At least 73 records · Page 4

Replacement of Hydrochlorofluorocarbon (HCFC) -225 Solvent for Cleaning and Verification Sampling of NASA Propulsion Oxygen Systems Hardware, Ground Support Equipment, and Associated Test Systems

Since the 1990's, when the Class I Ozone Depleting Substance (ODS) chlorofluorocarbon-113 (CFC-113) was banned, NASA's rocket propulsion test facilities at Marshall Space Flight Center (MSFC) and Stennis Space Center (SSC) have relied upon hydrochlorofluorocarbon-225 (HCFC-225) to safely clean and verify the cleanliness of large scale propulsion oxygen systems. Effective January 1, 2015, the production, import, export, and new use of HCFC-225, a Class II ODS, was prohibited by the Clean Air Act. In 2012 through 2014, leveraging resources from both the NASA Rocket Propulsion Test Program and the Defense Logistics Agency - Aviation Hazardous Minimization and Green Products Branch, test labs at MSFC, SSC, and Johnson Space Center's White Sands Test Facility (WSTF) collaborated to seek out, test, and qualify a replacement for HCFC-225 that is both an effective cleaner and safe for use with oxygen systems. Candidate solvents were selected and a test plan was developed following the guidelines of ASTM G127, Standard Guide for the Selection of Cleaning Agents for Oxygen Systems. Solvents were evaluated for materials compatibility, oxygen compatibility, cleaning effectiveness, and suitability for use in cleanliness verification and field cleaning operations. Two solvents were determined to be acceptable for cleaning oxygen systems and one was chosen for implementation at NASA's rocket propulsion test facilities. The test program and results are summarized. This project also demonstrated the benefits of cross-agency collaboration in a time of limited resources.

Mitchell, Mark A.↗

Replacement of HCFC-225 Solvent for Cleaning NASA Propulsion Oxygen Systems

Since the 1990's, when the Class I Ozone Depleting Substance (ODS) chlorofluorocarbon‐113 (CFC‐113) was banned, NASA's rocket propulsion test facilities at Marshall Space Flight Center (MSFC) and Stennis Space Center (SSC) have relied upon hydrochlorofluorocarbon‐225 (HCFC‐225) to safely clean and verify the cleanliness of large scale propulsion oxygen systems. Effective January 1, 2015, the production, import, export, and new use of HCFC‐225, a Class II ODS, was prohibited by the Clean Air Act. In 2012 through 2014, leveraging resources from both the NASA Rocket Propulsion Test Program and the Defense Logistics Agency ‐ Aviation Hazardous Minimization and Green Products Branch, test labs at MSFC, SSC, and Johnson Space Center's White Sands Test Facility (WSTF) collaborated to seek out, test, and qualify a replacement for HCFC‐225 that is both an effective cleaner and safe for use with oxygen systems. Candidate solvents were selected and a test plan was developed following the guidelines of ASTM G127, Standard Guide for the Selection of Cleaning Agents for Oxygen Systems. Solvents were evaluated for materials compatibility, oxygen compatibility, cleaning effectiveness, and suitability for use in cleanliness verification and field cleaning operations. Two solvents were determined to be acceptable for cleaning oxygen systems and one was chosen for implementation at NASA's rocket propulsion test facilities. The test program and results are summarized. This project also demonstrated the benefits of cross‐agency collaboration in a time of limited resources.

Mitchell, Mark A.↗

Results of the Test Program for Replacement of AK-225G Solvent for Cleaning NASA Propulsion Oxygen Systems

Since the 1990's, when the Class I Ozone Depleting Substance chlorofluorocarbon-113 was banned, NASA's propulsion test facilities at Marshall Space Flight Center and Stennis Space Center have relied upon the solvent Asahiklin AK-225 (hydrochlorofluorocarbon-225ca/cb or HCFC-225ca/cb) and, more recently AK-225G (the single isomer form, HCFC-225cb) to safely clean and verify the cleanliness of large scale propulsion oxygen systems. Effective January 1, 2015, the production, import, export, and new use of Class II Ozone Depleting Substances, including AK-225G, was prohibited in the United States by the Clean Air Act. In 2012 through 2014, NASA test labs at MSFC, SSC, and Johnson Space Center's White Sands Test Facility collaborated to seek out, test, and qualify a solvent replacement for AK-225G that is both an effective cleaner and safe for use with oxygen systems. This paper summarizes the tests performed, results, and lessons learned.

