LUTS due to BPH, between December 2013 and January 2015. The procedure involved the exclusion of an extra-prostatic shunt originating from the PA, prior to complete bilateral PAE. We compared the safety and efficacy of the 11 shunt exclusions followed by embolization of the PA to the other 44 basic PAE. Clinical success was defined as a decrease of 25 % or eight points of IPSS, QoL <3 or a one-point decrease, and a Qmax improvement of 25 % or 2.5 mL/s.ResultsWe had a 100 % rate of occlusion of the anastomosis. Bilateral embolization of the PA was performed in all patients with no additional time of procedure (p = 0.18), but a significant increase of dose area product (p = 0.03). Distal (PErFecTED) embolization was possible in 64 %. There was no worsening of erectile dysfunction, no rectal or penile necrosis, no immediate or late other clinical complications. Clinical success was 91 % (mean follow-up: 3.5 months), compared to 78 % for the entire PAE group.ConclusionPAE using the protection technique in case of large extra-prostatic shunts is as safe and effective as basic procedures and does not induce any additional time of procedure.

62 RADIOLOGY AND NUCLEAR MEDICINE↗