Search NASASearch

SEARCH · Search NASA

Results for “Laser interferometry”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

63 records · Page 4

Collinear Three-Photon Excitation of a Strongly Forbidden Optical Clock Transition

The 1 𝑆 0 − 3 𝑃 0 clock transition in strontium serves as the foundation for the world’s best atomic clocks and for gravitational wave detector concepts in clock atom interferometry. This transition is weakly allowed in the fermionic isotope 87 Sr but strongly forbidden in bosonic isotopes. Here, we demonstrate coherent excitation of the clock transition in bosonic 88 Sr using a novel collinear three-photon process in a weak magnetic field. We observe Rabi oscillations with frequencies of up to 50 kHz using W/cm 2 laser intensities and Gauss-level magnetic field amplitudes. The absence of nuclear spin in bosonic isotopes offers decreased sensitivity to magnetic fields and optical lattice light shifts, enabling atomic clocks with reduced systematic errors. The collinear propagation of the laser fields permits the interrogation of spatially separated atomic ensembles with common laser pulses, a key requirement for dark matter searches and gravitational wave detection with next-generation quantum sensors.

74 ATOMIC AND MOLECULAR PHYSICS

EXPLORING INTERFEROMETRY DIAGNOSTICS FOR OPTICAL STOCHASTIC COOLING AT FAST/IOTA

Optical Stochastic Cooling (OSC) is an advanced beam-cooling technique that will advance the traditional stochastic cooling. This method leverages optical radiation and high-precision feedback to cool the particles more efficiently than traditional stochastic methods by more than three orders of magnitude. As such, it is an enabler for the development of next generation discovery science machines at the frontiers of energy and intensity. This paper focuses on the development of the second phase of OSC and improving extreme beam cooling techniques in accelerators. The goal was to build and characterize a Mach-Zehnder Interferometer (MZI) in the FAST laser lab using known glass plates thickness which will allow future measurements of unknown phase change due to nonlinear amplification processes.

Teriba, Folashade

Redefining precision interferometry and spectroscopy with high-performance optical interference coatings

High-performance optical interference coatings have transformed precision interferometry and spectroscopy by enabling unparalleled control over light–matter interactions. This review explores recent innovations in ion-beam sputtered amorphous dielectric, as well as substrate-transferred crystalline coatings, and their impact on systems at the forefront of precision metrology. These state-of-the-art coating techniques generate multilayers with ultralow optical losses, yielding mirrors with exceptional reflectivity. Refinements in their noise performance push the ultimate limits of sensitivity, resolution, and stability in demanding laser-based metrology applications. These technologies underpin the most advanced timekeeping and spatial measurement tools, enabling high-finesse reference cavities for the world’s most precise optical atomic clocks and low-noise reflective test masses for km-baseline gravitational-wave detectors. Emerging hybrid designs combining these techniques expand access to the mid-infrared spectral region, enabling the first ultralow-optical-loss coatings in the 3000–5000 nm wavelength range for enhanced spectroscopy and trace-gas detection. We highlight how these technologies redefine coating performance metrics and set new benchmarks in quantum science, fundamental physics, and precision optical sensing.

Cole, Garrett D. [University of Arizona, Tucson, A

Exploring Interferometry Diagnostics for Optical Stochastic Cooling at FAST/IOTA

Optical Stochastic Cooling (OSC) is an advanced beam-cooling technique that will precede the traditional stochastic cooling. This method leverages optical radiation and high-precision feedback to cool the particles more efficiently than traditional stochastic methods by more than three orders of magnitude. As such, it is an enabler for the development of next generation discovery science machines at the frontiers of energy and intensity. This paper focuses on the development of the second phase of OSC and improving extreme beam cooling technique in accelerators. Along with the assembly and use of an interferometer to provide diagnostics and optimization to OSC systems. The interferometer can allow for the observation and analysis of fringe patterns from a recreated simpler version in the laser room. By leveraging interferometric techniques, OSC can achieve higher efficiency, verification, stability and performance.

Teriba, Folashade

Flashlamp drive system for a high-energy 10–100 kHz pulse-burst Nd:YAG laser

We present the design of the flashlamp drive system for the NG100 laser, a 1 J/pulse, 10–100 kHz, pulse-burst Nd:YAG laser system being developed for application in a Thomson scattering plasma diagnostic. This flashlamp drive system is under active development, with a prototype now being constructed. The flashlamp drive system is modular, with each module capable of driving a series pair of linear flashlamps. Each drive module contains and is controlled by a dedicated Analog Regulator Controller. Thus each module is independently operable and controllable. This modular approach imposes no intrinsic limit to the number of modules that may be applied to drive the flashlamp pairs in a laser system. Each flashlamp drive module has a switch-regulated topology. An 1800 V main capacitor bank provides 25 kJ of energy storage, while a lower voltage output capacitor bank provides filtering and the initial energy delivered to the flashlamps at the start of the drive pulse. The main bank is recharged after each flashlamp drive pulse. As energy is drawn from the output bank by the flashlamps, an IGBT switching regulator feeds current from the main bank through an inductor to replenish the output capacitor bank. The rate of replenishment is feedback-controlled to maintain a regulated supply of power to the flashlamp load, with a setpoint range of 0.07 to 1.65 MW. An Analog Regulator Controller produces two-state variable pulse width feedback switching of the regulator IGBT. The switching frequency is ≤ 20 kHz, dynamically adjusted to limit ripple of the flashlamp power to ±3% statistical standard deviation of mean. For development or troubleshooting, each module is operable independent of the laser digital control system (microcontroller and FPGA).