Lowrey, Nikki M.↗

Results of the Test Program for Replacement of AK-225G Solvent for Cleaning NASA Propulsion Oxygen Systems

Since the 1990's, when the Class I Ozone Depleting Substance (ODS) chlorofluorocarbon-113 (CFC-113) was banned, NASA's propulsion test facilities at Marshall Space Flight Center (MSFC) and Stennis Space Center (SSC) have relied upon the solvent AsahiKlin AK-225 (hydrochlorofluorocarbon-225ca/cb or HCFC-225ca/cb) and, more recently AK-225G (the single isomer form, HCFC-225cb) to safely clean and verify the cleanliness of large scale propulsion oxygen systems. Effective January 1, 2015, the production, import, export, and new use of Class II Ozone Depleting Substances, including AK-225G, was prohibited in the United States by the Clean Air Act. In 2012 through 2014, NASA test labs at MSFC, SSC, and Johnson Space Center's White Sands Test Facility (WSTF) collaborated to seek out, test, and qualify a solvent replacement for AK-225G that is both an effective cleaner and safe for use with oxygen systems. This paper summarizes the tests performed, results, and lessons learned.

Lowrey, Nikki M.↗

Results of All Polyimide, Etched Foil Heater Qualification and Failure Limit Testing

Standard FEP (Fluorinated Ethylene Propylene resin) polyimide (SFP) or Kapton film heaters—which have a long history of space flight—are output-power limited by the melting point of Teflon which is used as an adhesive and insulator between the encasing layers of Kapton. The limit is expressed as a power density or through maximum operating temperature limits. All-polyimide (AP) heaters (also known as adhesive-less heaters) do not contain FEP Teflon between the layers of Kapton so the heaters are unconstrained by the melting point of Teflon. Thus, AP heaters have a higher maximum power density and operating temperature. AP heaters have not been qualified or flown on JPL missions but could be useful in applications that require a higher power density (Watt density) than the SFP heaters can support. The purpose of this paper is to document the qualification and property testing of the AP heaters for flight purposes. JPL (Jet Propulsion Lab.) tested several varieties of all-polyimide heaters to determine their functional equivalence to the standard heater which has substantial flight heritage and to determine their maximum limits. Tests included standard in-air burn-in tests, maximum power testing, lead pull strength, process qualification verification (PQV), long duration thermal cycling, and electro-magnetic compatibility shielding properties for copper-cladded shielded heaters. The results show that the all-polyimide heater appears to be functionally equivalent to the standard heater and has a higher Watt density and maximum operating temperature limit. The tests, test articles, failure analysis of the test articles, and results are described herein. These test results indicate that the all-polyimide heater is ready for flight applications.

Cucullu, Gordon C., III↗

Reliability Evaluation of Bifacial and Monofacial Glass/Glass Modules with EVA and non-EVA Encapsulants

The market share for bifacial modules is projected to be doubled from 30% to 60% in the next ten years. For the monofacial crystalline silicon glass/backsheet (G/B) modules, extensive reliability data has been available for over 40 years. However, practically little/no long-term field or accelerated reliability test data is available for the new generation glass/glass (G/G) bifacial modules and glass/transparent (G/T) bifacial modules. Therefore, the primary motivation of this project was to identify the reliability strengths and weaknesses of new generation G/G modules compared to G/B modules. In this 3-year project, the goal was to objectively recommend the best construction materials for the new generation G/G (bifacial) modules through a systematic experimental approach with appropriate tasks including: Evaluation of field retrieved old-generation G/G modules; Inspection of new-generation G/G modules installed in the plants; Evaluation of new-generation G/G, G/B and G/T modules using EAST (Extended Accelerated Stress Testing), CAST (Combined Accelerated Stress Testing) and FAST (Field Accelerated Stress Testing); and, dynamic literature search and review. Major accomplishments and outcomes of this project are: Accomplishments: Evaluated more than 60 field retrieved modules and constructed and characterized more than 135 mini-modules with three substrate types (G, B, and T), two encapsulant types (EVA and POE), and two cell types (monofacial and bifacial) as well as evaluated more than 30 commercial G/G and G/B modules; Subjected all the modules to multitude characterization tests and various indoor and outdoor accelerated stress tests including FAST (Field Accelerated Stress Testing), EAST (Extended Accelerated Stress Testing), and CAST (Combined Accelerated Stress Testing) to identify and correlate the failure modes in both field and lab tests. Outcomes: Based on the accelerated test results and handling/mounting experience obtained in this project, the recommended best construction for the glass/glass modules is: “Framed GG modules with cut-cells and POE encapsulant (UVpass front; UVpass back).” However, from a statistical and manufacturing point of view (along with stakeholders surveys), the following cautionary notes are added to the above-mentioned recommendation: (i) Cut cells could introduce a higher level of manufacturing issues, including a higher number of cell interconnects; (ii) POE encapsulant is more expensive than EVA and could present a delamination risk and lower throughput during manufacturing due to lower adhesion strength. Other encapsulants, such as coextruded EPE (EVA/POE/EVA), are also recommended to be investigated. The potential public benefit of the proposed project is to present the strengths and weaknesses of glass/glass modules, so an informed procurement decision can be made.

14 SOLAR ENERGY↗

Degradation and ESR Failures in MnO2 Chip Tantalum Capacitors

Equivalent series resistance (ESR) of chip tantalum capacitors determines the rate of energy delivery and power dissipation thus affecting temperature and reliability of the parts. Employment of advanced capacitors with reduced ESR decreases power losses and improves efficiency in power systems. Stability of ESR is essential for correct operations of power units and might cause malfunctioning and failures when ESR becomes too high or too low. Several cases with ESR values in CWR29 capacitors exceeding the specified limit that were observed recently raised concerns regarding environmental factors affecting ESR and the adequacy of the existing screening and qualification testing. In this work, results of stress testing of various types of military and commercial capacitors obtained over years by GSFC test lab and NEPP projects that involved ESR measurements are described. Environmental stress tests include testing in humidity and vacuum chambers, temperature cycling, long-term storage at high temperatures, and various soldering simulation tests. Note that in many cases parts failed due to excessive leakage currents or reduced breakdown voltages. However, only ESR-related degradation and failures are discussed. Mechanisms of moisture effect are discussed and recommendations to improve screening and qualification system are suggested.

Equivalent Series Resistance (ESR)↗

Angle of Incidence Characterization of Six Laminated Solar Cells for 2020 DTU Fotonik Inter-Laboratory Comparison Study

Photovoltaic energy prediction models include functions or modifiers to account for sun angle reflection losses. These functions may be known interchangeably as Angle of Incidence (AOI) or Incident Angle Modifier (IAM). While standards exist, there is no universally accepted single best practice for developing these functions. They can be generated through characterization of representative modules or single cells, in natural sunlight or indoors using simulated light sources. Repeatability of measurements and the viability of cross-laboratory comparisons are critical to confidence in validation of both methods. To investigate the differences between methods and labs, The Technical University of Denmark (DTU) initiated an international round-robin test comparison between several key test labs with AOI measurement capability. A total of six minimodules were provided in three different cell/interconnect/backsheet combinations. Sandia characterized these minimodules using methods developed over two decades specifically for the outdoor characterization of full-size photovoltaic modules. This report documents the characterization results, summarizes key observations and tabulates the processed data for comparison to results provided by other characterization labs.

14 SOLAR ENERGY↗

Integrated Application of Active Controls (IAAC) technology to an advanced subsonic transport project: Test act system validation

The primary objective of the Test Active Control Technology (ACT) System laboratory tests was to verify and validate the system concept, hardware, and software. The initial lab tests were open loop hardware tests of the Test ACT System as designed and built. During the course of the testing, minor problems were uncovered and corrected. Major software tests were run. The initial software testing was also open loop. These tests examined pitch control laws, wing load alleviation, signal selection/fault detection (SSFD), and output management. The Test ACT System was modified to interface with the direct drive valve (DDV) modules. The initial testing identified problem areas with DDV nonlinearities, valve friction induced limit cycling, DDV control loop instability, and channel command mismatch. The other DDV issue investigated was the ability to detect and isolate failures. Some simple schemes for failure detection were tested but were not completely satisfactory. The Test ACT System architecture continues to appear promising for ACT/FBW applications in systems that must be immune to worst case generic digital faults, and be able to tolerate two sequential nongeneric faults with no reduction in performance. The challenge in such an implementation would be to keep the analog element sufficiently simple to achieve the necessary reliability.

Source record↗

Cryogenics Research and Engineering Experience

Energy efficient storage, transfer and use of cryogens and cryogenic propellants on Earth and in space have a direct impact on NASA, government and commercial programs. Research and development on thermal insulation, propellant servicing, cryogenic components, material properties and sensing technologies provides industry, government and research institutions with the cross-cutting technologies to manage low-temperature applications. Under the direction of the Cryogenic Testing Lab at Kennedy Space Center, the work experience acquired allowed me to perform research, testing, design and analysis of current and future cryogenic technologies to be applied in several projects.