Plasma diagnostics - interferometry

Horn Location Sensors for LBNF

The Horn Location Sensor (HLS) system—named for the magnetic focusing horns it monitors, along with other critical beamline elements – is a high-precision alignment system developed for the Long-Baseline Neutrino Facility (LBNF) to support the Deep Underground Neutrino Experiment (DUNE). With minimal maintenance, the HLS can operate reliably in environments with high radiation, and it ensures that key components such as the protective baffle, focusing horns, and beam position monitors are aligned correctly – each essential for maintaining one of the world’s most intense muon-neutrino beams. A high-precision hydrostatic level sensor, a linear variable differential transformer, and INVAR rods are all used in the system to monitor vertical motion and tilt with sub-millimeter accuracy. A novel Sweep Tracker interferometer enhances calibration fidelity by correcting for non-linearities in laser wavelength and scan rate in real time. A critical part of DUNE’s precision alignment and flux prediction requirements, the HLS system initially supports beam power of up to 1.2 MW and can be upgraded to 2.4 MW.

Frequency scanning interferometry

Detecting gravitational signatures of dark matter with atom gradiometers

We study the purely gravitational signatures of dark matter from the ultralight to the ultraheavy mass range in proposed long-baseline atom gradiometers, focusing on terrestrial designs, such as AION-km and MAGIS-km, as well as space-based concepts, such as MAGIS-space, AEDGE and AEDGE+. Due to its exceptional acceleration sensitivity and depending on astrophysical backgrounds, a detector similar to AEDGE+ could detect a dark matter subcomponent which constitutes 𝒪⁡(10%) of the local dark matter energy density and is populated by compact clumps of mass between 10 6 kg and 10 10 kg (10 −25 ⁢𝑀⊙ ≲ 𝑀 ≲10 −21⁢ 𝑀⊙) in an otherwise unexplored region of dark matter model space. Furthermore, because the gravitational observable depends on the relative gravitational time delay measured by spatially separated atomic clouds, we find that atom gradiometers are parametrically more sensitive than laser interferometers, such as LIGO and LISA, to fast-oscillating spacetime perturbations sourced by energy density and pressure fluctuations of ultralight dark matter. Depending on astrophysical backgrounds, a detector akin to AEDGE+ could probe a DM overdensity of 𝒪⁡(10) times the local dark matter energy density for masses 𝑚 ≲10 −17 eV.

79 ASTRONOMY AND ASTROPHYSICS

High-precision phase control of an optical lattice with up to 50 dB noise suppression

An optical lattice is a periodic light crystal constructed from the standing-wave interference patterns of laser beams. It can be used to store and manipulate quantum degenerate atoms and is an ideal platform for the quantum simulation of many-body physics. A principal feature is that optical lattices are flexible and possess a variety of multidimensional geometries with modifiable band structure. An even richer landscape emerges when control functions can be applied to the lattice by modulation of the position or amplitude with Floquet driving. However, the desire of realizing high-modulation bandwidths while preserving extreme lattice stability has been difficult to achieve. In this paper, we demonstrate an effective solution that consists of overlapping two counterpropagating lattice beams and controlling the phase and intensity of each with independent acousto-optic modulators. Our phase controller mixes sampled light from both lattice beams with a common optical reference. This dual heterodyne locking method allows exquisite determination of the lattice position, while also removing parasitic phase noise accrued as the beams travel along separate paths. Here, we report up to 50 dB suppression in lattice phase noise in the 0.1–1 Hz band, along with significant suppression spanning more than 4 decades of frequency. The absolute phase diffusion of the lattice position is only 10 Å when integrated over 10 s. This method permits precise, high-bandwidth modulation (greater than 50 kHz) of the optical lattice intensity and phase. We demonstrate the efficacy of this approach by executing intricate time-varying phase profiles for atom interferometry.

Atom interferometry

Titanium alloy response sensitivity to variations in spectral reconstructions of National Ignition Facility xenon line-emission x-ray sources

Thermomechanical shock experiments on the National Ignition Facility (NIF) aim to study high strain rate dynamic material response. In such experiments, the NIF laser is used to generate high fluence x-ray emission sources, which irradiate material samples of interest. Under sufficiently high x-ray energy deposition, thermomechanical impulses are generated in the materials. While it is known that the characteristics of x-ray generated impulses vary as a function of incident x-ray spectra, it remains unclear how spectral assumptions and uncertainties in NIF spectral reconstructions affect our interpretation of impulsive loading. Here, in this paper, we simulate the response of a standard titanium alloy baseline sample to synthetic analytically derived and measured NIF xenon line-emission x-ray sources with a radiation hydrodynamics code. We vary the source spectral characteristics based on different source reconstruction techniques to understand the resulting variation in baseline sample response and compare the simulated response with experimental results. We find that the response is highly sensitive to assumptions made about the spectral contents and that knowledge of spectral uncertainties bounds our understanding of the resulting material response. The results of this effort help to extend our ability to use baseline material samples to extract quantitative properties from x-ray experiments on the NIF.

Alloys