Toro Medina, Jaime A.↗

Enhanced Low Dose Rate Effects in Bipolar Circuits: A New Hardness Assurance Problem for NASA

Many bipolar integrated circuits are much more susceptible to ionizing radiation at low dose rates than they are at high dose rates typically used for radiation parts testing. Since the low dose rate is equivalent to that seen in space, the standard lab test no longer can be considered conservative and has caused the Air Force to issue an alert. Although a reliable radiation hardness assurance test has not yet been designed, possible mechanisms for low dose rate enhancement and hardness assurance tests are discussed.

bipolar integrated circuits↗

Integrated Test and Evaluation (ITE) Flight Test Series 4

The integrated Flight Test 4 (FT4) will gather data for the UAS researchers Sense and Avoid systems (referred to as Detect and Avoid in the RTCA SC 228 ToR) algorithms and pilot displays for candidate UAS systems in a relevant environment. The technical goals of FT4 are to: 1) perform end-to-end traffic encounter test of pilot guidance generated by DAA algorithms; 2) collect data to inform the initial Minimum Operational Performance Standards (MOPS) for Detect and Avoid systems. FT4 objectives and test infrastructure builds from previous UAS project simulations and flight tests. NASA Ames (ARC), NASA Armstrong (AFRC), and NASA Langley (LaRC) Research Centers will share responsibility for conducting the tests, each providing a test lab and critical functionality. UAS-NAS project support and participation on the 2014 flight test of ACAS Xu and DAA Self Separation (SS) significantly contributed to building up infrastructure and procedures for FT3 as well. The DAA Scripted flight test (FT4) will be conducted out of NASA Armstrong over an eight-week period beginning in April 2016.

ITE↗

NASA JSC’s Simulant Development Lab Capabilities and Artemis Testing

The Simulant Development Lab (SDL) is a multifunctional collaborative workspace that supports the development, curation, analysis, testing, and distribution of planetary regolith simulants – including lunar, Martian, asteroidal, and other granular materials. The lab provides a multidisciplinary setting for scientific characterization of simulant physical properties and for engineering evaluations conducted with simulant test beds. To enable this work, the SDL curates and maintains a stock of more than 35 metric tons of simulant material. To evaluate these materials and support testing goals, the lab is equipped with a comprehensive suite of processing tools and analytical instruments. These capabilities enable the SDL’s mission at NASA’s Johnson Space Center to distribute, develop, process, characterize, and test regolith simulants for mission relevant applications. Through controlled and repeatable testing environments that replicate the physical and compositional properties of lunar regolith, the SDL supports Artemis hardware maturation, providing safe, Earth‑based analogs for evaluating systems that must withstand regolith dust interactions, physical wear and abrasion, and operational loads. The facility’s extensive simulant inventory and integrated geological and engineering test infrastructure accelerate technology readiness for Artemis and future exploration campaigns (e.g., future crewed or robotic missions to Mars).

Simulant Development Lab↗

Evaluation of Additively Manufactured Monolithic SiC and SiC Ceramic Matrix Composites for Concentrating Solar Receiver Applications

Supported by an award from the Solar Technology Office, US Department of Energy, GE Aerospace Research in collaboration with Heliogen Holdings Inc, is engaged in the development of ultra-High Operating Temperature SiC-matrix Solar Thermal Air Receiver (HOTSSTAR). We report the results of our study of the effective heat transfer characteristic of several candidate structure motifs, or feature geometries, made of SiC via additive manufacturing in a simulative laboratory test. The SiC structure motifs studied include different permutations of three-dimensional periodic lattices and defined shapes. The solar-thermal simulating laboratory test setup is constructed using a 4kW CO2 laser system with beam shaping optics to apply radiative heating power on one face of 2”-diameter cylindrical feature specimens representing the structure motifs of interest for receiver element design. Using the test setup, simulative test conditions representative of a concentrated solar flux of up to ~2000 suns could be achieved in the lab tests under varying air flow through the test structure. A numerical analysis scheme is developed to extract an effective or compound heat transfer coefficient representative of the test structure under steady-state heat flow conditions.

14 SOLAR ENERGY↗

Determination of Arsenic Content in Water Using a Silver Coordination Polymer

In this report, we describe a practical method for the colorimetric determination of dissolved inorganic arsenic content in water samples, using a silver coordination polymer as the sensing material. We demonstrate that a crystalline polymer framework can be used to stabilize silver(I) ions, greatly reducing both photosensitivity and water solubility, while still affording sufficient reactivity to detect arsenic in water samples at low parts-per-billion (ppb) levels. Test strips fabricated with the silver-based polymer are shown to be effective for field tests of groundwater under real-world operating conditions and display performance that is competitive with commercially available mercury-based test strips. Spectroscopic methods are also used to probe the reaction products formed, in order to better understand the sensing mechanism. Thus, our work provides the foundation for an improved field test that could be deployed to help manage groundwater usage in regions where arsenic contamination is problematic but sophisticated lab testing is not readily available.

36 MATERIALS SCIENCE↗

Adhesive Wear of Rollers in Vacuum

This work was done to support NASA's James Webb Space Telescope that is equipped with a Near Infrared Camera and Spectrograph and Micro Shutter Assembly (MSA). A MSA mechanism's qualification test in cryogenic vacuum at 30deg K for 96K cycles resulted in roller wear and formation of some debris. Lab tests in vacuum were conducted at NASA Glenn Research Center (GRC) to understand the wear of Ti6Al4V mated with 440F steel rollers. Misalignment angle was found to have the most significant effect on debris formation. At misalignment angle of 1.4deg, significant amount of wear debris were formed within 50,000 cycles. Very few wear particles were found for a zero misalignment angle, and the total wear was small even after 367,000 cycles. The mode of wear in all the tests was attributed to adhesion, which was clearly evident from video records as well as the plate-like amalgamated debris material from both rollers. The adhesive wear rate was found to be approximately proportional to the misalignment angle. The wear is a two-way phenomenon, and the mixing of both roller materials in wear debris was confirmed by x-ray fluorescence (XRF) and EDX spectra. While there was a net loss of mass from the steel rollers, XRF and energy dispersive x-ray (EDX) spectra showed peaks of Ti on steel rollers, and peaks of Fe on Ti rollers. These results are useful for designers in terms of maintaining appropriate tolerances to avoid misalignment of rolling elements and the resulting severe wear

Shaeef, Iqbal↗

Progress in Simulated Water Well Performance on Mars

Recent studies of human Mars missions considered the impacts of an abundant supply of in-situ, accessible water on these mission scenarios. Discovery of exposed water ice scarps in Martian mid-latitudes has bolstered the evidence for massive amounts of almost pure water in buried deposits in regions considered candidates for these future human missions. This paper describes progress towards adapting a long-standing terrestrial technique for accessing and extracting water from these mid-latitude sources of ice. This approach relies on mechanical drills to access the ice through overlying debris. Once the ice layer has been reached, a technique known as a Rodriguez Well, or Rodwell, is used to melt the ice, store the resulting water in a subsurface cavity until needed, and then pump the water to the surface for use. Previous work by the authors utilized a computer simulation to predict the performance of a Martian Rodwell. This simulation was originally developed to predict performance in terrestrial Polar Regions. Whereas the basic approach is appropriate for a similar well on Mars, several parameters had been empirically derived and required experiments simulating the Martian environment to determine the values appropriate for a Martian Rodwell simulation. These experiments have now been completed and preliminary values have been determined for the empirical parameters. Test results are consistent with a dimensionless Sh(Ra) correlation developed by Bower and Saylor (2009) and based on lab tests of water evaporating from a pool into a large air chamber. They are also consistent with correlations derived by Ingersoll (1970) and by Hecht (2002), based on natural-convection heat transfer. Each of these earlier correlations found Sh~Ra1/3, with the 1/3rd power characteristic of large Ra where the boundary layer over the pool surface is turbulent. A somewhat surprising result was that this power-law was found to extend into a range of Ra where laminar flow would be expected. Another surprising result was found in that instead of following established correlations for natural-convection heat transfer over flat plates, the dimensionless heat-transfer rates (Nu) were much larger and approximately independent of Ra. This suggests that mass transfer from the pool enhances convective heat transfer, possibly by enhanced mixing in the boundary layer. Although this possibility has been suggested in the literature, if it is proven to be true under these conditions it could play an important role in the use of a Rodwell on Mars, where evaporative mass transfer is enhanced relative to terrestrial wells.

Human Mars Mission↗

Force limited vibration testing

A new method of conducting lab vibration tests of spacecraft equipment was developed to more closely simulate the vibration environment experienced when the spacecraft is launched on a rocket. The improved tests are tailored to identify equipment design and workmanship problems without inducing artificial failures that would not have occurred at launch. These new, less destructive types of vibration tests are essential to JPL's protoflight test approach in which lab testing is conducted using the flight equipment, often one of a kind, to save time and money. In conventional vibration tests, only the input vibratory motion is specified; the feedback, or reaction force, between the test item and the vibration machine is ignored. Most test failures occur when the test item goes into resonance, and the reaction force becomes very large. It has long been recognized that the large reaction force is a test artifact which does not occur with the lightweight, flexible mounting structures characteristic of spacecraft and space vehicles. In new vibration tests, both the motion and the force provided to the test item by the vibration machine are controlled, so that the vibration ride experienced by the test item is as in flight.

Scharton, Terry D.↗